A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea↗

Failure Investigation & Design Optimization of a Photo-Multiplier Tube Assembly Under Thermal Loading

Analysis of GLAST ACD Photo-Multiplier Tube (PMT) assembly under thermal loading demonstrates that the glass tube experiences high stresses due to Coefficient of Thermal Expansion mismatch, as well as increased stress due to high stiffness and incompressibility of potting compound. Further investigation shows adverse loading effects due to the magnetic shield, a thin piece of steel wrapped around the PMT. This steel, Mu Metal, contained an overlap region that directly attributed to crack propagation in the outside surface of the tube. Sensitivities to different configurations were studied to reduce the stress and provide a more uniform loading throughout the PMT to ensure mission success. Studies indicate substituting a softer and more compressible potting compound and moving the Mu metal from the glass tube to the outside wall of the aluminum housing yields lower stress.

Dahya, Kevin↗

Compact Ozone Lidar for Atmospheric Ozone and Aerosol Measurements

A small compact ozone differential absorption lidar capable of being deployed on a small aircraft or unpiloted atmospheric vehicle (UAV) has been tested. The Ce:LiCAF tunable UV laser is pumped by a quadrupled Nd:YLF laser. Test results on the laser transmitter demonstrated 1.4 W in the IR and 240 mW in the green at 1000 Hz. The receiver consists of three photon-counting channels, which are a far field PMT, a near field UV PMT, and a green PMT. Each channel was tested for their saturation characteristics.

Marcia, Joel↗

Gain control of photomultiplier tubes used in detecting differential absorption lidar returns

A technique for controlling the gain of a photomultiplier tube (PMT) 20. A voltage divider (resistors 45-49 in FIG. 1 and zener diodes 60-65 in FIG. 3) is used to control the potentials on dynodes 5, 7, and 9 of PMT 20. Transistor switches 53 and 58 provide the control of the voltage divider in FIG. 1 and photodiodes 66, 67 and 70 provide the control in FIG. 3. The gain control of PMT 20 is in the range from 100% to less than 0.001% (100,000 to 1).

Allen, Robert J.↗

Software Tools Streamline Project Management

Three innovative software inventions from Ames Research Center (NETMARK, Program Management Tool, and Query-Based Document Management) are finding their way into NASA missions as well as industry applications. The first, NETMARK, is a program that enables integrated searching of data stored in a variety of databases and documents, meaning that users no longer have to look in several places for related information. NETMARK allows users to search and query information across all of these sources in one step. This cross-cutting capability in information analysis has exponentially reduced the amount of time needed to mine data from days or weeks to mere seconds. NETMARK has been used widely throughout NASA, enabling this automatic integration of information across many documents and databases. NASA projects that use NETMARK include the internal reporting system and project performance dashboard, Erasmus, NASA s enterprise management tool, which enhances organizational collaboration and information sharing through document routing and review; the Integrated Financial Management Program; International Space Station Knowledge Management; Mishap and Anomaly Information Reporting System; and management of the Mars Exploration Rovers. Approximately $1 billion worth of NASA s projects are currently managed using Program Management Tool (PMT), which is based on NETMARK. PMT is a comprehensive, Web-enabled application tool used to assist program and project managers within NASA enterprises in monitoring, disseminating, and tracking the progress of program and project milestones and other relevant resources. The PMT consists of an integrated knowledge repository built upon advanced enterprise-wide database integration techniques and the latest Web-enabled technologies. The current system is in a pilot operational mode allowing users to automatically manage, track, define, update, and view customizable milestone objectives and goals. The third software invention, Query-Based Document Management (QBDM) is a tool that enables content or context searches, either simple or hierarchical, across a variety of databases. The system enables users to specify notification subscriptions where they associate "contexts of interest" and "events of interest" to one or more documents or collection(s) of documents. Based on these subscriptions, users receive notification when the events of interest occur within the contexts of interest for associated document or collection(s) of documents. Users can also associate at least one notification time as part of the notification subscription, with at least one option for the time period of notifications.

Source record↗

The Chicagoland Observatory Underground for Particle Physics cosmic ray veto system

A photomultiplier (PMT) readout system has been designed for use by the cosmic ray veto systems of two warm liquid bubble chambers built at Fermilab by the Chicagoland Observatory Underground for Particle Physics (COUPP) collaboration. The systems are designed to minimize the infrastructure necessary for installation. Up to five PMTs can be daisy-chained on a single data link using standard Category 5 network cable. The cables is also serve distribute to low voltage power. High voltage is generated locally on each PMT base. Analog and digital signal processing is also performed locally. The PMT base and system controller design and performance measurements are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Replacement of a Photomultiplier Tube with Silicon Photomultipliers for use in Safeguards Applications

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor scintillating materials for radiation detection purposes. The systems are sometimes limited by disadvantages in the PMTs that may degrade their performance, including temperature dependence and variation with magnetic field. Instrumentation engineering must also contend with a potentially large volume relative to the active scintillator volume, fragility, and high voltage requirements. One possible alternative is an array of silicon photomultipliers (SiPMs). Measurements were made with a 5.04x5.04-cm sensL J-series SiPM array and a 7.62cm Hamamatsu PMT. We demonstrated how the SiPM bias can be sufficiently altered to remove the effects of temperature variation encountered in environments where nuclear safeguards work is often performed. Finally, we evaluated a method of determining enrichment levels of 235 U at various levels and shielding configurations, using both the PMT-mounted and SiPM-mounted scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]↗

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. Finally, the characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 90 ° bend curved light-guide for TOF scintillating detectors

We report here a bench study of TOF resolution using a 90° bend curved solid light-guide (LG) used to transport the light from a plastic scintillator counter to a photomultiplier (PMT). The 90° LG allows the rotation of the PMT axis to be vertical to the detector axis, in an environment featured by a strong magnetic field along the detector surface, or other geometrical constrains. We show that with a TOF counter of 2000 x 100 x 60 mm 3 and light read-out by PMTs at its two 100 × 60 mm 2 sides, when 90° LG benders are used between the scintillating bar and the PMTs on both sides, the TOF resolution is worsen, by 5–10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operation of Inertial Electrostatic Confinement Fusion (IECF) Device Using Different Gases

An optical signal of IEC plasma using different gases has been registered by means of an optical fiber and photomultiplier (PMT). The light passing through the fiber is directed to the entrance window of a photomultiplier (PMT, Hamamatsu R955), connected to the digital scope. The discharge current of plasma discharge has been recorded using current probe. The X-ray emission in IEC plasma device was investigated by employing time-resolved detector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the Hamamatsu R11780 12 in. photomultiplier tube

Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12 in. PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and high quantum efficiency versions, a preliminary measurement of the absolute quantum efficiency of the standard quantum efficiency version, and a two-dimensional scan of the relative efficiency across the photocathode surface are presented in this paper. All single photoelectron investigations were made using a Cherenkov light source at room temperature at a gain of 1×10 7 . These results show that the R11780 PMT is an excellent candidate for such large optical detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]↗

XFEL structures of the human MT2 melatonin receptor reveal the basis of subtype selectivity

The human MT 1 and MT 2 melatonin receptors are G-protein-coupled receptors (GPCRs) that help to regulate circadian rhythm and sleep patterns. Drug development efforts have targeted both receptors for the treatment of insomnia, circadian rhythm and mood disorders, and cancer, and MT 2 has also been implicated in type 2 diabetes. Here in this paper we report X-ray free electron laser (XFEL) structures of the human MT 2 receptor in complex with the agonists 2-phenylmelatonin (2-PMT) and ramelteon6 at resolutions of 2.8 Å and 3.3 Å, respectively, along with two structures of function-related mutants: H208 5.46 A (superscripts represent the Ballesteros–Weinstein residue numbering nomenclature7) and N86 2.50 D, obtained in complex with 2-PMT. Comparison of the structures of MT 2 with a published structure of MT 1 reveals that, despite conservation of the orthosteric ligand-binding site residues, there are notable conformational variations as well as differences in [ 3 H]melatonin dissociation kinetics that provide insights into the selectivity between melatonin receptor subtypes. A membrane-buried lateral ligand entry channel is observed in both MT 1 and MT 2 , but in addition the MT 2 structures reveal a narrow opening towards the solvent in the extracellular part of the receptor. We provide functional and kinetic data that support a prominent role for intramembrane ligand entry in both receptors, and suggest that there might also be an extracellular entry path in MT 2 . Our findings contribute to a molecular understanding of melatonin receptor subtype selectivity and ligand access modes, which are essential for the design of highly selective melatonin tool compounds and therapeutic agents.