Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMU measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Real-time Event Detection Using Rank Signatures of Real-world PMU Data

Timely detection of power system events is a crucial task, which can facilitate the implementation of remedial actions to improve reliability, resiliency, and security of the system. Meanwhile, the widespread deployment of phasor measurement units (PMUs) makes it possible to develop data-driven event detection techniques. However, relying purely on data without incorporating domain knowledge for the event detection task in power systems poses substantial security and stability risks due to issues associated with data misinterpretation and model accuracy. In this regard, we propose a real-time event detection method using real-world PMU data by incorporating domain knowledge to adequately capture the event signatures. Specifically, we track the change in rank signatures of PMU data to accurately localize the events. To optimize the detection process, we incorporate an offline Bayesian optimization algorithm to tune the parameters by efficiently searching for the best values. The experiments using the real-world PMU dataset from a U.S. interconnection show that the proposed event detection approach can efficiently detect the events from PMU data streams with high accuracy.

Ghasemkhani, Amir↗

PMU-data-driven Event Classification in Power Transmission Grids

This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.

Niazazari, Iman↗

Characterizing the Oscillatory Properties of Bulk Electric Systems

This paper presents a process for characterizing the oscillatory dynamics of a large bulk power system. As a demonstration, the process is applied to the Western Interconnection of North America. Several complementary analysis approaches, both new and existing, are employed to provide a comprehensive understanding of the oscillatory properties of the system. Established modal analysis techniques based on ringdown and mode-meter algorithms are utilized. In addition, we derive and apply methods based on spectral correlation analysis to identify modal frequencies, distinguish between modes that are closely spaced in frequency, and determine locations at which the modes are observable. Critical interarea modes are identified and characterized using actual-system synchrophasor measurements taken over several years of operation in concert with industry-standard simulation models. This includes 145 hours of PMU data and two planning base cases.

42 ENGINEERING↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

This paper is the basis for a presentation help at the 2026 Georgia Tech Fault & Disturbance Analysis Conference, which can be found at OSTI # 3168287 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danovo Energy Solutions]↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

Danovo Energy Solution's presented its paper named: Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events at the 2026 Georgia Tech Fault & Disturbance Analysis Conference. The full paper can be found at OSTI ID# 3169150 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danova Energy Solutions]↗

Estimation of Electromechanical Modes of Oscillation in the Eastern Interconnection from Ambient PMU Data

A power system's inter-area electromechanical modes of oscillation determine if the system is small-signal stable. Mode meters are tools that estimate the modes based on ambient synchrophasor measurements, allowing continuous monitoring of the system's stability margin. This paper reports on the application of mode meter algorithms to 21 months of synchrophasor measurements from the United States Eastern Interconnection (EI). Estimates for three modes were updated every minute, providing a much more comprehensive set of results than previous studies based on disturbance recordings. The detailed signal designs and mode meter configurations provided in this paper can be used to accelerate mode meter deployments in the EI. Analysis of the mode estimates reveal for the first time how seasonal load changes and system reconfiguration impact the EI system's dynamics.

Follum, James D.↗

Power System Event Identification Based on Deep Neural Network With Information Loading

Online power system event identification and classification are crucial to enhancing the reliability of transmission systems. In this study, we develop a deep neural network (DNN) based approach to identify and classify power system events by leveraging real-world measurements from hundreds of phasor measurement units (PMUs) and labels from thousands of events. Two innovative designs are embedded into the baseline model built on convolutional neural networks (CNNs) to improve the event classification accuracy. First, we propose a graph signal processing based PMU sorting algorithm to improve the learning efficiency of CNNs. Second, we deploy information loading based regularization to strike the right balance between memorization and generalization for the DNN. Numerical results based on real-world dataset from the Eastern Interconnection of the U.S power transmission grid show that the combination of PMU based sorting and the information loading based regularization techniques help the proposed DNN approach achieve highly accurate event identification and classification results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

High-Impedance Non-Linear Fault Detection via Eigenvalue Analysis with low PMU Sampling Rates

This work presents a hybrid data-driven and physics-based framework for high-impedance fault detection in power systems. An innovative method based on eigenvalue analysis is expanded and validated. Phasor Measurement Unit data is used to estimate eigenvalues corresponding to the powerlines being monitored. The projection and drift of these eigenvalues is then tracked and evaluated. Faults are detected as they drive eigenvalues outside of their normal zones. Eigenvectors are leveraged to support and validate the decisions made by the main algorithm. This technique holds several advantages over contemporary techniques in that it utilizes technology that is already deployed in the field, it offers a significant degree of generality, and so far it has displayed a very high-level of sensitivity without sacrificing accuracy. Validation takes place in the form of simulations in the IEEE 13 Node System considering a popular high-impedance non-linear fault model. Test results are encouraging indicating potential for real-life applications.

Paramo, Gian↗

Online Detection of Low-Quality Synchrophasor Data Considering Frequency Similarity

Here, this letter proposes a new approach for online detection of low-quality synchrophasor data under both normal and event conditions. The proposed approach utilizes the features of synchrophasor data in time and frequency domains to distinguish multiple regional PMU signals and detect low-quality synchrophasor data. It is more effective to detect low-quality data with apparently indistinguishable profiles. Case studies from recorded synchrophasor measurements verify the effectiveness of the proposed approach for detecting low-quality synchrophasor data in frequency, voltage magnitude and voltage angle.

42 ENGINEERING↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for controlling electrical grid resources

The present invention relates to PMU-based control systems for dampening inter-area oscillations in large-scale interconnected power systems or grids to protect against a catastrophic blackout. The control systems receive phasor measurements from two or more locations on an AC transmission line and generates a power control command to a power resource on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor Data Anomaly Detection on Grid Edge by 5G Communication and Adjacent Compute

The fifth-generation mobile communication (5G) technology offers the opportunities to enhance the grid real-time monitoring. The 5G-enabled phasor measurement units (PMUs) features flexible positioning and cost-effective long-term maintenance, without constraints of fixing wire. This paper is the first to demonstrate the applicability of 5G in PMU communication, and the experiment was carried out at Verizon non-standalone testbed at Pacific Northwest National Laboratory (PNNL) Advanced Wireless Communication lab. The performance of 5G-enabled PMU communication setup is reviewed and discussed in this paper, and the paper presents a real-time dynamic linear model (DML) based synchrophasor data anomaly detection application. Last but not least, the practicability of implementing 5G for wide-area protection strategies is explored and discussed by analyzing the experimental results.

5G, Synchrophasor data, machine learning, anomaly ↗

Using Synchrophasor Status Word as Data Quality Indicator: What to Expect in the Field?

Data quality plays a crucial role in successful applications of synchrophasor data in power system operation and control. This paper presents the results of a data quality analysis of a multi-year field-recorded synchrophasor dataset. The analysis has identified several typical data quality issues encountered in the field data. An examination of the PMU status words included with the dataset has revealed several inconsistent implementations and the lack of correlation between the PMU data quality and the status word, which impacts the usefulness of such information. Our investigation has concluded that the status word alone as found in the recorded field dataset could not be used as a reliable indicator of data quality for field-recorded data. Several recommendations are proposed to improve the usefulness of the PMU status word.

Cheng, Zheyuan↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Power System Event Detection via Bidirectional Generative Adversarial Networks

Accurate and speedy detection of power system events is critical to enhancing the reliability and resiliency of power systems. Although supervised deep learning algorithms show great promise in identifying power system events, they require a large volume of high-quality event labels for training. This paper develops a bidirectional anomaly generative adversarial network (GAN)-based algorithm to detect power system events using streaming PMU data, which does not rely on a huge amount of event labels. By introducing conditional entropy constraint in the objective function of GAN and graph signal processing-based PMU sorting technique, our proposed algorithm significantly outperforms state-of-the-art event detection algorithms in terms of accuracy. To facilitate the adoption of the proposed algorithm, a prototype online platform is also developed using Apache Hadoop, Kafka, and Spark to enable real-time event detection. Here, the accuracy and computational efficiency of the proposed algorithm are validated using a large-scale real-world PMU dataset from the Eastern Interconnection of the United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗