Evaluation of Cation Migration in Lanthanum Strontium Cobalt Ferrite Solid Oxide Fuel Cell Cathodes via In-Operando X-ray Diffraction

Anode-supported SOFC button cells with LSCF-6428 cathodes were operated at various temperatures under constant current conditions for hundreds of hours in dry or humid (~3% water) cathode air while continuously collecting 1 hour XRD scans throughout the test duration. Additionally, one cell in dry air was held at OCV, and 12% CO2 was added to the humid air for another cell. Long cumulative XRD count times allowed minor phases in concentrations of less than 0.1 wt% to be identified. In humid air, cell performance increased during the first couple of hundred hours. XRD measured a gradual shift of Fe-rich Fe,Co spinel peaks to lower angles while post-mortem SEM discovered nano-nodules on the LSCF surfaces. When 12% CO2 was added to humid air, performance degradation was observed after the initial conditioning response, unlike in tests without CO2, which were stable after conditioning. XRD also measured a shift in the peaks of the major LSCF phase in the test with CO2 indicative of some degree of gradual decomposition. Cells tested at constant current in dry air exhibited fast initial degradation that decelerated over time, while the cell held at OCV maintained a stable voltage. XRD of the cathodes held at OCV at 750 °C and operated at constant current at 700 °C in dry air measured a slower shift of the Fe-rich spinel peaks to lower angles than was seen in tests in humid air, along with a shift in the peaks of a Co-rich Fe,Co spinel to higher angles. Post-mortem SEM of cells exposed to dry air discovered smaller nano-nodules on the LSCF surfaces than had been present in cells tested in humid air. Cells tested at constant current in dry air at 750 °C and 800 °C did not exhibit any gradual changes in the XRD patterns nor were nano-nodules discovered.

Hardy, John S.↗

Assessment of the Distributed Generation Market Potential for Solid Oxide Fuel Cells

The focus of the solid oxide fuel cell (SOFC) program at the National Energy Technology Laboratory (NETL) is to develop low-cost, highly efficient solid oxide fuel cell power systems that are capable of simultaneously producing electric power with carbon capture when integrated with gasification. To accomplish this goal, research and demonstration projects are being undertaken to enhance the reliability and the robustness of the SOFC system. NETL’s SOFC technology roadmap is focused on developing and demonstrating progressively larger megawatt electric (MWe) class natural-gas-based systems to validate and advance SOFC technology for natural gas and gasified coal-based utility scale power generation. As the SOFC technology advances from its current state to utility scale, it is possible that MWe class systems could penetrate the distributed generation (DG) market segment. If the SOFC technology were to penetrate the DG market, this would have the added benefit of lowering system costs by establishing operational experience and a manufacturing base. This report analyzed the strengths of the SOFC system in conjunction with relevant DG market segments in the United States (U.S.) and determined that natural gas compressor stations, grid strengthening, and data centers were potential early market-entry opportunities. These three DG market segments are projected to demand two gigawatts (GWs) of additional power between now and 2018 and 25 GWs between now and 2040. Historical experiences with related technology, including effects of increased production capacity on capital costs, were used to evaluate the market penetration necessary for a cost competitive DG SOFC system. This analysis showed that the DG SOFC system becomes cost competitive with other fossil-fuel based DG technologies after 25 MWe of installed capacity, around 2025, based on the demonstration of the first SOFC DG unit in the year 2020. The SOFC DG application validates and enables the technology for utility scale systems with carbon capture and forms an essential first phase of the NETL technology development roadmap, which is based on the vision to develop a commercially competitive utility-scale system with carbon capture.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of SmBaCuCoO{sub 5+{delta}} double-perovskite as cathode for proton-conducting solid oxide fuel cells

SmBaCuCoO{sub 5+{delta}}, a double-perovskite oxide, was synthesized by the modified Pechini method and developed as cathode material for proton-conducting solid oxide fuel cells. The SmBaCuCoO{sub 5+{delta}} powders calcined at 800 {sup o}C, show the double-perovskite structure in powder XRD pattern. SmBaCuCoO{sub 5+{delta}} has a more suitable thermal expansion coefficient than SmBaCo{sub 2}O{sub 5+{delta}} for BaCe{sub 0.7}Zr{sub 0.1}Y{sub 0.2}O{sub 3-{delta}} electrolyte-based solid oxide fuel cells. The single cell was tested with humidified hydrogen ({approx}3% H{sub 2}O) as the fuel and static air as the oxidant. The performance of the cell was characterized by DC Electronic Load and AC impedance spectroscopy. The peak power densities reached 355-86 mW cm{sup -2} in the range of 700-550 {sup o}C and the interfacial polarization resistance decreased with increasing operation temperature, from 3.1 {Omega} cm{sup 2} at 550 {sup o}C to 0.22 {Omega} cm{sup 2} at 700 {sup o}C. The high power density and low polarization demonstrate that SmBaCuCoO{sub 5+{delta}} is a potential candidate for proton-conducting solid oxide fuel cells.

36 MATERIALS SCIENCE↗

Recent Advances in Metallic Interconnects for Solid Oxide Fuel Cells

With the steady reduction in solid oxide fuel cell (SOFC) operating temperatures into a range of 650-800C, cost effective metallic materials, in particular high temperature oxidation resistant alloys, have become promising candidates, in place of ceramic counterparts, for construction of interconnects in SOFC stacks. For a lifetime of thousands of hours, the alloys must demonstrate excellent surface, structural and electrical stability, and compatibility with other components in SOFC stacks in a very challenging environment. The paper provides a comprehensive critical review of metallic interconnects for SOFCs with a focus on recent progress in materials development, as well as advances in understanding materials degradation and interfacial phenomena under the SOFC operating conditions. It also attempts to provide guiding principles for development of optimized, cost-effective metallic interconnect materials that can demonstrate satisfactory life-time stability and performance.

30 DIRECT ENERGY CONVERSION↗

Electrode Design for Low Temperature Direct-Hydrocarbon Solid Oxide Fuel Cells

In certain embodiments of the present disclosure, a solid oxide fuel cell is described. The solid oxide fuel cell includes a hierarchically porous cathode support having an impregnated cobaltite cathode deposited thereon, an electrolyte, and an anode support. The anode support includes hydrocarbon oxidation catalyst deposited thereon, wherein the cathode support, electrolyte, and anode support are joined together and wherein the solid oxide fuel cell operates a temperature of 600.degree. C. or less.

Chen, Fanglin↗

Electrode design for low temperature direct-hydrocarbon solid oxide fuel cells

In certain embodiments of the present disclosure, a solid oxide fuel cell is described. The solid oxide fuel cell includes a hierarchically porous cathode support having an impregnated cobaltite cathode deposited thereon, an electrolyte, and an anode support. The anode support includes hydrocarbon oxidation catalyst deposited thereon, wherein the cathode support, electrolyte, and anode support are joined together and wherein the solid oxide fuel cell operates a temperature of 600.degree. C. or less.

30 DIRECT ENERGY CONVERSION↗

Scaleup and manufacturability of symmetric-structured metal-supported solid oxide fuel cells

Metal-supported solid oxide fuel cells with symmetric architecture, having metal supports on both sides of the cell, are scaled up from button cell size to large 50 cm 2 active area cell size. The cells remain flat after sintering assisted by the symmetric structure. Equivalent performance is achieved for button cells and large cells, and thermal cycling and redox cycling tolerance are demonstrated for the large cells. The catalyst infiltration process is improved to enable high-throughput manufacturing. The cumbersome lab-scale molten nitrate infiltration process is replaced with a room-temperature process in which a shelf-stable aqueous solution of nitrate salts is applied to the cell by spraying, painting, or other scalable techniques. Here, a fast-ramp thermal conversion of the nitrate salts to the final oxide catalyst composition is implemented, allowing many infiltration cycles to be accomplished in a single work shift. Increasing the number of infiltration cycles from 5 to 10 led to an increase in peak power density from approximately 0.3 to 0.52 W cm -2 .

25 ENERGY STORAGE↗

Reliability of Materials and Components for Solid Oxide Fuel Cells

Planar stack solid-oxide fuel cells (SOFCs) require seals that must operate reliably under demanding conditions for lifetimes of 40000 hours. This includes temperature fluctuations between 800°C and RT during on and off cycles, thermal stresses, oxidizing environments and chemical degradation to name a few. This comprehensive report provides results from long term testing of two commercially available multicomponent barium alkali silicate glasses: SCN and G6, chosen as sealing candidates. In this scope, the glass seals were deposited on YSZ and Al 2 O 3 substrates simulating electrolytes (Zrbased) and coatings (both zirconia and Al 2 O 3 ). The seal-substrate couples were subjected to 800°C under air and steam+H 2 +N 2 environments up to 40000 hours to test their integrity under real operating conditions. Extensive studies on the effects of exposure have been conducted over the span of testing at various time intervals. Within the context of characterization, mechanical properties such as density, roughness, thermal expansion and glass transition, viscosity and wettability behavior; and microstructural properties such as glass chemistries, defect formation (cracks and pores), phase transformations (devitrification) and glass-interface reactions are investigated. Results and discussions are provided with a focus on the degradation of the properties over long term interrupted testing.

30 DIRECT ENERGY CONVERSION↗

Fe-substituted SrTiO 3-δ -Ce 0.9 Gd 0.1 O 2 composite anodes for solid oxide fuel cells

A new composite solid oxide fuel cell anode material, SrTi 1-x Fe x O 3-δ mixed with Gd-doped ceria, was tested in La 0.9 Sr 0.1 Ga 0.8 Mg 0.2 O 3-δ electrolyte-supported cells with La 0.4 Ce 0.6 O 2 barrier layers and La 0.6 Sr 0.4 Fe 0.8 Co 0.2 O 3 cathodes. The x = 0.7 composition had an anode polarization resistance of 0.17 Ω cm 2 , at 800 °C in humidified H 2 , much lower than the value 0.39 Ω cm 2 measured for x = 0.4 and 3.14 Ω cm 2 for x = 0. The reduced polarization resistance correlated with increased oxygen non-stoichiometry δ, which suggests that it may be related to increased ionic conductivity. Electrochemical impedance spectroscopy (EIS) measurements at 800 °C on the x = 0.7 anode cell showed a main response centered at ~1 Hz that increased with decreasing hydrogen partial pressure. The maximum power density observed was for the x = 0.7 cell – 337 mW cm -2 at 800 °C in air and humidified hydrogen – and was limited mainly by the thick electrolyte.

Cho, Sungmee↗

Metal-Supported Solid Oxide Fuel Cells for Natural Gas

Solid oxide fuel cells (SOFCs) are high temperature energy conversion devices that produce electricity efficiently and sustainably. High operating temperatures required for SOFC function endow these devices with many advantages including fuel flexibility and high conversion efficiencies. Fuel flexibility, in particular, distinguishes SOFCs from other types of fuel cells that operate with clean H 2 only, and enables operation with natural gas (NG). LBNL has developed metal supported SOFCs (MS-SOFCs) with unique symmetrical architecture that offer several advantages over state of the art (SoA) ceramic SOFC models including inexpensive materials, rapid start up capability, increased mechanical strength and high tolerance to thermal cycling, Fig 1. These advantages make LBNL MS-SOFCs uniquely suited for fast start-up, portable, and mobile backup generator applications. Specifically motivating this work was a scenario of backup generators fueled by pipeline natural gas delivered from SoCalGas in the event of an electric grid shut down. This project investigates the feasibility of using MS-SOFCs with pre-reformed natural gas as well as direct on-cell reforming of simulated natural gas both with and without sulfur.