Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

CCE Case Study: Baltavia Substation Power Outage

In this case study, we will examine a fictional event broadly inspired by the real power outages in Ukraine that took place in December 2015 and December 2016—both the result of cyber-enabled sabotage. The actual events of 2015 and 2016 were well-documented—the adversaries in these attacks gained access to a few power companies’ corporate networks, pivoted to industrial control system (ICS) networks, and created widespread physical effects in the form of power outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar and battery can reduce energy costs and provide affordable outage backup for US households

Distributed energy resources are promising solutions for household energy affordability and resilience as weather extremes and aging infrastructure intensify grid reliability risks. This study presents a comprehensive nationwide assessment of over 500,000 U.S. households, evaluating economic and backup viability of solar-battery systems. We find that 60% of households could reduce electricity costs with average savings of 15%, while 63% of households could achieve affordable backup power during power outages covering an average of 51% of their essential energy needs. However, these benefits show limited alignment with areas of greatest need, particularly in regions facing high outage risks. We also identify significant disparities in access to solar and battery, with less-populated and disadvantaged communities showing consistently lower viability. Furthermore, these findings demonstrate the need for targeted policy interventions to ensure equitable access to solar-battery benefits, especially as states transition from net energy metering to other electricity tariff policies.

14 SOLAR ENERGY↗

Recent performance of and plasma outage studies with the SNS H{sup −} source

Spallation Neutron Source ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised radio frequency quadrupole (RFQ), which requires higher radio frequency power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H{sup −} beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ∼55-kW 2-MHz plasma pulses reflecting ∼90% of the continuous ∼300 W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly detuned 13-MHz match. Lowering the H{sub 2} gas also increased the H{sup −} beam current to ∼55 mA and increased the RFQ transmission by ∼7% (relative)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A resource adequacy assessment of correlated wide-area outages in the power grid

As the power grid is undergoing rapid transformations, numerous questions are emerging about its vulnerability to wide-area extreme events (WAEE), which could influence its operations. Relatively few analyses have been conducted to date regarding the impact of correlated outages during WAEEs on the grid’s ability to balance resources with demand. This study addresses this gap by conducting a resource adequacy analysis for a hurricane-inspired WAEE on a 2035 synthetic power grid system for the United States. A sensitivity analysis was also conducted to characterize the relative impact of weather on unserved energy. Our results indicate that although the magnitude and duration of the shortfalls vary depending on weather conditions, persistent shortfalls are observed in some regions. Initial explorations indicate a strong correlation between transmission-constrained regions and regions with persistent shortfalls. Future work could generate empirically-grounded representations for generator outages as well as conduct causal analyses of these shortfalls to improve understanding of drivers as well as possible mitigation strategies. Continued exploration of extreme weather impacts on the grid is important to develop more robust understanding of the reliability and resilience of our power systems, especially as they undergo rapid transformations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EAGLE-I Power Outage Data 2023

The provided EAGLE-I historic dataset includes 1 year of power outage information at the county level for 2023 at 15-minute intervals collected by the EAGLE-I program at ORNL. The data has been collected from utility's public outage maps using an ETL process. The dataset details FIPS code, county name, state name, total number of customers without power, and a date/timestamp. Also included is the EAGLE-I coverage of each state for each year. For detailed metadata, refer to the metadata DOI.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EAGLE-I Power Outage Data Information

This DOI contains information on the EAGLE-I power outage dataset and serves as a blanket DOI for all EAGLE-I historic data. Historic power outage data from specific years have been linked to this DOI.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Energy Efficiency and Distributed Generation for Resilience: Withstanding Grid Outages for Less

Communities across the United States experience extreme weather-related events that lead to disruptions in electric service. In 2017 alone, the nation experienced droughts, floods, freezes, hurricanes, and wildfires that cumulatively cost over $300 billion in damages and led to longer and more frequent disruptions in power. Without on-site backup power, these disruptions endanger public safety, security, and health. To better prepare for future disruptions, state and local governments are reducing the electric demand of their critical operations through energy efficiency, as well as making new investments in microgrids with distributed generation to ensure continuous electric supply during extended grid outages to power critical facilities. This resource describes how energy efficiency can be integrated planning for microgrids for resilience at critical public facilities, lowering the cost of a new system that can sustain operation during a grid outage. It includes real world examples as well as modeled scenarios to illustrate how efficiency can achieve energy and cost savings.

grid energy, power outages, microgrid, distributed↗

Outage management and health physics issue, 2009

The focus of the May-June issue is on outage management and health physics. Major articles include the following: Planning and scheduling to minimize refueling outage, by Pat McKenna, AmerenUE; Prioritizing safety, quality and schedule, by Tom Sharkey, Dominion; Benchmarking to high standards, by Margie Jepson, Energy Nuclear; Benchmarking against U.S. standards, by Magnox North, United Kingdom; Enabling suppliers for new build activity, by Marcus Harrington, GE Hitachi Nuclear Energy; Identifying, cultivating and qualifying suppliers, by Thomas E. Silva, AREVA NP; Creating new U.S. jobs, by Francois Martineau, Areva NP. Industry innovation articles include: MSL Acoustic source load reduction, by Amir Shahkarami, Exelon Nuclear; Dual Methodology NDE of CRDM nozzles, by Michael Stark, Dominion Nuclear; and Electronic circuit board testing, by James Amundsen, FirstEnergy Nuclear Operating Company. The plant profile article is titled The future is now, by Julia Milstead, Progress Energy Service Company, LLC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗

SPATIOTEMPORAL TRACKING OF WIDE AREA POWER OUTAGE FROM NIGHT-TIME LIGHT IMAGERY

Monitoring progress of power restoration following extreme events is essential for situational awareness about spatio-temporal distribution of populations without power and to help with response efforts. Because of the proprietary nature of restoration data, and the difficulty in obtaining power outage data from utility companies in near real-time (e.g., during hurricane Maria (2017)), this project used satellite derived nighttime lights data from Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) to (i) monitor wide area power outage and (ii) estimate impacted customers over time to assist with restoration. A discussion of the methodology and its implementation during hurricanes Maria (2017) and Eta (2020) is presented in this paper. Future work will focus on calibrating estimated customers based on light intensity and density distribution, and generation of restoration profiles for emergency response.

Kar, Bandana↗

Outage Analysis for Cooperative mmWave UAV Communications With Beam Training Overhead

In this letter, we investigate the tradeoff between reliability and beam training overhead in cooperative millimeter wave (mmWave) unmanned aerial vehicle (UAV) communications. In particular, we analyze how outage probability varies with the number of neighboring UAVs being probed as potential relays for relay selection. Unlike existing work, the limited number of UAV beams as well as UAV orientations are explicitly considered in our analysis. Here we derive the outage probability in closed form and verify our analysis via simulations. The results facilitate us to understand the fundamental limits of cooperative mmWave UAV communications.

99 GENERAL AND MISCELLANEOUS↗

Risk Assessment of Cascading Outages: Part I - Overview of Methodologies

This paper is a result of ongoing activity carried out by Understanding, Prediction, Mitigation and Restoration of Cascading Failures Task Force under IEEE Computer Analytical Methods Subcommittee (CAMS). The task force's previous papers are focused on general aspects of cascading outages such as understanding, prediction, prevention and restoration from cascading failures. This is the first of two new papers, which will extend this previous work to summarize the state of the art in cascading failure risk analysis methodologies and modeling tools. This paper is intended to be a reference document to summarize the state of the art in the methodologies for performing risk assessment of cascading outages caused by some initiating event(s). A risk assessment should cover the entire potential chain of cascades starting with the initiating event(s) and ending with some final condition(s). However, this is a difficult task and heuristic approaches and approximations have been suggested. This paper discusses diffeent approaches to this and suggests directions for future development of methodologies.

Vaiman, Marianna↗

Overcoming Communications Outages in Inverter Downtime Analysis

This paper presents two methods of detecting inverter downtime and estimating lost production from downtime events using timeseries system production measurements. The methods focus on distinguishing communications interruptions from true production outages and are successful in most cases. To enable fleet-scale analysis of inverter availability, the methods are designed to be semi-autonomous. The first method uses only inverter and system meter AC power measurements while the second uses cumulative production and expected energy data to classify outages and estimate lost production. The methods are demonstrated using real field data and the results are discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Sample Results from MCU Solids Outage

Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate; An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or additional details are provided below as recommendations. From this point on, IC-Anions analyses of the DSSHT should be part of the monthly routine analysis in order to spot negative trends in the oxalate leaving the MCU system. Care must be taken to monitor the oxalate content to watch for sudden precipitation of oxalate salts in the system; Conduct a study to optimize the cleaning strategy at ARP-MCU through decreasing the concentration or entirely eliminating the oxalic acid; The contents of the SSFT should remain unagitated. Routine visual observation should be maintained to ensure there is not a large buildup of solids. As water with agitation provided sufficient removal of the solids in the feed tank, it should be considered as a good means for dissolving oxalate solids if they are found in the future; Conduct a study to improve prediction of oxalate solubility in salt batch feed materials. As titanium and mercury have been found in various solids in this report, evaluate if either element plays a role in oxalate solubility during processing; Salt batch characterization focuses primarily on characterization and testing of unaltered Tank 21H material; however, non-typical feeds are developed through cleaning, washing, and/or sump transfers. As these solutions are processed through MCU, they may precipitate solids or reduce performance. Salt batch characterization and testing should be expanded to encompass a broader range of feeds that may be processed through ARPMCU.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method for estimating power outages and restoration during natural and man-made events

A method of modeling electric supply and demand with a data processor in combination with a recordable medium, and for estimating spatial distribution of electric power outages and affected populations. A geographic area is divided into cells to form a matrix. Within the matrix, supply cells are identified as containing electric substations and demand cells are identified as including electricity customers. Demand cells of the matrix are associated with the supply cells as a function of the capacity of each of the supply cells and the proximity and/or electricity demand of each of the demand cells. The method includes estimating a power outage by applying disaster event prediction information to the matrix, and estimating power restoration using the supply and demand cell information of the matrix and standardized and historical restoration information.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent Performance of and Plasma Outage Studies with the SNS H- Source

SNS ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised RFQ, which requires higher RF power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H- beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ~55-kW 2-MHz plasma pulses reflecting ~90% of the continuous ~300W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly-detuned 13-MHz match. Lowering the H2 also increased the H- beam current to ~55 mA, and increased the transmission by ~7%.

H- ion source↗