Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Intermediate-Temperature Proton Exchange Membranes Based on Cerium Ultraphosphate Composited with Polybenzimidazole

This paper reports the rational fabrication and structural, thermal, mechanical and electrochemical characterization of a new type of intermediate-temperature (IT) polymer-inorganic composite (PIC) proton exchange membranes (PEMs) that are made of cerium ultraphosphate (CeP 5 O 14 —CUP) as the solid-state proton conductor composited with a high-temperature (HT) polybenzimidazole (PBI) as the polymeric binder. Here, flexible PBI-CUP PIC membranes with the thickness of ~135 μ m and CUP mass fraction of up to 75% were prepared by solution-casting without additional acid-doping (e.g., phosphoric acid). The proton conductivity of the fabricated IT-PIC-PEMs was up to 5.80 × 10 –2 S cm –1 as measured from a prototype IT PEM fuel cell (PEMFC) operated at 200 °C in the humidified hydrogen and air environment. This type of IT-PIC-PEMs also demonstrated sufficient mechanical strength and flexibility, excellent thermal stability (up to 350 °C), and very good durability of the proton conductivity (within the test duration of 500 h). The present experimental study shows the promising future of the IT-PIC-PEMs for applications in various IT electrochemical processes including IT-PEMFCs, IT-electrolyzers, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water Dynamics of Superacid Aromatic Proton Exchange Membranes for Fuel Cell Applications

Proton exchange membranes (PEMs) with high conductivity are of critical importance for the development of fuel cells, electrolyzers, and other electrochemical technologies. In this research, poly(1,1,2,2-tetrafluoro-2-phenoxyethane-1-sulfonic acid) (PTPS) with an aromatic polymer main chain and a perfluorinated superacidic polymer side chain was synthesized. The water dynamics of PTPS were characterized across various length scales using a combination of Fourier-transform infrared spectroscopy (FTIR) and nuclear magnetic resonance (NMR) and compared with Nafion, a standard perfluorinated PEM, and sulfonated poly(ether sulfone) (SPES 40), an aromatic PEM without perfluorinated superacid side chains. The T 1 and T 2 relaxation times of water in the samples probed by NMR increase from SPES 40 to PTPS to Nafion, indicating that the local motion of the water molecules becomes faster. This trend corresponds well with the relative fraction of bulk-like water determined using FTIR. At larger length scales, the diffusion coefficient of water was characterized using pulsed-field gradient NMR (PFG-NMR). At a longer diffusion time (Δ = 100 ms), PTPS has a smaller diffusion coefficient compared with both Nafion and SPES 40, due to restricted diffusion, and this effect is also evident in the proton conductivity of the hydrated membranes. From this comparison, it is apparent that the aromatic backbone and side chain type greatly influence the water dynamics in PEMs at various length scales and the water dynamics significantly impact the bulk proton conductivity. These insights will lead to new designs for aromatic PEMs and help to identify bottlenecks in current materials.

25 ENERGY STORAGE↗

High temperature water electrolysis testing of gold-based electrodes for H 2 production

The Hybrid Sulfur (HyS) process is a promising thermochemical water-splitting cycle with global scale hydrogen production potential. The SO 2 -depolarized electrolyzer (SDE) is a critical component of the cycle. At the core of the SDE is the membrane-electrode assembly (MEA), which consists of a polymer electrolyte membrane (PEM) sandwiched between two electrocatalyst layers. New electrocatalyst and membrane materials are being developed with the goals of improving the electrolyzer performance and extending the lifetime of the MEA. In this work, we evaluated the performance of three different membranes and optimized operating conditions, resulting is one of the highest performances in the literature.

08 HYDROGEN↗

Life-cycle analysis of hydrogen production from water electrolyzers

The United States' focus on decarbonization has spawned interest among policymakers in deploying water electrolysis technology for clean hydrogen production. However, water electrolyzers also raise concerns regarding their substantial use of carbon-intensive materials. Here, we conduct a comprehensive life-cycle analysis (LCA) of three prominent water electrolyzer technologies to investigate the environmental implications of their manufacturing and life cycles under different energy sources. All electrolyzer technologies employing low-carbon energy (nuclear, solar, or wind) exhibit life-cycle greenhouse gas (GHG) emissions of 0.3-2.4 kg-CO 2-eq /kg-H 2 . This is significantly lower than the corresponding GHG emissions for hydrogen production via both conventional steam methane reforming and alternative autothermal reforming with carbon capture and storage (by > 50%). The well-to-gate GHG emissions of low-carbon electrolyzers (0-0.36 kg-CO 2-eq / kg-H 2 ) qualify for Tier I of the production tax credit in the U.S.' Inflation Reduction Act of 2022, indicating their suitability for producing decarbonized hydrogen under this program.

08 HYDROGEN↗

Introducing a novel technique for measuring hydrogen crossover in membrane-based electrochemical cells

Hydrogen crossover that is the unwanted hydrogen permeation across the membrane driven by the difference of gas concentrations causes a critical concern of safety and efficiency for electrochemical cells, such as fuel cells and electrolyzer cells. Although the hydrogen crossover measurement in fuel cells that employ platinum based catalysts is simple and widely used in laboratory settings, it is questionable to apply existing limiting current method to water electrolyzer cells and alkaline exchange membrane (AEM) systems, which is due to the typical catalyst materials used and membrane properties, respectively. In this work, we demonstrate the operation of a compact and low-cost method of measuring hydrogen crossover that works for both AEM and proton exchange membrane (PEM) systems. The method entails a tandem configuration that utilizes an upstream crossover cell with a downstream cell in hydrogen pump configuration to measure the crossover in the cell of interest. We have successfully measured the hydrogen crossover with different membranes at various differential pressures. The developed method can be applied to catalyst-free membranes (both PEM and AEM) as well as PGM free catalyst containing cells. It will be a promising technique for measuring hydrogen crossover in-situ for a real operating membraned-based electrochemical cell or stack.

08 HYDROGEN↗

Load following power generation and power storage using REP and PEM technology

A hydrogen generation system for generating hydrogen and electrical power includes a power supply, a reformer-electrolyzer-purifier (REP) assembly including at least one fuel cell including an anode and a cathode separated by an electrolyte matrix, at least one low temperature fuel cell, and a hydrogen storage. The at least one fuel cell is configured to receive a reverse voltage supplied by the power supply and generate hydrogen-containing gas in the anode of the at least one fuel cell. The at least one low temperature fuel cell is configured to receive the hydrogen-containing gas output from the REP assembly. The at least one low temperature fuel cell is configured to selectably operate in a power generation mode in which the hydrogen-containing gas is used to generate electrical power and a power storage mode in which the hydrogen-containing gas is pressurized and stored in the hydrogen storage.

Jahnke, Fred C.↗

Iridium-Doped Ruthenium Oxide Catalyst for Oxygen Evolution

NASA requires a durable and efficient catalyst for the electrolysis of water in a polymer-electrolyte-membrane (PEM) cell. Ruthenium oxide in a slightly reduced form is known to be a very efficient catalyst for the anodic oxidation of water to oxygen, but it degrades rapidly, reducing efficiency. To combat this tendency of ruthenium oxide to change oxidation states, it is combined with iridium, which has a tendency to stabilize ruthenium oxide at oxygen evolution potentials. The novel oxygen evolution catalyst was fabricated under flowing argon in order to allow the iridium to preferentially react with oxygen from the ruthenium oxide, and not oxygen from the environment. Nanoparticulate iridium black and anhydrous ruthenium oxide are weighed out and mixed to 5 18 atomic percent. They are then heat treated at 300 C under flowing argon (in order to create an inert environment) for a minimum of 14 hours. This temperature was chosen because it is approximately the creep temperature of ruthenium oxide, and is below the sintering temperature of both materials. In general, the temperature should always be below the sintering temperature of both materials. The iridium- doped ruthenium oxide catalyst is then fabricated into a PEM-based membrane- electrode assembly (MEA), and then mounted into test cells. The result is an electrolyzer system that can sustain electrolysis at twice the current density, and at the same efficiency as commercial catalysts in the range of 100-200 mA/sq cm. At 200 mA/sq cm, this new system operates at an efficiency of 85 percent, which is 2 percent greater than commercially available catalysts. Testing has shown that this material is as stable as commercially available oxygen evolution catalysts. This means that this new catalyst can be used to regenerate fuel cell systems in space, and as a hydrogen generator on Earth.

Valdez, Thomas I.↗

Complete Phase Transformation of Ir Nanowire Network into Defect-Rich Oxide Catalyst for High-Performance PEM Water Electrolysis

Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.

oxygen evolution reaction↗

Regenerative fuel cell systems for project pathfinder

The objectives of a surface power program, an element of the exploration thrust of the Pathfinder project, and plans for meeting them are outlined. Technological assessment and tradeoff studies of fuel cell and electrolyzer technologies suitable for use in a regenerative fuel cell are described. The viability of proton exchange membranes (PEM) in meeting the system requirements is discussed.

Huff, J. R.↗

NREL's 1MW Water Electrolysis Stack Performance Validation to Pilot-Scale Renewable Natural Gas Production [Slides]

NREL has designed, built, and operates a 1MW water electrolyzer balance-of-plant to support industrial partners and the U.S. Department of Energy in developing next-generation PEM stacks to reduce the cost of hydrogen production. With that hydrogen, we are developing, innovating and de-risking a biomethanation process capable of megawatt-scale deployment that upgrades biogas waste streams to produce pipeline quality renewable natural gas (RNG). Biomethanation is a two-step process using a methanogenic microorganism to convert renewable hydrogen (H 2 ) and waste carbon dioxide (CO 2 ) to renewable methane (CH 4 ) - the primary component in natural gas. Using biogenic CO 2 from biogas sources like dairies, wastewater treatment plants, and landfills allows production of this drop-in direct replacement fuel. Research projects and future R&D topics are also discussed during the presentation.

08 HYDROGEN↗

Reference Station Design for Heavy-Duty Vehicles

Five alternative design configurations for a heavy-duty hydrogen refueling truck stop are detailed in this work. Each of the station concepts provides fast, 5-minute, 50 kg fills of up to 4 vehicles simultaneously, with a station capacity of 4200 kg/day. Two on-site production stations using PEM electrolysis are considered: one with off-peak production of the daily capacity; and one with on-demand production of hydrogen during vehicle refueling. Three delivered liquid hydrogen station concepts are considered: one with the same, high-pressure cascade storage system for dispensing as the electrolysis supplied stations, with low-pressure vaporization of the liquid hydrogen and pressurization via a compressor; and two with on-demand pressurization: one by low-pressure vaporization and compressors; and one with a cryogenic pump and high-pressure vaporization. Design, economic, and operational considerations for each of the components needed in these station concepts is provided. Of all the station concepts, the delivered liquid station with a low-pressure vaporizer and a cascade dispensing system has the lowest capital costs and equipment footprint, but the second highest operating costs primarily due to high costs for liquid hydrogen delivery. The lowest operating cost station is that with on-site production via PEM electrolysis at off-peak hours with a cascade delivery system. The low-pressure buffer storage system and electrolyzers have a large footprint and considerable capital costs, but could result in a low total cost of ownership, depending on the design timeline. The liquid hydrogen station with a cryo-pump has moderate capital costs, the lowest operating costs of the three delivered hydrogen stations, and the same small equipment footprint as the delivered liquid, cascade dispensing system. As cryogenic pumping technology improves and the capital costs for these pumps decreases, this station concept will become even more favorable. Three-dimensional renderings of the five station concepts provide station designers with a starting point for the development of heavy-duty refueling stations.

08 HYDROGEN↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the Advanced Research for Integrated Energy Systems (ARIES) initiative, NREL will build out hydrogen system capabilities at the Flatirons campus. The hydrogen infrastructure at the Flatirons campus will include a research-ready megawatt-scale electrolyzer with hydrogen compression and storage, and a fuel cell system. This hardware will support H2@Scale goals by enabling integrated systems R&D (e.g., to demonstrate grid services, energy storage, renewable hydrogen production, and innovative end-use applications). The system will be coupled with the controllable grid interface at the Flatirons campus and will be designed with flexibility to provide a testbed for integrated electrolyzer R&D, hydrogen utilization R&D, and to study the science of scaling for hydrogen energy systems.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

H2@Scale - Validating an Electrolysis System with High Output Pressure: Cooperative Research and Development Final Report, CRADA Number CRD-18-00741

Electrolysis has been a commercially available product for a while and electrolyzers have been a proven capability to provide additional benefits (e.g. controllable load for grid services) in addition to production of hydrogen. The hydrogen output is typically compressed for storage and dispensing. Compression adds cost and decreases system reliability. Honda’s electrolyzer systems have been developed to include electrochemical compression to leverage the production system itself for at least partial compression. In this project, the team will evaluate Honda’s PEM based electrochemical compression system. The system is capable of compressing hydrogen up to 70 MPa electrochemically. Validation testing is the next step to accelerate this technology into the marketplace, as the validation will provide needed data under a variety of operation conditions and controls. These operating conditions and controls are based on over a decade of NLR research and development with low-temperature electrolysis. The validation testing will include preparing NLR’s site for third party evaluation, benchmark testing of Honda’s stack and system, and simulating operation connected to renewables or in a grid service profile. NLR’s Energy System Integration Lab will be the location for the electrolyzer validation research and integrated into the Hydrogen Infrastructure Test & Research Facility (HITRF). This will build into the existing retail style hydrogen fueling station for a fully integrated experimental setup.

08 HYDROGEN↗

Crosslinked Anionic Exchange Membranes (Spring Quarter Report)

With ever growing climate concerns, studying and optimizing hydrogen gas electrolyzers and fuel cells are of high importance. Polymeric anionic exchange membranes (AEM) are attractive replacements to the industry standard proton exchange membranes (PEM) due to their lack of precious metal catalysts and acidic conditions. However, AEMs on the market have yet to preform comparatively to PEMs. To bring AEMs to a competitive level, crosslinking chemistry within the polymer membranes is being investigated to enhance mechanical properties and performance. For this quarter, electrochemical systems, important AEM properties and considerations, and some characterization methods will be reviewed.

08 HYDROGEN↗

Electrolyzer and method of use

Disclosed are membrane electrode assemblies having a cathode layer comprising a carbon oxide reduction catalyst that promotes reduction of a carbon oxide; an anode layer comprising a catalyst that promotes oxidation of a water; a polymer electrolyte membrane (PEM) layer disposed between, and in contact with, the cathode layer and the anode layer; and a salt having a concentration of at least about 10 uM in at least a portion of the MEA.

Cave, Etosha R.↗

Proton Exchange Membrane (PEM) Water Electrolysis: Cell-Level Considerations for Gigawatt-Scale Deployment

Hydrogen produced with no greenhouse gas emissions is termed “green hydrogen” and will be essential to reaching decarbonization targets set forth by nearly every country as per the Paris Agreement. Proton exchange membrane water electrolyzers (PEMWEs) are expected to contribute substantially to the green hydrogen market. However, PEMWE market penetration is insignificant, accounting for less than a gigawatt of global capacity. Achieving substantive decarbonization via green hydrogen will require PEMWEs to reach capacities of hundreds of gigawatts by 2030. This paper serves as an overarching roadmap for cell-level improvements necessary for gigawatt-scale PEMWE deployment, with insights from three well-established hydrogen technology companies included. Analyses will be presented for economies of scale, renewable energy prices, government policies, accelerated stress tests, and component-specific improvements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗