Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PFAs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fundamental data for modeling electron-induced processes in plasma remediation of perfluoroalkyl substances

Plasma treatment of per- and polyfluoroalkyl substances (PFAS) contaminated water is a potentially energy efficient remediation method. In this treatment, an atmospheric pressure plasma interacts with surface-resident PFAS molecules. Developing a reaction mechanism and modeling of plasma–PFAS interactions requires fundamental data for electron–molecule reactions. In this paper, we present results of electron scattering calculations, potential energy landscapes and their implications for plasma modelling of a dielectric barrier discharge in PFAS contaminated gases, a first step towards modelling of plasma–water–PFAS intereactions. It is found that the plasma degradation of PFAS is dominated by dissociative electron attachment with the importance of other contributing processes varying depending on the molecule. All molecules posses a large number of shape resonances – transient negative ion states – from near-threshold up to ionization threshold. These states lie in the region of the most probable electron energies in the plasma (4–5 eV) and consequently are expected to further enhance the fragmentation dynamics in both dissociative attachment and dissociative excitation.

54 ENVIRONMENTAL SCIENCES↗

Comprehensive review of combustion ion chromatography for the analysis of total, adsorbable, and extractable organic fluorine

Poly‐ and perfluoroalkyl substances (PFAS) are a class of persistent organic pollutants whose high stability and appreciable water solubility have led to near‐global contamination. PFAS are bioaccumulative toxins that have been linked to a myriad of disorders and have been detected nearly universally in human blood. Liquid chromatography‐tandem mass spectrometry is the most frequent method used for quantitation, though this typically only measures a few dozen of the >14 000 known PFAS and has been shown to account for a small portion of the total organic fluorine present. Sum parameter methods such as total, extractable, and adsorbable organic fluorine have emerged as alternative measurements for PFAS determination. Combustion ion chromatography has become the preferred method for organofluorine measurement where the sorbent or extract containing PFAS is combusted and the emitted hydrofluoric acid (HF) is a measure of the cumulative organofluorine present. Herein we critically review the types of organofluorine measurement, their separation from the sample matrix, and key parameters of the analytical instrument that affect sensitivity, reproducibility, and recovery with regards to PFAS analysis.

Chemistry↗

Launch Complex 39A, SWMU 008 2023 Long-Term Monitoring Report Kennedy Space Center, Florida

The 2023 Long-Term Monitoring (LTM) Report (LTMR) presents the annual and semi-annual groundwater monitoring results for Launch Complex 39A (LC39A), Solid Waste Management Unit (SWMU) 008, at Kennedy Space Center (KSC), Florida. The reporting period covered under this LTMR is from January to December 2023, and represents the first year of site-wide monitoring following Air Sparge (AS) system shutdown at the end of 2022. AS system operation at LC39A began operation in 2015. The AS system consisted of a total of 173 AS wells ranging in depth from 11 to 37 feet below land surface. The overall remedial objective for the AS Interim Measure was to actively decrease concentrations of COCs to less than their respective Florida Department of Environmental Protection Natural Attenuation Default Concentrations, so that LC39A can transition into an LTM program. This objective was achieved in 2022, with 2023 marking Year 1 of the LTM program to monitor the residual groundwater plume. VOC results indicate that COC concentrations have continued to decrease or stabilize, with no rebound observed since AS system shutdown. Vinyl chloride was the only COC detected above its GCTL, with the highest concentration detected at 8.0 μg/L. PFAS results detected 15 different PFAS compounds (out of 32 analyzed) between the six monitoring wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). PFOS was detected in one of the six samples above the FDEP Provisional GCTL at a concentration of 200 ng/L. PFOA was not detected above the FDEP Provisional GCTL in any of the six samples. PFOS and PFOA also currently have United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 ng/L. PFOS was detected in all six samples above the USEPA MCL. PFOA was detected in three of the six samples above the USEPA MCL. Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the six wells. Additional PFAS sampling will occur as part of a PFAS Site Assessment to be conducted in the future. Based on Year 1 LC39A LTM results, recommendations for 2024 are to continue with the second year of LTM in 2024 with the same monitoring well network as Year 1 (18 wells). The three wells that were on a semi-annual schedule will transition to an annual schedule to align with the remaining wells. The next annual event is scheduled for May 2024. The three wells that were found to be inadvertently destroyed will be properly abandoned and a replacement well in the vicinity of former monitoring well 21ST-MW0030I will be installed. This new well will be added to the LTM sampling plan upon installation.

Deborah M. Wilson↗

Mixture Effects of Per- and Polyfluoroalkyl Substances on Embryonic and Larval Sheepshead Minnows ( Cyprinodon variegatus )

Per- and polyfluoroalkyl substances (PFAS) are ubiquitous and persistent environmental contaminants originating from many everyday products. Perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) are two PFAS that are commonly found at high concentrations in aquatic environments. Both chemicals have previously been shown to be toxic to fish, as well as having complex and largely uncharacterized mixture effects. However, limited information is available on marine and estuarine species. In this study, embryonic and larval sheepshead minnows (Cyprinodon variegatus) were exposed to several PFAS mixtures to assess lethal and sublethal effects. PFOS alone was acutely toxic to larvae, with a 96 h LC50 of 1.97 mg/L (1.64–2.16). PFOS + PFOA resulted in a larval LC 50 of 3.10 (2.62–3.79) mg/L, suggesting an antagonistic effect. These observations were supported by significant reductions in malondialdehyde (105% ± 3.25) and increases in reduced glutathione concentrations (43.8% ± 1.78) in PFOS + PFOA exposures compared to PFOS-only treatments, indicating reduced oxidative stress. While PFOA reduced PFOS-induced mortality (97.0% ± 3.03), perfluorohexanoic acid (PFHxA) and perfluorobutanoic acid (PFBA) did not. PFOS alone did not affect expression of peroxisome proliferator-activated receptor alpha (pparα) but significantly upregulated apolipoprotein A4 (apoa4) (112.4% ± 17.8), a downstream product of pparα, while none of the other individually tested PFAS affected apoa4 expression. These findings suggest that there are antagonistic interactions between PFOA and PFOS that may reduce mixture toxicity in larval sheepshead minnows through reduced oxidative stress. Elucidating mechanisms of toxicity and interactions between PFAS will aid environmental regulation and management of these ubiquitous pollutants.

59 BASIC BIOLOGICAL SCIENCES↗

Ineffectiveness of ultrasound at low frequency for treating per- and polyfluoroalkyl substances in sewage sludge

Concerns have been raised about per- and polyfluoroalkyl substances (PFAS) in sewage sludge given the urgent need of finding suitable disposal methods for sludge. Here in this study, we evaluated the effect of ultrasonication on PFAS changes in sewage sludge. It was revealed that although ultrasonication at 20 kHz increased the soluble chemical oxygen demand (SCOD) of treated sewage sludge, this technique was ineffective for degrading perfluoroalkyl acids (PFAAs) and their precursors. Ultrasonic treatment for longer time (>15 min) led to concentration increase of perfluorooctanoic acid (PFOA), perfluoroheptanoic acid (PFHpA), and perfluorohexanoic acid (PFHxA) in the liquid phase, possibly due to their release from disrupted sludge flocs during cavitation. Adding permanganate (10 mM) to the ultrasonic system could also enhance the disruption of sludge particles, resulting in higher concentrations of PFOA and PFHxA in the solid phase and PFOA, PFHpA, PFHxA, and perfluorobutanesulfonic acid (PFBS) in the liquid phase. Overall, ultrasonic pretreatment at 20 kHz and 0.7 W/mL is unlikely to remove PFAS from sewage sludge. Instead, it could increase the risk of PFAS pollution upon final sludge disposal. Effective treatment technologies are thus demanded if PFAS in sludge are regulated.

54 ENVIRONMENTAL SCIENCES↗

Electrothermal mineralization of per- and polyfluoroalkyl substances for soil remediation

Abstract Per- and polyfluoroalkyl substances (PFAS) are persistent and bioaccumulative pollutants that can easily accumulate in soil, posing a threat to environment and human health. Current PFAS degradation processes often suffer from low efficiency, high energy and water consumption, or lack of generality. Here, we develop a rapid electrothermal mineralization (REM) process to remediate PFAS-contaminated soil. With environmentally compatible biochar as the conductive additive, the soil temperature increases to >1000 °C within seconds by current pulse input, converting PFAS to calcium fluoride with inherent calcium compounds in soil. This process is applicable for remediating various PFAS contaminants in soil, with high removal efficiencies ( >99%) and mineralization ratios ( >90%). While retaining soil particle size, composition, water infiltration rate, and cation exchange capacity, REM facilitates an increase of exchangeable nutrient supply and arthropod survival in soil, rendering it superior to the time-consuming calcination approach that severely degrades soil properties. REM is scaled up to remediate soil at two kilograms per batch and promising for large-scale, on-site soil remediation. Life-cycle assessment and techno-economic analysis demonstrate REM as an environmentally friendly and economic process, with a significant reduction of energy consumption, greenhouse gas emission, water consumption, and operation cost, when compared to existing soil remediation practices.

Science & Technology - Other Topics↗

Lithium metal-mediated electrochemical reduction of per- and poly-fluoroalkyl substances

Per- and poly-fluoroalkyl substances (PFAS) have substantial environmental and health hazards. Unfortunately, current degradation routes require high temperatures or corrosive conditions and/or lead to incomplete defluorination and the generation of shorter alkyl chains. Inspired by the lithium-metal battery literature, here we develop an electrochemical degradation process that leverages reactive metals and highly reducing environments. Here, we show that electrodeposited lithium metal can enable 95% degradation and 94% defluorination of perfluorooctanoic acid to LiF without forming any shorter C 2 –C 6 PFAS as end products. Using computational simulations, we find that electron transfer from lithium to perfluorooctanoic acid leads to rapid C–F bond cleavage, fluoride formation and carbon chain fragmentation. We expand the scope to other PFAS compounds and demonstrate substantial degrees of degradation on over 22 different PFAS, plus complete mineralization to inorganic fluorides. Finally, we use the mineralized F − as a fluorine source for the synthesis of fluorinated non-PFAS compounds to complete a circular fluorine loop from waste to valuable product.

Sarkar, Bidushi [Univ. of Chicago, IL (United Stat↗

Novel niobium-doped titanium oxide towards electrochemical destruction of forever chemicals

Electrochemical advanced oxidative processes (EAOP) are a promising route to destroy recalcitrant organic contaminants such as per- and polyfluoroalkyl substances (PFAS) in drinking water. Central to EAOP are catalysis-induced reactive free radicals for breaking the carbon fluorine bonds in PFAS. Generating these reactive species electrochemically at electrodes provides an advantage over other oxidation processes that rely on chemicals or other harsh conditions. Herein, we report on the performance of niobium (Nb) doped rutile titanium oxide (TiO 2 ) as a novel EAOP catalytic material, combining theoretical modeling with experimental synthesis and characterization. Calculations based on density functional theory are used to predict the overpotential for oxygen evolution at these candidate electrodes, which must be high in order to oxidize PFAS. The results indicate a non-monotonic trend in which Nb doping below 6.25 at.% is expected to reduce performance relative to TiO 2 , while higher concentrations up to 12.5 at.% lead to increased performance, approaching that of state-of-the-art Magnéli Ti 4 O 7 . TiO 2 samples were synthesized with Nb doping concentration at 10 at.%, heat treated at temperatures from 800 to 1100 °C, and found to exhibit high oxidative stability and high generation of reactive oxygen free radical species. The capability of Nb-doped TiO 2 to destroy two common species of PFAS in challenge water was tested, and moderate reduction by ~ 30% was observed, comparable to that of Ti 4 O 7 using a simple three-electrode configuration. We conclude that Nb-doped TiO 2 is a promising alternative EAOP catalytic material with increased activity towards generating reactive oxygen species and warrants further development for electrochemically destroying PFAS contaminants.

99 GENERAL AND MISCELLANEOUS↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transcriptional pathways linked to fetal and maternal hepatic dysfunction caused by gestational exposure to perfluorooctanoic acid (PFOA) or hexafluoropropylene oxide-dimer acid (HFPO-DA or GenX) in CD-1 mice

Per- and polyfluoroalkyl substances (PFAS) comprise a diverse class of chemicals used in industrial processes, consumer products, and fire-fighting foams which have become environmental pollutants of concern due to their persistence, ubiquity, and associations with adverse human health outcomes, including in pregnant persons and their offspring. Multiple PFAS are associated with adverse liver outcomes in adult humans and toxicological models, but effects on the developing liver are not fully described. Here we performed transcriptomic analyses in the mouse to investigate the molecular mechanisms of hepatic toxicity in the dam and its fetus after exposure to two different PFAS, perfluorooctanoic acid (PFOA) and its replacement, hexafluoropropylene oxide-dimer acid (HFPO-DA, known as GenX). Pregnant CD-1 mice were exposed via oral gavage from embryonic day (E) 1.5-17.5 to PFOA (0, 1, or 5 mg/kg-d) or GenX (0, 2, or 10 mg/kg-d). Maternal and fetal liver RNA was isolated (N = 5 per dose/group) and the transcriptome analyzed by Affymetrix Array. Differentially expressed genes (DEG) and differentially enriched pathways (DEP) were obtained. DEG patterns were similar in maternal liver for 5 mg/kg PFOA, 2 mg/kg GenX, and 10 mg/kg GenX (R2: 0.46-0.66). DEG patterns were similar across all 4 dose groups in fetal liver (R2: 0.59-0.81). There were more DEGs in fetal liver compared to maternal liver at the low doses for both PFOA (fetal = 69, maternal = 8) and GenX (fetal = 154, maternal = 93). Upregulated DEPs identified across all groups included Fatty Acid Metabolism, Peroxisome, Oxidative Phosphorylation, Adipogenesis, and Bile Acid Metabolism. Transcriptome-phenotype correlation analyses demonstrated > 1000 maternal liver DEGs were significantly correlated with maternal relative liver weight (R 2 >0.92). These findings show shared biological pathways of liver toxicity for PFOA and GenX in maternal and fetal livers in CD-1 mice. The limited overlap in specific DEGs between the dam and fetus suggests the developing liver responds differently than the adult liver to these chemical stressors. This work helps define mechanisms of hepatic toxicity of two structurally unique PFAS and may help predict latent consequences of developmental exposure.

54 ENVIRONMENTAL SCIENCES↗

Predictive Integrated Stratigraphic Modeling Report, Center-wide Per- and Polyfluoroalkyl Substances, Potential Release Location 237, Kennedy Space Center, FL

The National Aeronautics and Space Administration (NASA) is investigating the occurrence of per- and polyfluoroalkyl substances (PFAS) Center-wide at Kennedy Space Center (KSC), Merritt Island, Florida (Figure 1-1) as Potential Release Location 237. AECOM Technical Services, Inc. (AECOM) conducted investigation activities in 2020 and 2021 to develop a better understanding of the fate and transport of PFAS in groundwater and surface water at KSC center-wide using PRedictive Integrated Stratigraphic Modeling (PRISM). PRISM uses best practices from the fields of geology, hydrology, and chemistry to acquire a holistic understanding of the subsurface and more accurately predict contaminant migration pathways. Based on the potential magnitude (frequency and areal distribution) of PFAS impacts at KSC, the analyses described herein were designed to provide tools to address the unique behavior of PFAS chemicals.

PFAS↗

A review of emerging photoinduced degradation methods for per- and polyfluoroalkyl substances in water

The remediation of per- and polyfluoroalkyl substances (PFAS) in water continues to garner significant attention due to their environmental persistence and adverse health effects. Among the various PFAS remediation methods, photoinduced approaches have recently emerged as promising techniques for the degradation of these persistent contaminants. However, many questions remain unanswered regarding the detailed mechanisms in these photoinduced methods as well as the best ways to leverage these approaches for PFAS degradation. In this review, we provide an update on recent experimental and theoretical developments in photoinduced PFAS degradation techniques over the past 2–5 years. We conclude with a perspective of promising research directions in this vibrant area and give recommendations on future experimental and computational approaches needed to further advance these photoinduced remediation capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal–Organic Frameworks for Per- and Polyfluoroalkyl Substances Treatment in Contaminated Water

Per- and polyfluoroalkyl substances (PFAS) are synthetic pollutants known for their chemical stability, environmental persistence, and toxicological risks. Their widespread use has led to extensive contamination, particularly in aquatic systems. Conventional treatment methods often face challenges such as high energy consumption and the production of secondary pollutants. Metal− organic frameworks (MOFs), with their high surface areas and tunable structures, have emerged as promising materials for PFAS remediation. This review summarizes recent progress in MOF-based PFAS adsorption and degradation, highlighting key frameworks such as MIL, UiO, and ZIF. Mechanistic insights into adsorption behavior and regeneration capabilities are discussed, along with the catalytic performance of MOF composites and postmodified systems in degradation pathways. The review concludes with design strategies for next-generation MOF materials aimed at efficient, sustainable PFAS removal under realistic conditions.

Adsorption↗

Copper-Based Two-Dimensional Conductive Metal–Organic Framework Thin Films for Ultrasensitive Detection of Perfluoroalkyls in Drinking Water

Perfluoroalkyls (PFAS) continue to emerge as a global health threat making their effective detection and capture extremely important. Though metal–organic frameworks (MOFs) have stood out as a promising class of porous materials for sensing PFAS, detection limits remain insufficient and a fundamental understanding of detection mechanisms warrants further investigation. Here, in this study, we show the use of a 2D conductive MOF film based on copper hexahydroxy triphenylene (Cu-HHTP) to fabricate chemiresistive sensing devices for detecting PFAS in drinking water. We further show ultrasensitive detection using electrochemical impedance spectroscopy. Owing to excellent electrostatic attractions and electrochemical interactions between the copper-based MOF and PFAS, confirmed by high-resolution spectroscopy and theoretical simulations, the MOF-based sensor reported herein exhibits excellent affinity and sensitivity toward perfluorinated acids at concentrations as low as 0.002 ng/L.

2D metal−organic frameworks↗

Direct measurement of fluorocarbon radicals in the thermal destruction of perfluorohexanoic acid using photoionization mass spectrometry

Thermal destruction is a critical cornerstone of addressing the rampant contamination of natural resources with per- and polyfluoroalkyl substances (PFAS). However, grave concerns associated with stack emissions from incineration exist because mechanistic studies have thus far relied on ex situ analyses of end products and theoretical calculations. Here, we used synchrotron-based vacuum ultraviolet photoionization mass spectrometry to study the pyrolysis of a representative PFAS-perfluorohexanoic acid-and provide direct evidence of fluorocarbon radicals and intermediates. A key reaction pathway from perfluorocarboxylic acids to ketenes via acyl fluorides is proposed. We furthermore propose CF2/CF3 radical-centered pyrolysis mechanisms and explain their roles in the formation of other products that may form in full-scale incinerators. These results have not only unveiled the role of radicals and intermediates in thermal PFAS decomposition and recombination mechanisms but also provide unique insight into improving the safety and viability of industrial PFAS incineration.

Xu, Ming-Gao↗

2022 Results for Avian Monitoring of Inorganic Elements and Organic Chemical Concentrations in Passerine Eggs and Nestlings Collected from Technical Area 16 Burn Grounds, Technical Area 36 Minie, and Technical Area 39 Point 6 at Los Alamos National Laboratory

In 2022, nonviable avian eggs and one nestling were opportunistically collected at Los Alamos National Laboratory (LANL) near open detonation sites located at Technical Area (TA) 16 burn grounds, TA-36 Minie, and TA-39 Point 6. Samples were evaluated for inorganic elements (mostly metals) or per- and polyfluoroalkyl substances (PFAS). Three western bluebird (Sialia mexicana) egg samples were collected from TA-16 burn grounds. One deceased mountain bluebird (Sialia currucoides) nestling sample was collected from TA-36 Minie. One ash-throated flycatcher (Myiarchus cinerascens) egg sample was collected from TA-39 Point 6. Concentrations of inorganic elements (i.e., mostly metals) observed in this study were compared with the regional statistical reference level (RSRL), which is the upper-level bounds of background concentrations (mean + three standard deviations = 99% confidence interval). Several inorganic elements were not detected in avian eggs. All of the inorganic elements that were detected were below the RSRL and the lowest observable adverse effect level (LOAEL), when available. No PFAS compounds were detected in the mountain bluebird nestling sample collected from TA-36, and the majority of PFAS compounds were not detected in the western bluebird egg sample from TA-16. These data suggest that inorganic element and PFAS concentrations in eggs and nestlings are not of ecological concern. More data are needed to make a robust assessment and to evaluate trends over time.

59 BASIC BIOLOGICAL SCIENCES↗

Preliminary Per- and Polyfluoroalkyl Substances Sampling Plan for Pantex Plant

Leidos prepared this Preliminary Per- and Polyfluoroalkyl Substances (PFAS) Sampling Plan for the U.S Department of Energy (DOE) Pantex Plant Consolidated Nuclear Security, LLC (CNS) Pantex, the operations and maintenance (O&M) contractor of Pantex Plant commissioned the Preliminary PFAS Sampling Plan to evaluate the potential risks at the facility and collect preliminary groundwater data at areas within the Plant with the highest potential for PFAS. This plan presents findings from research conducted to assess past and current use of materials containing PFAS and identify areas where these materials were potentially stored, handled, used, or released at Pantex Plant. Pantex Plant is located in Carson County in the Texas Panhandle (Figure 1-1).

54 ENVIRONMENTAL SCIENCES↗