Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Northwest Coordinate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

What Can We Learn from US National Transmission Studies?

Multiple US regions have announced new electricity transmission plans, are actively revisiting the future role of transmission, and could benefit from findings from recent national-scale transmission studies. A review of seven national studies shows that significant transmission expansion is cost-optimal for serving new demand, integrating additional resources, and supporting grid reliability. A majority of the reviewed scenarios, which span a range of policy and technology assumptions, include at least a doubling of the transmission system by 2050. The national studies find substantial net system cost savings from transmission expansion and high benefit-cost ratios for transmission investments. The results are derived through multi-value, nationally coordinated, co-optimized, multi-scenario modeling, which is an approach that could yield lower-cost pathways compared to current industry planning practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

More land is needed for solar and wind infrastructure under a high renewables scenario in the Western US by 2050

Expanding United States electricity infrastructure to meet growing demand could require extensive power plant development footprints and land use conversion, depending on the mix of generation types chosen. Understanding where future power plant sitings are likely to take place and identifying potential conflicts and land-use tradeoffs will be key to identifying feasible and affordable investments and evaluating regional planning coordination needs. Here we use an integrated modeling framework that combines capacity expansion planning, hourly grid operations, and geospatial techno-economic analysis to develop projections (2025-2050) of power plant sitings in the Western United States (US) at a 1 km 2 resolution for a business-as-usual scenario and a high renewables penetration scenario. We find that 30% more land will be needed in the high renewables scenario as compared to business-as-usual, and that 75% of that development is projected to be located within 10 km of natural areas.

Mongird, Kendall [Pacific Northwest National Labor↗

Opportunities to Implement Solutions to Achieve Remedial Action Objectives in Consideration of Stakeholder Interests - 20365

A case study in the implementation of a soils excavation and removal project conducted at a Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) vicinity property; an active commercial business, in a densely populated area, with significant operational, technical and, logistical constraints that were expected to limit areas that could be remediated. The United States Army Corps of Engineers-led (USACE) team successfully navigated complex overlapping stakeholder interests to achieve a more efficient and complete removal of contaminated soils and debris while minimizing unnecessary excess costs to the Government. This paper centers on FUSRAP activities at the FMSS vicinity property located at 149-151 Maywood Avenue, Maywood, Bergen County, New Jersey. For most of its FUSRAP history, this ∼109,000 square meter (27-acre) property housed a now-demolished ∼26,000 square meter (6.5-acre) warehouse operated by Sears Logistics Services, a unit of the Sears Roebuck Company (Figure 2). Sears ended its property lease and vacated the warehouse in December 2016. Given that long history and for the purposes of this paper, the property will be referred to as the 'Sears property' or simply 'the property.' The Sears property is approximately 109,000 square meters (27-acres) and is currently zoned for commercial use. The property is bound to the north and northwest by 100 West Hunter Avenue (the Stepan Company), to the northeast by 205 Maywood Avenue, to the east by Maywood Avenue, to the south by 23 West Howcroft Road, and to the west by businesses on NJ Route 17 and the NJ Route 17 roadway. Until December 2016, the property housed a warehouse and distribution center operated by Sears Logistical Services. On-site structures were demolished by the property owner in 2017. The warehouse covered the north section of the property along the Stepan Company property line. A railroad spur from the adjacent property now known as the Maywood Interim Storage Site (MISS) ended at the northeast corner of the warehouse. Wetlands were located east of the warehouse; the rest of the property was covered with paved parking lots and grassed areas. During remediation at the property, opportunities frequently arose where the project team was able to coordinate effectively with stakeholders to sequence remediation activities to facilitate removal of otherwise inaccessible soils and identify opportunities for materials reuse when supported by residual radiological and chemical levels. Some specific opportunities include: - remediating individual truck loading dock bays to maintain tenant operations; - working along a busy highway and in a utility corridor containing a 30-inch high pressure gas main; - remediating Lodi Brook and associated wetlands requiring bypass pumping and other diversionary structures to maintain local community stormwater drainage; - protecting during remediation and supporting access to facilitate tenant/owner maintenance of critical fire protection and water supply system service lines buried in contaminated soils and necessary for safe warehouse operations; and - coordinating with stakeholders to ensure non-radiological contaminants of concern for the site (unaffiliated with FUSRAP) were addressed by the responsible party in a manner that maximized benefit to all parties while supporting an efficient overall site remediation program. Once the property was vacant and the warehouse structure and radiologically non-impacted above-grade structures were demolished, the project identified an opportunity to significantly reduce the volume of waste associated with the foundation of the former warehouse, a foundation suspected of being partially constructed in radiologically contaminated soils. The project developed and implemented supplemental radiological verification survey and sampling strategies based on radiological cross-contamination risk potential with process flow-charts and screening-level based decision points; a program that classified saw-cut sections of concrete based on observed residual surface radioactivity conditions using a combination of gamma sensitive sodium-iodide scans and beta sensitive Geiger-Muller direct measurements. The proposed approach was reviewed with stakeholders with feedback, including consideration of applicable State of New Jersey Site Remediation Program criteria and guidance before implementation. Once classified, additional sampling was performed at frequencies driven by screening. The sampling methods, stockpile sampling frequencies, criteria and, approach to data evaluation were developed in consideration of existing site cleanup standards, regional background ranges, State of New Jersey radiological remediation program guidance, and specific stakeholder input With the property remediation and survey efforts nearly completed, it is relevant to examine retrospectively the objectives, assumptions and limitations in the remedial design (i.e., what was planned) versus what was able to be accomplished through effective teaming. Benefits to other environmental remediation site programs include better understanding of how to work effectively with stakeholders to achieve win-win outcomes, and approaches to site remediation, waste minimization and materials reuse that were successful in their overall outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U 4+/5+/6+ in a Conserved Pseudotetrahedral Imidophosphorane Coordination Sphere

While several ligand systems support uranium across a range of oxidation states, spanning more than two oxidation states in a conserved coordination geometry is uncommon among structurally authenticated complexes. Imidophosphorane ligands significantly stabilize high-valent lanthanide and actinide complexes. Here, we report a series of homoleptic uranium imidophosphorane complexes, spanning the +4, +5 and +6 oxidation states in a four-coordinate pseudotetrahedral ligand field. The +6 oxidation state is accessible using a mild ferrocenium oxidant, yielding a rare example of U6+ in a pseudotetrahedral coordination environment. As the formal oxidation state increases, the U–N distances gradually contract, consistent with the Shannon ionic radii of U 4+/5+/6+ . Compared to reported complexes, the short U–N distances observed in the U 6+ complex are more comparable to dianionic imido ligands than monoanionic amido ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Control for Fast Frequency Response and Black-Start using Embedded Storages with Grid-Forming Control

The grid-forming inverter is regarded as the solution for integrating high levels of renewable resources into future power systems. Ensuring the stable operation of grids necessitates that grid-forming inverters offer fast frequency response. This report introduces an optimal control method that coordinates the embedded storage within the grid-forming control model with conventional synchronous generators. The optimized active power reference for the embedded storage is generated using receding horizon optimization control, aiming to keep the center of inertia frequency within acceptable limits. The effectiveness of the proposed control is verified through testing in the IEEE 39-bus system. In addition, with grid-forming capability, we will also investigate the application of using mobile embedded storages as black-start units to provide cranking power to energize non-blackstart generators in a black-start process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standard Library Grid-Forming Hybrid Control Inverter-Based Resource Model Specification (REGFM_C1)

This document describes a standard library grid-forming (GFM) hybrid control inverter-based resource (IBR) model. The GFM hybrid control approach implements both a typical GFM control and a typical grid-following (GFL) control inside one single inverter simultaneously, so that it can take advantage of both methods without comprising the benefits of a typical GFM. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control blocks to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cross-aldol condensation on missing linker sites of metal–organic framework UiO-66

Missing linkers induce coordinatively unsaturated Lewis acid-base pair sites in metal–organic frameworks such as UiO-66 (Zr). The Lewis acid-base pair is induced by replacing the benzene dicarboxylic acid linker with formic acid, which subsequently is thermally decomposed. The concentration of coordinatively unsaturated Zr 4+ cations was titrated with acetone. In parallel to their concentration, the catalytic activity increased while the selectivity for aldol condensation between furfural and acetone remained constant. The missing linkers generate a complex ensemble consisting of an (at least partly) accessible Zr 4+ cation surrounded by oxygen, catalyzing the cross-aldol condensation. As a result, density functional theory calculations, matching the experimental findings provide a more detailed understanding of the elementary steps during the condensation reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assembled peptoid crystalline nanomaterials as carbonic anhydrase mimics for promoted hydration and sequestration of CO 2

Carbonic anhydrase (CA) mimics have received significant attention due to their promising applications in the enhanced hydration and sequestration of CO 2 . Herein, we report the assembly of sequence-defined peptoids into crystalline nanomaterials with controlled microenvironment of active sites as CA mimics for promoted hydration and sequestration of CO 2 . By incorporating specific ligands into self-assembling peptoids and coordinating these ligands with metal cations, we synthesize a variety of crystalline nanosheets and nanotubes as efficient CA mimics comparable to natural bovine CA. Molecular dynamics simulations reveal the critical roles of peptoid-Zn 2+ binding energy and the active site local microenvironment on the catalytic performance of these CA mimics. CO 2 precipitation results show that these CA mimics promote the hydration and sequestration of CO 2 while retaining high thermal and chemical stabilities. This study offers essential guidance for the future design of high-performance CA-mimics suitable for applications in CO 2 capture and sequestration.

Chakma, Progyateg [Pacific Northwest National Labo↗

Representation and Impact of Water Head on Power System Planning and Operation

Representing water head information in power system model files, can provide a more realistic model of the system and thereby inform operation and planning personnel in the decision-making process. This article describes a procedure for modifying the power system model files (steady-state and dynamic) to represent water head information. Additionally, the impact of representing the water head on power system reliability studies including contingency analysis, cascading failure analysis and dynamic frequency response analysis has been investigated, using the modified power system models. This paper considers the detailed Western Electricity Coordination Council model during summer and winter conditions as the test system for the impact analysis. Results show that under reduced water head: 1) the number of critical voltage and branch flow violations increases; 2) chances of cascading failure and island formation increases; and 3) frequency nadir decreases as compared to those of the base cases where the water head information is not represented.

13 - HYDRO ENERGY↗

Synthetic Atmospheric River Ensembles Generated by Deep-AR

This dataset contains 35,850 synthetic landfalling atmospheric river (AR) realizations generated by the Deep-AR two-stage deep-learning framework over the Northeast Pacific and U.S. West Coast. The archive contains 25 stochastic ensemble members for each of 1,434 held-out observed seed events. Each synthetic realization is initialized from conditions 48 hours before the corresponding observed AR landfall and is generated autoregressively at 6-hour intervals over a 144-hour period. Deep-AR combines a deterministic residual network (ResNet) that advances the large-scale atmospheric state with a Wasserstein generative adversarial network (WGAN) that produces stochastic, high-resolution fields. Each HDF5 file contains 0.25° gridded synthetic integrated vapor transport components (qu, qv), 10 m wind components (u10, v10), and 6-hour accumulated precipitation on a common 200 × 480 grid. The files also include coordinate and datetime arrays. This dataset supports AR hazard analysis, ensemble-based uncertainty characterization, precipitation-extremes research, and regional stress testing. Synthetic files follow the naming convention deepar.model.YYYYMMDD.HHMMSS.vNN.h5. YYYYMMDD.HHMMSS identifies the UTC initial-condition timestamp, which occurs 48 hours before the diagnosed observed landfall, and vNN identifies the zero-padded ensemble member, ranging from v01 through v25. Each synthetic file can be paired with its corresponding observed file by matching the initial-condition timestamp. The paired observed file follows the naming convention deepar.obs.YYYYMMDD.HHMMSS.h5 and is available in the separately registered oracle/deepar.obs dataset at https://wdh.energy.gov/ds/oracle/deepar.obs (DOI: https://doi.org/10.21947/3377671).

17 WIND ENERGY↗

Enhancing carbon storage through proactively managing fire-prone coniferous mountain forests

Mountain ecosystems typically serve as carbon (C) sinks. However, studies also suggest that they could be C sources due to climate warming, drought and insect-related mortality, wildfires, and management actions. We applied the Lund-Potsdam-Jena General Ecosystem Simulator (LPJ-GUESS), a process-based dynamic vegetation-ecosystem model, to investigate the role of ecosystem management in C storage under Mediterranean climate over the 21 st century. We modified LPJ-GUESS to include implementing mechanical thinning by vegetation size classes, components, and types along with a new mechanistic fire-occurrence model that accounts for wind speed and lightning ignition. Simulations show that mechanical thinning or prescribed fire performed 5-20 years in advance of a high-severity wildfire reduced direct wildfire C emissions by 38-66 %. Our results also show that long-term management actions repeated every 5-20 years, including thinning relatively small trees (diameters up to 7 inches or ∼178 mm), can maintain stable C levels in the forest and lower dead-fuel amounts. We found that, although prescribed fire mitigated wildfire severity, ecosystem C storage from reduced wildfire emissions can be outweighed by the added emissions from the prescribed fire themselves. Thinning plus removing and sequestering the thinned biomass can ensure that forests act as net C sinks through the end of the 21 st century. However, addition of prescribed fire is needed to reduce understory and lower the projected extent of high-severity wildfire. Achieving the competing goals of reducing wildfire and making the Sierra Nevada long-term C sink can be advanced through carefully coordinated thinning, sequestration of thinned biomass, and prescribed fire.

Climate solutions↗

Unraveling Anion-Specific Inhibition and Structural Modulation of Gibbsite Crystallization: Implications for Aluminum Mobility in Natural and Engineered Systems

Gibbsite (α-Al(OH) 3 , sometimes designated as γ-Al(OH) 3 ) plays a crucial role in the chemistry of aluminum in the environment and industry, yet its crystallization behavior under multianionic conditions is not well understood. Here, in this study, we investigate how six common anions─fluoride (F – ), chloride (Cl – ), bromide (Br – ), nitrate (NO 3 – ), sulfate (SO 4 2– ), and phosphate (PO 4 3– )─influence the mineralization, structure, and morphology of gibbsite at room temperature. The results show that PO 4 3– , SO 4 2– , and F – strongly inhibit gibbsite formation, stabilizing amorphous or alternative crystalline phases such as nordstrandite and cryolite. On the contrary, Cl – , Br – , and NO 3 – allow partial to complete crystallization of gibbsite without significant morphological changes. Solid-state 27 Al magic angle spinning nuclear magnetic resonance provides crucial insight into aluminum coordination environments in both crystalline and amorphous phases, distinguishing between octahedral, pentahedral, and tetrahedral Al species. The density functional theory calculations reveal a direct correlation between the Al–X bond strength and the inhibition of crystallization, following the order: PO 4 3– > SO 4 2– > F – > NO 3 – > Cl – > Br – . These findings offer molecular-scale insights into anion-specific effects on aluminum hydroxide nucleation and transformation, improving the understanding of gibbsite formation and aluminum cycling in soils, phosphate retention, contaminant immobilization, and waste treatment strategies in nuclear and industrial settings. These insights can also guide the controlled synthesis of aluminum hydroxide materials with tailored crystallinity and morphology via liquid-assisted methods.

Anions effect↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

FIU Project 2: Environmental Remediation Science & Technology [Slides]

FIU’s research under this project involves conducting basic and applied science to fill knowledge gaps and validate potential remediation technologies for contaminated soil and groundwater and the assessment of the fate and transport of contaminants in the environment. The aim of FIU’s research is to reduce the potential for contaminant mobility or toxicity in the surface and subsurface through the development and application of state-of-the-art scientific and environmental remediation technologies at the Hanford Site, Savannah River Site (SRS), and the Waste Isolation Pilot Plant (WIPP), which is the Nation’s only mined geologic repository for permanent disposal of transuranic waste. FIU collaborates with scientists from Pacific Northwest National Laboratory (PNNL), Savannah River National Laboratory (SRNL), Savannah River Ecology Laboratory (SREL), Los Alamos National Laboratory (LANL) and the DOE Carlsbad Field Office (CBFO) in order to plan and execute research that is synergistic with the work being conducted at the sites, and that supports the resolution of critical science and engineering needs which leads to a better understanding of the long-term behavior of subsurface contaminants. The knowledge gained through this research will be used to transform experimental and modeling innovations into practical applications deployed at the sites to support EM’s primary goal of expediting the closure of major contaminated soil and groundwater sites and waste units. Collaborative relationships between FIU and the national laboratories have provided large benefits over the years to FIU, the national laboratories, the DOE complex, and the DOE EM mission. By working closely with the national laboratories, FIU’s research is not only closely aligned with the cleanup mission priorities at the DOE sites, but complements and supports ongoing work at the national laboratories for screening of new remedial technologies. This coordination and leveraging of research efforts results in time- and cost-savings, and will accelerate progress of the DOE EM environmental restoration mission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unleashed from constrained optimization: quantum computing for quantum chemistry employing generator coordinate inspired method

Hybrid quantum-classical approaches offer potential solutions to quantum chemistry problems, yet they often manifest as constrained optimization problems. Here, we explore the interconnection between constrained optimization and generalized eigenvalue problems through the Unitary Coupled Cluster (UCC) excitation generators. Inspired by the generator coordinate method, we employ these UCC excitation generators to construct non-orthogonal, overcomplete many-body bases, projecting the system Hamiltonian into an effective Hamiltonian, which bypasses issues such as barren plateaus that heuristic numerical minimizers often encountered in standard variational quantum eigensolver (VQE). Diverging from conventional quantum subspace expansion methods, we introduce an adaptive scheme that robustly constructs the many-body basis sets from a pool of the UCC excitation generators. This scheme supports the development of a hierarchical ADAPT quantum-classical strategy, enabling a balanced interplay between subspace expansion and ansatz optimization to address complex, strongly correlated quantum chemical systems cost-effectively, setting the stage for more advanced quantum simulations in chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subsurface hydrogen, curvature, and strain: lessons from electro-reduction of benzaldehyde on nano-structured Pd catalysts

The unique ability of palladium (Pd) to absorb hydrogen and form a bulk hydride is vital for chemical transformations that involve hydrogenation reactions. Nano-structured Pd catalysts offer a promise of tuning these reaction rates by exploiting variations of reactant binding energies depending on the surface structure and morphological constraints that result in inhomogeneous strain. However, the interplay between the nano-structure of Pd and the ability of Pd to adsorb (and absorb) hydrogen as well as other reactive species needs to be better understood for a rational understanding of competitive chemical transformations at Pd surfaces. We consider the effects of the surface corrugation, strain, and subsurface Pd hydride on the reduction of benzaldehyde to benzyl alcohol in two qualitatively different samples – Pd nanoparticles and Pd gels formed by quasi-one-dimensional chains of these nanoparticles. Our electrochemical measurements and computational modelling suggest that surface concave sites, inherent to Pd gels, facilitate hydrogen transfer to the Pd subsurface region, thus weakening benzaldehyde binding to the surface. This effect is further modulated by the strain, depending on the local coordination environment on the corrugated surface. Furthermore, these findings demonstrate how structurally complex samples in the form of gels provide degrees of freedom for controlling the behavior of metal catalysts that are not available in isolated nanoparticles, which paves the way for new approaches in the design of catalytic materials and synthesis of metal hydrides.

Padavala, Sri Krishna Murthy [University of Minnes↗