Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Evolving theories of change: Rethinking of the effects of office lighting on occupants

This paper proposes an overall theory of change that relates lighting in offices to a holistic view of human responses that contribute to the well-being of office workers. The theoretical model considers how variations in the four fundamental lighting attributes affect visual performance, visual environment, and non-image forming responses. It moves beyond these lighting to address how external factors that are may mediate the effects on the desired lighting related outcomes, which in turn determine the final impact on occupants. The model builds on prior conceptual models of lighting effects and informs design and research planning for office lighting. Ultimately, properly supported task performance can increase occupant motivation but by itself may not achieve the holistic desired impact. Lighting attributes that support a pleasant visual environment and appropriate non-image forming responses can more fully contribute to an occupant’s mood and overall well-being.

Collier, Jessica M.↗

Low power and privacy preserving sensor platform for occupancy detection

A low-cost, low-power, stand-alone sensor platform having a visible-range camera sensor, a thermopile array, a microphone, a motion sensor, and a microprocessor that is configured to perform occupancy detection and counting while preserving the privacy of occupants. The platform is programmed to extract shape/texture from images in spatial domain; motion from video in time domain; and audio features in frequency domain. Embedded binarized neural networks are used for efficient object of interest detection. The platform is also programmed with advanced fusion algorithms for multiple sensor modalities addressing dependent sensor observations. The platform may be deployed for (i) residential use in detecting occupants for autonomously controlling building systems, such as HVAC and lighting systems, to provide energy savings, (ii) security and surveillance, such as to detect loitering and surveil places of interest, (iii) analyzing customer behavior and flows, (iv) identifying high performing stores by retailers.

Velipasalar, Senem↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How much have adverse occupational health outcomes among construction workers improved over time? Evidence from 25 years of medical screening

Background Construction workers have always had a high risk of occupational illnesses. We used 25 years of data from a medical screening program serving older construction workers to determine how much health outcomes have improved over the past 60 years. Methods We investigated changes in relative risk for chest radiographs consistent with pneumoconiosis, COPD by spirometry, lung cancer mortality, and audiometry-assessed hearing impairment among workers participating in a medical screening program. Results were stratified by decade of first construction employment: before 1960, 1960–1969, 1970–1979, 1980–1989, and after 1990. Poisson and Cox regression analyses assessed relative risk by decade adjusted for age, sex, smoking, and years of construction trade work. Results Subjects were 94% male and, on average, 60 years old with 25 years of construction work. When compared to workers employed before 1960, those first employed after 1990 experienced the following reductions in model-adjusted relative risks: chronic obstructive pulmonary disease, 32%; all pneumoconiosis, 68%; parenchymal abnormalities, 35%; pleural abnormalities, 71%; hearing impairment, 20%; and lung cancer mortality, 48%. Risks started to decline in the 1960s with greatest reductions among workers first employed after 1970. Conclusions This study demonstrates the positive impact that adoption of occupational health protections have had over the past 60 years. The greatest risk reductions were observed for outcomes with strong regulatory and legal incentives to reduce exposures and associated risks, such as those associated with inhalation hazards (asbestos and silica), while lowest improvement was for hearing impairment, for which little regulatory enforcement and few prevention incentives have been adopted.

60 APPLIED LIFE SCIENCES↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of Site Occupancy in the M–Pd–Zn (M = Cu, Ag, and Au) γ-Brass Phase by CALculation of PHAse Diagrams Modeling and Rietveld Refinement

The Pd–Zn γ-brass phase provides exciting opportunities for synthesizing site-isolated catalysts with precisely controlled Pd active site ensembles. Introducing a third metallic element into the γ-brass lattice further perturbs the catalytic active site ensembles. Here, in this work, we introduce coinage metallic elements M (M = Cu, Ag, and Au) into the Pd–Zn γ-brass phase and investigate the site occupation factors of each element in the γ-brass lattice. The CALculation of PHAse Diagrams (CALPHAD) modeling approach supported by energetics predicted by the density functional theory and X-ray and neutron diffraction with Rietveld refinement were used to identify the SOF on each Wyckoff site for various M amounts alloyed into the Pd–Zn γ-brass phase. The present analysis unveils the strong preference for Pd occupying the outer tetrahedral (OT) site in the γ-brass lattice, while the coinage metallic elements tend to substitute for Zn on the octahedral (OH) site. The determination of site occupancy in the bulk M–Pd–Zn γ-brass phase provides opportunities to investigate and tailor potential catalytically active site ensembles in the γ-brass phase materials.

36 MATERIALS SCIENCE↗

An efficient random-sampling method for calculating double occupancy of Gutzwiller wave function in single-band 1D and 2D lattices

In this paper, we report a random sampling method for computing the expectation value of physical quantities based on the Gutzwiler variational wave function. As the first application, we calculated the double occupancy, which is a critical quantity for under- standing the correlation effects in many-body systems, for single-band 1D and 2D lattices. We demonstrated that the random sampling scheme is more efficient than an existing Metropolis Monte-Carlo algorithm. For the 1D Hubbard model with only nearest-neighbor hopping, our results are almost identical to the exact analytic solution. We have also studied systems to which analytic solutions are not available, including the 1D lattices with next-nearest-neighbor hopping and 2D lattices. In addition, constraints on real-space con gurations can be easily implemented in the current scheme to further improve the Gutzwiller wave function. As an example, we calculated the double occupancy for 1D Hubbard model by applying the constraint that all double-occupied sites are paired with an empty site. With enhanced correlation between double-occupied and empty sites, the constraint results in much improved ground-state energy for 1D Hubbard model with strong on-site repulsion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Residential Demand Flexibility: Modeling Occupant Behavior using Sociodemographic Predictors

Demand flexibility (DF) has the potential to increase the saturation of renewables in the grid and reduce operating costs for both utilities and customers. However, less than 8% of U.S. residential electric customers are enrolled in DF programs. A major research gap on this topic is an uneven understanding of behavioral drivers of electricity use and DF program participation at the household level. In this study, we employ machine learning models to predict residential occupant behavior in activities relevant to DF. We model occupants' extensive decisions (i.e., choice of action) and intensive behaviors (i.e., amount of time spent) during peak and off-peak time periods using the publicly available American Time Use Survey, which includes activities data for approximately 200,000 respondents. In our machine learning models, predictions for both extensive and intensive behavior fell within a +/-20% error margin at the aggregate level. We identify 13 key sociodemographic predictors of DF-related intensive behavior using LASSO inference and beta coefficient ranking. However, these top predictors differ by activity, suggesting potential scope for differential user targeting for DF events and technologies during program design. This work also contributes to understanding when and who might adopt these DF technologies based on their daily routine activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-cell quantification of ribosome occupancy in early mouse development

Translation regulation is critical for early mammalian embryonic development. However, previous studies had been restricted to bulk measurements, precluding precise determination of translation regulation including allele-specific analyses. Here, to address this challenge, we developed a novel microfluidic isotachophoresis (ITP) approach, named RIBOsome profiling via ITP (Ribo-ITP), and characterized translation in single oocytes and embryos during early mouse development. We identified differential translation efficiency as a key mechanism regulating genes involved in centrosome organization and N 6 -methyladenosine modification of RNAs. Our high-coverage measurements enabled, to our knowledge, the first analysis of allele-specific ribosome engagement in early development. These led to the discovery of stage-specific differential engagement of zygotic RNAs with ribosomes and reduced translation efficiency of transcripts exhibiting allele-biased expression. By integrating our measurements with proteomics data, we discovered that ribosome occupancy in germinal vesicle-stage oocytes is the predominant determinant of protein abundance in the zygote. The Ribo-ITP approach will enable numerous applications by providing high-coverage and high-resolution ribosome occupancy measurements from ultra-low input samples including single cells.

59 BASIC BIOLOGICAL SCIENCES↗

Seasonal changes in occupancy and activity patterns in native Collared Peccary and non-native wild pig and Common Warthog in southern Texas, the United States

Abstract Southern Texas, USA, is home to native collared peccaries (Dicotyles tajacu) and introduced populations of invasive wild pigs (generally Sus scrofa × domesticus hybrids) and non-native African warthogs (Phacochoerus africanus). Although these ecologically similar mammals co-occur in this region, the potential impacts of invasive suids on collared peccaries are poorly understood. We examined co-occupancy and activity pattern overlap of collared peccaries, wild pigs, and warthogs across 3 seasons (fall, winter, and spring) using remote camera data collected from Chaparral Wildlife Management Area, Cotulla, Texas (November 2020 to June 2021). Using activity pattern analyses and single and 2-species occupancy models incorporating habitat and climate characteristics, we found evidence of extensive spatial overlap between all species pairs and varying degrees of temporal overlap depending on species pairs and season. Collared peccaries and wild pigs displayed moderate temporal overlap across all seasons. Collared peccaries appeared to alter fall activity in the presence of wild pigs to be active earlier in the morning and less active during the day. Collared peccaries and warthogs had low-to-moderate temporal overlap (low in fall, winter; moderate in spring). Wild pigs and warthogs had low temporal overlap (fall, spring) and wild pigs appeared to alter activity in the presence of warthogs (fall), becoming less active during the day during peak warthog activity. Overall, our results suggest that peccary, wild pig, and warthog interactions and activity are dynamic and vary seasonally according to the ecology and preferred environmental conditions of each species. Given the potential for interspecific competition and disease transmission with Collared Peccary and other native wildlife, resource partitioning between wild pigs and warthogs needs to be further examined to aid in effective management strategies.

Kupferman, Caitlin A. (ORCID:0009000953554860)↗

Comparison of Different Variants of the U.S. Army Occupational Physical Assessment Test

The U.S. Army Occupational Physical Assessment Test (OPAT) is a pre-enlistment physical employment screening assessment developed to place recruits and soldiers into Military Occupational Specialties (MOSs) based on their physical capabilities in order to optimize performance and limit injury. The OPAT consists of the seated power throw (SPT), strength deadlift (SDL), standing long jump, and interval aerobic run. During the scientific validation of the OPAT, two variants of the SPT and two variants of the SDL were used. Although the OPAT was validated using both variants for each test, U.S. Army scientists and policymakers have received queries regarding how these variants compare to each other. Therefore, the purpose of this study was to compare different variants of the SPT and SDL. Thirty-two participants (14 male and 18 female) between the ages of 18 and 42 years visited the laboratory on one occasion and performed two variants of the SPT (seated on the ground [the current OPAT standard] versus seated in a chair with a 35 cm seat height) and two variants of the SDL (using a hex-bar [the current OPAT standard] versus using paired dumbbells). Testing order for the different variants was randomized. The protocol was approved by the U.S. Army Medical Research and Development Command Institutional Review Board. Performing the SPT from a chair significantly (P < .05) increased performance when compared to performing the SPT from the ground (5.4 ± 1.3 m versus 5.0 ± 1.4 m, respectively). Values for the two SPT variants were correlated (tau = 0.90). Performing the SDL using the hex-bar significantly increased the maximal weight lifted when compared to performing the SDL using paired dumbbells (86.9 ± 18.4 kg versus 83.1 ± 18.0 kg, respectively). Values for the two SDL variants were correlated (tau = 0.83). Performing different variants of the SPT and SDL influenced the resulting score. Although these findings do not alter the administration or scoring of the OPAT, they do provide a valuable reference in the event of future inquiries regarding the development of the OPAT.

General & Internal Medicine↗

The Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: exploring the halo occupation distribution model for emission line galaxies

We study the modelling of the halo occupation distribution (HOD) for the eBOSS DR16 emission line galaxies (ELGs). Motivated by previous theoretical and observational studies, we consider different physical effects that can change how ELGs populate haloes. We explore the shape of the average HOD, the fraction of satellite galaxies, their probability distribution function (PDF), and their density and velocity profiles. Our baseline HOD shape was fitted to a semi-analytical model of galaxy formation and evolution, with a decaying occupation of central ELGs at high halo masses. We consider Poisson and sub/super-Poissonian PDFs for satellite assignment. We model both Navarro–Frenk–White and particle profiles for satellite positions, also allowing for decreased concentrations. We model velocities with the virial theorem and particle velocity distributions. Additionally, we introduce a velocity bias and a net infall velocity. We study how these choices impact the clustering statistics while keeping the number density and bias fixed to that from eBOSS ELGs. The projected correlation function, w p , captures most of the effects from the PDF and satellites profile. The quadrupole, ξ 2 , captures most of the effects coming from the velocity profile. We find that the impact of the mean HOD shape is subdominant relative to the rest of choices. Here, we fit the clustering of the eBOSS DR16 ELG data under different combinations of the above assumptions. The catalogues presented here have been analysed in companion papers, showing that eBOSS RSD+BAO measurements are insensitive to the details of galaxy physics considered here. These catalogues are made publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding Ethiopian Abodes: Towards Classifying Buildings by Occupancy Type Using Footprint Morphology

Building occupancy classification plays a crucial role in urban planning, disaster management, and population modeling. Traditional methods often require extensive field surveys or detailed datasets, which can be time-consuming, expensive, and may yield incomplete or erroneous data. In this paper, we present a novel approach for classifying buildings as residential or non-residential using only building footprint data. By extracting geometric shape derivatives that characterize building morphology, we developed a high-accuracy classification model employing a combination of unsupervised and supervised learning methods. We utilized open-source data from Open Street Map, aggregating it to create binary labels for buildings based on their respective human use type. Our approach demonstrates the potential for scalability without the need for additional data sources other than building footprints and labels, offering a more efficient solution for building occupancy classification.

Adams, Daniel↗

OpenStudio Occupant-centric KPIs Reporting Measure v1.0

This is an OpenStudio measure that calculates and reports the occupant-centric key performance indicators (KPIs) for evaluating building energy performance from occupant-centric perspectives. The measure automatically calculate the KPIs in the following categories: (1) visual & lighting, (2) thermal (3) air quality, and (4) others.

Hong, Tianzhen↗