Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimisation of the Future Routine Orbit for Mars Express

Mars Express (MEX), the first planetary mission of the European Space Agency (ESA), reached Mars on December 25th 2003. Since then it is performing routine operations. Its operational phase had to cover one Martian year, with the possibility of an extension for a second Martian year (i.e. until November 2007). The end of the mission extension is approaching but, given the good health of the payload instruments and the high science return of the mission, there is a strong will to achieve further extensions. Mars Express is also seen as an important asset, capable to provide relay functions for future Martian missions. The ESA Science Program Committee has recently approved a second extension of the MEX mission until May 2009 and even further extensions are possible. Mars Express has an eccentric quasi-polar orbit with a period of approximately 6.72 hours and a pericentre height of about 300 km. Science observations are mainly performed at pericentre (but not only). In addition the orbit has a resonance of 11 revolutions per 3 Martian days. This means that ground tracks corresponding to orbits separated by 11 revolutions are adjacent, such that a given area can be covered by the on-board camera without leaving gaps. The J2 effect of Mars causes a drift of both ascending node and argument of pericentre. The drift of argument of pericentre makes it possible to observe periodically all Mars latitudes from close distance. Illumination conditions at pericentre are influenced by both the drift of the argument of pericentre and the drift of ascending node, as well as by the rotation of Mars around the Sun. The original MEX routine orbit was optimized for the duration of the nominal mission and extension, such that it produced a balanced share of day-side observations (for the optical instruments) and night-side observations (for the radar). The orbit was thus not optimized for the time beyond the assumed extension. Indeed, the evolution of the ascending node and argument of pericentre would cause in the following years a drift of the pericentre towards night-side observation conditions, hence uninteresting for the optical instruments. In order to prevent this an optimisation process for the future routine orbit has taken place. The share between day-side and night-side observations can be controlled by adjusting the drift of argument of pericentre and ascending node. This can in particular be achieved by changing the semimajor axis, eccentricity and/or inclination. A change of inclination is inefficient compared to a change in semimajor axis and eccentricity, and has therefore been discarded. An in-plane maneuvre can be performed to change both semi-major axis and eccentricity, and thus the period of the orbit. Although an apocentre manoeuvre is cheaper in terms of deltaV, it would result in raising the pericentre height, which is unfavourable for close observations. Hence a pericentre manoeuvre is proposed, which will increase the apocentre height. A repeat cycle is still required to allow mapping areas with adjacent ground tracks, so the change of semimajor axis must result in a new resonance. Resonances 18:5, 25:7 and 7:2 have been considered as potential candidates. The resulting long term evolution of the observation conditions has been analysed. Finally it has been decided to perform a change of orbit to reach the 18:5. Another aspect of the optimisation process is the control of the ground track. The previous MEX reference trajectory included regular maneuvres at every apocentre in order to adjust the orbital period, such that the separation of the ground tracks would be optimal, regardless of the latitude of pericentre. The implementation of the actual delatVs on-board was done partly by optimizing the attitude of reaction-wheel desaturation activities. Despite of it, this strategy has a significant propellant cost, because it prevents to optimize reaction wheel de-saturation activities to minimize propellant consumption. Therore, with the aim at preserving propellant resources for a long time extension it has been agreed to stop the ground-track control. This requires now a more accurate science operation planning, with improved attitude pointing control. Finally, the approach to phase Mars Express to provide back-up relay functions for NASA Phoenix landing is explained. In the context of the routine trajectory optimisation a new requirement for close fly-bys at Phobos, with different observation geometries, has been specified. The approach to fulfill this requirement is explained.

Carranza, Manuel↗

Pinhole Calibrator For Particle-Sizing Instrument

Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.

Hovenac, Edward↗

High-speed particle analysis using forward and backward two-dimensional angular optical scattering

Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized high-speed flying particles. The elastic-scattering intensity pattern from a single particle as a function of spherical coordinate angles θ and ϕ provides detailed information on the particle’s morphology. By use of an ellipsoidal reflector and a high-speed CCD camera, scattering from a CW-laser was detected and resolved over a large angular range (θ from 12° to 168° and ϕ from 0° to 360°) from spherically shaped particles (e.g., amorphous silica and borosilicate glass) flowing through the reflector’s focal plane at speeds of 20 to 30 m/s. The scattering pattern from individual particles flying through the focal plane of the ellipsoid mirror provides insights about a particle’s size, clustering, roughness, and velocity.

Optics and optical instruments↗

Wavefront error simulator for evaluating optical testing instrumentation

A wavefront error simulator has been designed and fabricated to evaluate experimentally test instrumentation for the Large Space Telescope (LST) program. The principal operating part of the simulator is an aberration generator that introduces low-order aberrations of several waves magnitude with an incremented adjustment capability of lambda/100. Each aberration type can be introduced independently with any desired spatial orientation.

Golden, L. J.↗

Report of Optical Radiometric Instruments and Calibration Panel

Measurement and accuracy needs for remote sensing are analyzed. Topics discussed include: (1) in orbit performance degradation due to contamination; (2) increased radiometric accuracy required for detecting small changes over long periods of time in environmental parameters; (3) references for verifying calibration in orbit; (4) high attenuation neutral density filters; (5) the sun as a radiation source for testing; (6) rejection of stray light; (7) development of spectrally flat detectors for flight sensors; and (8) long term stability of sensor components.

Source record↗

Downward-deployed tethered satellite systems, measurement techniques, and instrumentation - A review

This paper describes a number of scheduled and proposed Shuttle-based downward-deployed tethered satellite systems (TSSs) the purpose of which is to determine the structure of the lower thermosphere and to measure the atmospheric and aerodynamic effects in the vicinity of the satellite, the aerothermodynamic effects on the satellite's surface, and the dynamics of the tether and its endmass, the satellite. The instruments for the downward-deployed tethered missions will include mass spectrometers and other density sensors, plasma instrumentation, optical spectrophotometers, magnetometers, and instrumentation to measure the effects on satellite surface (such as the surface temperature, heat transfer, and pressure; gas adsorption on surfaces, chemistry with other gas molecules and surface material, and desorption from the surface; and surface charging).

Brown, Kenneth G.↗

Suppressing Spurious Reflections In An Interferometer

Dynamic-aperture fringe discriminator is simple device enhancing operation of interferometer of spherical-wave-front type used to test lenses, telescopes, and other optical instruments. Device suppresses reflections from surfaces of refractive optical elements in instrument and/or test setup. Reflections from refractive optical components eliminated by blocking half of interferometer aperture.

Steimle, Lawrence J.↗

The Terrestrial Planet Finder Coronagraph Optical Surface Requirements

Coronagraph telescope and instrument optics for spatial frequencies within and beyond the spatial control bandwidth of the wave front control system. Three different wave front control systems are considered: a zero-path difference Michelson interferometer with two deformable mirrors at a pupil image; a sequential pair of deformable mirrors with one placed at a pupil image; and the Visible Nuller spatially-filtered controller. We show that the optical bandwidth limits the useful outer working angle.

telescope requirements↗

STOP Analysis and Optimization of a Very-Low-Distortion Space Instrument: HST WFC3 Case Study

New generation optical instruments with very demanding stability requirements are being proposed and developed for space applications. STOP (Structural-Thermal-Optical Performance) analysis and optimization is crucial in meeting the very tight distortion budgets of these instruments. This presentation outlines STOP analysis and optimization approach in the context of WFC3 (Wide-Field Camera 3), which is a radial instrument designed to replace the Wide-Field Planetary Camera 2 (WFPC2) of the Hubble Space Telescope (HST). WFC3 houses two separate channels, UVIS and IR, and will have greater throughput and sensitivity than WFPC2. WFC3 line-of-sight alignment budget for the UVIS and IR channels are as small as 10 and 20 milli-arcsec, respectively. Its optical bench is the most critical subsystem effecting the optical stability of WFC3 hence our effort concentrates on the design and analysis of the bench and its interfaces. Structural analysis has accompanied the mechanical design of the bench since the initial concept study. A high fidelity structural Finite Element Model (FEM) of the bench has been developed and used for minimizing its thermally induced distortions as well as sizing it to meet the stiffness and strength requirements of a Shuttle launch. The bench is a composite honeycomb panel box structure with a very low planar Coefficient of Thermal Expansion (CTE) of approximately 0.1 ppm/C. Optic components are mounted to super-INVAR inserts bonded into the panels. The bench is kinematically supported on three HST latches via interface struts, which are tailored to exhibit negative CTE to cancel out the thermal motions of the latches. The interface struts also incorporate flexure elements to minimize the mechanical distortions coming into the bench from its enclosure. Bench FEM is coupled with the enclosure FEM to quantify these effects. Short term or on-orbit STOP analysis includes distortion due to the temperature variations of the bench, the struts, and the enclosure. Long term or ground-to-orbit STOP analysis includes distortional effects of gravity release, desorption, and assembly in addition to the ground-to-orbit temperature variations. A rigorous testing program has been implemented for verifying the material properties and the analysis predictions. STOP analysis results demonstrate that both the short-term and the long-term alignment budgets will be met. Presentation will cover design and analysis details that are critical to a successful implementation of the STOP analysis and optimization process.

Kunt, Cengiz↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗

Arc-jet Testing of Continuously Woven Aeroshells–Spiderweave–for Adaptable Deployable Entry Placement Technology

The Adaptable, Deployable Entry Placement Technology (ADEPT) is an entry system that, when deployed, creates a large, umbrella-like drag surface that can be used to decelerate spacecraft during atmospheric entry, resulting in lower entry loads and heating than a rigid aeroshell of equivalent mass. Until needed for entry, the system can remain stowed, enabling missions to overcome launch vehicle fairing diameter constraints. 12-inch diameter umbrella-like articles, similar to a small reentry probe using ADEPT, were tested in the Ames 20-MWAerodynamic Heating Facility. Performance of the test articles built with a novel, continuously woven aeroshell construction (called Spiderweave) is compared against those built with legacy construction styles. In addition, candidate thermal protective layer treatments applied to structurally sensitive regions of the aeroshell are assessed using data from on-board instrumentation as well as facility optical instruments.

ADEPT↗

Science instrumentation package, LST

The projected design of an optical instrument package for the large space telescope includes: a diffraction limited camera; low- and high-dispersion spectrographs; astrometric machines; photometers; polarimeters; F/12 camera; Fourier interferometer; infrared instrumentation; and a very high dispersion spectrographs.

Levin, G.↗

Overview of the Optomechanical Design of the LUVOIR Instruments

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a space telescope being submitted for review to the 2020 Decadal Survey in Astronomy and Astrophysics. Its science objectives include both direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of planet, star, and galaxy formation, the transfer of matter between different galaxies, and the remote sensing of objects within the Solar System. Two architectures have been designed: a 15 m diameter on-axis telescope (LUVOIR-A) and an 8 m off-axis telescope (LUVOIR-B). This paper discusses the opto-mechanical design of the three LUVOIR instruments: the High Definition Imager (HDI), the LUVOIR UV Multi-object Spectrograph (LUMOS), and the Extreme Coronagraph for Living Planetary Systems (ECLIPS). For both the LUVOIR-A and LUVOIR-B variants of each instrument, optical design specifications are presented including first-order constraints, packaging requirements, and optical performance metrics. These factors are used to illustrate the final design of each instrument and LUVOIR as a whole. In addition to the optical designs, mechanical models are presented for each instrument showing the optical mounts, mechanisms, support structure, etc.

Decadal Study↗