Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER CAPTURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Sensor placement algorithm development to maximize the efficiency of acid gas removal unit for integrated gasifiction combined sycle (IGCC) power plant with CO2 capture

Future integrated gasification combined cycle (IGCC) power plants with CO{sub 2} capture will face stricter operational and environmental constraints. Accurate values of relevant states/outputs/disturbances are needed to satisfy these constraints and to maximize the operational efficiency. Unfortunately, a number of these process variables cannot be measured while a number of them can be measured, but have low precision, reliability, or signal-to-noise ratio. In this work, a sensor placement (SP) algorithm is developed for optimal selection of sensor location, number, and type that can maximize the plant efficiency and result in a desired precision of the relevant measured/unmeasured states. In this work, an SP algorithm is developed for an selective, dual-stage Selexol-based acid gas removal (AGR) unit for an IGCC plant with pre-combustion CO{sub 2} capture. A comprehensive nonlinear dynamic model of the AGR unit is developed in Aspen Plus Dynamics® (APD) and used to generate a linear state-space model that is used in the SP algorithm. The SP algorithm is developed with the assumption that an optimal Kalman filter will be implemented in the plant for state and disturbance estimation. The algorithm is developed assuming steady-state Kalman filtering and steady-state operation of the plant. The control system is considered to operate based on the estimated states and thereby, captures the effects of the SP algorithm on the overall plant efficiency. The optimization problem is solved by Genetic Algorithm (GA) considering both linear and nonlinear equality and inequality constraints. Due to the very large number of candidate sets available for sensor placement and because of the long time that it takes to solve the constrained optimization problem that includes more than 1000 states, solution of this problem is computationally expensive. For reducing the computation time, parallel computing is performed using the Distributed Computing Server (DCS®) and the Parallel Computing® toolbox from Mathworks®. In this presentation, we will share our experience in setting up parallel computing using GA in the MATLAB® environment and present the overall approach for achieving higher computational efficiency in this framework.

97 MATHEMATICS AND COMPUTING↗

A net-zero emissions strategy for China’s power sector using carbon-capture utilization and storage

Decarbonized power systems are critical to mitigate climate change, yet methods to achieve a reliable and resilient near-zero power system are still under exploration. This study develops an hourly power system simulation model considering high-resolution geological constraints for carbon-capture-utilization-and-storage to explore the optimal solution for a reliable and resilient near-zero power system. This is applied to 31 provinces in China by simulating 10,450 scenarios combining different electricity storage durations and interprovincial transmission capacities, with various shares of abated fossil power with carbon-capture-utilization-and-storage. Here, we show that allowing up to 20% abated fossil fuel power generation in the power system could reduce the national total power shortage rate by up to 9.0 percentages in 2050 compared with a zero fossil fuel system. A lowest-cost scenario with 16% abated fossil fuel power generation in the system even causes 2.5% lower investment costs in the network (or $16.8 billion), and also increases system resilience by reducing power shortage during extreme climatic events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploratory design study on reactor configurations for carbon dioxide capture from conventional power plants employing regenerable solid sorbents

Preliminary commercial designs were carried out for a fluidized bed as a CO{sub 2} adsorber and a moving bed as a CO{sub 2} regenerator. Reverse engineering methodology was employed on the basis of a commercial 500 MW supercritical PC power plant whereby the boundaries required for a particular reactor design and configuration could be set. Employing the proposed moving bed for regenerator is, however, not promising because of poor heat transfer, evolution of CO{sub 2} during regeneration, and high pressure drop when small particles are used. If regeneration kinetics is as slow as reported in tens of minutes, the bed height can be quite high and the reactor can be quite costly. In its place, a so-called assisted self-fluidization bed with embedded heat transfer surface was proposed. Theoretically, there is no reason why the fluidized bed cannot be successfully designed and operated both as an adsorber and a regenerator under proper adsorption and regeneration kinetics. Recent publications, where fluidized beds, circulating fluidized beds, or a combination of them were employed both as an adsorber and a regenerator, were cited. Staging may not be necessary employing the fluidized bed technology because of the capability to control reaction temperature at the optimum operating temperature through embedded heat transfer surface in the fluidized beds. Even if the staging is necessary, the implementation of staging in fluidized beds at ambient pressure and moderate temperature is relatively easy and with minimum cost penalty. Example designs are presented.

01 COAL, LIGNITE, AND PEAT↗

Comparative analysis of the effects of electron and hole capture on the power characteristics of a semiconductor quantum-well laser

The operating characteristics of a semiconductor quantum-well laser calculated using three models are compared. These models are (i) a model not taking into account differences between the electron and hole parameters and using the electron parameters for both types of charge carriers; (ii) a model, which does not take into account differences between the electron and hole parameters and uses the hole parameters for both types of charge carriers; and (iii) a model taking into account the asymmetry between the electron and hole parameters. It is shown that, at the same velocity of electron and hole capture into an unoccupied quantum well, the laser characteristics, obtained using the three models, differ considerably. These differences are due to a difference between the filling of the electron and hole subbands in a quantum well. The electron subband is more occupied than the hole subband. As a result, at the same velocities of electron and hole capture into an empty quantum well, the effective electron-capture velocity is lower than the effective hole-capture velocity. Specifically, it is shown that for the laser structure studied the hole-capture velocity of 5 × 10{sup 5} cm/s into an empty quantum well and the corresponding electron-capture velocity of 3 × 10{sup 6} cm/s into an empty quantum well describe the rapid capture of these carriers, at which the light–current characteristic of the laser remains virtually linear up to high pump-current densities. However, an electron-capture velocity of 5 × 10{sup 5} cm/s and a corresponding hole-capture velocity of 8.4 × 10{sup 4} cm/s describe the slow capture of these carriers, causing significant sublinearity in the light–current characteristic.

36 MATERIALS SCIENCE↗

Capturing Infrastructure Interdependencies for Power Outages Prediction During Extreme Events

As extreme weather events such as hurricanes, severe thunderstorms, and floods grow in frequency and intensity, the disruption of power grid systems poses significant challenges, including widespread electrical outages, economic losses, and threats to public safety. This paper presents a forward-looking approach that leverages geographical graph-based machine learning models to predict county-level maximum power outages during such events. By capturing the intricate interdependencies within power system networks, our approach aims to provide precise and actionable predictions that can optimize emergency response efforts and enhance grid resilience. Through the integration of real-world data, including hurricane advisories and power outage records, we have trained and benchmarked multiple machine learning models, demonstrating the feasibility and potential of this method. While our initial results are promising, this paper also charts a course for advancing these models, addressing the remaining challenges, and ultimately transforming how we anticipate and respond to the impacts of extreme weather on power systems.

Lee, Sangkeun (Matt) [ORNL] (ORCID:000000021317511↗

Examination of the effect of system pressure ratio and heat recuperation on the efficiency of a coal based gas turbine fuel cell hybrid power generation system with CO2 capture

This paper examines two coal-based hybrid configurations that employ separated anode and cathode streams for the capture and compression of CO2. One configuration uses a standard Brayton cycle, and the other adds heat recuperation ahead of the fuel cell. Results show that peak efficiencies near 55% are possible, regardless of cycle configuration, including the cost in terms of energy production of CO2 capture and compression. The power that is required to capture and compress the CO2 is shown to be approximately 15% of the total plant power.

01 COAL, LIGNITE, AND PEAT↗

Steady-state simulation and optimization of an integrated gasification combined cycle power plant with CO2 capture

Integrated gasification combined cycle (IGCC) plants are a promising technology option for power generation with carbon dioxide (CO2) capture in view of their efficiency and environmental advantages over conventional coal utilization technologies. This paper presents a three-phase, top-down, optimization-based approach for designing an IGCC plant with precombustion CO2 capture in a process simulator environment. In the first design phase, important global design decisions are made on the basis of plant-wide optimization studies with the aim of increasing IGCC thermal efficiency and thereby making better use of coal resources and reducing CO2 emissions. For the design of an IGCC plant with 90% CO2 capture, the optimal combination of the extent of carbon monoxide (CO) conversion in the water-gas shift (WGS) reactors and the extent of CO2 capture in the SELEXOL process, using dimethylether of polyethylene glycol as the solvent, is determined in the first phase. In the second design phase, the impact of local design decisions is explored considering the optimum values of the decision variables from the first phase as additional constraints. Two decisions are made focusing on the SELEXOL and Claus unit. In the third design phase, the operating conditions are optimized considering the optimum values of the decision variables from the first and second phases as additional constraints. The operational flexibility of the plant must be taken into account before taking final design decisions. Two studies on the operational flexibility of the WGS reactors and one study focusing on the operational flexibility of the sour water stripper (SWS) are presented. At the end of the first iteration, after executing all the phases once, the net plant efficiency (HHV basis) increases to 34.1% compared to 32.5% in a previously published study (DOE/NETL-2007/1281; National Energy Technology Laboratory, 2007). The study shows that the three-phase, top-down design approach presented is very useful and effective in a process simulator environment for improving efficiency and flexibility of IGCC power plants with CO2 capture. In addition, the study identifies a number of key design variables that has strong impact on the efficiency of an IGCC plant with CO2 capture.

01 COAL, LIGNITE, AND PEAT↗

Flexible operation of coal fired power plants with postcombustion capture of carbon dioxide

Carbon capture and storage is one family of technologies that could be used to significantly reduce global carbon dioxide (CO{sub 2}) emissions. This paper reviews the likely flexibility of power plants with postcombustion capture, with a focus on an improved characterization of the dynamic performance of power plants with CO{sub 2} capture. The literature has focused on design and optimization for steady state operation of power plants with capture, often at a single design point. When dynamic behavior is considered, it is possible that designs should be altered for best overall plant performance. Economic trade-offs between improving transport and storage scheme flexibility and constraining power plant operations should also be carefully analyzed, particularly if the captured CO{sub 2} is to be used in another process such as enhanced oil recovery. Another important aspect of real plant operation will be adhering to legislative requirements. Further work is required to identify mechanisms that allow flexible operation without undermining any targets set for storing CO{sub 2} and/or restricting global CO{sub 2} emissions.

01 COAL, LIGNITE, AND PEAT↗

Optimal control system design for IGCC power plants with CO2 capture

Designing an optimal control system for an integrated gasification combined cycle (IGCC) power plant with CO2 capture addresses the challenge of efficiently operating and controlling a coal-fed IGCC plant with the desired extent of CO2 capture in the face of disturbances without violating operational and environmental constraints. The control system design needs to optimize a desired scalar objective function while satisfying all the operational and environmental constraints in the presence of measured and unmeasured disturbances. Various objective functions can be considered for the control system design such as maximization of profit, maximization of the power produced, or minimization of the auxiliary power. The design of such a control system makes the plant suitable to play an active role in the smart grid era as the plant will have the required agility. In addition, other penalty function(s) such as emission penalties for CO2 or other criteria pollutants can be considered in the framework as well as losses associated with any hydrogen or carbon monoxide loses. The proposed control system design is performed in two stages. In the first stage, a top-down analysis is performed to generate a list of controlled, manipulated, and disturbance variables considering a scalar operational objective and other process constraints. In the second stage, a bottom-up approach for simultaneous design of the control structure and the controllers is used. In this paper, the first stage of the two-stage approach is applied to the IGCC’s acid gas removal (AGR) process which removes both H2S and CO2 from the shifted synthesis gas. While these results are still preliminary, they demonstrate the application of the proposed approach for a commercial-scale plant and show some interesting results related to controlled variable selection. Such an approach can be followed not only to design control systems for new power plants, but also to retrofit control systems for existing plants with suitable modifications.

97 MATHEMATICS AND COMPUTING↗

Direct Air Capture (DAC) With Nuclear Power Sources

The presentation summarizes a recently published report, along with ANL and INL, on utilizing waste heat and power from nuclear power plants (NPP) for direct air capture (DAC) applications. Two DAC technologies are considered – solid sorbent (S-DAC) and liquid solvent (L-DAC). S-DAC uses both heat and power from NPPs, while L-DAC uses only power. The results show that using NPPs for DAC applications results in an economic benefit compared to using fossil fired power plants

Mantripragada, Hari↗

Performance Baseline for Oxy-Coal MHD Power Plant with Carbon Capture

This presentation discusses the development of baseline Direct Power Extraction (DPE) plant designs incorporating oxy-coal combustion, a magnetohydrodynamic (MHD) topping cycle, a steam bottoming cycle, and a carbon dioxide purification unit for carbon capture and storage (CCS). Two MHD configurations have been developed; one representing the current state-of-the-art in MHD channel design, and a more advanced design capable of higher power density. The MHD cycle incorporates potassium seeding for plasma generation and a potassium formate seed recovery process that also removes sulfur from the combustion products. The air separation unit for oxygen production, MHD system, and seed recovery systems are all thermally integrated with a Rankine bottoming cycle operating at advanced ultra-supercritical (AUSC) steam conditions. The modeled performance of the two DPE plant systems are compared to IGCC and oxy-coal AUSC reference plants with CCS.

Weiland, Nathan↗

Optimal Synthesis of a Pulverized Coal Power Plant with Carbon Capture

Coal constitutes an important source of fuel for the production of power in the United States. For instance, in January 2009, pulverized coal (PC) power plants alone contributed to over 45 percent of the Nation's total electric power production. However, PC power plants also contribute to increased emissions of greenhouse gases principally carbon-dioxide (CO2). Recently, various carbon capture strategies have been under active investigation so as to make these plants compete with the more environmental friendly renewable energy sources. One such technology that has received considerable success is the capture of CO2 by an amine-based solvent extraction process. However, an aqueous absorption/stripping technology when used in a PC power plant can reduce the net power output of the plant by as much as 20-40%. The energy penalty comes from heating up the solvent in the regenerator, balancing the enthalpy of reaction, and water stripping. This energy penalty poses considerable limitations on commercial viability of the solvent extraction process and, as a result, various energy-saving modifications have been proposed in the literature ranging from the use of hybrid solvents to novel stripper configurations. In this paper, we show that the energy penalty can be further reduced by heat integration of various PC plant components with the carbon capture system. In addition to the release of greenhouse gases to the environment, PC plants also consume a large amount of freshwater. It is estimated that subcritical and supercritical PC plants have water losses of 714 gal/MWh and 639 gal/MWh, respectively. Water loss is based on an overall balance of the plant source and exit streams. This includes coal moisture, air humidity, process makeup, cooling tower makeup (equivalent to evaporation plus blowdown), process losses (including losses through reactions, solids entrainment, and process makeup/blowdown) and flue gas losses. The primary source of water used in PC power plants is the closed-loop steam-based (Rankine) power cycles. These plants need to condense large quantities of low-pressure steam back to water so that it can be reused to produce high pressure steam. However, this requires the removal of large quantities of heat from the low pressure steam in the condensation process. This is usually done by transferring the heat to cooling water, which in turn transfers this heat to the environment by evaporation to the atmosphere. Also, the inclusion of a carbon capture process can increase the raw water usage by as much as 95 percent. In this work, we use heat exchanger network synthesis followed by an optimization approach to process synthesis for developing strategies for reducing water use in a supercritical PC power plant with a carbon capture and compression system. Uncertainties associated with dry bulb temperature, relative humidity, and demand will also be considered in this analysis.

01 COAL, LIGNITE, AND PEAT↗