Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PPt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Temperature stability of ([Na{sub 0.5}K{sub 0.5}NbO{sub 3}]{sub 0.93}-[LiTaO{sub 3}]{sub 0.07}) lead-free piezoelectric ceramics

A polymorphic phase transition (PPT) is often engineered into lead-free materials to generate high piezoelectric activity at room temperature, limiting their temperature stability. We report [Na{sub 0.5}K{sub 0.5}NbO{sub 3}]{sub 0.93}-[LiTaO{sub 3}]{sub 0.07} tetragonal ceramics with favorable properties over a broad temperature range due to a high Curie temperature at 447 deg. C and PPT at -15 deg. C involving a transition to a monoclinic rather than low temperature orthorhombic phase. Piezoelectric k{sub 31} and d{sub 31} coefficients varied from 0.19 to 0.14 and -53 to -33 pC/N, respectively, over the range of -15 to 300 deg. C. Strain-electric field loops provided strains of {approx}0.2% and a high-field d{sub 33} of 205 pm/V.

36 MATERIALS SCIENCE↗

Reduction Of Chronic Musculoskeletal Pain With Cranial Laser Reflex Technique (CLRT): A Randomized Controlled Trial Using Pressure Algometry

Cranial Laser Reflex Technique (CLRT) is a novel method involving a brief low level laser stimulation of specific cranial reflex points to reduce musculoskeletal pain. Objective: The objective of the study was to compare the immediate effects of CLRT with a sham treatment on chronic musculoskeletal pain using pressure algometry in a double-blinded randomized controlled trial. Methods: Fifty-seven (57) volunteers with various musculoskeletal pains gave informed consent and were randomly allocated to either the CLRT treatment or sham group. Painful trigger points and/or tender spinal joints were found in each patient. Using a digital algometer, the pain/pressure threshold (PPT) was determined and a pain rating was given using a numerical pain scale from 0-10. CLRT or a sham treatment was performed with a 50 mW, 840 nm laser, for a maximum of 20 seconds to the each cranial reflex. The initial pressure (PPT) was immediately delivered to the same spot, and the pain rated again. Results: There was a statistically significant difference in pain scores between CLRT and sham groups immediately following treatment. Improvement was reported in 95% of the treatment group, with 59% reporting an improvement of 2 points or greater. The average change in pain scores in the treatment group was 2.6 points (p 0.000) versus negligible change (p= 0.4) for the control group. Conclusion: The results show that CLRT is effective at immediately reducing chronic musculoskeletal pain. Further studies are needed with additional outcome measures to.

60 APPLIED LIFE SCIENCES↗

A portable optical emission spectroscopy-cavity ringdown spectroscopy dual-mode plasma spectrometer for measurements of environmentally important trace heavy metals: Initial test with elemental Hg

A portable optical emission spectroscopy-cavity ringdown spectroscopy (OES-CRDS) dual-mode plasma spectrometer is described. A compact, low-power, atmospheric argon microwave plasma torch (MPT) is utilized as the emission source when the spectrometer is operating in the OES mode. The same MPT serves as the atomization source for ringdown measurements in the CRDS mode. Initial demonstration of the instrument is carried out by observing OES of multiple elements including mercury (Hg) in the OES mode and by measuring absolute concentrations of Hg in the metastable state 6s6p {sup 3}P{sub 0} in the CRDS mode, in which a palm-size diode laser operating at a single wavelength 405 nm is incorporated in the spectrometer as the light source. In the OES mode, the detection limit for Hg is determined to be 44 parts per 10{sup 9} (ppb). A strong radiation trapping effect on emission measurements of Hg at 254 nm is observed when the Hg solution concentration is higher than 50 parts per 10{sup 6} (ppm). The radiation trapping effect suggests that two different transition lines of Hg at 253.65 nm and 365.01 nm be selected for emission measurements in lower (<50 ppm) and higher concentration ranges (>50 ppm), respectively. In the CRDS mode, the detection limit of Hg in the metastable state 6s6p {sup 3}P{sub 0} is achieved to be 2.24 parts per 10{sup 12} (ppt) when the plasma is operating at 150 W with sample gas flow rate of 480 mL min{sup -1}; the detection limit corresponds to 50 ppm in Hg sample solution. Advantage of this novel spectrometer has two-fold, it has a large measurement dynamic range, from a few ppt to hundreds ppm and the CRDS mode can serve as calibration for the OES mode as well as high sensitivity measurements. Measurements of seven other elements, As, Cd, Mn, Ni, P, Pb, and Sr, using the OES mode are also carried out with detection limits of 1100, 33, 30, 144, 576, 94, and 2 ppb, respectively. Matrix effect in the presence of other elements on Hg measurements has been found to increase the detection limit to 131 ppb. These elements in lower concentrations can also be measured in the CRDS mode when a compact laser source is available to be integrated into the spectrometer in the future. This exploratory study demonstrates a new instrument platform using an OES-CRDS dual-mode technique for potential field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiopurity measurement of acrylic for DEAP-3600

The spherical acrylic vessel that contains the liquid argon target is the most critical detector component in the DEAP-3600 dark matter experiment. Alpha decays near the inner surface of the acrylic vessel are one of the main sources of background in the detector. A fraction of the alpha energy, or the recoiling nucleus from the alpha decay, could misreconstruct in the fiducial volume and result in a false candidate dark matter event. Acrylic has low levels of inherent contamination from {sup 238}U and {sup 232}Th. Another background of particular concern is diffusion of {sup 222}Rn during manufacturing, leading to {sup 210}Pb contamination. The maximum acceptable concentrations in the DEAP-3600 acrylic vessel are ppt levels of {sup 238}U and {sup 232}Th equivalent, and 10{sup −8} ppt {sup 210}Pb. The impurities in the bulk acrylic will be measured by vaporizing a large quantity of acrylic and counting the concentrated residue with ultra-low background HPGe detectors and a low background alpha spectrometer. An overview of the acrylic assay technique is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An atom trap trace analysis system for measuring krypton contamination in xenon dark matter detectors

We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since Ar and Kr have similar laser cooling wavelengths, the apparatus has been tested with Ar to avoid contamination prior to measuring Xe samples. A radio-frequency plasma discharge generates a beam of metastable atoms which is optically collimated, slowed, and trapped using standard magneto-optical techniques. Based on the measured overall system efficiency of 1.2 × 10{sup −8} (detection mode), we expect the ATTA system to reach the design goal sensitivity to ppt concentrations of Kr in Xe in <2 h.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation on transition behavior and electrical properties of (K{sub 0.5}Na{sub 0.5}){sub 1-x}Li{sub x}Nb{sub 0.84}Ta{sub 0.1}Sb{sub 0.06}O{sub 3} around polymorphic phase transition region

(K{sub 0.5}Na{sub 0.5}){sub 1-x}Li{sub x}Nb{sub 0.84}Ta{sub 0.1}Sb{sub 0.06}O{sub 3} (KNLNTS) lead free ceramics with different Li concentration were fabricated by conventional solid-state reaction method. By increasing Li ions in KNLNTS, the grains grow up and the crystal structure changes from orthorhombic to tetragonal. When 0.03 ≤ x ≤ 0.05, the ceramics structure lays in PPT region. Polarization versus electric field (P-E) hysteresis loops at room temperature show good ferroelectric properties and the remnant polarization decreases by increasing Li content while coercive electric keeps almost unchanged. In PPT region, taking x = 0.04 as an example, the sample shows excellent dielectric properties: the dielectric constant is 1159 and loss tangent is 0.04, while the piezoelectric constant d{sub 33} is 245 pC/N and kp is 0.44 at room temperature, it is promising for (K{sub 0.5}Na{sub 0.5}){sub 1-x}Li{sub x}Nb{sub 0.84}Ta{sub 0.1}Sb{sub 0.06}O{sub 3} with 4 at. % Li to substitute PZT.

36 MATERIALS SCIENCE↗

Effect of number of stack on the thermal escape and non-radiative and radiative recombinations of photoexcited carriers in strain-balanced InGaAs/GaAsP multiple quantum-well-inserted solar cells

Three non-destructive methodologies, namely, surface photovoltage (SPV), photoluminescence, and piezoelectric photothermal (PPT) spectroscopies, were adopted to detect the thermal carrier escape from quantum well (QW) and radiative and non-radiative carrier recombinations, respectively, in strain-balanced InGaAs/GaAsP multiple-quantum-well (MQW)-inserted GaAs p-i-n solar cell structure samples. Although the optical absorbance signal intensity was proportional to the number of QW stack, the signal intensities of the SPV and PPT methods decreased at high number of stack. To explain the temperature dependency of these signal intensities, we proposed a model that considers the three carrier dynamics: the thermal escape from the QW, and the non-radiative and radiative carrier recombinations within the QW. From the fitting procedures, it was estimated that the activation energies of the thermal escape ΔE{sub barr} and non-radiative recombination ΔE{sub NR} were 68 and 29 meV, respectively, for a 30-stacked MQW sample. The estimated ΔE{sub barr} value agreed well with the difference between the first electron subband and the top of the potential barrier in the conduction band. We found that ΔE{sub barr} remained constant at approximately 70 meV even with increasing QW stack number. However, the ΔE{sub NR} value monotonically increased with the increase in the number of stack. Since this implies that non-radiative recombination becomes improbable as the number of stack increases, we found that the radiative recombination probability for electrons photoexcited within the QW increased at a large number of QW stack. Additional processes of escaping and recapturing of carriers at neighboring QW were discussed. As a result, the combination of the three non-destructive methodologies provided us new insights for optimizing the MQW components to further improve the cell performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bright reddish-orange emission and good piezoelectric properties of Sm{sub 2}O{sub 3}-modified (K{sub 0.5}Na{sub 0.5})NbO{sub 3}-based lead-free piezoelectric ceramics

Reddish orange-emitting 0.948(K{sub 0.5}Na{sub 0.5})NbO{sub 3}-0.052LiSbO{sub 3}-xmol%Sm{sub 2}O{sub 3} (KNN-5.2LS-xSm{sub 2}O{sub 3}) lead-free piezoelectric ceramics with good piezoelectric properties were fabricated in this study, and the photoluminescence and electrical properties of the ceramics were systematically studied. Results showed that Sm{sub 2}O{sub 3} substitution into KNN-5.2LS induces a phase transition from the coexistence of orthorhombic and tetragonal phases to a pseudocubic phase and shifts the polymorphic phase transition (PPT) to below room temperature. The temperature stability and fatigue resistance of the modified ceramics were significantly improved by Sm{sub 2}O{sub 3} substitution. The KNN-5.2LS ceramic with 0.4 mol. % Sm{sub 2}O{sub 3} exhibited temperature-independent properties (25–150 °C), fatigue-free behavior (up to 10{sup 6} cycles), and good piezoelectric properties (d{sub 33}{sup * }= 230 pm/V, d{sub 33} = 176 pC/N, k{sub p} = 35%). Studies on the photoluminescence properties of the samples showed strong reddish-orange emission upon blue light excitation; these emission intensities were strongly dependent on the doping concentration and sintering temperature. The 0.4 mol. % Sm{sub 2}O{sub 3}-modified sample exhibited temperature responses over a wide temperature range of 10–443 K. The maximum sensing sensitivity of the sample was 7.5 × 10{sup −4} K at 293 K, at which point PPT occurred. A relatively long decay lifetime τ of 1.27–1.40 ms and a large quantum yield η of 0.17–0.19 were obtained from the Sm-modified samples. These results suggest that the KNN-5.2LS-xSm{sub 2}O{sub 3} system presents multifunctional properties and significant technological potential in novel multifunctional devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB

We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC experiment at SNOLAB. We utilize the exquisite spatial resolution of CCDs to discriminate between α and β decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated β decays, we measure a bulk radioactive contamination of 32 Si in the CCDs of 140 ± 30 μBq/kg, and place an upper limit on bulk 210 Pb of < 160 μBq/kg. Using similar analyses of spatially-correlated α and β decays, we set upper limits of < 11 μBq/kg (0.9 ppt) on 238 U and < 7.3 μBq/kg (1.8 ppt) on 232 Th in the bulk silicon. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from 32 Si, has significant implications for the next generation of silicon-based dark matter experiments, where β's from 32 Si decay will likely be a dominant background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extremal extensions of entanglement witnesses: Finding new bound entangled states

In this paper, we discuss extremal extensions of entanglement witnesses based on Choi's map. The constructions are based on a generalization of the Choi map, from which we construct entanglement witnesses. These extremal extensions are powerful in terms of their capacity to detect entanglement of positive under partial transpose (PPT) entangled states and lead to unearthing of entanglement of new PPT states. We also use the Cholesky-like decomposition to construct entangled states which are revealed by these extremal entanglement witnesses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Finite-element simulation of the liquid-liquid transition to metallic hydrogen

Hydrogen at high temperature and pressure undergoes a phase transition from a liquid molecular phase to a conductive atomic state, or liquid metallic hydrogen, sometimes referred to as the plasma phase transition (PPT). The PPT phase line was observed in a recent experiment studying laser-pulse heated hydrogen in a diamond anvil cell in the pressure range ~100–170 GPa for temperatures up to ~2000 K. Here, the experimental signatures of the transition are (i) a negative pressure-temperature slope, (ii) a plateau in the heating curve, assumed to be related to the latent heat of transformation, and (iii) an abrupt increase in the reflectance of the sample. We present a finite-element simulation that accurately takes into account the position and time dependence of the heat deposited by the laser pulse. We calculate the heating curves and the sample reflectance and transmittance. This simulation confirms that the observed plateaus are related to the phase transition; however, we find that large values of latent heat are needed and may indicate that dynamics at the transition are more complex than considered in current models. Finally, experiments are proposed that can distinguish between a change in optical properties due to a transition to a metallic state or due to closure of the band gap in molecular hydrogen.

08 HYDROGEN↗

Wavelength and Intensity Dependence of Short Pulse Laser Xenon Double Ionization between 500 and 2300 nm

The wavelength and intensity dependence of xenon ionization with 50 fs laser pulses has been studied using time-of-flight mass spectrometry. We compare the ion yield distribution of singly and doubly charged xenon with the Perelomov-Popov-Terent'ev (PPT) theory, Perelomov, Popov, and Terent'ev, Zh. Eksp. Teor. Fiz. 50, 1393 (1966) [Sov. Phys. JETP 23, 924 (1966)], in the regime between 500 and 2300 nm. The intensity dependence for each wavelength is measured in a range between 1x10{sup 13} and 1x10{sup 15} W/cm{sup 2}. The Xe{sup +}-ion signal is in good agreement with the PPT theory at all used wavelengths. In addition we demonstrate that ionic 5s5p{sup 6} {sup 2}S state is excited by an electron impact excitation process and contributes to the nonsequential double ionization process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opposing reactions in coenzyme A metabolism sensitize Mycobacterium tuberculosis to enzyme inhibition

Mycobacterium tuberculosis (Mtb) is the leading infectious cause of death in humans. Synthesis of lipids critical for Mtb’s cell wall and virulence depends on phosphopantetheinyl transferase (PptT), an enzyme that transfers 4'-phosphopantetheine (Ppt) from coenzyme A (CoA) to diverse acyl carrier proteins. We identified a compound that kills Mtb by binding and partially inhibiting PptT. Killing of Mtb by the compound is potentiated by another enzyme encoded in the same operon, Ppt hydrolase (PptH), that undoes the PptT reaction. Thus, loss-of-function mutants of PptH displayed antimicrobial resistance. Our PptT-inhibitor cocrystal structure may aid further development of antimycobacterial agents against this long-sought target. The opposing reactions of PptT and PptH uncover a regulatory pathway in CoA physiology.

60 APPLIED LIFE SCIENCES↗

Performance Prediction Toolkit

The Performance Prediction Toolkit (PPT), is a scalable co-design tool that contains the hardware and middle-ware models, which accept proxy applications as input in runtime prediction. PPT relies on Simian, a parallel discrete event simulation engine in Python or Lua, that uses the process concept, where each computing unit (host, node, core) is a Simian entity. Processes perform their task through message exchanges to remain active, sleep, wake-up, begin and end.

Chennupati, Gopinath↗

TA-60 Warehouse and Salvage SWPPP Rev 2 Jan 2017-Final

The Stormwater Pollution Prevention Team (PPT) for the TA-60-0002 Salvage and Warehouse Area consists of operations and management personnel from the facility, Multi-Sector General Permitting (MSGP) stormwater personnel from Environmental Compliance Programs (EPC-CP) organization, and Deployed Environmental Professionals. The EPC-CP representative is responsible for Laboratory compliance under the National Pollutant Discharge Elimination System (NPDES) permit regulations. The team members are selected on the basis of their familiarity with the activities at the facility and the potential impacts of those activities on stormwater runoff. The Warehouse and Salvage Yard are a single shift operation; therefore, a member of the PPT is always present during operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stormwater Pollution Prevention Plan for the TA-03-22 Power and Steam Plant, Los Alamos National Laboratory, Revision 3 Final, January 2018

The TA-03-22 Power and Steam Plant (PSP) is part of LANL’s Utilities and Institutional (UI) Facilities Operations Directorate (FOD) with day-to-day management provided by UI facility and operations personnel; which has established a Stormwater Pollution Prevention Team (PPT) whose members are responsible for assisting the facility manager in developing and revising the facility’s SWPPP as well as maintaining control measures and taking corrective actions when required. All PPT members will have access to either a hard copy or an electronic version of this SWPPP.

54 ENVIRONMENTAL SCIENCES↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗