Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Utilizing Gaps and Performance Measures to Inform NASA Environmental Control and Life Support Systems and Human Health and Performance Capability Technology Decisions

Human spaceflight is a complex endeavor requiring multiple capabilities for transportation, crew health, scientific goals, and safe return to Earth. The difference between spaceflight proven capabilities and those needed for future exploration architectures is defined as a capability gap. Capability gaps are not technology specific. Each capability gap may be closed with a wide array of technologies that have unique benefits and challenges. Determining what a capability’s relevant and distinguishing key performance parameters (KPPs) are for a mission is critical. Mass, power, and volume are always constrained and important, but defining these in a way normalized by performance is very important. KPP definition for reliability, dormancy, and integration needs are hard to define but critical. Outside of technical considerations, the programmatic factors of the estimated time to develop the technology and how the technology validation objectives are matured are strong considerations in which technologies should be pursued and how they should leverage earlier mission elements. The Environmental Control and Life Support (ECLSS) and Crew Health and Performance (CHP) capability areas are decomposed to high level gaps. While KPPs should be technology agnostic, they can be used to both compare technologies and measure progress of technology development over time. KPPs help define when the gap is closed, and the core mission objectives can be accomplished. Proposed technology improvements to enhance a capability should balance improved KPPs and against investments in other capabilities that are not yet closed. A selection of gaps, KPPs, and validation objectives and their formulation, current state, and how they inform capability roadmap planning are discussed.

Life Support↗

Utilizing Gaps and Performance Measures to Inform NASA Environmental Control and Life Support Systems and Crew Health and Performance Technology Decisions

Human spaceflight is a complex endeavor requiring multiple capabilities for transportation, crew health, scientific goals, and safe return to Earth. The difference between spaceflight proven capabilities and those needed for future exploration architectures is defined as a capability gap. Capability gaps are not technology specific. Each capability gap may be closed with a wide array of technologies that have unique benefits and challenges. Determining what a capability’s relevant and distinguishing key performance parameters (KPPs) are for a mission is critical. Mass, power, and volume are always constrained and important, but defining these in a way normalized by performance is very important. KPP definition for reliability, dormancy, and integration needs are hard to define but critical. Outside of technical considerations, the programmatic factors of the estimated time to develop the technology and how the technology validation objectives are matured are strong considerations in which technologies should be pursued and how they should leverage earlier mission elements. The Environmental Control and Life Support (ECLSS) and Crew Health and Performance (CHP) capability areas are decomposed to high level gaps. While KPPs should be technology agnostic, they can be used to both compare technologies and measure progress of technology development over time. KPPs help define when the gap is closed, and the core mission objectives can be accomplished. Proposed technology improvements to enhance a capability should balance improved KPPs and against investments in other capabilities that are not yet closed. A selection of gaps, KPPs, and validation objectives and their formulation, current state, and how they inform capability roadmap planning are discussed.

Life Support↗

Frontiers in Scientific Workflows: Pervasive Integration With High-Performance Computing

Herein we address the increasing complexity of scientific workflows in the context of high-performance computing (HPC) and their associated need for robust, adaptable, and flexible computational support systems. We explore five key trends as well as future challenges and opportunities for scientific workflows and HPC technologies.

97 MATHEMATICS AND COMPUTING↗

How to Design and Implement an Equitable Building Performance Standard: Lessons from the Building Performance Standards Technical Assistance Network

States and local governments seek to accomplish the intersecting goals of reducing greenhouse gas emissions, improving building operations, and bettering the daily lives of their communities. Building Performance Standards (BPS) have emerged as a critical policy lever to reach these intertwined climate and societal goals. These policies, if shaped and implemented well, have the chance to not only help reach our nation's climate, energy, and livability goals, but to do so with the active participation of those traditionally excluded from policy processes. This nascent policy movement provides jurisdictions across the country the opportunity to shape these policies from the outset to deliver comfort, health, and safety in our built environment for all. The US Department of Energy in partnership with our National Laboratories have been providing technical assistance for jurisdictions interested in, adopting, and implementing Building Performance Standards. Through this work, the BPS Technical Assistance Network (TA Network) has tracked and documented the innovative and equitable approaches to BPS across the country. The TA Network has crafted foundational technical analysis, such as building stock and emissions impacts, equity prioritization and peak load impacts, and aggregated cost benefit analysis. And by combining powerful technical analysis with dissemination of best practices resources to support equitable implementation, the TA Network provides jurisdictions with the tools and support necessary to embark on their ambitious policy goals.

building performance standards↗

High-Performance Computing for Earth System Modeling

High-performance computing (HPC) plays an important role during the development of Earth system models. This chapter reviews HPC efforts related to Earth system models, including community Earth system models and energy exascale Earth system models. Specifically, this chapter evaluates computational and software design issues, analyzes several current HPC-related model developments, and provides an outlook for some promising areas within Earth system modeling in the era of exascale computing.

Wang, Dali↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tailoring electrode microstructure via ink content to enable improved rated power performance for platinum cobalt/high surface area carbon based polymer electrolyte fuel cells

Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .

25 ENERGY STORAGE↗