Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Investigation of the Muffling Problem for Airplane Engines

The experimentation presented in this report falls in two divisions: first, the determination of the relation between back pressure in the exhaust line and consequent power loss, for various combinations of speed and throttle positions of the engine; second, the construction and trial of muffler designs covering both type and size. Report deals with experiments in the development of a muffler designed on the principle which will give the maximum muffling effect with a minimum loss of power. The main body of the work has been done on a Curtiss OX eight-cylinder airplane engine, 4 by 5 inches, rated 70 horsepower at 1,200 revolutions per minute. For estimation of the muffling ability and suppression of "bark" of individual exhausts, the "Ingeco" stationary, single cylinder, 5 1/2 by 10 inch, throttling governed gasoline engine, and occasionally other engines were used.

Upton, G B↗

Programmable high voltage power supply with regulation confined to the high voltage section

A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

Castell, Karen D.↗

A MILP-Based Distribution Optimal Power Flow Model for Microgrid Operation

This paper proposes a distribution optimal power flow (D-OPF) model for the operation of microgrids. The proposed model minimizes not only the operating cost, including fuel cost, purchasing cost and demand charge, but also several performance indices, including voltage deviation, network power loss and power factor. It co-optimizes the real and reactive power form distributed generators (DGs) and batteries considering their capacity and power factor limits. The D-OPF is formulated as a mixed-integer linear programming (MILP). Numerical simulation results show the effectiveness of the proposed model.

distributed generators↗

Effects of lubrication on the performance of high speed spur gears

An experimental analysis was conducted to determine power loss and gear noise of high speed spur gears with long addendum under various conditions of load, speed, and oil jet pressure for into mesh lubrication. Power losses were calculated from temperature measurements of lubricating oil, gears, gear box, and oil flow rate. Furthermore, power loss was divided into windage loss, friction loss and churning loss. The results show that windage loss and churning loss were the main components of gear power loss of high gear speed. In addition, lubricating conditions had some influences on gear noise especially under low oil temperature or high viscosity.

Mizutani, Hachiro↗

Effects of lubrication on the performance of high speed spur gears

An experimental analysis was conducted to determine power loss and gear noise of high speed spur gears with long addendum under various conditions of load, speed, and oil jet pressure for into mesh lubrication. Power losses were calculated from temperature measurements of lubricating oil, gears, gear box, and oil flow rate. Furthermore, power loss was divided into windage loss, friction loss and churning loss. The results show that windage loss and churning loss were the main components of gear power loss of high gear speed. In addition, lubricating conditions had some influences on gear noise especially under low oil temperature or high viscosity.

Mizutani, H.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

A New Linearization Method of Unbalanced Electrical Distribution Networks

Abstract--- With increasing penetration of distributed generation in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. As DN control and operation strategies are mostly based on the linearized sensitivity coefficients between controlled variables (e.g., node voltages, line currents, power loss) and control variables (e.g., power injections, transformer tap positions), efficient and precise calculation of these sensitivity coefficients, i.e. linearization of DN, is of fundamental importance. In this paper, the derivation of the node voltages and power loss as functions of the nodal power injections and transformers' tap-changers positions is presented, and then solved by a Gauss-Seidel method. Compared to other approaches presented in the literature, the proposed method takes into account different load characteristics (e.g., constant PQ, constant impedance, constant current and any combination of above) of a generic multi-phase unbalanced DN and improves the accuracy of linearization. Numerical simulations on both IEEE 13 and 34 nodes test feeders show the efficiency and accuracy of the proposed method.

linearization↗

Energy relaxation of hot electrons in Si-doped GaN

Energy relaxation of the hot electrons in Si-doped bulk GaN is studied theoretically, taking into account non-equilibrium polar optical phonons, electron degeneracy, and screening from the mobile electrons. The electron power dissipation and energy relaxation time are calculated as functions of the electron temperature T{sub e}, the hot-phonon effect (HPE) is examined by varying the optical phonon lifetime values, and the results are compared with previous calculations for typical GaN-based heterostructures. Particular attention is paid to the distinct temperature T{sub e} dependences of the power loss and the energy relaxation time τ{sub E} at the low and high electron temperatures. At low electron temperatures (T{sub e}<500 K), the exponential rise of phonon generation number, fast weakened screening and HPE result in a rapid increase of power loss and sharp drop of relaxation time with T{sub e}. At high electron temperatures (T{sub e}>1500 K), the power loss increases slowly with T{sub e} due to the decrease in phonon generation rate, and the temperature-dependence of the energy relaxation time depends on the polar optical phonon lifetime—saturation in energy relaxation occurs when the phonon lifetime increases or varies little with T{sub e}. Our calculated temperature dependences of the energy relaxation time are in good agreement with experimental findings [Liberis et al., Appl. Phys. Lett. 89, 202117 (2006); Matulionis et al., Phys. Status Solidi C 2, 2585 (2005)]. With no HPE, the electron energy relaxation is much faster in bulk GaN (τ{sub E}∼ several tens femtoseconds) than in the GaN-based heterostructures. However, stronger hot-phonon re-absorption occurs in bulk GaN due to rapid polar-optical phonon emission compared to phonon decay. Therefore, including HPE yields very close power loss and energy relaxation times in bulk and heterostructures with similar densities of electrons (τ{sub E}∼ several tenths of a picosecond). Transparent expressions for energy relaxation are obtained in the Boltzmann approximation, which are very useful for resolving the temperature dependences of the energy relaxation in the low- and high-T{sub e} regions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Swept Volume Approach for the Characterization of Pumping Loss of Shrouded Meshed Cylindrical Gears

High speed rotorcraft transmissions are subject to load-independent power losses consisting of drag and pumping loss. Tightly conforming shrouds enclosing the transmission gears are often incorporated to reduce the drag component of the total load-independent losses. However, tightly conforming axial shrouding can result in an increase in the pumping loss component. Quantifying the pumping loss of shrouded gear transmissions has been the subject of many studies. This study presents a new approach for estimating pumping loss based on the concept of swept volume borrowed from the positive displacement pump and compressor industry. In this study, pumping loss of shrouded gear transmissions is considered to be related to the swept volume of the gear sets and the downstream flow resistance created by the shroud clearances. The drag loss and pumping loss of a spur gear pair have been determined through testing using the NASA Glenn Research Center Gear Windage Test Facility. The results from this testing have been compared to theoretical results using the formulations presented in this study. Good correlation exist between the test pumping power loss and the predicted pumping power loss for tightly conforming axial shroud configurations.

Hurrell, Michael J.↗

Loss Control and Monitoring Systems for NSLS-Ii

The tunnel shielding design for the NSLS-II will provide adequate protection for beam losses up to 13nC/min or 100% of the maximum top-off injection beam current to be lost in the two periods of the ring around the injection point, while the remainder of the ring is shielded for lower losses of 1.1nC/min or ≤10% of the maximum top-off injected beam current. Additional local shielding of potential loss points in the injection region (e.g. injection septum) will be used to increase the level of loss allowed at these location during 1 Hz injection (i.e. nonTop-off injection). This shielding design will require a system to insure that beam losses don’t exceed these levels for a period of time that could potentially cause levels of radiation outside the shield walls to exceed administrative levels. This Loss Control and Monitoring (LCM) system will provide a level of loss control, loss location measurements and provide alarm indication of the level of beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators and scrapers that will provide limits to the beam miss-steering and control the loss points of the charge, and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications or administrative levels. This will require some new ideas in beam loss detection capability and collimation. The system is not intended to trip interlocks (dumping beam or terminating injection) but only to alarm that higher than normal beam power losses are observed and report where it is occurring. If the alarms conditions are not corrected within a time limit, top-off injection could be slowed down, thereby reducing the beam loss and the radiation it may be producing.

36 MATERIALS SCIENCE↗

Theory of ac loss in power transmission cables with second generation high temperature superconductor wires

While a considerable amount of work has been done in an effort to understand ac losses in power transmission cables made of first generation high temperature superconductor (HTS) wires, use of second generation (2G) HTS wires brings in some new considerations. The high critical current density of the HTS layer in 2G wires reduces the surface superconductor hysteretic losses, for which a new formula is derived. Instead, gap and polygonal losses, flux transfer losses in imbalanced two-layer cables and ferromagnetic losses for wires with NiW substrates constitute the principal contributions. A formula for the flux transfer losses is also derived with a paramagnetic approximation for the substrate. Current imbalance and losses associated with the magnetic substrate can be minimized by orienting the substrates of the inner winding inward and the outer winding outward.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the impact of design factors on solar module thermomechanical durability using interpretable machine learning techniques

Solar modules in utility-scale systems are expected to maintain decades of lifetime to rival conventional energy sources. However, cyclic thermomechanical loading often degrades their long-term performance, highlighting the importance of effective design to mitigate thermal expansion mismatches between module materials. Given the complex composition of solar modules, isolating the impact of individual components on overall durability remains a challenging task. In this work, we analyze a comprehensive data set that comprises bill-of-materials (BOM) and thermal cycling power loss from 251 distinct module designs to identify the predominant design factors and their impacts on the thermomechanical durability of modules. The methodology of our analysis combines machine learning modeling (random forest) and Shapley additive explanation (SHAP) to correlate design factors with power loss and interpret the model’s decision-making. The interpretation reveals that silicon type (monocrystalline or polycrystalline), encapsulant thickness, busbar numbers, and wafer thickness predominantly influence the degradation. With lower power loss of around 0.6% on average in the SHAP analysis, monocrystalline cells present better durability than polycrystalline cells. This finding is further substantiated by statistical testing on our raw data set. The SHAP analysis also demonstrates that while thicker encapsulants lead to reduced power loss, further increasing their thickness over around 0.6 to 0.7 mm does not yield additional benefits, particularly for the front side one. In addition, other important BOM features such as the number of busbars are analyzed. This study provides a blueprint for utilizing explainable machine learning techniques in a complex material system and can potentially guide future research on optimizing the design of solar modules.

14 SOLAR ENERGY↗

Chapter 3: Photovoltaic Module Stability and Reliability

Profits realized from investment in photovoltaic will benefit from decades of reliable operation. Service life prediction through accelerated tests is only possible if indoor tests duplicate power loss and failure modes observed in fielded systems. Therefore, detailing and quantifying power loss and failure modes is imperative. In the first section, we examine recent trends in degradation rates, the gradual power loss observed for different technologies, climates and other significant factors. In the second section, we provide a summary of the most commonly observed failure modes in fielded systems.

14 SOLAR ENERGY↗

Effect of the scrape-off layer in AORSA full wave simulations of fast wave minority, mid/high harmonic, and helicon heating regimes

Several experiments on different machines and in different fast wave (FW) heating regimes, such as hydrogen minority heating and high harmonic fast waves, have found strong interactions between radio-frequency (RF) waves and the scrape-off layer (SOL) region. This paper examines the propagation and the power loss in the SOL by using the full wave code AORSA, in which the edge plasma beyond the last closed flux surface (LCFS) is included in the solution domain and a collisional damping parameter is used as a proxy to represent the real, and most likely nonlinear, damping processes. 3D AORSA results for the National Spherical Torus eXperiment (NSTX), where a full antenna spectrum is reconstructed, are shown, confirming the same behavior found for a single toroidal mode results in Bertelli et al, Nucl. Fusion, 54 083004, 2014, namely, a strong transition to higher SOL power losses (driven by the RF field) when the FW cut-off is moved away from in front of the antenna by increasing the edge density. Additionally, full wave simulations have been extended to “conventional” tokamaks with higher aspect ratios, such as the DIII-D, Alcator C-Mod, and EAST devices. DIII-D results show similar behavior found in NSTX and NSTX-U, consistent with previous DIII-D experimental observations. In contrast, a different behavior has been found for Alcator C-Mod and EAST, which operate in the minority heating regime unlike NSTX/NSTX-U and DIII-D, which operate in the mid/high harmonic regime. A substantial discussion of some of the main aspects, such as (i) the pitch angle of the magnetic field; (ii) minority heating vs. mid/high harmonic regimes is presented showing the different behavior of the RF field in the SOL region for NSTX-U scenarios with different plasma current. Finally, the preliminary results of the impact of the SOL region on the evaluation of the helicon current drive efficiency in DIII-D is presented for the first time and briefly compared with the different regimes mentioned above.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LED lamp power management system and method

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

42 ENGINEERING↗

Hold-up power supply for flash memory

A hold-up power supply for flash memory systems is provided. The hold-up power supply provides the flash memory with the power needed to temporarily operate when a power loss exists. This allows the flash memory system to complete any erasures and writes, and thus allows it to shut down gracefully. The hold-up power supply detects when a power loss on a power supply bus is occurring and supplies the power needed for the flash memory system to temporally operate. The hold-up power supply stores power in at least one capacitor. During normal operation, power from a high voltage supply bus is used to charge the storage capacitors. When a power supply loss is detected, the power supply bus is disconnected from the flash memory system. A hold-up controller controls the power flow from the storage capacitors to the flash memory system. The hold-up controller uses feedback to assure that the proper voltage is provided from the storage capacitors to the flash memory system. This power supplied by the storage capacitors allows the flash memory system to complete any erasures and writes, and thus allows the flash memory system to shut down gracefully.

Ott, William E.↗