Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Assessing the Performance and Impact of PV Technologies on Storage in Hybrid Renewable Systems

Traditional monofacial photovoltaic (mPV) systems are commonly adopted and well-documented because of their lower upfront costs in comparison to bifacial photovoltaic (bPV) systems. This study investigates how PV technologies impact energy storage in grid-scale hybrid renewable systems, focusing on optimizing and assessing the performance of mPV and bPV technologies integrated with pumped storage hydropower. Using Ludington City, Michigan as a case study and analyzing real-world data such as solar irradiance, ambient temperature, and utility-scale load profiles, the research highlights the operational and economic benefits of bPV systems. The results reveal that bPV systems can pump approximately 10.38% more water annually to the upper reservoir while achieving a lower levelized cost of energy ($0.0578/kWh for bPV vs. $0.0672/kWh for mPV). This study underscores the outstanding potential of bPV systems in enhancing energy storage and management strategies, contributing to a more sustainable and resilient renewable energy future.

13 HYDRO ENERGY↗

The Baseline Performance Reference for Irradiance in PV System Applications

This report proposes the definition of a new baseline performance reference (BPR). The definition goes beyond existing standards pertaining to photovoltaic (PV) reference cells and devices to define the response under all possible operating conditions in the field. Field evaluations using BPR devices will be more sensitive to performance anomalies than pyranometers because they track PV system power output more closely. At the same time, they will be able to detect a broader range of performance anomalies than traditional matched reference devices, which might have matching defects. The BPR definition also opens the door to new practices in resource assessment and yield prediction. Solar resource data can be collected or modeled and validated directly as BPR irradiance, and PV system simulations based on BPR irradiance need fewer assumptions and less processing to obtain the effective irradiance on modules. As a result, lower uncertainty in yield assessments can be expected.

14 SOLAR ENERGY↗

Spectral Effects in Albedo and Rearside Irradiance Measurement for Bifacial Performance Estimation

We investigate the impact of spectral dependence of ground surface reflectivity on albedo and rearside irradiance measurements necessary for bifacial photovoltaic (PV) module performance estimation and monitoring. Because PV modules are spectrally selective, albedo and irradiance measurements performed with common irradiance sensors may require spectral mismatch corrections when used for performance prediction. We investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystalline silicon PV reference cells in comparison to a typical crystalline-silicon bifacial PV module. Simulations are performed for nine different representative ground surface materials using simulated solar spectra together with spectral reflectivity data distributed with the SMARTS simulation software. For the materials considered, the results show that albedo spectral mismatch relative to the bifacial module is distributed over a range of ±9.2% for thermopile pyranometers versus only ±3.7% for a typical PV reference cell. We consider the impact of this spectrally-responsive albedo mismatch on bifacial PV module rearside irradiance measurements. Using synthesized rearside spectral irradiance distributions, we find that for the nine different ground surface materials the predicted rearside irradiance measurement deviates from the effective irradiance observed by the PV module by on the order of 16.5 W/m 2 for the pyranometer and 3.6 W/m 2 for the PV reference cell. We discuss the implications for bifacial albedo and irradiance measurement.

41 EE - Solar Energy Technologies Office (EE-4S)↗

BACKFLIP: Identification of Materials and Changes Upon Aging of Emerging Fluoropolymer-Free and Industry-Benchmark PV Backsheets

Extending lifetimes of photovoltaic (PV) modules and decreasing manufacturing and decommissioning costs are motivating research of novel PV module backsheet materials. Backsheet integrity is critical to the safety and performance of a PV module, however, the polymeric materials are often vulnerable to environmental degradation. The long-term durability of emerging polyolefin (PO) materials is being examined to inform regarding the possible replacement of laminated backsheets containing polyethylene terephthalate (PET) cores and fluoropolymer protective inner/outer layers. This study compares traditional PET-based backsheets with novel, co-extruded, and recyclable PO-based backsheets after being subjected to hygrometric and UV photolytic accelerated weathering. A large set of characterization methods will compare physical, chemical, structural, mechanical, and insulating properties of these backsheets and the resulting mini-module (MiMo) PV performances. The study of chemical composition, glass- and phase-transition temperatures, degree of crystallinity, and crystalline structure are described here.

mini-module↗

Bifacial Photovoltaic Modules and Systems: Experience and Results from International Research and Pilot Applications

Within the framework of IEA PVPS, Task 13 aims to provide support to market actors working to improve the operation, the reliability and the quality of PV components and systems. Operational data from PV systems in different climate zones compiled within the project will help provide the basis for estimates of the current situation regarding PV reliability and performance. The general setting of Task 13 provides a common platform to summarize and report on technical aspects affecting the quality, performance, reliability and lifetime of PV systems in a wide variety of environments and applications. By working together across national boundaries we can all take advantage of research and experience from each member country and combine and integrate this knowledge into valuable summaries of best practices and methods for ensuring PV systems perform at their optimum and continue to provide competitive return on investment. Task 13 has so far managed to create the right framework for the calculations of various parameters that can give an indication of the quality of PV components and systems. The framework is now there and can be used by the industry who has expressed appreciation towards the results included in the high-quality reports. The IEA PVPS countries participating in Task 13 are Australia, Austria, Belgium, Canada, Chile, China, Denmark, Finland, France, Germany, Israel, Italy, Japan, the Netherlands, Norway, Spain, Sweden, Switzerland, Thailand, and the United States of America.

14 SOLAR ENERGY↗

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Soiling, the accumulation of dust and other contaminants on the surface of photovoltaic (PV) modules, is a common factor that can negatively impact the performance of PV systems. In this study, the authors aim to analyze the impact of pollen on soiling losses in PV systems located in North Carolina, USA, particularly during the spring season. The performance data of two utility-scale PV plants was collected and analyzed using the two soiling extraction methods. Environmental data, including croplands and vegetation was also collected and analyzed to identify correlations with soiling losses. The results of the study may help improve understanding of necessary operation and maintenance activities for PV plants and provide new insights into the phenomenon of pollen deposition on PV systems.

correlation↗

Performance Improvements Through Advanced PV Backtracking on Uneven Terrain

The climatic sensitivity of new terrain-aware backtracking algorithms is evaluated across 800 locations in the continental USA on a representative synthetic rolling terrain. We find that a global optimization approach to backtracking results in climate-specific annual energy gains of 2.4%–3.2% relative to a traditional backtracking algorithm baseline. We identify a strong logarithmic correlation between local diffuse fraction and yield improvement, and highlight the effect of seasonal precipitation on performance gains. We also find that a backtracking approach, which approximates the terrain as constant, does not offer significant annual energy gains over the baseline on the synthetic terrain. Our findings suggest that specific yield from backtracking in the USA can be improved by as much as 88 kWh/kW by considering terrain when selecting a backtracking algorithm.

Backtracking↗

Photovoltaic Data Acquisition (PVDAQ) Public Datasets

The NREL PVDAQ is a large-scale time-series database containing system metadata and performance data from a variety of experimental PV sites and commercial public PV sites. The datasets are used to perform on-going performance and degradation analysis. Some of the sets can exhibit common elements that effect PV performance (e.g. soiling). The dataset consists of a series of files devoted to each of the systems and an associated set of metadata information that explains details about the system hardware and the site geo-location. Some system datasets also include environmental sensors that cover irradiance, temperatures, wind speeds, and precipitation at the site.

Array↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

HelioScope Energy Performance Modeling Validation: Cooperative Research and Development Final Report, CRADA Number CRD-17-00685

HelioScope is a unique solar design and energy performance modeling tool that bridges the worlds of research and industry, bringing the most rigorous methods from the performance modeling community to thousands of solar developers of all backgrounds. However, many financial institutions and municipalities are hesitant to accept the energy production modeling results of HelioScope (including shading losses) in place of costly, time-intensive, and/or redundant methods due to lack of vetting from a respected institution like NREL. We expect that the proposed validation exercises will give municipalities and financial institutions the comfort needed to incorporate HelioScope into their operations, thereby significantly reducing the needs of existing and potential HelioScope users' to otherwise obtain information that HelioScope produces automatically. Folsom Labs was selected for a Small Business Voucher from the U.S. Department of Energy for the National Renewable Energy Laboratory to validate the performance of HelioScope’s simulation engine against measured PV system performance.

14 SOLAR ENERGY↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Resilience Metrics for Solar Photovoltaics

This workshop presentation proposes the development of solar photovoltaic (PV) system resilience metrics and a methodology and framework for evaluation of PV resilience metrics. PV resilience metrics are needed to establish a consistent basis for reporting, evaluation, and data collection by industry, evaluate performance of PV systems that have been subject to natural hazards, correlating resilience to system attributes, and predicting resilience for any PV system. PV resilience metrics can guide improved system design, standards, and insurance coverage. Establishing consistent metrics can foster data collection on impacts of natural hazards on PV systems.

14 SOLAR ENERGY↗

High-Performance Passivating Contacts for Si PV Based on Engineered, Doped Nanopinholes through Dielectric Layers

We present a novel, industrially relevant method to fabricate high-performance poly-Si passivating contacts for Si PV. Passivating contacts based on SiOx/poly-Si layer stacks have been implemented in record-efficiency homojunction Si solar cells. In this technology, the carrier transport through a surface-passivating SiOx is enabled either by quantum-tunneling or nanopinholes. The doped poly-Si layer provides charge-carrier selectivity. Previously, the ISFH research group demonstrated a record 26.1% efficient Si homojunction cell, where transport pinholes in ~2 nm SiOx were produced by thermal breakdown at > 1000 degrees C, which is hard to control and is surface morphology-dependent. At room temperature, our new process uses electroless plating of Ag nanoparticles, followed by metal-assisted chemical etching. Nanogalvanic corrosion yields < 20 nm-wide nanopinholes in an insulating > 2 nm SiOx layer. The nanopinholes are filled by a heavily doped a-Si:H overlayer. We drive in the dopants into the Si wafer with subsequent high-temperature annealing. Preferential incorporation of dopants at pinhole locations results in nanoscale p+/n or n+/n junctions near the wafer interface. Each heavily-doped nanoscale pinhole junction collects and transports photogenerated carriers to the cell metal contacts. The density of the engineered nanopinholes can be tuned over a wide range which is critical for optimization of device performance. The same nanogalvanic corrosion principles can be applied to produce doped transport pinholes in well-passivating thick dielectric SiOx/SiNy stacks. Importantly, our process does not rely on thermal breakdown of the dielectric layers and can be applied to textured wafers resulting in Si solar cells with > 20% conversion efficiency.

dielectric layer↗

Situated Visualization of Photovoltaic Module Performance for Workforce Development

The rapid growth of the solar energy industry requires advanced educational tools to train the next generation of engineers and technicians. We present a novel system for situated visualization of photovoltaic (PV) module performance, leveraging a combination of PV simulation, sun-sky position, and head-mounted augmented reality (AR). Our system is guided by four principles of development: simplicity, adaptability, collaboration, and maintainability, realized in six components. Users interactively manipulate a physical module's orientation and shading referents with immediate feedback on the module's performance.

augmented reality↗

Situated Visualization of Photovoltaic Module Performance for Workforce Development

The rapid growth of the solar energy industry requires advanced educational tools to train the next generation of engineers and technicians. We present a novel system for situated visualization of photovoltaic (PV) module performance, leveraging a combination of PV simulation, sun-sky position, and head-mounted augmented reality (AR). Our system is guided by four principles of development: simplicity, adaptability, collaboration, and maintainability, realized in six components. Users interactively manipulate a physical module's orientation and shading referents with immediate feedback on the module's performance.

augmented reality↗