Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance Modelling and Yearlong Outdoor Degradation Analysis of a GaAs//Si Tandem Module

Silicon-based tandem photovoltaic cells and modules are forecasted to enter mass production around the year 2026. Previous research efforts on tandem photovoltaic technology have focused heavily on increasing cell efficiencies. However, for successful large-scale deployment of tandem modules, reliability and long-term durability will be equally important. Outdoor performance data beyond the one-year mark enable sophisticated degradation analysis and help build confidence in the reliability and durability of this new technology.

degradation rate↗

An ensemble data assimilation modeling system for operational outdoor microalgae growth forecasting

Microalgae have received increasing attention as a potential feedstock for biofuel or biobased products. Forecasting the microalgae growth is beneficial for managers in planning pond operations and harvesting decisions. This study proposed a biomass forecasting system comprised of the Huesemann Algae Biomass Growth Model (BGM), the Modular Aquatic Simulation System in Two Dimensions (MASS2), ensemble data assimilation (DA), and numerical weather prediction Global Ensemble Forecast System (GEFS) ensemble meteorological forecasts. The novelty of this study is to seek the use of ensemble DA to improve both BGM and MASS2 model initial conditions with the assimilation of biomass and water temperature measurements and consequently improve short-term biomass forecasting skills. This study introduces the theory behind the proposed integrated biomass forecasting system, with an application undertaken in pseudo-real-time in three outdoor ponds cultured with Chlorella sorokiniana in Delhi, California, United States. Results from all three case studies demonstrate that the biomass forecasting system improved the short-term (i.e., 7-day) biomass forecasting skills by about 60% on average, comparing to forecasts without using the ensemble DA method. Given the satisfactory performances achieved in this study, it is probable that the integrated BGM-MASS2-DA forecasting system can be used operationally to inform managers in making pond operation and harvesting planning decisions.

59 BASIC BIOLOGICAL SCIENCES↗

Survival and behavior of Mojave desert tortoises head-started with and without outdoor rearing

Mojave desert tortoise (Gopherus agassizii) populations in some regions have declined by >50% since 2004, prompting the need for more research on ways to recover populations. One possible recovery tool is head-starting (i.e., the act of protecting and raising juvenile tortoises to sizes that increase survival upon release); however, head-starting can have high start-up and maintenance costs that can limit its feasibility. Strategies that reduce cost and rearing duration may foster broader and more effective use. We released and radio-tracked 60 juvenile tortoises in the Mojave National Preserve in California, USA, that had been reared under 2 treatments: those reared 1 year indoors after hatching, then 1 year outdoors (combo) and those reared just 1 year indoors (indoor-only). We tested whether indoor-only rearing alone could be a more efficient means of producing robust head-started tortoises. We examined the behavior, movement, and survival of tortoises after release into the wild from 2020 to 2021 to determine whether these outcomes differed between husbandry treatments. Combo tortoises tended to perform settling behaviors (mean ± 1 SE days to building first burrow = 6.7 ± 0.8, entering dormancy = 23.3 ± 2.1, and emerging from dormancy = 189.6 ± 4.4) earlier than indoor-only tortoises (7.4 ± 0.9, 31.5 ± 2.6, and 193.9 ± 5.9, respectively), but this difference was not significant, suggesting the rearing method did not greatly alter settling behavior. Indoor-only tortoises dispersed at least twice as far from their release site (156.2 ± 26.3 m compared with 77.3 ± 20.6 m for combo tortoises), had larger mean use areas (3.7 ± 0.1 ha compared with 2.8 ± 0.3 ha for combo tortoises for 95% Brownian bridge movement model estimates), and greater variability in their movements than combo tortoises (daily average step length post-emergence: 4.3 ± 0.2 m compared with 2.8 ± 0.1 m for combo tortoises). Despite differences in their movements, indoor-only and combo tortoises had similar survival rates over the study, 51% versus 42%, respectively, during a period of extreme drought in 2021. The similarity in survival between groups gives head-starting practitioners freedom in their rearing methods. The indoor-only group had lower site fidelity, which should be considered when this is an undesirable trait for released tortoises.

60 APPLIED LIFE SCIENCES↗

Association of Vampirovibrio chlorellavorus with decline and death of Chlorella sorokiniana in outdoor reactors

The outdoor ARID raceway was established for optimizing the cultivation of microalgae for biofuel production. During the summers of 2014 and 2015, discoloration was observed in cultures of Chlorella sorokiniana , which shifted from a vibrant green color to yellow, followed by cell clumping, decline in density, and rapid death, resulting in 40–60% reduced biomass production. To investigate, total DNA was purified from the raceway samples and subjected to polymerase chain reaction (PCR) amplification using degenerate primers that amplify the 16S rRNA gene of eubacteria. BLASTn analysis of the cloned amplicon sequences revealed the presence of the Gram-negative, predatory bacterium, Vampirovibrio chlorellavorus . Scanning electron microscopic examination showed an abundance of coccoid cells, 0.3–0.6 μm in diameter, some of which were attached to C. sorokiniana cells. PCR amplification indicated the presence of V. chlorellavorus in raceway vessels, water lines, connective tubing, and in early, scaled-up DOE1412 cultures used to inoculate the raceway. Based on PCR detection, the decontamination of the equipment and water line with "Wal-Clean" more effectively eliminated V. chlorellavorus and delayed the onset of attack, compared to the chlorine disinfectant, trichloromelamine (TCM). Total DNA was isolated from soil samples collected monthly from the nearby Rillito River during 2014–2015 and subjected to PCR amplification using primers designed to amplify the 16S rRNA and 18S rRNA gene of V. chlorellavorus and C. sorokiniana , respectively. Results indicated that V. chlorellavorus and Chlorella spp. were present in most of the riverbed samples nearly year round, suggesting a possible naturally occurring reservoir of the predatory bacterium.

59 BASIC BIOLOGICAL SCIENCES↗

Tracking Error Learning Control for Precise Mobile Robot Path Tracking in Outdoor Environment

This article presents a Tracking-Error Learning Control (TELC) algorithm for precise mobile robot path tracking in off-road terrain. In traditional tracking error-based control approaches, feedback and feedforward controllers are designed based on the nominal model which cannot capture the uncertainties, disturbances and changing working conditions so that they cannot ensure precise path tracking performance in the outdoor environment. In TELC algorithm, the feedforward control actions are updated by using the tracking error dynamics and the plant-model mismatch problem is thus discarded. Therefore, the feedforward controller gradually eliminates the feedback controller from the control of the system once the mobile robot has been ontrack. In addition to the proof of the stability, it is proven that the cost functions do not have local minima so that the coefficients in TELC algorithm guarantee that the global minimum is reached. The experimental results show that the TELC algorithm results in better path tracking performance than the traditional tracking error-based control method. The mobile robot controlled by TELC algorithm can track a target path precisely with less than 10 cm error in off-road terrain.

42 ENGINEERING↗

Soil sealing by algae: An alternative to plastic pond liners for outdoor algal cultivation

Commercial production of algal biofuels is currently limited by high capital costs, particularly costs of synthetic pond liners that minimize seepage of cultivation fluids, salts, and nutrients into the subsurface beneath outdoor algae cultivation facilities. Even some profitable nutraceutical companies bear the high costs of pond liners. However, studies of animal waste holding ponds and aquaculture facilities have shown that underlying soils can effectively “self-seal”, potentially eliminating the need for plastic liners. Here, we explored the potential for self-sealing with algae to provide an alternative to synthetic pond liners in unlined algae cultivation ponds. Laboratory-scale soil column experiments were used to investigate soil clogging by algae, a topic rarely discussed in the literature. Columns composed of fine sand, loamy sand, and loam soil displayed reductions in saturated hydraulic conductivity of the entire soil column of up to two orders of magnitude in response to infiltration by the alga Scenedesmus dimorphus suspended in algal culture nutrient solution at a density of 5 × 10 8 cells L –1 . Scanning electron microscope imaging showed a dense algal layer on the surface of each soil column, thickly coating mineral grains with algal material and filling pore spaces. The algal coating was absent in samples at >3 cm depth in the soil columns, and measurements of chlorophyll content also confirmed that algal cells were mostly confined to the soil surface. In this study, the application of an algal suspension contributed significantly to soil sealing. In conclusion, this new application of biological sealing technology should be studied further to determine its utility and durability as an alternative to plastic liners, perhaps in conjunction with soil compaction to achieve hydraulic conductivities beneath algal production ponds that are protective of groundwater quality.

59 BASIC BIOLOGICAL SCIENCES↗

Improved CO 2 utilization efficiency using membrane carbonation in outdoor raceways

Membrane carbonation, the delivery of CO 2 by diffusion through non-porous hollow fiber membranes, was successfully integrated into outdoor raceways (5.6 m 2 , 900 L) and operated continuously for up to 45 days. Biomass productivity associated with membrane carbonation was similar to using traditional sparging, but the average carbon utilization efficiencies for membrane carbonation was 3-fold higher than for sparging when 100% CO 2 was delivered to both systems. Here, when the pH setpoint was 8.5, growth on ammonium bicarbonate using membrane carbonation achieved a carbon utilization efficiency of 106 ± 45% due to uptake of some carbon from bicarbonate. Using nitrate as the N source had a 78 ± 55% carbon utilization efficiency, due to dissolved inorganic carbon accumulation as the medium alkalinity increased. Lowering the pH setpoint to 8.0 created a carbon-rich environment that decreased the carbon utilization efficiency to 51 ± 27% due to CO 2 off-gassing, but it still was 3-fold higher than with sparging.

54 ENVIRONMENTAL SCIENCES↗

A validated thermal and biological model for predicting algal productivity in large scale outdoor cultivation systems

Proper assessment of the sustainability of algal products requires an understanding of algal growth rate with regional and temporal resolution. This study developed a bulk growth model that utilizes geospatial data, reactor geometry inputs, and a maximum of six strain-specific parameters to predict algal productivity with temporal and regional resolution. The model requires local weather data to calculate the time-resolved culture temperature which is combined with a biological model based on maximum theoretical carbon fixation to predict the time-resolved algal concentration. Validation of the model against experimental data illustrates an average ac- curacy of 0.27% ± 5.32% when comparing algal concentration at harvest over 45 days of cultivation data for Galdieria sulphuraria 5587.1, and Galdieria sulphuraria Soos grown in photobioreactors (PBRs) in Mesa, AZ (33.4152° N, 111.8315° W). For open raceway ponds (ORPs), an accuracy of 0.9% ± 2.35% was achieved when comparing algal concentration at harvest over 50 days of cultivation data for Chlorella vulgaris, Desmodesmus intermedius, Nannochloropsis oceanica grown in Atlanta, GA (33.7490° N, 84.3880° W) and Mesa, AZ (33.4152° N, 111.8315° W). The validation trials spanned three seasons (winter, spring, and summer) to ensure model ac- curacy throughout the year, and concentration between harvests was modeled with hourly resolution. The validated model is used to assess the productivity at several case-study locations in the United States with Chlorella vulgaris, grown in open raceway ponds and Galdieria sulphuraria grown in vertical flat panel photo- bioreactors. In conclusion, the model has been published as an open-source tool, in an effort to increase the fidelity of future studies that rely on outdoor algae cultivation for feedstock production and allow for time resolved results for future techno-economic and life cycle assessments.

59 BASIC BIOLOGICAL SCIENCES↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy savings with outdoor temperature-based smart ventilation control strategies in advanced California homes

We simulated the energy performance of smart ventilation controls based on outdoor temperature in homes located in California climate regions, designed to comply with the 2016 Title 24, Part 6 California Energy Code prescriptive requirements. The smart controls shift ventilation rates in time, but ensure an annual occupant pollutant exposure equal to, or less than, what would be experienced in a home with a constant ventilation rate equal to the whole house target airflow in the ASHRAE Standard 62.2-2016. Annual simulations of previously developed prototype homes with validated ventilation models were conducted via co-simulation of EnergyPlus with CONTAM. Controller performance varied substantially by climate zone, airtightness and house prototype. Smart controls were generally ineffective in Climate Zone 1 (Arcata) due to its lack of a cooling season and low diurnal temperature swings. The most successful smart controls used parameters pre-calculated using an optimization routine. In order to better inform state energy policy, we also determined savings weighted by the amount of new home construction in each climate. The best controls averaged about one-third of ventilation-related energy savings that increased to about 48–55% when weighted. Annual average savings were about 650–700 kWh/year for the best controllers. The vast majority of site energy savings were for heating end-uses (>90% of total savings). Whole house ventilation rates increased between 0% and 42%, with typical increases in the 15–20% range. Finally, the best-performing control strategies shifted ventilation rates seasonally and modulated flows within each season. Peak concentrations during low ventilation times were kept below an exposure level of 3, well below the maximum of 5 required to avoid acute exposure issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential segregation and outdoor urban moist heat stress disparities in the United States

The combined impact of urbanization-induced warming and drying on large-scale heat stress disparities remains unknown, with multicity studies using satellite-derived land surface temperature as a proxy for these disparities. Here, using high-resolution urban-resolving numerical model simulations for 2014–2018, we find pervasive disparities in all-sky average maximum summertime air temperature and moist heat stress metrics across US cities, with higher outdoor heat stress exposure in poorer and primarily non-white census tracts. Ninety-four percent of the US urban population (228 million) live in cities where heat stress burdens the poor, with heat stress inequities between white and non-white populations strongly associated with residential segregation. Similarly, historically redlined neighborhoods show higher heat stress than their non-redlined counterparts, demonstrating how historical segregation relates to present-day environmental inequalities. Our results provide quantitative estimates of physiologically relevant heat stress disparities at the US national scale and highlight potential biases when using satellites as a proxy for these.

54 ENVIRONMENTAL SCIENCES↗

Lower Urban Humidity Moderates Outdoor Heat Stress

Abstract Surface temperature is often used to examine heat exposure in multi‐city studies and for informing urban heat mitigation efforts due to scarcity of urban air temperature measurements. Cities also have lower relative humidity, traditionally not accounted for in large‐scale observational urban heat risk assessments. Here, using crowdsourced measurements from over 40,000 weather stations in ≈600 urban clusters in Europe, we show the moderating effect of this urbanization‐induced humidity reduction on outdoor heat stress during the 2019 heatwave. We demonstrate that daytime differences in heat index between urban clusters and their surroundings are weak, and associations of this urban‐rural difference with background climate, generally examined from the surface temperature perspective, are diminished due to moisture feedbacks. We also examine the spatial variability of surface temperature, air temperature, and heat index within these clusters—relevant for detecting hotspots and potential disparities in heat exposure—and find that surface temperature is a poor proxy for the intra‐urban distribution of heat index during daytime. Finally, urban vegetation shows much weaker (∼1/6th as strong) associations with heat index than with surface temperature, which has broad implications for optimizing urban heat stress mitigation strategies. These findings are valid for operational metrics of heat stress for shaded conditions (apparent temperature and humidex), thermodynamic proxies (wet‐bulb temperature), and empirical heat indices. Based on this large‐scale empirical evidence, surface temperature, used due to the lack of better alternatives, may not be suitable for accurately informing heat mitigation strategies within and across cities, necessitating more urban‐scale observations and better urban‐resolving models.

54 ENVIRONMENTAL SCIENCES↗

Perovskite Photovoltaics: Venturing Outdoors

Metal halide perovskite solar cells have shown promising performance, but mainly on small-area devices and under laboratory conditions. Now, researchers have demonstrated the fabrication of large-area devices assembled and packaged into modules and reported on their operation outdoors.

field testing↗

The hidden costs of concealing outdoor air conditioning units

The beautification of urban facades in China often includes covers for the outdoor units of air conditioners. Although these covers improve cityscapes, they reduce cooling efficiency, increase noise pollution, risk system failures and embody carbon emissions. A call urges rethinking their necessity, and presses for sustainable, efficient design to counteract extreme heat.

Wang, Wei↗

Outdoor measurements of a photovoltaic system using diffractive spectrum-splitting and concentration

In a single-bandgap absorber, photons having energy less than the bandgap are not absorbed, while those having energy larger than the bandgap lose the excess energy via thermalization. We present outdoor measurements of a photovoltaic system that overcomes these losses via spectrum splitting and concentration using a planar diffractive optic. The system was comprised of the diffractive optic coupled with GaInP and CIGS solar cells. The optic provides a geometric concentration of 3X for each solar cell. It is easily fabricated by single-step grayscale lithography and it is ultra-thin with a maximum thickness of only 2.5μm. Electrical measurements under direct sunlight demonstrated an increase of ~25% in total output power compared to the reference case without spectrum splitting and concentration. Since different bandgaps are in the same plane, the proposed photovoltaic system successfully circumvents the lattice-matching and current-matching issues in conventional tandem multi-junction solar cells. As a result, this system is also tolerant to solar spectrum variation and fill-factor degradation of constitutive solar cells.

14 SOLAR ENERGY↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗