Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The DESI One-Percent survey: exploring the Halo Occupation Distribution of Emission Line Galaxies with AbacusSummit simulations

The One-Percent survey of the Dark Energy Spectroscopic Instrument collected ~ 270k emission line galaxies (ELGs) at 0.8 < z < 1.6. The high completeness of the sample allowed the clustering to be measured down to scales never probed before, 0.04 Mpc/h in rp for the projected 2-point correlation function (2PCF) and 0.17 Mpc/h in galaxy pair separation s for the 2PCF monopole and quadrupole. The most striking feature of the measurements is a strong signal at the smallest scales, below 0.2 Mpc/h in rp and 1 Mpc/h in s. We analyse these data in the halo occupation distribution framework. We consider different distributions for central galaxies, a standard power law for satellites with no condition on the presence of a central galaxy and explore several extensions of these models. For all considered models, the mean halo mass of the sample is found to be log10 $\langle$Mh$\rangle$ ~ 11.9. We obtain a satellite mean occupation function which agrees with physically motivated ELG models only if we introduce central-satellite conformity, meaning that the satellite occupation is conditioned by the presence of central galaxies of the same type. To achieve in addition a good modelling of the clustering between 0.1 and 1 Mpc/h in rp, we allow for ELG positioning outside of the halo virial radius and find 0.5% of ELGs residing in the outskirts of halos. Furthermore, the satellite velocity dispersion inside halos is found to be ~ 30% larger than that of the halo dark matter particles. These are the main findings of our work. Here we investigate assembly bias as a function of halo concentration, local density or local density anisotropies and observe no significant change in our results. We split the data sample in two redshift bins and report no significant evolution with redshift. Lastly, changing the cosmology in the modelling impacts only slightly our results.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of high-dose gamma-ray irradiation on electrical characteristics of N-polar and Ga-polar GaN p–n diodes

We investigate the impact of high-dose gamma-ray irradiation on the electrical performance of Ga-polar and N-polar GaN-based p-n diodes grown by metalorganic chemical vapor deposition. We compare the current density-voltage (J-V), capacitance-voltage (C-V), and circular transfer length method (CTLM) characteristics of the p-n diodes fabricated on Ga-polar and N-polar orientations before and after irradiation. The relative turn-on voltage increases for the Ga-polar diodes with increasing irradiation dose, while it increases initially and then starts to decrease for the N-polar diodes. The p-contact total resistance increases for Ga-polar and decreases for N-polar samples, which we attribute to the formation of point defects and additional Mg activation after irradiation. The J-V characteristics of most of the tested diodes recovered over time, suggesting the changes in the J-V characteristics are temporary and potentially due to metastable occupancy of traps after irradiation. X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL) measurements reveal the existence of different types of initial defects and surface electronic states on Ga-polar and N-polar samples. Gallium vacancies (V Ga ) are dominant defects in Ga-polar samples, while nitrogen vacancies (V N ) are dominant in N-polar samples. The presence of a higher concentration of surface states on Ga-polar surfaces compared to N-polar was confirmed by calculating the band bending and the corresponding screening effect due to opposite polarization bound charge and ionized acceptors at the surface. The difference in surface stoichiometry in these two orientations is responsible for the different behavior in electrical characteristics after gamma-ray interactions.

36 MATERIALS SCIENCE↗

In-beam γ -ray spectroscopy of negative-parity states of 37 K populated in dissipative reactions

In-beam γ-ray spectroscopy was used to study excited states of the neutron-deficient nucleus 37 K populated in fast-beam inelastic-scattering and proton-removal reactions at high-momentum loss. New γ-ray transitions and γγ coincidence relationships were established using the γ-ray tracking array GRETINA. The extension of the level scheme up to the first (13/2 – ) state highlights the potential of this recently demonstrated population pathway for studies of isospin symmetry involving mirror-energy differences. Furthermore, the nature of the newly identified states is discussed in comparison to shell-model calculations with the FSU cross-shell effective interaction. The calculated occupation numbers of individual orbitals are shown to offer a consistent explanation of the measured mirror-energy differences between 37 K and 37 Ar.

20 ≤ A ≤ 38↗

A Nonparametric Method for the Inference of Halo Occupation Distributions

The galaxy–halo connection traces processes by which galaxies form and evolve. The halo occupation distribution (HOD) describes the relationship between galaxies and their host dark matter haloes. Measurements of the galaxy two-point correlation function (2PCF) allow us to extract information about the HODs of observed galaxy samples. Several parametric HOD models have been proposed in the literature, but the choice of parameterization restricts the space of possible HODs. To resolve this issue, we introduce a nonparametric HOD fitting method in which we train an emulator to learn the mappings among the galaxy 2PCF, physical properties used to select galaxy samples, and the HOD, all obtained from simulated past light cones constructed with the Santa Cruz semianalytic model. Implementing this emulator within a likelihood analysis framework, we derive constraints on the HOD of a galaxy sample when provided with a measurement of its 2PCF. Using the emulator to accelerate likelihood evaluations, we test the nonparametric HOD approach on a set of 2PCFs for mock galaxy samples drawn from the TNG100-1 simulation and selected above threshold values of stellar mass and star formation rate. Our framework is able to recover TNG100-1 HODs within 0.2 dex. We use the TNG100-1 mocks to tune the reported uncertainties to estimate those expected in the analysis of observations. Comparing to parametric HOD modelling routines applied to the same mock galaxy samples, our approach consistently infers the HOD with comparable or greater precision and accuracy.

Kennedy, Jacob [Rutgers Univ., Piscataway, NJ (Uni↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

An Anomalous Electron Configuration Among 3d Transition Metal Atoms

Physical properties of materials are mainly determined by valence electron configurations, where different valence shells would induce divergent phenomena. In compounds containing Sc 2+ , 3d electron occupancy is expected, same as other transition metal atoms like Ti 3+ . But this situation still awaits experimental verification. In this work, we selected ScS to measure the valence electron density and orbital population of Sc2+ through delicate quantitative convergent-beam electron diffraction. Though the [Ar]3d 1 configuration is confirmed in ionic Sc 2+ , the unintuitive occupation of 4s orbital is concluded with the absence of 3d orbital features around Sc-atom sites and nearly bare population of t2g orbital. It should be the first time to report this special electron configuration in a transition metal compound, in which 4s rather than 3d orbital is preferred. Our findings reveal the distinct behavior of Sc, and probable ways to modulate material properties by controlling electron orbitals.

36 MATERIALS SCIENCE↗

mRNA SARS-CoV-2 Immunization Confers Robust Antibody Response in Occupational Healthcare Workers and Fosters Workplace Safety

Immunization against Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) is a major step in protecting the healthcare worker beyond standard pandemic precautions and infection control measures. Healthcare workers (HCW) are at high risk for SARS-CoV-2 exposure and infection placing burden on the workplace. Hence, reducing SARS-CoV-2 infection of HCWs serves multiple goals in the occupational health arena. These include protecting the health and safety of the HCW as well as reducing transmission of Coronavirus Disease 2019 (COVID-19) in the clinic and the larger workplace it serves. Furthermore, when HCWs demonstrate appropriate pandemic precautions and health practices, they serve as strategic models for other workers. Here, this modeling represents leadership which can inspire optimism and hope in a workforce beleaguered by the pandemic.

60 APPLIED LIFE SCIENCES↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studying Response to Light in Offices: A Literature Review and Pilot Study

Researchers have been exploring the influence of light on health in office settings for over two decades; however, a greater understanding of physiological responses and technology advancements are shifting the way researchers study the influence of light in realistic environments. New technologies paired with Ecological Momentary Assessments (EMAs) administered via smartphones provide ways to collect information about individual light exposure and occupant response throughout the day. The study aims to document occupant response to tunable lighting in a real office environment, including potential beneficial or adverse health and well-being effects. Twenty-three office employees agreed to participate in a twelve-week study examining occupant response to two lighting conditions (static vs. dynamic). No significant differences were observed for any of the measures, highlighting the importance and complexity of in-situ studies conducted in realistic environments. While prior office studies have shown a significant influence on daytime sleepiness and sleep quality, research has not shown mood or stress to be significantly impacted by lighting conditions. Correlation analyses regarding lighting satisfaction, environmental satisfaction, and visual comfort demonstrate a significant relationship between certain items that may inform future studies. Further, the high correlation means it is reasonable to assume that many environmental factors in offices can influence occupant behavior and well-being.

60 APPLIED LIFE SCIENCES↗

The DESI One-percent Survey: Evidence for Assembly Bias from Low-redshift Counts-in-cylinders Measurements

Abstract We explore the galaxy-halo connection information that is available in low-redshift samples from the early data release of the Dark Energy Spectroscopic Instrument (DESI). We model the halo occupation distribution (HOD) from z = 0.1 to 0.3 using Survey Validation 3 (SV3; a.k.a., the One-Percent Survey) data of the DESI Bright Galaxy Survey. In addition to more commonly used metrics, we incorporate counts-in-cylinders (CiC) measurements, which drastically tighten HOD constraints. Our analysis is aided by the Python package, galtab , which enables the rapid, precise prediction of CiC for any HOD model available in halotools . This methodology allows our Markov chains to converge with much fewer trial points, and enables even more drastic speedups due to its GPU portability. Our HOD fits constrain characteristic halo masses tightly and provide statistical evidence for assembly bias, especially at lower luminosity thresholds: the HOD of central galaxies in z ∼ 0.15 samples with limiting absolute magnitude M r < −20.0 and M r < −20.5 samples is positively correlated with halo concentration with a significance of 99.9% and 99.5%, respectively. Our models also favor positive central assembly bias for the brighter M r < −21.0 sample at z ∼ 0.25 (94.8% significance), but there is no significant evidence for assembly bias with the same luminosity threshold at z ∼ 0.15. We provide our constraints for each threshold sample’s characteristic halo masses, assembly bias, and other HOD parameters. These constraints are expected to be significantly tightened with future DESI data, which will span an area 100 times larger than that of SV3.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmological inference from an emulator based halo model. II. Joint analysis of galaxy-galaxy weak lensing and galaxy clustering from HSC-Y1 and SDSS

Here, we present high-fidelity cosmology results from a blinded joint analysis of galaxy-galaxy weak lensing (ΔΣ) and projected galaxy clustering (w p ) measured from the Hyper Suprime-Cam Year-1 (HSC-Y1) data and spectroscopic Sloan Digital Sky Survey (SDSS) galaxy catalogs in the redshift range 0.15 < z < 0.7. We define luminosity-limited samples of SDSS galaxies to serve as the tracers of w p in three spectroscopic redshift bins, and as the lens samples for ΔΣ. For the ΔΣ measurements, we select a single sample of 4×10 6 source galaxies over 140 deg 2 from HSC-Y1 with photometric redshifts (photo z) greater than 0.75, enabling a better handle of photo- z errors by comparing the ΔΣ amplitudes for the three lens redshift bins. The deep, high-quality HSC-Y1 data enable significant detections of the ΔΣ signals, with integrated signal-to-noise ratio S/N ~ 15 in the range 3 ≤ R/[h –1 Mpc] ≤ 30 for the three lens samples, despite the small area coverage. For cosmological parameter inference, we use an input galaxy-halo connection model built on the dark emulator package (which uses an ensemble set of high-resolution N-body simulations and enables fast, accurate computation of the clustering observables) with a halo occupation distribution that includes nuisance parameters to marginalize over modeling uncertainties. We model the ΔΣ and wp measurements on scales from R≃3 and 2h –1 Mpc , respectively, up to 30 h –1 Mpc (therefore excluding the baryon acoustic oscillations information) assuming a flat Λ CDM cosmology, marginalizing over about 20 nuisance parameters and demonstrating the robustness of our results to them. With various tests using mock catalogs described in Miyatake et al. [preceding paper, Phys. Rev. D 106, 083519 (2022)], we show that any bias in the clustering amplitude S 8 ≡ σ 8 (Ω m /0.3) 0.5 due to uncertainties in the galaxy-halo connection is less than ~ 50 % of the statistical uncertainty of S 8 , unless the assembly biaseffect is unexpectedly large. Our best-fit models have S 8 = 0.795$_{-0.042}^{+0.049}$ (mode and 68% credible interval) for the flat Λ CDM model; we find tighter constraints on the quantity S 8 (α = 0.17)≡σ 8 (Ω m /0.3) 0.17 = 0.745$_{-0.031}^{+0.039}$.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Optimizing Layered Control Strategies for Reducing Exposure to SARS-CoV-2

While there is growing understanding of the predominance of the airborne mode of transmission of the SARS-CoV-2 virus, there is a lack of guidance on how to build an effective system of controls to mitigate transmission in enclosed spaces. Such a system integrates multiple hazard-specific control measures to both eliminate or replace a hazard, and safeguard individuals against potential exposure and infection. Controls are defined by the US Occupational Safety and Health Association (OSHA) as the use of engineering methods to reduce the level of hazard inside a confined space. The Hierarchy of Controls provides a framework through which a system of controls can be examined; identifying those which directly remove or replace a hazard as the most effective, and individual behavioral measures (e.g., masking or shielding) as least effective. Use of such a framework to quantify control effectiveness might allow for the promotion of spaces as meeting a certain threshold of safety, likely adding to the confidence of space users resulting in increases in various metrics such as sales, visits, or likes.

99 GENERAL AND MISCELLANEOUS↗

Limitations to the ‘basic’ HOD model and beyond

ABSTRACT We use the IllustrisTNG cosmological, hydrodynamical simulations to test fundamental assumptions of the mass-based halo occupation distribution (HOD) approach to modelling the galaxy–halo connection. By comparing the clustering of galaxies measured in the 300 Mpc TNG box (TNG300) with that predicted by the standard (basic) HOD model, we find that, on average, the ‘basic’ HOD model underpredicts the real-space correlation function in the TNG300 box by ∼15 per cent on scales of $1 \,\,\lt\,\, r \,\,\lt\,\, 20 \ {\rm Mpc}\, h^{-1}$, which is well beyond the target precision demanded of next-generation galaxy redshift surveys. We perform several tests to establish the robustness of our findings to systematic effects, including the effect of finite box size and the choice of halo finder. In our exploration of ‘secondary’ parameters with which to augment the ‘basic’ HOD, we find that the local environment of the halo, the velocity dispersion anisotropy, β, and the product of the half-mass radius and the velocity dispersion, σ2Rhalfmass, are the three most effective measures of assembly bias that help reconcile the ‘basic’ HOD-predicted clustering with that in TNG300. In addition, we test other halo properties such as halo spin, formation epoch, and halo concentration. We also find that at fixed halo mass, galaxies in one type of environment cluster differently from galaxies in another. We demonstrate that a more complete model of the galaxy–halo connection can be constructed if we combine both mass and local environment information about the halo.

42 ENGINEERING↗

Equation of State and Thermometry of the 2D SU ( N ) Fermi-Hubbard Model

We characterize the equation of state (EoS) of the SU ( N > 2 ) Fermi-Hubbard Model (FHM) in a two-dimensional single-layer square optical lattice. We probe the density and the site occupation probabilities as functions of interaction strength and temperature for N = 3 , 4, and 6. Our measurements are used as a benchmark for state-of-the-art numerical methods including determinantal quantum Monte Carlo and numerical linked cluster expansion. By probing the density fluctuations, we compare temperatures determined in a model-independent way by fitting measurements to numerically calculated EoS results, making this a particularly interesting new step in the exploration and characterization of the SU ( N ) FHM. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth, characterization, and Chern insulator state in MnBi 2⁢ Te 4 via the chemical vapor transport method

As the first intrinsic antiferromagnetic topological insulator, MnBi 2 Te 4 has provided a platform to investigate the interplay of band topology and magnetism as well as the emergent phenomena arising from such an interplay. Here we report the chemical-vapor-transport (CVT) growth and characterization of MnBi 2 Te 4 , as well as the observation of the field-induced quantized Hall conductance in 6-layer devices. Through comparative studies between our CVT-grown and flux-grown MnBi 2 Te 4 via magnetic, transport, scanning tunneling microscopy, and angle-resolved photoemission spectroscopy measurements, we find that CVT-grown MnBi 2 Te 4 is marked with higher Mn occupancy on the Mn site, slightly higher Mn Bi antisites, smaller carrier concentration, and a Fermi level closer to the Dirac point. Furthermore, a 6-layer device made from the CVT-grown sample shows by far the highest mobility of 2500 cm 2 V s in MnBi 2 Te 4 devices with the quantized Hall conductance appearing at 1.8 K and 8 T. Furthermore, our study provides a route to obtain high-quality single crystals of MnBi 2 Te 4 that are promising to make superior devices and realize emergent phenomena, such as the layer Hall effect and quantized anomalous Hall effect, etc.

36 MATERIALS SCIENCE↗