Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 240”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

FRAM v5.2 estimation of plutonium and uranium isotopics using digitized 3-D position-sensitive CdZnTe detectors

Gamma-ray spectroscopy is an important tool used in international safeguards to measure plutonium and uranium isotopics. Recently developed, digital, 3-D position-sensitive CdZnTe gamma-ray spectrometers are promising for safeguards, offering improved performance over commonly available CdZnTe systems, with energy resolutions approaching that of high-purity germanium. CdZnTe gamma-ray spectra from plutonium and uranium samples were processed using the commercially available software FRAM v5.2, a tool that estimates plutonium and uranium isotopics from high-purity germanium spectra, across a wide range of materials. Furthermore using digital CdZnTe systems 239 Pu/ 240 Pu isotopic composition and effective 240 Pu percentage are evaluated to within less than 3 sigma statistical measurement uncertainty across reactor to weapons-grade samples, while low and highly-enriched uranium are easily distinguished.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Separation Of Uranium And Plutonium Isotopes For Measurement By Multi Collector Inductively Coupled Plasma Mass Spectroscopy

Uranium (U) and plutonium (Pu) isotopes in coral soils, contaminated by nuclear weapons testing in the northern Marshall Islands, were isolated by ion-exchange chromatography and analyzed by mass spectrometry. The soil samples were spiked with {sup 233}U and {sup 242}Pu tracers, dissolved in minerals acids, and U and Pu isotopes isolated and purified on commercially available ion-exchange columns. The ion-exchange technique employed a TEVA{reg_sign} column coupled to a UTEVA{reg_sign} column. U and Pu isotope fractions were then further isolated using separate elution schemes, and the purified fractions containing U and Pu isotopes analyzed sequentially using multi-collector inductively coupled plasma mass spectrometer (MCICP-MS). High precision measurements of {sup 234}U/{sup 235}U, {sup 238}U/{sup 235}U, {sup 236}U/{sup 235}U, and {sup 240}Pu/{sup 239}Pu in soil samples were attained using the described methodology and instrumentation, and provide a basis for conducting more detailed assessments of the behavior and transfer of uranium and plutonium in the environment.

54 ENVIRONMENTAL SCIENCES↗

Systematic effects in neutron coincidence and multiplicity counting

Correlated neutron counting, including neutron coincidence and multiplicity counting, is an important tool in nuclear material accountancy verification. The accuracy of such measurements is of interest to the safeguards community because as the accuracy of NDA improves, the number of samples that are required to undergo destructive analysis (DA) decreases. The accuracy of a neutron mUltiplicity measurement can be affected by a number of variables. Monte Carlo neutron transport simulations with MCNPX have been performed to understand how the properties of the sample affect the count rate. These resultant count rates have been analyzed with the 'point model' in order to determine the effect on the deduced plutonium mass. The sample properties that have been investigated are density, sample position within the detector cavity, moisture content, isotopic composition, plutonium to total actinide ratio and heavy metal fraction. These parameters affect the Singles, Doubles and Triples count rates in different ways. In addition, different analysis methods use these measured quantities in different combinations, so that the final sensitivity of the {sup 240}Pu mass to each parameter also depends on the analysis method used. For example, the passive calibration curve method only used the Doubles rate to produce the {sup 240}Pu mass and so is not sensitive to changes in the Singles rate (to first order). The analysis methods considered here were passive calibration curve (non-multiplication corrected), known alpha (multiplication corrected) and multiplicity with known efficiency. The effects were studied on both a small mass MOX sample (1 g Pu) and a large MOX sample (6000 g Pu) both measured in high efficiency neutron multiplicity counters. In order to determine the final effect of each parameter it is necessary to know not only the sensitivity of the plutonium mass to that parameter, but also the range over which the parameter can realistically vary. Some estimates are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multiple ion counter total evaporation (MICTE) method for precise analysis of plutonium by thermal ionization mass spectrometry

This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240 Pu isotope. Accurate analysis of <1 femtogram of 240 Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization mass spectrometry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications

Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SUBSURFACE MOBILE PLUTONIUM SPECIATION: SAMPLING ARTIFACTS FOR GROUNDWATER COLLOIDS

A recent review found several conflicting conclusions regarding colloid-facilitated transport of radionuclides in groundwater and noted that colloids can both facilitate and retard transport. Given these contrasting conclusions and the profound implications even trace concentrations of plutonium (Pu) have on the calculated risk posed to human health, it is important that the methodology used to sample groundwater colloids be free of artifacts. The objective of this study was: (1) to conduct a field study and measure Pu speciation, ({sup 239}Pu and {sup 240}Pu for reduced-Pu{sub aq}, oxidized-Pu{sub aq}, reduced-Pu{sub colloid}, and oxidized-Pu{sub colloid}), in a Savannah River Site (SRS) aquifer along a pH gradient in F-Area, (2) to determine the impact of pumping rate on Pu concentration, Pu speciation, and Pu isotopic ratios, (3) determine the impact of delayed sample processing (as opposed to processing directly from the well).

54 ENVIRONMENTAL SCIENCES↗

Collaborative Research: Natural Organic Matter and Microbial Controls on Mobilization/Immobilization of I and Pu in Soils and Waters Affected by Radionuclide Releases in USA and Japan

In this project, the relationship between natural organic matter (NOM) and two radioactive elements that are relevant to nuclear waste disposal were studied: Plutonium (Pu) and Iodine. The human and environmental risks associated with Pu stem mainly from the very long half-lives of several of its isotopes ( 238 Pu, 88 yr; 239 Pu, 24,100 yr; 240 Pu, 6560 yr) and its radiotoxicity. Understanding Pu biogeochemical behavior in both near-field (>10-11M) and far-field scales (<10-11M) is imperative to the development of approaches for reprocessing Pu, remediation of Pu contamination and accurate assessment of risks posed by disposal practices for Pu-bearing wastes. The environmental mobility of Pu can be affected by redox potential, pH, adsorption, precipitation, complexation, colloid formation, and microbial activity, of which the first characteristic has the most profound influence. Numerous studies have shown high affinity of Pu towards NOM, as well as to mineral phases. NOM is ubiquitous in the environment, e.g., both fulvic and humic acids are able to reduce Pu(V,VI) to Pu(IV) and the redox potential of NOM is positively related to the abundance of phenolic/acidic OH groups. NOM can either facilitate or limit actinide migration, depending on specific biogeochemical conditions including pH, mineral and organic matter characteristics, etc. The other radionuclide of interest is radioiodine ( 129 I). 129I is a major by-product of nuclear fission and of serious concern to the Department of Energy (DOE) as it is among the top risk drivers at existing and potential radiowaste-contaminated sites. The risk of 129 I stems largely from its high bioconcentration factor (90% of the body’s iodine is accumulated in the thyroid), a high inventory at source terms, a very long-half life (16M years), and rapid mobility in the subsurface environment. As a consequence, 129 I has the lowest drinking water standard (1 pCi/L) among all radionuclides in the Federal Register. With a novel and sensitive gas chromatography-mass spectrometry (GC-MS) method developed in our lab, it is possible to quickly and simultaneously determine the distribution of 129 I and stable 127 I forms in environments, as low as 2 pCi/L for 129 I. This method was subsequently validated using accelerator mass spectroscopy, AMS. IO 3 - and organo-I were determined as major species in the groundwater of SRS and the Hanford Site, contrary to thermodynamic predictions that I- should be the dominant species at these sites. Mobility of 129 I was also demonstrated to depend greatly on the I species and its concentration, sediment pH, and redox state, with times to achieve equilibrium taking up to 12 weeks. Along the groundwater pathway in the F-Area of SRS, 129 I- supplied from the seepage basins was transformed to 129 IO 3 - and organo- 129 I with increasing iodine sediment sorption, causing the lower total 127 I and 129 I concentrations along the gradient transect of the waste plume. By contrast, groundwater 129 I concentrations in the wetlands (as high as 1617.3 pCi/L) were greatly elevated with respect to the source term (159.3 pCi/L). While the NOM promoted the uptake of 129 I to the wetland sediment, it also promoted the formation of soluble organic fraction. A small fraction of NOM that is bound to iodine can behave as a mobile organo-I source. Iodide was enzymatically incorporated into NOM, whereas both iodide and iodate were abiotically bound to NOM, under certain conditions. Iodate removal from the mobile aqueous phase can also occur through incorporation into carbonate (e.g., at the Hanford Site, USA). Thus immobilization and re-mobilization of iodine species were influenced by pH, Eh and the presence of NOM and metal oxides, which adds to the complexity of site remediation action. A ground-breaking result was to elucidate the products (i.e. organo-iodine moieties formed via enzymatic and non-enzymatic processes) at the molecular level by nuclear magnetic resonance (NMR) and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). We found that iodine-NOM interactions may be influenced by NOM hydrophobic aliphatic moieties. From the perspective of ESI-FTICRMS, organo-iodine formulas were ascribed to the groups of unsaturated hydrocarbons, lignins and proteins. Iodate is likely abiotically reduced to reactive iodine species by lignin- and tannin-like compounds or carboxylic-rich alicyclic molecules (CRAM). We also investigated microbial mechanisms in iodine incorporation into NOM. We established that soil bacteria isolated from F-Area of SRS did not accumulate significant amounts of I- (0.2-2%). Intracellular uptake of I- decreases with increasing pH when pH ranged from 4 to 6. In contrast, 44 out of 84 strains isolated from the F-Area of SRS can transform I- to IO 3 - and organo-iodine. In some cases, oxidation was facilitated in the presence of H 2 O 2 . Microbes can also excrete organic acids that enhance I- oxidation by lowering the ambient pH and reacting with H 2 O 2 to form peroxy carboxylic acids. At lower pH values (≤5), H 2 O 2 hydrolysis was the driving force for iodide-oxidation; whereas, at pH ≥ 6, spontaneous decomposition of peroxy carboxylic acids, originating from H 2 O 2 and organic acids were the primary cause of iodide oxidation. Lastly, it was determined that microbial processes involved in Mn (II) are capable of directly oxidizing I- via enzymatic catalysis (i.e., multicopper oxidases), or indirectly through the formation of reactive oxygen species (ROS) and/or biogenic manganese oxides. ROS-mediated oxidation of I- was found to predominate at pH >5, whereas the enzymatic and Mn oxide pathways were more active at pH < 5. Together, this project has resulted in 9 publications in high-impact journals, and the training of 1 Ph.D and 4 undergraduate students.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity and Uncertainty Analysis of Plutonium and Cesium Isotopes in Modeling of BR3 Reactor Spent Fuel

Nuclear forensics has a broad task to characterize recovered nuclear or radiological material and interpret the results of investigation. One approach to isotopic characterization of nuclear material obtained from a reactor is to chemically separate and perform isotopic measurements on the sample and verify the results with modeling of the sample history, for example, operation of a nuclear reactor. The major actinide plutonium and fission product cesium are commonly measured signatures of the fuel history in a reactor core. This study investigates the uncertainty of the plutonium and cesium isotope ratios of a fuel rod discharged from a research pressurized water reactor when the location of the sample is not known a priori. A sensitivity analysis showed overpredicted values for the 240 Pu/ 239 Pu ratio toward the axial center of the rod and revealed a lower probability of the rod of interest (ROI) being on the periphery of the assembly. The uncertainty analysis found the relative errors due to only the rod position and boron concentration to be 17% to 36% and 7% to 15% for the 240 Pu/ 239 Pu and 137 Cs/ 135 Cs ratios, respectively. Lastly, this study provides a method for uncertainty quantification of isotope concentrations due to the location of the ROI. Similar analyses can be performed to verify future chemical and isotopic analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER - 551: Experiment for Unresolved Resonance of Plutonium Actinides (EUROPA): CED-1 for True Intermediate Pu Benchmark

IER-551 or the Experiment for Unresolved Resonance Of Plutonium Actinides (EUROPA), is an experiment campaign to design and execute a series of true intermediate energy plutonium critical configurations. EUROPA is a collaboration between Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), and the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN) to validate current and future evaluations of 239,240 Pu isotopes. Preliminary designs were optimized using Particle Swarm Optimization to save on computation time and the configuration with highest percentage of intermediate neutrons causing fission found was BeO-Cd. This combination has over 70% of fissions occurring from intermediate energy neutrons. Secondary considerations regarding end benchmark uncertainties and quality of nuclear data resulted in a beryllium metal only experiment proposed as the final system. This final preliminary design achieves 68% intermediate fissions, sensitivities of fission and capture cross sections of 239 Pu of 0.3021 and -0.1610 respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron angular distribution in plutonium-240 spontaneous fission

Nuclear safeguards applications require accurate fission models that exhibit prompt neutron anisotropy. We observed an anisotropic neutron angular distribution, in the laboratory reference frame, because prompt fission neutrons carry momentum from fully accelerated fission fragments. Furthermore, a liquid organic scintillation detector array was used with pulse shape discrimination techniques to produce neutron-neutron cross-correlation time distributions and angular distributions from spontaneous fission in a 252 Cf, a 0.84 g 240 Pu eff metal, and a 1.63 g 240 Pu eff metal sample. The effect of cross-talk, estimated with MCNPX-PoliMi simulations, is removed from neutron-neutron coincidences as a function of the angle between detector pairs. Fewer coincidences were observed at detector angles near 90°, relative to higher and lower detector angles. As light output threshold increases, the observed anisotropy increases due to spectral effects arising from fission fragment momentum transfer to emitted neutrons. Stronger anisotropy was observed in Cf-252 spontaneous fission prompt neutrons than in Pu-240 neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Neutron Reactions for ENDF/B-VII: {sup 232-241}U and {sup 239}Pu

We have completed new evaluations for several actinides in the ENDF/B-VII database and have extensively modified existing evaluations for several other actinides. We compare calculations using the new evaluations with critical assembly reaction rate measurements made at Los Alamos over the past 50 years, covering a range of reactions and differing neutron spectrum and fluence environments. The evaluations are for all neutron-induced reactions with uranium isotopes in the mass range A=232-241 as well as {sup 239}Pu, and mostly cover the incident neutron energy range from keV energies to 30 MeV. We combined the results of these analyses with new evaluations of the resolved and/or unresolved resonance regions from Oak Ridge for {sup 233,235,238}U and with modified ENDF/B-VI resonance evaluations for the other actinides to produce new neutron-induced evaluations spanning the incident neutron energy range from 10{sup -5} eV to 20 or 30 MeV. Major aspects of this analysis are: systematic accumulation of all relevant experimental data; re-normalization of the neutron data to modern standards; assessment of the applicability of several recent optical model potentials for actinide calculations; interpretation of the experimental results in terms of nuclear theory to allow interpolation and extrapolation of the data into unmeasured regions; and finally, assembly of the experimental and theoretical results into formal evaluated nuclear data files that can be processed for use in applied nuclear programs. In this report we discuss the theoretical analysis and evaluation of all the evaluations, with emphasis on incident neutron energies in the range 10 keV to 20 MeV. We present detailed comparisons of critical assembly simulations with the measurements and include tables of the experimental results. The critical assembly measurements include reaction rates for (n,f), (n,{gamma}), and (n,2n) reactions obtained in the Godiva, Jezebel, Topsy, Bigten, and Flattop assemblies. The evaluations described here are on file at the National Nuclear Data Center at Brookhaven National Laboratory in the ENDF/B-VII database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Precision Plutonium Isotopic Compositions Measured on Los Alamos National Laboratory’s General’s Tanks Samples: Bearing on Model Ages, Reactor Modelling, and Sources of Material. Further Discussion of Chronometry

In this study, we re-analyzed late-1940’s, Manhattan Project era Plutonium-rich sludge samples recovered from the ''General’s Tanks'' located within the nation’s oldest Plutonium processing facility, Technical Area 21. These samples were initially characterized by lower accuracy, and lower precision mass spectrometric techniques. We report here information that was previously not discernable: the two tanks contain isotopically distinct Pu not only for the major (i.e., 240 Pu, 239 Pu) but trace ( 238 Pu , 241 Pu, 242 Pu) isotopes. Revised isotopics slightly changed the calculated 241 Am- 241 Pu model ages and interpretations.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Improved precision and accuracy in quantifying plutonium isotope ratios by RIMS

Resonance ionization mass spectrometry (RIMS) holds the promise of rapid, isobar-free quantification of actinide isotope ratios in as-received materials (i.e. not chemically purified). Recent progress in achieving this potential using two Pu test materials is presented. RIMS measurements were conducted multiple times over a period of two months on two different Pu solutions deposited on metal surfaces. Measurements were bracketed with a Pu isotopic standard, and yielded absolute accuracies of the measured Pu-240/Pu-239 ratios of 0.7 and 0.58 %, with precisions (95 % confidence intervals) of 1.49 and 0.91 %. The minor isotope Pu-238 was also quantified despite the presence of a significant quantity of U-238 in the samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reactivity of a Cube, Cylinder, and Sphere

A water-reflected cube of dry plutonium oxide is found to be more reactive than a sphere of the same mass and composition. MCNP6 ® criticality results for a cube, sphere, and cylinder of identical density, mass, and volume are discussed in the context of several hydrogenous reflectors. Similar geometric comparisons are made for a fast metal system based on 240 Pu Jezebel.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Particulate plutonium released from the Fukushima Daiichi meltdowns

Traces of Pu have been detected in material released from the Fukushima Daiichi Nuclear Power Plant (FDNPP) in March of 2011; however, to date the physical and chemical form of the Pu have remained unknown. Here we report the discovery of particulate Pu associated with cesium-rich microparticles (CsMPs) that formed in and were released from the reactors during the FDNPP meltdowns. The Cs-pollucite-based CsMP contained discrete U(IV)O 2 nanoparticles, <~10 nm, one of which is enriched in Pu adjacent to fragments of Zr-cladding. The isotope ratios, 235 U/ 238 U, 240 Pu/ 239 Pu, and 242 Pu/ 239 Pu, of the CsMPs were determined to be ~0.0193, ~0.347, and ~0.065, respectively, which are consistent with the calculated isotopic ratios of irradiated-fuel fragments. Thus, considering the regional distribution of CsMPs, the long-distance dispersion of Pu from FNDPP is attributed to the transport by CsMPs that have incorporated nanoscale fuel fragments prior to their dispersion up to 230 km away from the Fukushima Daiichi reactor site.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗