Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plasma detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Micron-sized particle impacts detected near Uranus by the Voyager 2 plasma wave instrument

The characteristics and distribution of the small particles detected by the plasma-wave and radio-astronomy instruments during the Voyager 2 encounter with Uranus in January 1986 are examined. The nature of the observational data and the analysis techniques employed are discussed, and the results are presented in graphs. Particles of rms mass about 2.6 ng and radii of a few microns were found in an impact region of thickness 3840 km, with a maximum number density of 1600/cu m about 280 km from the equatorial plane, shortly after Voyager 2 crossed the plane of the Uranian rings. The possible origin of the particles in the rings or in small satellites outside the rings is considered.

Gurnett, D. A.↗

Electric Currents Induced in Plasma by Ion-Acoustic Solitons: Allowance for Trapped Electrons

The currents induced by ion-acoustic solitons have been studied in a two-component magnetic–hydrodynamic approximation (MHD model) taking into account the trapped electrons. The solitons have been shown to excite unipolar nonpolar pulses of the ion and electron currents, and the established mechanisms of their excitation are. The spatiotemporal characteristics of the current pulses have been calculated, and the requirements for the spatiotemporal resolution of the experimental equipment necessary for detection of plasma currents induced by solitons have been determined. It has been shown that the solitons are the effective mechanism of plasma current generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasi-isentropic compressibility of a strongly nonideal deuterium plasma at pressures of up to 5500 GPa: Nonideality and degeneracy effects

We report on the experimental results on the quasi-isentropic compressibility of a strongly nonideal deuterium plasma that have been obtained on setups of cylindrical and spherical geometries in the pressure range of up to P ≈ 5500 GPa. We describe the characteristics of experimental setups, as well as the methods for the diagnostics and interpretation of the experimental results. The trajectory of metal shells that compress the deuterium plasma was detected using powerful pulsed X-ray sources with a maximal electron energy of up to 60 MeV. The values of the plasma density, which varied from ρ ≈ 0.8 g/cm{sup 3} to ρ ≈ 6 g/cm{sup 3}, which corresponds to pressure P ≈ 5500 GPa (55 Mbar), were determined from the measured value of the shell radius at the instant that it was stopped. The pressure of the compressed plasma was determined using gasdynamic calculations taking into account the actual characteristics of the experimental setups. We have obtained a strongly compressed deuterium plasma in which electron degeneracy effects under the conditions of strong interparticle interaction are significant. The experimental results have been compared with the theoretical models of a strongly nonideal partly degenerate plasma. We have obtained experimental confirmation of the plasma phase transition in the pressure range near 150 GPa (1.5 Mbar), which is in keeping with the conclusion concerning anomaly in the compressibility of the deuterium plasma drawn in [1].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillating plasma bubble and its associated nonlinear studies in presence of low magnetic field

Oscillating plasma bubbles have been created around a cylindrical mesh grid of 75% optical transparency in a DC plasma system with a low magnetic field. Plasma bubbles are created by developing ion density gradient around a cylindrical grid of 20 cm in diameter and 25 cm in height, inserted into the plasma. Relaxation and contraction of the plasma bubbles in the presence of external conditions, such as magnetic field and pressure, have been studied. A Langmuir probe has been used to detect the plasma floating potential fluctuations at different imposed experimental conditions. Nonlinear behavior of the system has been characterized by adopting nonlinear techniques such as Fast Fourier Transform, Phase Space Plot, and Recurrence Plot. It shows that the system creates highly nonlinear phenomena associated with the plasma bubble under the imposed experimental conditions. A theoretical and numerical model has also been developed to satisfy the observed experimental analysis. Moreover, observations are extended further to study the growth of instability associated with the plasma bubbles. The intention of the present work is to correlate the findings about plasma bubbles and their related instability with the one existing in the equatorial F-region of the ionosphere.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Complementary ion and extreme ultra-violet spectrometer for laser-plasma diagnosis

Simultaneous detection of extreme ultra-violet (XUV) and ion emission along the same line of sight provides comprehensive insight into the evolution of plasmas. This type of combined spectroscopy is applied to diagnose laser interaction with a spray target. The use of a micro-channel-plate detector assures reliable detection of both XUV and ion signals in a single laser shot. The qualitative analysis of the ion emission and XUV spectra allows to gain detailed information about the plasma conditions, and a correlation between the energetic proton emission and the XUV plasma emission can be suggested. The measured XUV emission spectrum from water spray shows efficient deceleration of laser accelerated electrons with energies up to keV in the initially cold background plasma and the collisional heating of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of chlorine-oxygen plasmas and evidence for heterogeneous formation of ClO and ClO{sub 2}

Plasma and surface diagnostics of Cl{sub 2}/O{sub 2} mixed-gas inductively coupled plasmas are reported. Using trace rare gas optical emission spectroscopy and Langmuir probe analysis, electron temperatures (T{sub e}) and number densities for Cl atoms (n{sub Cl}), electrons (n{sub e}), and positive ions were measured as a function of percent O{sub 2} in the feed gas and position in the plasma chamber. Adsorbates on and products desorbing from a rotating anodized aluminum substrate exposed to the plasma were detected with an Auger electron spectrometer and a quadrupole mass spectrometer. T{sub e} and n{sub e} increased with increasing percent O{sub 2} in the plasma, while n{sub Cl} fell off with O{sub 2} addition in a manner reflecting simple dilution. Cl atom recombination probabilities (gamma{sub Cl}) were measured and were found to be a nearly constant 0.036+-0.007 over the range of Cl{sub 2}/O{sub 2} mixing ratios and Cl coverage. Large yields of ClO and ClO{sub 2} were found to desorb from the surface during exposure to the plasma, ascribed predominantly to Langmuir-Hinshelwood reactions between adsorbed O and Cl.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of a new parametric decay instability branch in TST-2 during high harmonic fast wave heating

Parametric decay instability (PDI) is often observed in the TST-2 spherical tokamak during high harmonic fast wave heating by rf pickup probes. The frequency spectrum exhibits lower and upper sideband peaks in addition to the pump wave at f{sub 0}=21 MHz. Two types of PDI are observed. One is the well-known decay into the ion-cyclotron quasimode (nf{sub ci}) and the ion Bernstein wave (f{sub 0}-nf{sub ci}). The other is a newly found decay with the sideband frequency between f{sub 0} and f{sub 0}-f{sub ci}. The frequency difference between this sideband and the pump increases in proportion to B{sub t}. Moreover, high-speed visible light measuring systems with photomultiplier tubes or hybrid photodetectors viewing the plasma core detected oscillation of light emission at around f{sub 0}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Substorm-associated reconfiguration of the dusk side equatorial magnetosphere - A possible source mechanism for isolated plasma regions

A rapid reconfiguration of the dusk side magnetosphere was observed near the magnetic equator by particle and field experiments aboard Explorer 45 at 1715 UT on June 17, 1972. Following the onset of an 800-gamma negative bay in the auroral zone, Explorer 45, inbound at 1700 MLT and L about 5, observed a sharp dropout of outer zone electrons. Simultaneously, the plasma density dropped from a level typical of the plasmasphere to one typical of the ion trough, and plasma sheet proton fluxes increased, producing a 100-gamma depression in B, in a shift to a taillike configuration. Outer zone electrons with pitch angles near 45 deg returned with delay times consistent with injection near midnight at the time of dropout and eastward drift to the dusk meridian. Approximately 45 min after the reconfiguration, the satellite reentered the plasmasphere, and the electron fluxes returned to previous levels. In the next orbit, approximately 6 hours later, a region of isolated plasma was detected near apogee at 1400 MLT. There is therefore circumstantial evidence that the type of magnetospheric reconfiguration observed here is responsible for the detachment of regions of cold plasma from the plasmasphere.

Barfield, J. N.↗

Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refined at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

A Study of Uranus' Bow Shock Motions Using Langmuir Waves

During the Voyager 2 flyby of Uranus, strong electron plasma oscillations (Langmuir waves) were detected by the plasma wave instrument in the 1.78-kHz channel on January 23-24, 1986, prior to the inbound bow shock crossing. Langmuir waves are excited by energetic electrons streaming away from the bow shock. The goal of this work is to estimate the location and motion of Uranus' bow shock using Langmuir wave data, together with the spacecraft positions and the measured interplanetary magnetic field. The following three remote sensing analyses were performed: the basic remote sensing method, the lag time method, and the trace-back method. Because the interplanetary magnetic field was highly variable, the first analysis encountered difficulties in obtaining a realistic estimation of Uranus' bow shock motion. In the lag time method developed here, time lags due to the solar wind's finite convection speed are taken into account when calculating the shock's standoff distance. In the new trace-back method, limits on the standoff distance are obtained as a function of time by reconstructing electron paths. Most of the results produced by the latter two analyses are consistent with predictions based on the standard theoretical model and the measured solar wind plasma parameters. Differences between our calculations and the theoretical model are discussed.

Xue, S.↗

A revised analysis of micron-sized particles detected near Saturn by the Voyager 2 plasma wave instrument

The impulsive noise that the plasma wave and radio astronomy instruments detected during the Voyager 2 swing by Saturn was attributed to dust grains striking the spacecraft. This report presents a reanalysis of the dust impacts recorded by the plasma wave instrument using an improved model for the response of the electric antenna to dust impacts. The fundamental assumption used in this analysis is that the voltage induced on the antenna is proportional to the mass of the impacting grain. Using the above assumption and the antenna response constants used at Uranus and Neptune, the following conclusions can be reached. The primary dust distribution consists of a 'disk' of particles that coincides with the equator plane and has a north-south thickness of 2-Delta zeta = 962 km. A less dense 'halo' with a north-south thickness of 2-Delta zeta = 3376 km surrounds the primary distribution. The dust particle sizes are of the order of 10 microns, assuming a mass density of 1 g/cu cm. The corresponding particle masses are of the order of 10(exp -9) g, and maximum number densities are of the order of 10(exp -2)/cu m. Most likely, the G ring is the dominate source since the particles were observed very close to that ring, namely at 2.86 R(sub S). Other sources, like nearby moons, are not ruled out especially when perturbations due to electromagnetic forces are included. The calculated optical depth differs by about a factor of 2 from photometric studies. The current particle masses, radii, and the effective north-south thickness of the particle distribution are larger than what Gurnett et al. (1983) reported by about 2, 1, and 1 orders of magnitude, respectively. This is attributed to the fact that the collection coefficient used in this study is smaller than what was used in Gurnett et al.'s earlier publication.

Tsintikidis, D.↗

{gamma}-ray measurements and neutron sensitivity in a fusion environment

A system based on a LaBr{sub 3}(Ce) scintillator and digital data acquisition is discussed in view of {gamma}-ray spectroscopy measurements on a fusion burning plasma. High energy resolution and high rate capability of the system are demonstrated in laboratory tests and in dedicated experiments at nuclear accelerators. Preliminary results on sensitivity of the detector to 14 MeV neutrons are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disposition of the Dietary Mutagen 2-Amino-3,8-dimethylimidazo[4,5- f ]quinoxaline in Healthy and Pancreatic Cancer Compromised Humans

Pancreatic cancer is the fourth leading cause of cancer death in the U.S. Once diagnosed, prognosis is poor with a 5-year survival rate of less than 5%. Exposure to carcinogenic heterocyclic amines (HCAs) derived from cooked meat has been shown to be positively associated with pancreatic cancer risk. To evaluate the processes that determines the carcinogenic potential of HCAs for human pancreas, 14-carbon labeled 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), a putative human carcinogenic HCA found in well-done cooked meat, was administered at a dietary relevant dose to human volunteers diagnosed with pancreatic cancer undergoing partial pancreatectomy and healthy control volunteers. After 14C-MeIQx exposure, blood and urine was collected for pharmacokinetic and metabolite analysis. MeIQx-DNA adducts levels were quantified by accelerator mass spectrometry from pancreatic tissue excised during surgery from the cancer patient group. Pharmacokinetic analysis of plasma revealed a rapid distribution of MeIQx with a plasma elimination half-life of approximately 3.5 hr in 50% of the cancer patients and all of the control volunteers. In 2 of the 4 cancer patients very low levels of MeIQx were detected in plasma and urine suggesting low absorption from the gut into the plasma. Urinary metabolite analysis revealed five MeIQx metabolites with 2-amino-3-methylimidazo[4,5-f]quinoxaline-8-carboxylic acid being the most abundant accounting for 25%–50% of the recovered 14-carbon/ml urine. We found there was no discernable difference in metabolite levels between the cancer patient volunteers and the control group. MeIQx-DNA adduct analysis of pancreas and duodenum tissue revealed adduct levels indistinguishable from background levels. Lastly, although other meat-derived HCA mutagens have been shown to bind DNA in pancreatic tissue, indicating that exposure to HCAs from cooked meat cannot be discounted as a risk factor for pancreatic cancer, the results from this current study show that exposure to a single dietary dose of MeIQx does not readily form measurable DNA adducts under the conditions of the experiment.

59 BASIC BIOLOGICAL SCIENCES↗

The Thermal Ion Dynamics Experiment and Plasma Source Instrument

The Thermal Ion Dynamics Experiment (TIDE) and the Plasma Source Instrument (PSI) have been developed in response to the requirements of the ISTP Program for three-dimensional (3D) plasma composition measurements capable of tracking the circulation of low-energy (0-500 eV) plasma through the polar magnetosphere. This plasma is composed of penetrating magnetosheath and escaping ionospheric components. It is in part lost to the downstream solar wind and in part recirculated within the magnetosphere, participating in the formation of the diamagnetic hot plasma sheet and ring current plasma populations. Significant obstacles which have previously made this task impossible include the low density and energy of the outflowing ionospheric plasma plume and the positive spacecraft floating potentials which exclude the lowest-energy plasma from detection on ordinary spacecraft. Based on a unique combination of focusing electrostatic ion optics and time of flight detection and mass analysis, TIDE provides the sensitivity (seven apertures of about 1 cm squared effective area each) and angular resolution (6 x 18 degrees) required for this purpose. PSI produces a low energy plasma locally at the POLAR spacecraft that provides the ion current required to balance the photoelectron current, along with a low temperature electron population, regulating the spacecraft potential slightly positive relative to the space plasma. TIDE/PSI will: (a) measure the density and flow fields of the solar and terrestrial plasmas within the high polar cap and magnetospheric lobes; (b) quantify the extent to which ionospheric and solar ions are recirculated within the distant magnetotail neutral sheet or lost to the distant tail and solar wind; (c) investigate the mass-dependent degree energization of these plasmas by measuring their thermodynamic properties; (d) investigate the relative roles of ionosphere and solar wind as sources of plasma to the plasma sheet and ring current.

Moore, T. E.↗

Quantitation of Human Papillomavirus DNA in Plasma of Oropharyngeal Carcinoma Patients

Purpose: To determine whether human papillomavirus (HPV) DNA can be detected in the plasma of patients with HPV-positive oropharyngeal carcinoma (OPC) and to monitor its temporal change during radiotherapy. Methods and Materials: We used polymerase chain reaction to detect HPV DNA in the culture media of HPV-positive SCC90 and VU147T cells and the plasma of SCC90 and HeLa tumor-bearing mice, non-tumor-bearing controls, and those with HPV-negative tumors. We used real-time quantitative polymerase chain reaction to quantify the plasma HPV DNA in 40 HPV-positive OPC, 24 HPV-negative head-and-neck cancer patients and 10 non-cancer volunteers. The tumor HPV status was confirmed by p16{sup INK4a} staining and HPV16/18 polymerase chain reaction or HPV in situ hybridization. A total of 14 patients had serial plasma samples for HPV DNA quantification during radiotherapy. Results: HPV DNA was detectable in the plasma samples of SCC90- and HeLa-bearing mice but not in the controls. It was detected in 65% of the pretreatment plasma samples from HPV-positive OPC patients using E6/7 quantitative polymerase chain reaction. None of the HPV-negative head-and-neck cancer patients or non-cancer controls had detectable HPV DNA. The pretreatment plasma HPV DNA copy number correlated significantly with the nodal metabolic tumor volume (assessed using {sup 18}F-deoxyglucose positron emission tomography). The serial measurements in 14 patients showed a rapid decline in HPV DNA that had become undetectable at radiotherapy completion. In 3 patients, the HPV DNA level had increased to a discernable level at metastasis. Conclusions: Xenograft studies indicated that plasma HPV DNA is released from HPV-positive tumors. Circulating HPV DNA was detectable in most HPV-positive OPC patients. Thus, plasma HPV DNA might be a valuable tool for identifying relapse.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mass ejections from the sun and their interplanetary counterparts

Since the first observations of solar mass ejection events in the early seventies from OSO 7 and Skylab a few thousand of these remarkable dynamic incidents have been observed by now, covering about two full solar activity cycles. The mass ejecta include mainly hot coronal plasma, plus cold prominence material in variable amounts. The ejecta are often recognised in the form of interplanetary plasma clouds detected in the distant solar wind by appropriately located spacecraft. Clouds which have been energetic enough to drive large scale interplanetary shock waves can be identified most readily, but clouds without associated shocks do also occur. The plasma clouds are characterized by a variety of signatures indicating that they actually originate from injections of different material into the ambient solar wind. Usually only a few of the signatures are found simultaneously. Apparently the bidirectional streaming of halo electrons is a most reliable criterion, indicating a magnetic bottle or plasmoid topology of the clouds. The discussion of the most recent discoveries in this context will show that quite a few crucial problems still remain to be addressed by the upcoming SOHO mission.

Schwenn, R.↗

Fast camera studies at an electron cyclotron resonance table plasma generator

A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the “big” ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗