Single crystal and polycrystalline GaAs solar cells using AMOS technology

A description is given of current technology for fabricating single AMOS (antireflection-coated metal oxide semiconductor) solar cells, with attention given to thermal, plasma, and anodic oxidation, native oxide stripping, and X-ray photoelectron spectroscopy results. Some preliminary results are presented on the chemistry and electrical characterization of such cells, and the characteristics of cells fabricated on sliced polycrystalline GaAs wafers are examined. Consideration is also given to the recrystallization of evaporated Ge films for use as low-cost substrates for polycrystalline GaAs solar cells.

Stirn, R. J.↗

Impulsive phase of flares in soft X-ray emission

Observations using the bent crystal spectrometer instrument on the Solar Maximum Mission show that turbulence and blue-shifted motions are characteristic of the soft X-ray plasma during the impulsive phase of flares, and are coincident with the hard X-ray bursts observed by the hard X-ray burst spectrometer. A method for analysing the Ca XIX and Fe XXV spectra characteristic of the impulsive phase is presented. Nonthermal widths and blue-shifted components in the spectral lines of Ca XIX and Fe XXV indicate the presence of turbulent velocities exceeding 100 km/s and upward motions of 300-400 km/s. The April 10, May 9, and June 29, 1980 flares are studied. The April 10 flare has two separated footpoints bright in hard X-rays. Plasma heated to temperatures greater than ten million K rises from the footpoints. During the three minutes in which the evaporation process occurs an energy of 3.7 x 10 to the 30th ergs. This is consistent with the above figures, allowing for loss by radiation and conduction.

Antonucci, E.↗

Selective and low temperature synthesis of polycrystalline diamond

Polycrystalline diamond thin films have been deposited on single-crystal silicon substrates at low temperatures (not above 600 C) using a mixture of hydrogen and methane gases by high-pressure microwave plasma-assisted chemical vapor deposition. Low-temperature deposition has been achieved by cooling the substrate holder with nitrogen gas. For deposition at reduced substrate temperature, it has been found that nucleation of diamond will not occur unless the methane/hydrogen ratio is increased significantly from its value at higher substrate temperature. Selective deposition of polycrystalline diamond thin films has been achieved at 600 C. Decrease in the diamond particle size and growth rate and an increase in surface smoothness have been observed with decreasing substrate temperature during the growth of thin films. As-deposited films are identified by Raman spectroscopy, and the morphology is analyzed by scanning electron microscopy.

Ramesham, R.↗

Thruster momentum transfer studies and magnetoplasmadynamic (MPD) thruster use in materials/surface modification

This research project involves the systematic study of the MPD thruster for dual uses. Though it was designed as a thruster for space vehicles, the characteristics of the plasma make it an excellent candidate for industrial applications. This project will seek to characterize the system for use in materials processing and characterization. Crystals grown at Fisk University for use with solid state detectors will be studied. Surface modification on ZnCdTe, CdTe, and ZnTe will be studied using AFM, XPS and SAES. In addition to the surface modification studies, design work on a momentum transfer measurement device has been completed. The design and limitations of the device will be presented.

Thompson, E.↗

Implementation of Pfirsch–Schlüter parallel flow in x-ray imaging crystal spectrometer inversion analysis

The x-ray imaging crystal spectrometer (XICS) tomographic inversion code for Wendelstein 7-X (W7-X) has been modified to consider the effects of parallel flows and has been applied to analyze measurements taken during recent experimental campaigns. Previous analysis neglected the effects of parallel flows due to the primarily perpendicular geometry of the sightlines and the small magnitude predicted by neoclassical theory. To reconsider these effects, the incompressibility condition for plasma flows is used to calculate the parallel Pfirsch–Schlüter flow component for the equilibrium configuration. By incorporating this condition along with the geometry of the sightlines—i.e. the fractional contributions of perpendicular and parallel flows—, an updated expression for the measured flow is used for the profile inversion. Application of this modified inversion code to data from W7-X shows that the magnitude of the radial electric field and the flux surface averaged perpendicular flow are reduced by approximately a factor of 2 and brought into better agreement with neoclassical predictions and charge exchange recombination spectroscopy measurements.

Pfirsch–Schlüter flows↗

Fabrication of nanometer single crystal metallic CoSi2 structures on Si

Amorphous Co:Si (1:2 ratio) films are electron gun-evaporated on clean Si(111), such as in a molecular beam epitaxy system. These layers are then crystallized selectively with a focused electron beam to form very small crystalline Co/Si2 regions in an amorphous matrix. Finally, the amorphous regions are etched away selectively using plasma or chemical techniques.

Nieh, Kai-Wei↗

Micro-segregation phenomena and related spectroscopic signals in melt-grown β-Ga2O3 single crystals

One of the primary advantages of β-Ga2O3 over incumbent wide bandgap semiconductors is the ability to grow directly from the melt. Melt growth, using Czochralski or similar methods, results in impurities in the crystal which originate from the crucible, such as iridium and other transition metals like chromium. These impurities exhibit optoelectronic signatures useful for their identification and sensitive to the Fermi energy of a given crystal (i.e., signatures vary with the electrical conductivity of the matrix). In this work, we describe how laser Raman systems can be used to map and spatially correlate Cr3+ photoluminescence, electronic-coupled Raman scattering from Ir4+d–d internal transitions, and the Raman line attributed to hydrogenic shallow donors. Laser ablation inductively coupled plasma mass spectrometry directly measured spatially dependent relative metal concentrations and confirmed spectroscopic signals resulting from heterogeneities in impurity concentrations in β-Ga2O3 boules. Mapping of photoluminescence and Raman-related signatures is, thus, demonstrated as an effective and facile method for spatial measurement of chemical heterogeneities in both insulating and conductive melt-grown β-Ga2O3 crystals.

Dutton, Benjamin L. (ORCID:000000031272130X)↗

Dry etching of beta-SiC in CF4 and CF4 + O2 mixtures

Dry etching of cubic (100) beta-SiC single-crystal thin films produced via chemical-vapor deposition (CVD) has been performed in CF4 and CF4 + O2 mixtures, in both the reactive-ion-etching (RIE) and plasma-etching modes. The latter process yielded measurable etch rates, but produced a dark surface layer which appears, from the results of secondary-ion mass spectrometry, to be residual SiC. The RIE samples had no residual layer, but Auger electron spectroscopy did reveal a C-rich surface. The optimal RIE conditions were obtained with 10 sccm of pure CF4 at 40 mtorr and a power density of 0.548 W/sq cm, giving an etch rate of 23.3 nm/min. Neither the increase of temperature between 293 and 573 K, nor the incremental addition of O2 to CF4 to 50 percent, produced any strong effect on the etch rates of SiC during RIE. Pictorial evidence of fine line structures produced by RIE of beta-SiC films are also presented.

Palmour, J. W.↗

High-resolution bandpass x-ray imaging with crystal reflectors: Overcoming geometric aberrations

The imaging problem of a specular reflector is revisited. Retaining terms through the second order in the reflector surface expansion, we derive the form of the aberration-limiting aperture for arbitrary magnification, assuming no bandwidth limitations. A permissible relative aperture size of the reflector is limited by a set relative aberration tolerance and scales with the tangent of the central glancing angle of incidence. These limiting aberrations become practically insignificant near backscattering. The results extend to x-ray diffracting crystals in symmetric Bragg geometry shaped as an ellipsoid of revolution. This geometry permits polychromatic imaging for hard x-rays over a bandwidth defined by the accepted range of Bragg angles, thereby suppressing aberrations of higher orders. We assess ellipsoidal crystal imagers using ray tracing simulations for two high-magnification designs with Bragg angles far from and close to backscattering. Finally, in both cases, the ellipsoidal crystals produce images of higher quality compared to those formed by equivalent toroidal crystal imagers.

Bragg reflection↗

MPEX AI Digital Twins

All magnetically confined plasma fusion power plant concepts (Tokamak, Spherical Tokamak, Stellarator, Mirror, ...) must exhaust the heat and plasma from the core confinement region to the material walls. The primary channel for this exhaust is through a plasma divertor which directs plasma along open magnetic field lines to a material target. The Material Plasma Exposure eXperiment (MPEX) illustrated in Figure 1, is a high-power, steady-state linear plasma device designed to produce the plasma material interaction (PMI) conditions of the divertor of future magnetic confinement fusion power plants: energy flux 20MW/m 2 , ion fluence 1031/m 2 , pulse duration 106 sec. These goals of plasma exposure in MPEX are well beyond those achieved in magnetic fusion experimental devices. Successfully achieving these high power steady state conditions for long pulses requires operational control of the heating and particle sources and the plasma flux to the walls and target. The MPEX AI Hot Spot Controller, proposed in this project, will help achieve the operational milestones of MPEX. The MPEX device will begin commissioning at the end of FY26. A smaller proto-MPEX was operated for 14,666 plasma discharges and will resume operation in September of 2025 as proto-MPEX-lite, with reduced capability, to test a new window for the Helicon plasma source. The proto-MPEX data has undergone surrogate modeling with machine learning methods (R. Archibald, 2022 IEEE International Conference on Big Data). This proto-MPEX data will be used to begin development of the AI digital twins described in this white paper. The scientific mission of MPEX is to qualify materials of different composition for use in the high energy and plasma flux conditions of a fusion power plant. The materials exposed in MPEX will in some cases be exposed to high neutron fluxes at other ORNL facilities to measure the changes to their PMI properties. The targets exposed in MPEX will be transported under vacuum to a Surface Analysis Station (SAS). The SAS will be equipped with the following diagnostics: Focused Ion Beam (FIB) for trench milling, 100-400 angstrom resolution scanning electron microscope (SEM), surface mapping x-ray spectrometer, high resolution camera, and a future upgrade to a laser induced breakdown spectroscopy quadruple mass spectrometer (LIBS-QMS). The MPEX experiments will generate diverse pre- and post-exposure measurement data of detailed material properties down to the crystal grain level in 3D for post-exposure assessment of PMI damage (e.g. cracking, melting, erosion and redeposition of the material). Physics models for the PMI, and how the material composition and manufacturing impact its performance under high energy plasma exposure, need to be validated with MPEX data to guide the selection of new candidate materials. Our vision for the MPEX AI Digital Twins project is to supply experimental and physics model simulation data to train Artificial Intelligence (AI) models for data processing, analysis, operational control, PMI and materials simulation to maximize the scientific output of the MPEX device. Ultimately, an AI digital twin of MPEX material assessment metrics for tested and synthetic material types with simulated PMI will be trained by the AI Modeling Teams on the experimental and physics simulation data submitted to the American Science Cloud by this project. A purely empirical search for the best material is inefficient given the finite number of samples that can be tested on MPEX. In order to expand the material properties database for training the MPEX Material Assessment AI Digital Twin, and to gain physics understanding of the PMI processes, physics models of the material properties and PMI processes are required. The physics simulations provide detailed simulation data, like impact angles for plasma ions, sputtering yields, transport of the ionized sputtered target material in the plasma, and redeposition locations. This simulation data expands the measurement data for deeper physics understanding. The experimental data is essential to validate the PMI and material structure simulation models. The validated models can then be used to generate new simulation data of MPEX material assessments for synthetic material compositions that have not been exposed in MPEX. These predictive simulations, plus the whole experimental dataset, will be used to train the MPEX Material Assessment AI Digital Twin allowing a rapid generative AI search for new materials with reduced PMI damage by interpolating the domain of the training set. These new optimum materials can be simulated with the physics codes and/or tested in MPEX. The ability of AI neural networks to interpolate multi-dimensional parameter spaces and generate virtual data is exploited for a more efficient search for optimum materials. The advent of the Transformational AI Models Consortium (TAIMC) is an opportunity to engage with state of the art private and public AI developers to achieve the goals of the AI digital twins and AI accelerated physics models proposed in this project. Our partners at ORNL from the Advance Scientific Computing Research (ASCR) organization will collaborate in accelerating the integrated plasma material interaction simulation framework. This simulation framework will provide a platform for generating simulation data across a range of physical fidelities, including hybrid methods that produce multi-fidelity results. This data will be leveraged for AI model development, both for generation of surrogates and the automation of simulation campaigns. A part of the research below will include collaborative efforts with the TAIMC to (i) adapt data storage approaches to ensure AI-readiness, (ii) provide a protypical exemplar to inform and exercise constructed workflows, and (iii) generate and share data, using the TAIMC unified AI data standard, for foundational models that will be trained from multiple sources across the DOE complex. We will also collaborate with the TAIMC, as well as the planned AI modeling teams, to develop approaches for reducing the cost of data generation. These include tailored multi-fidelity approaches as well as fine-tuning strategies to augment general, large-scale foundational models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

In-Situ Laser Diagnostics to Understand Plasma-Surface Interactions in Titanium Thin Film Deposition

During the current project period the following tasks were completed: (1) We demonstrated the feasibility of a new way of measuring CH3 radicals in a plasma environment using a single, femtosecond (fs) pulsed laser for the first time, in a CH4 + Ar flow. A single fs pulsed Ti:Sa laser was split into two beams and with beam conversion using crystals we generatedtwo beams of 275 nm and 205 nm. The 275 nm was used to predissociate the CH3 radicals to CH2+H, followed by 205 nm Two Photon Laser Induced Fluorescence (TALIF) detection of H atoms, with a 11 ns delay from 275 nm predissociation pulse. (2) We demonstrated preliminary CH3 concentration measurements with spatial (< 100 µm) and time resolution (< 10 ns) by image processing of H and Kr TALIF signal images. (3) The methodology to quantify CH3 concentrations was developed. (4) Preliminary measurements of laser dissociation cross sections for CH4 and CH3 to (CH3+H), and (CH2+H), respectively, were conducted. (5) 275 nm laser dissociation of CH4 is a multiphoton process, and the CH4 dissociation cross section is a more sensitive function of the laser pulse energy than CH4 concentration. In the coming months, we will make more precise measurements of the dissociation cross sections, 𝑘275, 𝐶𝐻4 and 𝑘275, 𝐶𝐻3, by varying the laser energy while keeping the flow composition and conditions constant. This will enable more precise quantification of CH3 radical concentrations. More detailed measurements of CH3 radicals will be conducted in the following months of 2025 (Sept-Dec) in a Titanium Isopropoxide (TIP) + H2 + Ar flow meant for pure phase Ti thin film deposition by Chemical Vapor Deposition (CVD). More precise measurements of 275 nm laser dissociation cross sections for CH4 (to CH3 + H) and CH3 (to CH2 + H) will be conducted in the future. Detailed 275 nm laser predissociation cross sections for CH4 and CH3 dissociation to (CH3+H), and (CH2+H), respectively, as a function of gas heating, plasma power, and laser pulse energy will be evaluated. This will enable quantification of CH3 concentrations in the precursor flow over a substrate with time and spatial resolution. Comparison of the concentrations with 2D numerical simulations can lead to understanding of plasma surface interactions during pure metallic Ti thin film deposition using environmentally safer non-halogen TIP precursor. Flow conditions for pure Ti thin film deposition using non-halogen precursor (TIP) will be identified in the following months.

Uddi, Mruthunjaya [Advanced Cooling Technologies, ↗

Soft X-ray flare spectra

Large solar flares produce intense soft X-ray emission, indicating the existence of high temperature plasmas that coexist in time with the plasmas responsible for the normally observed brightenings in H-alpha. The time behavior of the X-ray flux, as revealed, for example, by ion chamber detectors on the series of Solrad monitoring satellites, appears to roughly mimic the intensity-time behavior of the H-alpha flare, insofar as start times, times of maximum flux, and approximate decay times are concerned. In recent years, soft X-ray spectra of both active regions and solar flares have been obtained by instruments flown on spacecraft such as the Orbiting Solar Observatory (OSO) series. The disbursing elements used were Bragg crystals, and in the 8 Angstrom region the resolution is typically approximately 1200. This paper discusses the observed characteristics of X-ray flare spectra and spectroscopic diagnostics for determining electron temperatures, electron densities, and departures from ionization equilibrium within the soft X-ray emitting plasma.

Doschek, G. A.↗

Modeling Growth of Nanostructures in Plasmas

As semiconductor circuits shrink to CDs below 0.1 nm, it is becoming increasingly critical to replace and/or enhance existing technology with nanoscale structures, such as nanowires for interconnects. Nanowires grown in plasmas are strongly dependent on processing conditions, such as gas composition and substrate temperature. Growth occurs at specific sites, or step-edges, with the bulk growth rate of the nanowires determined from the equation of motion of the nucleating crystalline steps. Traditional front-tracking algorithms, such as string-based or level set methods, suffer either from numerical complications in higher spatial dimensions, or from difficulties in incorporating surface-intense physical and chemical phenomena. Phase field models have the robustness of the level set method, combined with the ability to implement surface-specific chemistry that is required to model crystal growth, although they do not necessarily directly solve for the advancing front location. We have adopted a phase field approach and will present results of the adatom density and step-growth location in time as a function of processing conditions, such as temperature and plasma gas composition.

Hwang, Helen H.↗

X-ray spectra of solar flares obtained with a high-resolution bent crystal spectrometer

Preliminary results obtained for three solar flares with the bent crystal spectrometer on the SMM are presented. Resonance and satellite lines of Ca XIX and XVIII and Fe XXV and XXIV are observed together with the Fe XXVI Lyman-alpha line. Plasma properties are deduced from line ratios and evidence is presented for changes of line widths coincident with the occurrence of a hard X-ray impulsive burst. Fe K-alpha spectra from a disk center and a limb flare agree with the predictions of a fluorescence excitation model. However, a transient Fe K-alpha burst observed in a third flare may be explained by the collisional ionization of cool iron by energetic electrons.

Culhane, J. L.↗

Measurement of coronal X-ray emission lines from Capella

The Einstein Observatory's Focal Plane Crystal Spectrometer has detected X-ray emission lines due to O VIII, Fe XVII, and Fe XX, from the binary star system Capella. Line luminosities are well fitted by an emitting plasma at a single temperature of 6.29 + or - 0.01 - 0.03 million K, and a volume emission measure of about 8.6 x 10 to the 52nd/cu cm, corresponding to the low temperature component previously observed. A high temperature component is undetectable, since the observed lines are not produced in plasma at temperatures above about 20 million K. Nearly isothermal plasma would be expected if many of the magnetically confined coronal loops have similar sizes and pressures, and a second population of longer loops would be required to account for the hotter component. An alternative interpretation of the observed X-ray line emission and upper limit is that the plasma contains a continuous distribution of emission measure versus temperature that rises sharply to 3 million K and then falls by nearly a decade to 16 million. An extrapolation of the loop sizes suggested by this alternative to hotter, longer loops may also account for the higher temperature emission.

Vedder, P. W.↗

Dislocation Content Measured Via 3D HR-EBSD Near a Grain Boundary in an AlCu Oligocrystal

Interactions between dislocations and grain boundaries are poorly understood and crucial to mesoscale plasticity modeling. Much of our understanding of dislocation-grain boundary interaction comes from atomistic simulations and TEM studies, both of which are extremely limited in scale. High angular resolution EBSD-based continuum dislocation microscopy provides a way of measuring dislocation activity at length scales and accuracies relevant to crystal plasticity, but it is limited as a two-dimensional technique, meaning the character of the grain boundary and the complete dislocation activity is difficult to recover. However, the commercialization of plasma FIB dual-beam microscopes have made 3D EBSD studies all the more feasible. The objective of this work is to apply high angular resolution cross correlation EBSD to a 3D EBSD data set collected by serial sectioning in a FIB to characterize dislocation interaction with a grain boundary. Three dimensional high angular resolution cross correlation EBSD analysis was applied to an AlCu oligocrystal to measure dislocation densities around a grain boundary. Distortion derivatives associated with the plasma FIB serial sectioning were higher than expected, possibly due to geometric uncertainty between layers. Future work will focus on mitigating the geometric uncertainty and examining more regions of interest along the grain boundary to glean information on dislocation-grain boundary interaction.

Ruggles, Timothy↗