Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA BEAM INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electron beam injection experiments - The beam-plasma discharge at low pressures and magnetic field strengths

The paper describes electron beam injection experiments which clarify observational results obtained in rocket flights. A column of enhanced density plasma, exceeding the density expected from ionization by primary beam electrons, was observed in a large vacuum system at low magnetic fields (1 to 1.5 G) and low ambient pressures (10 to the minus 6 to 10 to the minus 5 torr). The peak luminosity of the discharge was about 10 times that of the beam alone, and the radius increased by a factor of three. In the absence of the discharge, RF emission is observed at 1.1 to 1.2 times the cyclotron frequency, and a strong band of RF noise with upper frequency cutoff at about the cyclotron frequency is observed in the discharge mode, along with higher frequency noise at or near the plasma frequency. The onset of the plasma discharge is critically dependent on beam current. The described results agree with observations obtained at much higher densities and magnetic fields in fusion research studies.

Bernstein, W.↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Simulations of electromagnetic emissions produced in a thin plasma by a continuously injected electron beam

In this paper, electromagnetic emissions produced in a thin beam-plasma system are studied using two-dimensional particle-in-cell simulations. For the first time, the problem of emission generation in such a system is considered in a realistic formulation allowing for the continuous injection of a relativistic electron beam through a plasma boundary. Specific attention is given to the thin plasma case in which the transverse plasma size is comparable to the typical wavelength of beam-driven oscillations. Such a case is often implemented in laboratory beam-plasma experiments and has a number of peculiarities. Emission from a thin plasma does not require intermediate generation of the electromagnetic plasma eigenmodes, as in an infinite case, and is more similar to the regular antenna radiation. In this work, we determine how efficiently the fundamental and the second harmonic emissions can be generated in previously modulated and initially homogeneous plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3-D effects on viscosity and generation of toroidal and poloidal flows in LHD

Three-dimensional effects on plasma flows have been experimentally studied in the large helical device with 3D configurations. Spontaneous toroidal flow without net driving force using the combination of perpendicular neutral beam injection (NBI) heating and balanced tangential NBI heating has been investigated with two magnetic configurations. Co- and counter-directed spontaneous flows have been observed depending on the collisionality. Toroidal flow shear changes the sign at 0.4<r{sub eff}<0.6 between co- and counter-flowing plasmas, where r{sub eff} is a averaged minor radius. The detailed flow structures have been also examined at the edge region with stochastic magnetic field. A poloidal flow driven by the positive radial electric field has been observed at the open field region just outside of the plasma boundary. At the stochastic region, a shear of poloidal flow has been observed, while no shear of toroidal flow has been observed. The toroidal flow shear changes only in the nested magnetic flux surface region. A difference of density fluctuation property has been observed between co- and counter-flowing plasmas, where toroidal flow shears are formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictions of H-mode performance in ITER

Time-dependent integrated predictive modeling is carried out using the PTRANSP code to predict fusion power and parameters such as alpha particle density and pressure in ITER H-mode plasmas. Auxiliary heating by negative ion neutral beam injection and ion cyclotron heating of He3 minority ions are modeled, and the GLF23 transport model is used in the prediction of the evolution of plasma temperature profiles. Effects of beam steering, beam torque, plasma rotation, beam current drive, pedestal temperatures, sawtooth oscillations, magnetic diffusion, and accumulation of He ash are treated self-consistently. Variations in assumptions associated with physics uncertainties for standard base-line DT H-mode plasmas (with Ip=15 MA, BTF=5.3 T, and Greenwald fraction=0.86) lead to a range of predictions for DT fusion power PDT and quasi-steady state fusion QDT (≡ PDT/Paux). Typical predictions assuming Paux = 50-53 MW yield PDT = 250- 720 MW and QDT = 5 - 14. In some cases where Paux is ramped down or shut off after initial flat-top conditions, quasi-steady QDT can be considerably higher, even infinite. Adverse physics assumptions such as existence of an inward pinch of the helium ash and an ash recycling coefficient approaching unity lead to very low values for PDT. Alternative scenarios with different heating and reduced performance regimes are also considered including plasmas with only H or D isotopes, DT plasmas with toroidal field reduced 10 or 20%, and discharges with reduced beam voltage. In full-performance D-only discharges, tritium burn-up is predicted to generate central tritium densities up to 1016/m3 and DT neutron rates up to 5×1016/s, compared with the DD neutron rates of 6×1017/s. Predictions with the toroidal field reduced 10 or 20% below the planned 5.3 T and keeping the same q98, Greenwald fraction, and Βη indicate that the fusion yield PDT and QDT will be lower by about a factor of two (scaling as B3.5).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct plasma injection scheme with various ion beams

The laser ion source is one of the most powerful heavy ion sources. However, it is difficult to obtain good stability and to control its intense current. To overcome these difficulties, we proposed a new beam injection scheme called 'direct plasma injection scheme'. Following this it was established to provide various species with desired charge state as an intense accelerated beam. Carbon, aluminum and iron beams have been tested.

43 PARTICLE ACCELERATORS↗

The development of the radio frequency driven negative ion source for neutral beam injectors (invited)

Large and powerful negative hydrogen ion sources are required for the neutral beam injection (NBI) systems of future fusion devices. Simplicity and maintenance-free operation favors RF sources, which are developed intensively at the Max-Planck-Institut fuer Plasmaphysik (IPP) since many years. The negative hydrogen ions are generated by caesium-enhanced surface conversion of atoms and positive ions on the plasma grid surface. With a small scale prototype the required high ion current density and the low fraction of co-extracted electrons at low pressure as well as stable pulses up to 1 h could be demonstrated. The modular design allows extension to large source dimensions. This has led to the decision to choose RF sources for the NBI of the international fusion reactor, ITER. As an intermediate step towards the full size ITER source at IPP, the development will be continued with a half-size source on the new ELISE testbed. This will enable to gain experience for the first time with negative hydrogen ion beams from RF sources of these dimensions.

43 PARTICLE ACCELERATORS↗

A photodiode-based neutral particle bolometer for characterizing charge-exchanged fast-ion behavior

A neutral particle bolometer (NPB) has been designed and implemented on Tri Alpha Energy's C-2 device in order to spatially and temporally resolve the charge-exchange losses of fast-ion populations originating from neutral beam injection into field-reversed configuration plasmas. This instrument employs a silicon photodiode as the detection device with an integrated tungsten filter coating to reduce sensitivity to light radiation. Here we discuss the technical aspects and calibration of the NPB, and report typical NPB measurement results of wall recycling effects on fast-ion losses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study of Spectral Lines in Plasmas Heated by Neutral Beam Injection in the TJ-II Stellarator

We summarize the TJ-II stellarator device give an outline of a vacuum ultraviolet spectrometer used for performing spectral surveys specialized plasma studies. Next, we report the main impurities observed in hot plasmas created maintained by electron cyclotron resonance neutral beam injection heating with lithium coated wall conditioning. Finally, we report broad emission structures that have been observed close to strong oxygen emission lines during neutral beam injection heating phases we elucidate their possible origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preferential acceleration and magnetic field enhancement in plasmas with e{sup +}/e{sup −} beam injection

A theoretical model of current filaments predicting preferential acceleration/deceleration and magnetic field enhancement in a plasma with e{sup +}/e{sup −} beam injection is presented. When the e{sup +}/e{sup −} beams are injected into a plasma, current filaments are formed. The beam particles are accelerated or decelerated depending on the types of current filaments in which they are trapped. It is found that in the electron/ion ambient plasma, the e{sup +} beam particles are preferentially accelerated, while the e{sup −} beam particles are preferentially decelerated. The preferential particle acceleration/deceleration is absent when the ambient plasma is the e{sup +}/e{sup −} plasma. We also find that the particle momentum decrease can explain the magnetic field increase during the development of Weibel/filamentation instability. Supporting simulation results of particle acceleration/deceleration and magnetic field enhancement are presented. Our findings can be applied to a wide range of astrophysical plasmas with the e{sup +}/e{sup −} beam injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies on Neutral Beam Injection into the SSPX Spheromak Plasma

In the Sustained Spheromak Physics Experiment, (SSPX) ['Improved operation of the SSPX spheromak', R.D. Wood, D.N. Hill, E.B. Hooper, S. Woodruff1, H.S. McLean and B.W. Stallard, Nucl. Fusion 45 1582-1588 (2005)], plasmas with core electron temperatures reaching up to 500 eV at densities of 10{sup 20}/m{sup 3} have been sustained for several milliseconds, making them suitable as targets for neutral beam injection. High performance and further progress in understanding Spheromak plasma physics are expected if neutral beams are injected into the plasma. This paper presents the results of numerical 1.5 D modeling of the plasma to calculate neutral beam current drive and ion and electron heating. The results are presented for varying initial conditions of density, temperatures and profiles and beam energy, injection angle and power. Current drive efficiency (Ampere/Watt of absorbed power) of up to 0.08 can be achieved with best performance SSPX shots as target. Analyses of neutral beam heating indicate that ion temperatures of up to 1.5 keV and electron temperatures of up to 750 eV can be obtained with injection of about 1 MW of neutral beam for 5-10 ms and with diffusivities typically observed in SSPX. Injection targeting near the magnetic axis appears to be the best for heating and current drive. Effect of the current drive and evolution of SSPX equilibrium are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron self-injection in the proton-driven-plasma-wakefield acceleration

The self-injection process of plasma electrons in the proton-driven-plasma-wakefield acceleration scheme is investigated using a two-dimensional, electromagnetic particle-in-cell method. Plasma electrons are self-injected into the back of the first acceleration bucket during the initial bubble formation period, where the wake phase velocity is low enough to trap sufficient electrons. Most of the self-injected electrons are initially located within a distance of the skin depth c/ω{sub pe} to the beam axis. A decrease (or increase) in the beam radius (or length) leads to a significant reduction in the total charges of self-injected electron bunch. Compared to the uniform plasma, the energy spread, emittance and total charges of the self-injected bunch are reduced in the plasma channel case, due to a reduced injection of plasma electrons that initially located further away from the beam axis.

43 PARTICLE ACCELERATORS↗

Plasma heating, electric fields and plasma flow by electron beam ionospheric injection

The electric fields and the floating potentials of a Plasma Diagnostics Payload (PDP) located near a powerful electron beam injected from a large sounding rocket into the auroral zone ionosphere have been studied. As the PDP drifted away from the beam laterally, it surveyed a region of hot plasma extending nearly to 60 m radius. Large polarization electric fields transverse to B were imbedded in this hot plasma, which displayed large ELF wave variations and also an average pattern which has led to a model of the plasma flow about the negative line potential of the beam resembling a hydrodynamic vortex in a uniform flow field. Most of the present results are derived from the ECHO 6 sounding rocket mission.

Winckler, J. R.↗

Temporal structure of double plasma frequency emission of thin beam-heated plasma

In the work presented here dynamics of spiky microwave emission of a beam-heated plasma near the double plasma frequency in ∼100 GHz band was studied. The plasma is heated by 80 keV, ∼2 MW, sub-ms electron beam that is injected into the multiple-mirror trap GOL-3. The beam-heated plasma diameter is of the order of the emitted wavelength. Modulation of individual emission spikes in the microwave radiation is found. The radiation dynamics observed can be attributed to a small number of compact emitting zones that are periodically distorted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluid-kinetic modeling of a high power density radio frequency inductively coupled positive hydrogen ion source

High power density radio-frequency (RF) inductively coupled positive ion sources are attractive candidates for next-generation neutral beam injection (NBI) systems, where higher injected power and longer pulse lengths are desired without sacrificing source reliability. Operating at absorbed power densities of order $\gt 1~\mathrm{W\,cm}^{-3}$ places these sources in a regime with stronger gas heating, higher dissociation, and non-Maxwellian electron energy distributions. The Large Uniform Plasma for Ionizing Neutrals (LUPIN) is an RF inductively coupled plasma source designed to explore this high power density regime and to provide guidance for a positive ion source upgrade for the DIII-D NBI system. LUPIN is designed to operate at up to 20 kW of RF power at 2 MHz, coupling energy through a cylindrical quartz vessel to achieve target ion current densities of $2100\,\mathrm{A\,m}^{-2}$ . This paper presents fluid-kinetic modeling of LUPIN using the hybrid plasma equipment model where electrons are treated kinetically, and the simulations reveal that electron energy distribution function transitions from nearly Maxwellian in the core to bi-Maxwellian towards the edge. Parametric simulations investigate the effects of RF power, gas pressure, and frequency on plasma density, ion flux, and uniformity. Parametric sweeps reveal that increasing power shifts the primary ionization channel from molecular to atomic with diminishing flux gains due to skin-depth contraction and gas rarefaction. Higher frequency localizes heating and increases $\mathrm{H}_2^+$ and $\mathrm{H}_3^+$ delivery to the grid, while elevated pressure boosts ionization yet hinders ion transport due to increase in collisionality.

inductively coupled plasma↗

Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source

A Cavity Ring-Down (CRD) system was applied to measure the density of negative hydrogen ion (H{sup -}) in vicinity of extraction surface in the H{sup -} source for the development of neutral beam injector on Large Helical Device (LHD). The density measurement with sampling time of 50 ms was carried out. The measured density with the CRD system is relatively good agreement with the density evaluated from extracted beam-current with applying a similar relation of positive ion sources. In cesium seeded into ion-source plasma, the linearity between an arc power of the discharge and the measured density with the CRD system was observed. Additionally, the measured density was proportional to the extracted beam current. These characteristics indicate the CRD system worked well for H{sup -} density measurement in the region of H{sup -} and extraction.

43 PARTICLE ACCELERATORS↗

Isotope effects on transport in LHD

Abstract Isotope effects are one of the most important issues for predicting future reactor operations. Large helical device (LHD) is the presently working largest stellarator/helical device using super conducting helical coils. In LHD, deuterium experiments started in 2017. Extensive studies regarding isotope effects on transport have been carried out. In this paper, the results of isotope effect studies in LHD are reported. The systematic studies were performed adjusting operational parameters and nondimensional parameters. In L mode like normal confinement plasma, where internal and edge transport barriers are not formed, the scaling of global energy confinement time ( τ E ) with operational parameters shows positive mass dependence ( M 0.27 ; where M is effective ion mass) in electron cyclotron heating plasma and no mass dependence ( M 0.0 ) in neutral beam injection heating plasma. The non-negative ion mass dependence is anti-gyro-Bohm scaling. The role of the turbulence in isotope effects was also found by turbulence measurements and gyrokinetic simulation. Better accessibility to electron and ion internal transport barrier (ITB) plasma is found in deuterium (D) plasma than in hydrogen (H). Gyro kinetic non-linear simulation shows reduced ion heat flux due to the larger generation of zonal flow in deuterium plasma. Peaked carbon density profile plays a prominent role in reducing ion energy transport in ITB plasma. This is evident only in plasma with deuterium ions. New findings on the mixing and non-mixing states of D and H particle transports are reported. In the mixing state, ion particle diffusivities are higher than electron particle diffusivities and D and H ion density profiles are almost identical. In the non-mixing state, ion particle diffusivity is much lower than electron diffusivity. Deuterium and hydrogen ion profiles are clearly different. Different turbulence structures were found in the mixing and non-mixing states suggesting different turbulence modes play a role.

Physics↗