Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parabolic Flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics, including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics in weightlessness is limited to the left IJV assessed ~45 and ~150 days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness and therefore a risk for short-duration missions and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we investigated the effects of acute weightlessness during parabolic flight on the right and left IJV in 12 healthy subjects. Baseline ultrasound images were obtained on the ground (1g) in the seated and supine postures and during 0g parabolic flight. Each data collection session included 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the bilateral IJVs. RESULTS There was a similar pattern of response in the left and right IJV area across postures and g-levels. IJV area increased from seated to supine by 0.74 mm2 (95% CI: 0.56 to 0.91 mm2, p<.001) and increased further during weightlessness by 0.29 mm2 (95% CI: 0.11 to 0.47 mm2, p=.0015). IJV Doppler images revealed stagnant flow in the left IJV in one subject during 0g exposure that was not present during any imaging on the ground; the right IJV continued to show pulsatile, nominal flow patterns in both 0g and 1g. CONCLUSIONS This study characterized the immediate effect of the weightlessness-induced headward fluid shift on venous parameters in the left and right IJV. The left IJV appears to be more susceptible to flow alterations, including stagnant flow, during both short and long-duration exposure to weightlessness that may contribute to the risk of thrombosis inflight.

K Marshall-Goebel↗

Evaluation of cardiopulmonary resuscitation techniques in microgravity

Cardiopulmonary resuscitation (CPR) techniques were investigated in microgravity with specific application to planned medical capabilities for Space Station Freedom (SSF). A KC-135 parabolic flight test was performed with the goal of evaluating and quantifying the efficacy of different types of microgravity CPR techniques. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. Three experiments were involved chosen for their clinical background, certification, and practical experience in prior KC-135 parabolic flight. The CPR evaluation was performed using a standard training mannequin (recording resusci-Annie) which was used in practice prior to the actual flight. Aboard the KC-135, the prototype medical restraint system (MRS) for the SSF Health Maintenance Facility (HMF) was used for part of the study. Standard patient and crew restraints were used for interface with the MRS. During the portion of study where CPR was performed without MRS, a set of straps for crew restraint similar to those currently employed for the Space Shuttle program were used. The entire study was recorded via still camera and video.

Billica, Roger↗

Vestibular function in the space environment

The present work presents new results about the interdependence of optical illusory sensations and eye movements in man. To establish to what degree certain illusions previously obtained during centrifugation and parabolic flight can be explained by eye movements and by neuronal integration in the brain, real eye movements were measured as they occurred in the dark without optical fixation, during rectilinear accelerations on the ground, and during weightlessness in parabolic flight. Results provide valuable insight into normal vestibular function as well as resolution of within-the-eye and behind-the-eye contributions to the above illusions.

Von Baumgarten, R. J.↗

Microgravity Apparatus And Ground-Based Study Of The Flame Propagation And Quenching In Metal Dust Suspensions

Due to particle sedimentation and relatively low laminar flame speeds in dust suspensions, microgravity environment is essential for the observation of laminar dust flames in a wide range of particle sizes and fuel concentrations [1]. The capability of a reduced-gravity environment to facilitate study of dust combustion was realized by researchers long before current microgravity programs were established by the various national Space Agencies. Thus, several experimentalists even built their own, albeit very short-duration, drop tower facilities to study flames in particle and droplet suspensions [2,3]. About ten years ago, authors of the present paper started their dust combustion reduced gravity research with the investigation of the constant volume dust flames in a spherical-bomb on board a parabolic flight aircraft [4]. However it was soon realized that direct observation of the constant-pressure flame might be more beneficial. Thus, microgravity apparatus, permitting examination of the freely propagating flames in open-end tubes, was tested in parabolic flights three years later [5]. The improved design of the newlyconstructed apparatus for the experiments on board the NASA KC-135 aircraft is also based on the observation of the dust flame propagating in semi-opened tubes with free expansion of the combustion products that are continuously vented overboard. The apparatus design and results of its extensive ground-based testing are presented below.

Goroshin, Sam↗

Microgravity Effecs During Fertilization, Cell Division, Development, and Calcium Metabolism in Sea Urchins

Calcium loss and muscle atrophy are two of the main metabolic changes experienced by astronauts and crew members during exposure to microgravity in space. For long-term exposure to space it is crucial to understand the underlying mechanisms for altered physiological functions. Fundamental occurrences in cell biology which are likely to depend on gravity include cytoskeletal dynamics, chromatin and centrosome cycling, and ion immobilization. These events can be studied during fertilization and embryogenesis within invertebrate systems. We have chosen the sea urchin system to study the effects of microgravity on cytoskeletal processes and calcium metabolism during fertilization, cell division, development, and embryogenesis. Experiments during an aircraft parabolic flight (KC-135) demonstrated: (1) the viability of sea urchin eggs prior to fertilization, (2) the suitability of our specimen containment system, (3) the feasibility of fertilization in a reduced gravity environment (which was achieved during 25 seconds of reduced gravity under parabolic flight conditions). Two newly developed pieces of spaceflight hardware made further investigations possible on a spaceflight (STS-77); (1) the Aquatic Research Facility (ARF), and (2) the Fertilization Syringe Unit (FSU). The Canadian Space Agency developed ARF to conduct aquatic spaceflight experiments requiring controlled conditions of temperature, humidity, illumination, and fixation at predetermined time points. It contained a control centrifuge which simulated the 1 g environment of earth during spaceflight. The FSU was developed at the Kennedy Space Center (KSC) by the Bionetics Corporation specifically to enable the crew to perform sea urchin fertilization operations in space.

Schatten, Heide↗

An analysis of human performance in simulated partial-gravity environments

Three unique partial gravity test environments; parabolic flight, water immersion and a mechanical-relief device provide the environment to evaluate human locomotion, reach sweeps, and posture in the reduced gravity levels of the moon (1/6) and Mars (3/8). The development of a motion analysis database for 1/6 and 3/8 gravity environments as well as an initial understanding of human motion in low gravity environments are the focus of these experiments. Each of the three partial-gravity simulations provided a unique environment with some specific limitations. Water immersion provides a continuous testing environment but must factor in the effects of water viscosity drag, subject weighting, and breathing apparatus. Parabolic flight provides the most realistic testing environment although the test must be interrupted every 40 seconds to execute a complete parabolic maneuver of the aircraft. Mechanical force relief systems also provide uninterrupted testing. However, the body support harness necessary for use of mechanical force relief systems can potentially hinder test subject movement. By using the test results generated from all three test arenas, the Man-Systems Division will create a database of human locomotion specific to the lunar and Mars gravity environments. The information gathered is being used to enhance the development and design of future human habitation elements.

Moore, Nathan R.↗

Microgravity combustion of dust suspensions

Unlike the combustion of homogeneous gas mixtures, there are practically no reliable fundamental data (i.e., laminar burning velocity, flammability limits, quenching distance, minimum ignition energy) for the combustion of heterogeneous dust suspensions. Even the equilibrium thermodynamic data such as the constant pressure volume combustion pressure and the constant pressure adiabatic flame temperature are not accurately known for dust mixtures. This is mainly due to the problem of gravity sedimentation. In normal gravity, turbulence, convective flow, electric and acoustic fields are required to maintain a dust in suspension. These external influences have a dominating effect on the combustion processes. Microgravity offers a unique environment where a quiescent dust cloud can in principle be maintained for a sufficiently long duration for almost all combustion experiments (dust suspensions are inherently unstable due to Brownian motion and particle aggregation). Thus, the microgravity duration provided by drop towers, parabolic flights, and the space shuttle, can all be exploited for different kinds of dust combustion experiments. The present paper describes some recent studies on microgravity combustion of dust suspension carried out on the KC-135 and the Caravelle aircraft. The results reported are obtained from three parabolic flight campaigns.

Lee, John H. S.↗

MPCV Exercise Operational Volume Analysis

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

mathematical models↗

Effects of gravitoinertial force variations on optokinetic nystagmus and on perception of visual stimulus orientation

Recordings of horizontal and vertical eye movement were obtained with subjects exposed to vertical, horizontal, and oblique optokinetic stimulation during parabolic flight. When the optokinetic stimulation was vertical, the upward slow phase eye velocity increased increased during transition from high force level to free-fall, and decreased during transition from free-fall to high force level. During optokinetic stimulation in the horizontal and oblique plane, the gravitoinertial forces of parabolic flight induced changes in the velocity of the vertical component of the eye movements, and, therefore, changes in the plane of the eye movements. Some subjects also preceived modifications in the apparent orientation of the visual motion. These findings are in agreement with previous observations on the presence of a vertical nystagmus induced by changes in plane vertical acceleration. They also suggest a close interaction of reflexive eye movements induced by graviceptor inputs and visual inputs for visual stabilization during variations of gravitoinertial force level.

Clement, Gilles↗

Surgical Instrument Restraint in Weightlessness

Performing a surgical procedure during spaceflight will become more likely with longer duration missions in the near future. Minimal surgical capability has been present on previous missions as the definitive medical care time was short and the likelihood of surgical events too low to justify surgical hardware availability. Early demonstrations of surgical procedures in the weightlessness of parabolic flight indicated the need for careful logistical planning and restraint of surgical hardware. The consideration of human ergonomics also has more impact in weightlessness than in the conventionall-g environment. Three methods of surgical instrument restraint - a Minor Surgical Kit (MSK), a Surgical Restraint Scrub Suit (SRSS), and a Surgical Tray (ST) were evaluated in parabolic flight surgical procedures. The Minor Surgical Kit was easily stored, easily deployed, and demonstrated the best ability to facilitate a surgical procedure in weightlessness. Important factors in this surgical restraint system include excellent organization of supplies, ability to maintain sterility, accessibility while providing secure restraint, ability to dispose of sharp items and biological trash, and ergonomical efficiency.

Campbell, Mark R.↗

Thermosyphon Flooding in Reduced Gravity Environments Test Results

The condenser flooding phenomenon associated with gravity aided two-phase thermosyphons was studied using parabolic flights to obtain the desired reduced gravity environment (RGE). The experiment was designed and built to test a total of twelve titanium water thermosyphons in multiple gravity environments with the goal of developing a model that would accurately explain the correlation between gravitational forces and the maximum axial heat transfer limit associated with condenser flooding. Results from laboratory testing and parabolic flights are included in this report as part I of a two part series. The data analysis and correlations are included in a follow on paper.

Gibson, Marc A.↗

Spatial Coding of Eye Movements Relative to Perceived Orientations During Roll Tilt with Different Gravitoinertial Loads

This purpose of this study was to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness from six subjects allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. Both variability and curvature of gaze trajectories increased during roll tilt compared to the upright position. The saccades were less accurate during parabolic flight compared to measurements obtained in normal gravity. The trajectories of saccades along perceived horizontal orientations tended to deviate in the same direction as the head tilt, while the deviations in gaze trajectories along the perceived vertical orientations deviated in the opposite direction relative to the head tilt. Although subjects were instructed to look off in the distance while performing the eye movements, fixation distance varied with vertical gaze direction independent of whether the saccades were made along perceived aircraft or head orientations. This coupling of horizontal vergence with vertical gaze is in a consistent direction with the vertical slant of the horopter. The increased errors in gaze trajectories along both perceived orientations during microgravity can be attributed to the otolith's role in spatial coding of eye movements.

Wood, Scott↗

Prediction of the space adaptation syndrome

The univariate and multivariate relationships of provocative measures used to produce motion sickness symptoms were described. Normative subjects were used to develop and cross-validate sets of linear equations that optimally predict motion sickness in parabolic flights. The possibility of reducing the number of measurements required for prediction was assessed. After describing the variables verbally and statistically for 159 subjects, a factor analysis of 27 variables was completed to improve understanding of the relationships between variables and to reduce the number of measures for prediction purposes. The results of this analysis show that none of variables are significantly related to the responses to parabolic flights. A set of variables was selected to predict responses to KC-135 flights. A series of discriminant analyses were completed. Results indicate that low, moderate, or severe susceptibility could be correctly predicted 64 percent and 53 percent of the time on original and cross-validation samples, respectively. Both the factor analysis and the discriminant analysis provided no basis for reducing the number of tests.

Reschke, M. F.↗

A Multidisciplinary Modeling Approach of Plant Gas Exchange in Reduced Gravity Environments

In-situ food production is a necessary step for human exploration of the solar system and requires a deep understanding of plant growth in reduced gravity environments. In particular, the lack of buoyancy-driven convection changes the gas exchange at the leaf surface, which decreases photosynthesis and transpiration rates, and ultimately biomass production. To understand the intricate relations between physical, chemical, and biochemical processes, the following methodology combines the development of a mechanistic model of plant growth in reduced gravity environments, computational fluid dynamics (CFD) simulations, and experiments in different time frames.The model presented here is a coupled mass and energy balance using the single round leaf assumption, including gravity as an entry parameter, and the leaf surface temperature as an output variable. Measures of the leaf surface temperature using infra-red cameras allow for a computation of the transpiration rate. This approach was followed to design a parabolic flight experiment, which performed 7 flights, and enabled data collection for model validation in different gravity and ventilation settings on a short time frame. Current measures of carbon assimilation and transpiration rate at the leaf and canopy level using an infra-red gas analyzer (Li-6800) in 1g lab conditions on several species will enable a validation on longer time frames and further calibration of the model. CFD studies both on the parabolic flight and on the lab experimental set-up allow the precise assessment of ventilation above the canopy and plants' leaves.Ultimately, this work will provide recommendations for the design of future plant growth hardware, especially on the lowest adequate ventilation for optimal plant growth in reduced gravity environments, as well as assessing biomass and oxygen production rates on planetary surfaces and space stations. This work was funded by CNES, CNRS, Clermont Auvergne Metropole, and NASA Space Biology through NASA postdoctoral program / USRA.

Poulet, Lucie↗

Evaluation of prototype air/fluid separator for Space Station Freedom Health Maintenance Facility

A prototype air/fluid separator suction apparatus proposed as a possible design for use with the Health Maintenance Facility aboard Space Station Freedom (SSF) was evaluated. A KC-135 parabolic flight test was performed for this purpose. The flights followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. A protocol was prepared to evaluate the prototype device in several regulator modes (or suction force), using three fluids of varying viscosity, and using either continuous or intermittent suction. It was felt that a matrixed approach would best approximate the range of utilization anticipated for medical suction on SSF. The protocols were performed in one-gravity in a lab setting to familiarize the team with procedures and techniques. Identical steps were performed aboard the KC-135 during parabolic flight.

Billica, Roger↗

Electrodeposition of Metals in Microgravity Conditions

Metal electrodeposition may introduce various morphological variations depending on the electrolytic conditions including cell configurations. For liquid electrolytes, a precise study of these deposits may be complicated by convective motion due to buoyancy. Zero-gravity (0-G) condition provided by drop shaft or parabolic flight gives a straightforward mean to avoid this effect: we present here 0-G electrodeposition experiments, which we compare to ground experiments (1-G). Two electrochemical systems were studied by laser interferometry, allowing to measure the concentration variations in the electrolyte: copper deposition from copper sulfate aqueous solution and lithium deposition from an ionic liquid containing LiTFSI. For copper, concentration variations were in good agreement with theory. For lithium, an apparent induction time was observed for the concentration evolution at 1-G: due to this induction time and to the low diffusion coefficient in ionic liquid, the concentration variations were hardly measurable in the parabolic flight 0-G periods of 20 seconds.

Nishikawa, K.↗

Surgical bleeding in microgravity

A surgical procedure performed during space flight would occur in a unique microgravity environment. Several experiments performed during weightlessness in parabolic flight were reviewed to ascertain the behavior of surgical bleeding in microgravity. Simulations of bleeding using dyed fluid and citrated bovine blood, as well as actual arterial and venous bleeding in rabbits, were examined. The high surface tension property of blood promotes the formation of large fluid domes, which have a tendency to adhere to the wound. The use of sponges and suction will be adequate to prevent cabin atmosphere contamination with all bleeding, with the exception of temporary arterial droplet streams. The control of the bleeding with standard surgical techniques should not be difficult.

short duration↗

Lessons Learned from Performance Testing of Humans in Spacesuits in Simulated Reduced Gravity

Introduction: The overarching objective of the Integrated Suit Test (IST) series is to evaluate suited human performance using reduced-gravity analogs and learn what aspects of an EVA suit system affect human performance. For this objective to be successfully achieved, the testing methodology should be valid and reproducible, and the partial-gravity simulations must be as accurate and realistic as possible. Objectives: To highlight some of the key lessons learned about partial-gravity analogs and testing methodology, and to suggest considerations for optimizing the effectiveness and quality of results of future tests. Methods: Performance testing of suited and unsuited subjects was undertaken in different reduced-gravity analogs including the Space Vehicle Mockup Facility s Partial Gravity Simulator (POGO), parabolic flight on the C-9 aircraft, underwater environments including NASA s Extreme Environment Mission Operations (NEEMO) and the Neutral Buoyancy Lab (NBL), and in field analogs including Desert Research and Technology Studies (RATS), the Haughton Mars Project (HMP), and the JSC Rock Pile. Subjects performed level walking, incline/decline walking, running, shoveling, picking up and transferring rocks, kneeling/standing, and task boards. Lessons Learned Analogs: No single analog will properly simulate all aspects of the true partial-gravity environment. The POGO is an ideal environment from the standpoint that there are no time limits or significant volumetric constraints, but it does have several limitations. It allows only 2 translational degrees of freedom (DOF) and applies true partial-gravity offload only through the subject s center of gravity (CG). Also, when a subject is doing non-stationary tasks, significant overhead inertia from the lift column seems to have a negative impact on performance. Parabolic flight allows full translational and rotational DOF and applies offload to all parts of the body, but the simulation lasts less than 30 seconds. When this is coupled with the volumetric constraints of the plane, both task selection and data collection options are significantly limited. The underwater environments also allow all 6 DOF and allow off-loading to be applied throughout the body, but the data collection capabilities are limited to little more than subjective ratings. In addition, water drag negatively affects performance of tasks requiring dynamic motion. Field analogs provide the ability to simulate lunar terrain and more realistic mission-like objectives, but all of them operate at 1-g, so suited human performance testing generally must utilize a reduced-mass or "mockup" suit, depending on study objectives. In general, the ground-based overhead-suspension partial-gravity analogs like POGO allow the most diverse data collection methods possible while still simulating partial gravity. However, as currently designed, the POGO has significant limitations. Design of the Active Response Gravity Offload System (ARGOS) has begun and is focusing on adding full x,y,z translational DOF, improved offload accuracy, increased lift capacity, and active control of the x and y axes to minimize offload system inertia. Additionally, a new gimbal is being designed to reduce mass and inertia and to be able to work with different suits, as the current gimbal only supports suited testing with the Mark III Technology Demonstrator Suit (MKIII).

Norcross, Jason R.↗