Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PDV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Regime-oriented causal model evaluation of Atlantic–Pacific teleconnections in CMIP6

The climate system and its spatio-temporal changes are strongly affected by modes of long-term internal variability, like the Pacific decadal variability (PDV) and the Atlantic multidecadal variability (AMV). As they alternate between warm and cold phases, the interplay between PDV and AMV varies over decadal to multidecadal timescales. Here, we use a causal discovery method to derive fingerprints in the Atlantic–Pacific interactions and to investigate their phase-dependent changes. Dependent on the phases of PDV and AMV, different regimes with characteristic causal fingerprints are identified in reanalyses in a first step. In a second step, a regime-oriented causal model evaluation is performed to evaluate the ability of models participating in the Coupled Model Intercomparison Project Phase 6 (CMIP6) in representing the observed changing interactions between PDV, AMV and their extra-tropical teleconnections. The causal graphs obtained from reanalyses detect a direct opposite-sign response from AMV to PDV when analyzing the complete 1900–2014 period and during several defined regimes within that period, for example, when AMV is going through its negative (cold) phase. Reanalyses also demonstrate a same-sign response from PDV to AMV during the cold phase of PDV. Historical CMIP6 simulations exhibit varying skill in simulating the observed causal patterns. Generally, large-ensemble (LE) simulations showed better network similarity when PDV and AMV were out of phase compared to other regimes. Also, the two largest ensembles (in terms of number of members) were found to contain realizations with similar causal fingerprints to observations. For most regimes, these same models showed higher network similarity when compared to each other. This work shows how causal discovery on LEs complements the available diagnostics and statistical metrics of climate variability to provide a powerful tool for climate model evaluation.

54 ENVIRONMENTAL SCIENCES↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

The Spatiotemporal Structure of 20th Century Climate Variations in Observations and Reanalyses: Pacific Pan-Decadal Variability - Part 2

The dominant interannual El Nino-Southern Oscillation phenomenon (ENSO) and the short length of climate observation records make it difficult to study long-term climate variations in the spatiotemporal domain. Based on the fact that the ENS0 signal spreads to remote regions and induces delayed climate variation through atmospheric teleconnections, we develop an ENSO-removal method through which the ENS0 signal can be approximately removed at the grid box level from the spatiotemporal field of a climate parameter. After this signal is removed, long-term climate variations, namely, the global warming trend (GW) and the Pacific pan-decadal variability (PDV), are isolated at middle and low latitudes in the climate parameter fields from observed and reanalyses datasets. In this study, we show that one of several PDV interdecadal regime shifts occurred during the 1990s. This significant change in the Pacific basin is comparable but opposite in phase to the 1976 climate regime shift, which results persisting warming in the central-eastern Pacific, and cooling in the North and South Pacific. The 1990s PDV regime shift is consistent with observed changes in ocean biosphere and ocean circulation. A comprehensive picture of PDV as manifested in the troposphere and at the surface is described. In general, the PDV spatial patterns in different parameter fields share some similarities with the patterns associated with ENSO, but important differences exist. First, the PDV atmospheric circulation pattern is shifted westward by about 20deg and its zonal extent is limited to approx.60deg compared to approx.110deg for ENS0 pattern. The westward shift of the PDV wave train produces a different, more west-east oriented, North American teleconnection pattern. The lack of a strong PDV surface temperature (ST) signal in the western equatorial Pacific and the relatively strong ST signal in the subtropical regions are consistent with an atmospheric overturning circulation response that differs from the one associated with ENSO.

Chen, Junye↗

Photon Doppler velocimetry surface return study for common surface preparations

Photon Doppler velocimetry (PDV) is a ubiquitous diagnostic method in dynamic compression experiments. It typically requires the roughening of the test surface to ensure scattering of the probe light back into the PDV probe at non-normal angles of incidence. Although surface scattering plays an essential role in the quality of PDV data, surface scattering properties for common materials and preparations have not previously been studied with specific relevance to PDV. Here, we present detailed measurements of the bidirectional reflectance distribution function for four different surface preparations (Scotch-Brite hand and drill roughened, ball-rolled, and grit blasted) and four different materials (copper, aluminum, stainless steel, and tantalum). These measurements employ a conventional PDV probe and obtain a diffraction limited angular resolution with 10 pW accuracy and 2.6% repeatability. In addition to scattering data, we employ scattering theory and simulations to accurately emulate the measured data. We also present a straightforward method to derive the average scattering distribution from surface profilometry and observe several qualitative aspects of the scattering data that may help to optimize PDV signals.

42 ENGINEERING↗

Comparison of Triature Doppler Velocimetry and VISAR

Triature Photonic Doppler Velocimetry (TDV) is an adaptation of Photonic Doppler Velocimetry (PDV) that rejects common-mode data noise after splitting PDV three ways, with each signal 120° out of phase from each other. Testing has demonstrated that TDV also improves temporal resolution from the typical five nanoseconds of PDV to a subnanosecond range. This paper compares the temporal response of TDV with that of PDV and VISAR [velocity interferometer system for any reflector] in an experiment with a subnanosecond (~120-picosecond rise time) shock source. Laboratory tests were performed using a high-power laser on targets of copper and aluminum. A Buce Marshall fast VISAR with a single-point PDV and a prototype TDV were used. A special probe that combined PDV, TDV, and fast VISAR made simultaneous velocity measurements. Breakout velocities of 1.3 km/second on copper and 2.5 km/second on aluminum were observed, where TDV resolved rise times of ~200 ps. This resolution was better than that of a fast VISAR, which can achieve ~500 ps temporal resolution. Test methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modes and Mechanisms of Pacific Decadal-Scale Variability

The modes of Pacific decadal-scale variability (PDV), traditionally defined as statistical patterns of variance, reflect to first order the ocean's integration (i.e., reddening) of atmospheric forcing that arises from both a shift and a change in strength of the climatological (time-mean) atmospheric circulation. While these patterns concisely describe PDV, they do not distinguish among the key dynamical processes driving the evolution of PDV anomalies, including atmospheric and ocean teleconnections and coupled feedbacks with similar spatial structures that operate on different timescales. In this review, we synthesize past analysis using an empirical dynamical model constructed from monthly ocean surface anomalies drawn from several reanalysis products, showing that the PDV modes of variance result from two fundamental low-frequency dynamical eigenmodes: the North Pacific–central Pacific (NP-CP) and Kuroshio–Oyashio Extension (KOE) modes. Both eigenmodes highlight how two-way tropical–extratropical teleconnection dynamics are the primary mechanisms energizing and synchronizing the basin-scale footprint of PDV. While the NP-CP mode captures interannual- to decadal-scale variability, the KOE mode is linked to the basin-scale expression of PDV on decadal to multidecadal timescales, including contributions from the South Pacific.

54 ENVIRONMENTAL SCIENCES↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Four Channel Time Multiplexed Photonic Doppler Velocimetry using an Optical Switch

Photonic Doppler Velocimetry (PDV) is a diagnostic commonly used in shock physics and dynamic compression experiments to reliably get velocity information from experiments. In PDV systems, a common method of reducing experimental cost is to use time and frequency multiplexing to increase the number of PDV probes. With time multiplexing, interference between probes is a frequent problem. In this report, we look at using a high-speed optical switch to reduce this interference, including measuring the amount of interference generated to determine if it has the potential to affect experiments and integrating a time multiplexing system into an experiment. We find that, when applied to PDV systems, there is approximately (-23.4 ± 0.9) dB of interference measured in the short time Fourier transform between switch inputs. When an optical switch based time multiplexing system was integrated into a dynamic compression experiment, the system was able to successfully combine the signals from four different PDV probes onto a single optical cable without unacceptable levels of interference in the spectrogram. An optical switch based time multiplexing system appears to be a promising method for reducing the cost of fielding larger numbers of PDV probes in an experiment.

47 OTHER INSTRUMENTATION↗

Application and principles of photon-doppler velocimetry for explosives testing

The velocimetry technique PDV is easier to field than its predecessors VISAR and Fabry-Perot, works on a broader variety of experiments, and is more accurate and simple to analyze. Experiments and analysis have now demonstrated the accuracy, precision and interpretation of what PDV does and does not measure, and the successful application of POV to basic and applied detonation problems. We present a selection of results intended to help workers assess the capabilities of PDV. First we present general considerations about the technique: various PDV configurations, single-signal, multisignal (e.g., triature) and frequency-shifted PDV; what types of motion are sensed and missed by PDV; analysis schemes for velocity and position extraction; accuracy and precision of the results; and, experimental considerations for probe selection and positioning. We then present the status of various applications: detonation speeds and wall motion in cylinder tests, breakout velocity distributions from bare HE, ejecta, measurements from fibers embedded in HE, projectile velocity, resolving 2 and 3-D velocity vectors. This paper is an overview of work done by many groups around the world.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

COMPARISON OF THEORY AND MEASUREMENTS OF A TWO-STAGE LIGHT-GAS GUN

A comparison of techniques for obtaining projectile velocity history on a two-stage launcher and discuss gun code accuracy vis-a-vis pressure gauges and the new photonic Doppler velocimetry (PDV) technique is presented. The PDV technique itself is described in a companion paper. The PDV records were differentiated to compute acceleration and, hence, base pressure. Two acceleration episodes are revealed in the data. Base pressure values were compared with measurements from stationary pressure gauges and with predictions of a standard two-stage gun code. The agreement with the pressure gages was satisfactory. Code predictions did not account for the two acceleration stages. However, for the main acceleration episode, the predicted base pressure is in good agreement with the smoothed pressure computed from the PDV record. Both the gauge records and PDV contain short-time pressure spikes which are apparently real. Therefore, use of computed base pressure for projectile design may lead to failures if the projectile is vulnerable to pressure spikes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Frequency-conversion photonic Doppler velocimetry with an inverted circulator

Photonic Doppler velocimetry (PDV) is a fiber-based interferometer used in dynamic compression research. Conventional PDV systems are simple to construct but do not perform well in all measurement conditions, while universal PDV systems that support many different configurations are complex and expensive. A simpler approach is the use of external, inverted circulators which can be added and removed in a modular fashion. This technique permits frequency-conversion measurements with a conventional PDV system. Using a correction to remove baseline effects, frequency conversion systems can resolve low velocity transients that conventional PDV cannot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of an anomalous pressure on a magneto-inertial-fusion load current diagnostic

Recent Magnetized Liner Inertial Fusion experiments at the Sandia National Laboratories Z pulsed power facility have featured a PDV (Photonic Doppler Velocimetry) diagnostic in the final power feed section for measuring load current. In this paper, we report on an anomalous pressure that is detected on this PDV diagnostic very early in time during the current ramp. Early time load currents that are greater than both B-dot upstream current measurements and existing Z machine circuit models by at least 1 MA would be necessary to describe the measured early time velocity of the PDV flyer. This leads us to infer that the pressure producing the early time PDV flyer motion cannot be attributed to the magnetic pressure of the load current but rather to an anomalous pressure. Using the MHD code ALEGRA, we are able to compute a time-dependent anomalous pressure function, which when added to the magnetic pressure of the load current, yields simulated flyer velocities that are in excellent agreement with the PDV measurement. As a result, we also provide plausible explanations for what could be the origin of the anomalous pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LA-R43S6-L1 Postshot Report [Slides]

The Ranchero LA-R43S6-L1 test (formerly referred to as LA-43S-L1. The R specifically designates it is a Ranchero device and the 6 indicates a 6” high explosive charge diameter in anticipation of using larger diameters in the future.) was conducted on 3/8/17 with good success. The experiment was the first test of a “Swooped” Ranchero flux compression generator (FCG), and the load for the test was an aluminum imploding liner. In addition to the swoop, the stator was anodized to provide an insulating layer instead of one or more layers of polyethylene as had been the case for all earlier Ranchero tests. Using the Firing point TA-39-88 capacitor bank, 3.5 MA was delivered to the FCG for the initial magnetic field, and 36.4 MA were delivered to the load having an initial inductance of 2.5 nH. Implosion speeds over 1.1 cm/us were recorded, which exceeds previous LANL solid liner experimental results. The test was diagnosed with 18 PDV channels, 12 of which recorded liner implosion data, and the other 6 of which tracked the FCG armature during flux compression. These armature expansion data recorded during flux compression are the first of their kind, and it was previously unknown, due to unknown effects of the SF 6 in the flux compression volume, whether or not the expansion could be recorded using the PDV technique. Post shot 2D MHD calculations employed a complete external circuit model, and an improved flux diffusion model not available prior to the test. Results from these simulations show very good agreement with the experimental result. Four PDV channels recorded the liner implosion viewed radially outward from the center of the liner. All four of these probes recorded implosion velocities greater that 1 cm/µs, with the cylindrical center displaced by ~2 mm from actual center. Four PDV channels looked at +10° angles from the CMU wall, and four looked at -10° angles. A glide plane interaction is shown moving toward the center of the liner in MHD calculations, and PDV probes provide confirmation. The high explosive (HE) in the LA-R43S6-L1 test was PBX 9501 which had to be glued together in many pieces, and the test was preceded by a camera test to verify that the PBX 9501 could be assembled with acceptable tolerance in glue joints to prevent severing the armature during expansion. The camera test verified an acceptable armature performance, and results are given in complete detail in a post shot report LA-UR-19-20124, and summarized here. This report provides complete detail of the considerable body of data obtained on the test and in the post shot calculations. It is prepared in Power Point for ease of preparation and future review. Shot documentation available in the LANL on-line library are included as references, and non-referenceable documents will be cited and stored in an LA- R43S6-L1 post shot folder stored on an M-6 shared drive. Fabrication drawings are also maintained in an M-6 shared drive and paper files are available from M-6 personnel. This report will be maintained as a PowerPoint document on the shared drive, as well, since included movies will play and graphs from Excel files retain information in the PowerPoint versions. PDF versions are required for clearance and are not to large to send by e-mail.

42 ENGINEERING↗

Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hypercellularity Components of Glioblastoma Identified by High b-Value Diffusion-Weighted Imaging

Purpose: Use of conventional magnetic resonance imaging (MRI) for target definition may expose glioblastomas (GB) to inadequate radiation dose coverage of the nonenhanced hypercellular subvolume. This study aimed to develop a technique to identify the hypercellular components of GB by using high b-value diffusion-weighted imaging (DWI) and to investigate its relationship with the prescribed 95% isodose volume (PDV) and progression-free survival (PFS). Methods and Materials: Twenty-one patients with GB underwent chemoradiation therapy post-resection and biopsy. Radiation therapy (RT) treatment planning was based upon conventional MRI. Pre-RT DWIs were acquired in 3 orthogonal directions with b-values of 0, 1000, and 3000 s/mm{sup 2}. Hypercellularity volume (HCV) was defined on the high b-value (3000 s/mm{sup 2}) DWI by a threshold method. Nonenhanced signified regions not covered by the Gd-enhanced gross tumor volume (GTV-Gd) on T1-weighted images. The PDV was used to evaluate spatial coverage of the HCV by the dose plan. Association between HCV and PFS or other clinical covariates were assessed using univariate proportional hazards regression models. Results: HCVs and nonenhanced HCVs varied from 0.58 to 67 cm{sup 3} (median: 9.8 cm{sup 3}) and 0.15 to 60 cm{sup 3} (median: 2.5 cm{sup 3}), respectively. Fourteen patients had incomplete dose coverage of the HCV, 6 of whom had >1 cm{sup 3} HCV missed by the 95% PDV (range: 1.01-25.4 cm{sup 3}). Of the 15 patients who progressed, 5 progressed earlier, within 6 months post-RT, and 10 patients afterward. Pre-RT HCVs within recurrent GTVs-Gd were 78% (range: 65%-89%) for the 5 earliest progressions but lower, 53% (range: 0%-85%), for the later progressions. HCV and nonenhanced HCV were significant negative prognostic indicators for PFS (P<.002 and P<.01, respectively). The hypercellularity subvolume not covered by the 95% PDV was a significant negative predictor for PFS (P<.05). Conclusions: High b-value DWI identifies the hypercellular components of GB and could aid in RT target volume definition. Future studies will allow us to investigate the role of high b-value DWI in identifying radiation boost volumes and diagnosing progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of window reflections on photonic Doppler velocimetry measurements

Photonic Doppler velocimetry (PDV) has rapidly become a standard diagnostic for measuring velocities in dynamic compression research. While free surface velocity measurements are fairly straightforward, complications occur when PDV is used to measure a dynamically loaded sample through a window. Fresnel reflections can severely affect the velocity and time resolution of PDV measurements, especially for low-velocity transients. Shock experiments of quartz compressed between two sapphire plates demonstrate how optical window reflections cause ringing in the extracted PDV velocity profile. Velocity ringing is significantly reduced by using either a wedge window or an antireflective coating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stress field measurements using quantitative schlieren

Quantitative schlieren analysis is extended here to optically transparent solids in quasi-static and dynamic experiments to measure stress distributions. The quasi-static experiments in polymethyl methacrylate (PMMA) compared refraction angles and stress gradients calculated from schlieren images to the analytical Flamant solution of a line load on a half-space. The quantitative schlieren measurements of the stress field in the thin sample with a load compared well to the analytical solution. The analysis method was then extended to explosive induced shock waves in PMMA. The explosive induced response of PMMA was experimentally studied using high-speed schlieren to visualize the shock propagation in conjunction with Photon Doppler Velocimetry (PDV) to record surface velocity histories. The stress state estimated from the schlieren images was compared to the stress calculated from the PDV measurements. High-speed imaging limitations caused the shock wave to not be fully resolved in the images, but was resolved in the PDV measurement. The stress state behind the shock calculated from the high-speed images followed a similar trend to the stress calculated from the PDV measurements.

Physics↗