Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of active neutron interrogation of special nuclear materials using a high-intensity short-pulse-laser-driven neutron source

Detecting shielded special nuclear material, such as nuclear explosives, is a difficult challenge pursued by non-proliferation, anti-terrorism, and nuclear security programs worldwide. Interrogation with intense fast-neutron pulses is a promising method to characterize concealed nuclear material rapidly but is limited by suitable source availability and proven instrumentation. In this study we have pioneered a demonstration of such an interrogation method using a high-intensity, short-pulse, laser-driven neutron source that offers potential benefits compared to conventional neutron sources. The measurement results reported here represent the first experimental demonstration of this interrogation approach on enriched uranium items and demonstrate the feasibility of a precise measurement using realistic nuclear materials, representative of field scenarios, even with just a single laser-driven neutron pulse. Bright pulsed sources can overcome the nuisance background of items with strong internal neutron sources, improving analytical power, while single-shot assay is attractive in high-throughput situations where time is at a premium. The science and technology of this type of neutron production is developing rapidly, and we anticipate that practical mobile interrogation systems will become available based on the detection concepts demonstrated here to meet the growing measurement needs.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Characterization of mechanical properties and deformation behavior of highly irradiated 316L stainless steel from target modules at the Spallation Neutron Source using digital image correlation analysis

Tensile specimens with irradiation doses ranging from approximately 0.7 to 7.6 displacements per atom (dpa) were fabricated from 316L samples removed from Spallation Neutron Source (SNS) target vessels after service. Tensile tests were performed in conjunction with digital image correlation (DIC) characterization, which permitted detailed analysis of the strain distribution and deformation behavior of the specimen gauge sections during testing. The results show, while considerable hardening (500–700 MPa increase in yield strength) occurred in the 316L SNS target material with increasing dose, appreciable ductility (19–23% total elongation) remained in the material after irradiation to 7.6 dpa in the mixed neutron/proton environment of the SNS target region. The DIC data showed the strain distribution and deformation behavior of all irradiated specimens were nonuniform during testing. Strain localization in the form of deformation bands or “hotspots” was observed during testing, and in some specimens, the bands propagated as deformation waves along the gauge section. The “traveling wave” deformation behavior affected the amount of elongation each specimen achieved, and the scatter in the elongation data was attributed to the large variation in deformation behavior observed among different specimens. Bands of localized strain, or deformation bands, oriented at specific angles were observed in two-dimensional plots of the strain distribution in the gauge sections of some specimens. Overall, this paper describes the experimental procedures, results, and deformation behavior of tensile specimens from SNS targets after service and illustrates the value of DIC characterization during tensile testing of irradiated materials.

36 MATERIALS SCIENCE↗

System and method for fissionable material detection with a short pulse neutron source

A system and method is disclosed for detecting fissionable materials. In one embodiment the system may incorporate a neutron pulse generator configured to generate multiple short pulses of neutrons, or a single pulse of sufficient intensity, in a vicinity of an object of interest. The source pulse of neutrons includes neutrons which each have a full width half maximum time duration of less than about 100 ns and a peak energy level no greater than about 20 MeV. A fast response detector is used which is able to detect single neutron events indicative of fission neutrons having been produced by the source pulse of neutrons interacting with fissionable material associated with the object of interest, and which arrive at the fast response detector within a predetermined time window immediately before arrival of the source neutron pulses.

Podpaly, Yuri↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

Overview of Shielding Analyses at Oak Ridge National Laboratory’s Spallation Neutron Source Second Target Station

The Neutronics Group of the Second Target Station project at Oak Ridge National Laboratory is responsible for all neutronics analyses related to design and construction. This paper provides an overview of four neutronics analyses performed for the Second Target Station project, which is representative of all the ongoing work but especially tasks related to shielding. These analyses extend from the proton accelerator through the target monolith and bunker to the end of a neutron beamline. Each example highlights the tools and methods the Neutronics Group uses for analysis. The primary tool is the Monte Carlo radiation transport code MCNP 6.2, but this is augmented by other codes that supplement the input of MCNP. The other codes specifically highlighted in this paper include Attila4MC, ADVANTG, and AARE.

Miller, Thomas↗

M-STAR: Magnetism second target advanced reflectometer at the Spallation Neutron Source

M-STAR is a next generation polarized neutron reflectometer with advanced capabilities. A new focusing guide concept is optimized for samples with dimensions down to a millimeter range. A proposed hybrid pulse-skipping chopper will enable experiments at constant geometry at one incident angle in a broad range of wavevector transfer Q up to 0.3 A –1 for specular, off-specular, and GISANS measurements. M-STAR will empower nanoscience and spintronics studies routinely on small samples (~2 × 2 mm 2 ) and of atomic-scale thickness using versatile experimental conditions of magnetic and/or electric fields, light, and temperature applied in situ to novel complex device-like nanosystems with multiple buried interfaces. M-STAR will enable improved grazing incidence diffraction measurements, as a surface-sensitive depth-resolved probe of, e.g., the out-of-plane component of atomic magnetic moments in ferromagnetic, antiferromagnetic, and more complex structures as well as in-plane atomic-scale structures inaccessible with contemporary diffractometry and reflectometry. New horizons will be opened by the development of an option to probe near-surface dynamics with inelastic grazing incidence scattering in the time-of-flight mode. These novel options in combination with ideally matched parameters of the second target station will place M-STAR in the world’s leading position for high resolution polarized reflectometry.

47 OTHER INSTRUMENTATION↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Available DT fusion neutron sources

For consideration for diagnostic and technology development for a deuterium and tritium (DT) fusion system, we briefly list here the available DT fusion systems, their characteristic information, such as yields, flux, the pulse width, rep rate and approximate spectrum. We also briefly list other neutron sources for comparison. This is not meant to be exhaustive but a sampling of recent and available sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Quantifying the reduction in cavitation-induced erosion damage in the Spallation Neutron Source mercury target by means of small-bubble gas injection

Here, a model developed to represent the progress of erosion damage in liquid-metal spallation target vessels was modified to incorporate the effect of gas injection on the erosion rate. The liquid mercury target system for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory now operates with helium gas injection to reduce target vessel fatigue stress and cavitation-induced erosion damage. Erosion damage is a primary degradation phenomenon affecting the service life of SNS target vessels, and cavitation mitigation techniques, such as small-bubble gas injection, have been implemented to reduce damage and extend target lifetimes. Erosion depths in samples removed from SNS targets after operation were measured using laser line scanning. These measurements confirmed that gas injection reduced erosion damage. However, quantifying the damage reduction due to gas injection was complicated by variations in lifetime, power, and gas injection rates between different targets. In this study, the operating power and gas injection rate of targets were incorporated into an erosion damage prediction model to quantify their effects on erosion damage reduction. Values of a power scaling factor, β, were calculated by comparing modeled with measured erosion damage. These values indicate that the use of gas injection at the SNS reduced damage to a level equivalent to operating targets without gas injection at 35–47% of the actual beam power. To account for the gas injection effect on the cavitation damage, a simple exponential form based on analysis of the scaling factor β was developed to incorporate the gas rate history with a scaling factor γ in the erosion damage modeling.

47 OTHER INSTRUMENTATION↗

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Spallation Neutron Source Second Target Station Construction Project: Biological Assessment

The Endangered Species Act of 1973 (16 U.S.C. 153 et seq.), as amended (ESA or Act) in section 7(a)(1) directs Federal agencies to conserve and recover listed species and use their authorities in the furtherance of the purposes of the Act by carrying out programs for the conservation of endangered and threatened species so that listing is no longer necessary (50 CFR §402). Furthermore, the Act in section 7(a)(2) directs Federal agencies to consult (referred to as section 7 consultation) with the U.S. Fish and Wildlife Service (USFWS) when their activities “may affect” a listed species or designated critical habitat. This biological assessment (BA) analyzes the potential effects of the proposed Spallation Neutron Source Second Target Station STS construction project on the U. S. Department of Energy Oak Ridge Reservation (ORR) on Federal listed threatened, endangered, proposed, and under consideration for Federal listing bat species, pursuant to section 7(a)(2) of the ESA.

54 ENVIRONMENTAL SCIENCES↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Neutron source reconstruction using a generalized expectation–maximization algorithm on one-dimensional neutron images from the Z facility

Magnetized Liner Inertial Fusion experiments have been performed at the Z facility at Sandia National Laboratories. These experiments use deuterium fuel, which produces 2.45 MeV neutrons on reaching thermonuclear conditions. To study the spatial structure of neutron production, the one-dimensional imager of neutrons diagnostic was fielded to record axial resolved neutron images. In this diagnostic, neutrons passing through a rolled edge aperture form an image on a CR-39-based solid state nuclear track detector. In this report we present a modified generalized expectation–maximization algorithm to reconstruct an axial neutron emission profile of the stagnated fusion plasma. We validate the approach by comparing the reconstructed neutron emission profile to an x-ray emission profile provided by a time-integrated pinhole camera.

47 OTHER INSTRUMENTATION↗