At least 127 records · Page 7

Final Report: Water-Based Neutron Detector Technology for Material Characterization Well Counters

Coincidence counting of neutron pairs is an effective way to non-destructively determine the amount of fissile material within a sample of special nuclear material (SNM) [1]. Multiplicity counting is more versatile and precise, but also more demanding, requiring the detection of three or more neutrons per single fission event. Detecting a triple coincidence of neutrons depends on the 3rd power of the detection efficiency and so on. The detection efficiency quickly becomes the critical determining factor in evaluating the utility of a particular neutron multiplicity detection technique. The purpose of this feasibility study was to characterize the performance of an LLNLdesigned water Cherenkov based Multiplicity Well counter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron multiplication error in TRU waste measurements

Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron pileup algorithms for multiplicity counters

Abstract The shortage of helium-3 (3He) has created a need to identify alternative neutron detection options for a variety of nuclear nonproliferation applications. One application that may be affected by 3He replacement technology is that of mass accountancy for safeguards, which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. The use of neutron scintillation materials, such as LiF-ZnS sheets, as an alternative to 3He proportional tubes in multiplicity counters requires novel techniques for Pulse Shape Discrimination to distinguish between neutrons and gamma rays. These techniques must work under high count rates, as the maximum momentary rate for incoming neutrons from multiplicity events can be quite large. We have created a fast and accurate neutron discrimination algorithm based on time window filtering and signature comparison that can operate quickly on data with high degrees of gamma ray and neutron pileup. This algorithm is evaluated for its capability to separate signals as the pileup rate increases, and the possibility for implementation on fast hardware (e.g., FPGA hardware) for real-time operation is explored.

Robinson, Sean M.↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time Correlation Measurements of 252Cf Source Driven Fission Chains in Bare HEU Metal Assemblies

Passive multiplicity measurements of fissile metal assemblies are well established for measuring the multiplication, fissile content, and detection efficiency. In plutonium metal assemblies, most of the neutrons are unambiguously observed from fission chains because of the high spontaneous fission rate. However, uranium metal assemblies have low spontaneous fission rate such that the observed neutrons are a mixture of fission chain neutrons and cosmic-ray spallation neutrons. As a result, the multiplication, fissile content, and detection efficiency are difficult to measure without accurate quantification of the single neutron events unrelated to the fission chains. However, studying fission chains is simplified by knowing when each chain starts, which can be accomplished using a time-tagged active source such as a 252 Cf ionization chamber or a deuterium-tritium (D-T) neutron generator with an alpha detector. This paper presents time correlation measurements that have been performed with up to five 18 kg highly enriched uranium (HEU) storage castings and a 252 Cf ionization chamber placed near the center of each assembly. The measurements included liquid scintillators with pulse shape discrimination operating on the timescale of fission chains and 3 He proportional counters whose traditional use in multiplicity counting is well understood within a point-kinetics framework. Neutron time correlation distributions have been measured to characterize each assembly and are compared with the equivalent distributions collected passively.

252-Cf Ionization Chamber↗

In-depth evaluation of 252 Cf absolute calibration by passive neutron correlation counting method

252 Cf neutron sources are particularly convenient, and therefore widely used, to characterize and calibrate many kinds of neutron detectors for both scientific and technological applications. An emerging interest is the use of 252 Cf to calibrate neutron correlation counters for the verification and assay of Pu-items as part of the international effort to safeguard nuclear materials. Passive neutron correlation counting (PNCC) methods, combined with knowledge of the fission neutron multiplicity distribution, can be used as an absolute technique to determine the neutron emission rate of 252 Cf sources. This means that common equipment used by the safeguards community can, in principle, be used to self-certify, to high accuracy, the strength of physically small 252 Cf sealed sources for use in calibration. This is the first step in using 252Cf in place of extensive Pu reference materials for experimental calibration by the safeguards community. The theoretical foundation is already clear but the present work presents the first systematic attempt at demonstrating the practical utility of the concept across a variety of typical instruments. We compare four emission rate estimators for four detector configurations on a common source previously certified by the MnSO 4 -bath technique. We find that the estimator based on the singles to doubles rate ratio provides consistent and precise results across all of the instruments and that these agree with the MnSO 4 -bath technique within combined uncertainties. This success suggests that the absolute PNCC method could become a technically defensible and commonly used, method capable of sub 1% accuracy for routine calibration work.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance of coincidence-based PSD on LiF/ZnS Detectors for Multiplicity Counting

Abstract: Mass accountancy measurement is a nuclear nonproliferation application which utilizes coincidence and multiplicity counters to verify special nuclear material declarations. With a well-designed and efficient detector system, several relevant parameters of the material can be verified simultaneously. 6LiF/ZnS scintillating sheets may be used for this purpose due to a combination of high efficiency and short die-away times in systems designed with this material, but involve choices of detector geometry and exact material composition (e.g., the addition of Ni-quenching in the material) that must be optimized for the application. Multiplicity counting for verification of declared nuclear fuel mass involves neutron detection in conditions where several neutrons arrive in a short time window, with confounding gamma rays. This paper considers coincidence-based Pulse-Shape Discrimination (PSD) techniques developed to work under conditions of high pileup, and the performance of these algorithms with different detection materials. Simulated and real data from modern LiF/ZnS scintillator systems are evaluated with these techniques and the relationship between the performance under pileup and material characteristics (e.g., neutron peak width and total light collection efficiency) are determined, to allow for an optimal choice of detector and material.

Robinson, Sean M.↗

Determination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication.The results of this study show that analyzing the data stream using non-overlapping time gates is an improvement over the current analysis using overlapping time gates. The new method enables us to compute the standard deviation on the multiplication parameter M accurately. Also, this standard deviation on M decreases as the largest time gate is about 10 times the characteristic time constant λ -1 of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anisotropy of the neutron fluence from a plasma focus.

The fluence of neutrons from a plasma focus was measured by gamma spectrometry of an activated silver target. This method results in a significant increase in accuracy over the beta-counting method. Multiple detectors were used in order to measure the anisotropy of the fluence of neutrons. The fluence was found to be concentrated in a cone with a half-angle of 30 deg about the axis, and to drop off rapidly outside of this cone; the anisotropy was found to depend upon the total yield of neutrons. This dependence was strongest on the axis. Neither the axial concentration of the fluence of neutrons nor its dependence on the total yield of neutrons is explained by any of the currently proposed models. Some other explanations, including the possibility of an axially distributed source, are considered.

Lee, J. H.↗

Final Report on Phase I of the Accelerator Neutrino Neutron Interaction Experiment (ANNIE)

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) will address 1) the study of the nature of neutrino-nucleus interactions and 2) the development of promising new technologies for detecting neutrinos. The primary physics goal of ANNIE is to study the abundance of final state neutrons from neutrino-nucleus interactions. Measurements of final-state neutron multiplicity will improve our understanding of the complex, many-body dynamics of neutrino-nucleus interactions. Identifying and counting final state neutrons also provides a useful experimental handle for signal-background separation for future neutrino experiments. In addition to its physics goals, ANNIE is an effort that seeks to apply for the first time a promising new photodetector technology known as Large Area Picosecond Photodetectors (LAPPDs). The Phase I funding allowed to determine the feasibility of the experiment by measuring the neutron background in the experimental hall where the experiment will be located and is currently under construction.

47 OTHER INSTRUMENTATION↗

Validation of Statistical Uncertainties in Subcritical Benchmark Measurements: Part I - Theory and Simulations

Subcritical neutron noise measurements are often used to determine multiplication of a system with Special Nuclear Material. This work presents an uncertainty approach which incorporates the singles and doubles counting rates determined by the Hage-Cifarelli formalism. This is a moments-based approach which utilizes time correlations between prompt neutrons in order to assess the system multiplication. After the method is described, a validation is presented which utilizes simulated data generated using a 0-D point-kinetics Monte Carlo code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple-Coincidence Interrogation of Fissionables

The multiple coincidence technique uses 14.1 MeV neutrons to produce (n, multiple-γ) coincidences to detect fissile and fissionable materials. Measurements of n-γ-γ coincidences with targets of depleted uranium (DU), W, and Pb, show that the counting rate for the DU is substantially above that for the non-fissionables. Also, the data involving prompt neutrons and delayed gammas in the DU time spectra provide a signature for fissionables that is distinct from that of non-fissionables.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNPX270 LLNL Fission Model

The LLNL fission model is an available option in MCNPX version 2.7.0. It was developed at Lawrence Livermore National Laboratory and we have collaborated to implement it in MCNPX. We report here our observations and assessments of the LLNL fission model in MCNPX relative to alternative treatments in MCNPX. The LLNL fission model is the only way for MCNPX to produce correlated prompt gammas from prompt fission, delayed fission, spontaneous fission, and photofission. The LLNL fission model also produces fission neutrons and gammas with the correct multiplicities for induced fission, spontaneous fission, and photofission. The exact modeling of the neutron- and photon-induced fission process enables coincidence counting of fission neutrons and gammas. Comparisons were made to the MCNPX default fission capability which uses ACE table physics and the default fmult fission multiplicity capability. Also, several corrections were made in MCNPX27E and these are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

A more accurate and penetrating method to measure the enrichment and mass of UF6 storage containers using passive neutron self-interrogation

This paper describes an unattended mode neutron measurement that can provide the enrichment of the uranium in UF{sub 6} cylinders. The new passive neutron measurement provides better penetration into the uranium mass than prior gamma-ray enrichment measurement methods. The Passive Neutron Enrichment Monitor (PNEM) provides a new measurement technique that uses passive neutron totals and coincidence counting together with neutron self-interrogation to measure the enrichment in the cylinders. The measurement uses the neutron rates from two detector pods. One of the pods has a bare polyethylene surface next to the cylinder and the other polyethylene surface is covered with Cd to prevent thermal neutrons from returning to the cylinder. The primary neutron source from the enriched UF{sub 6} is the alpha-particle decay from the {sub 234}U that interacts with the fluorine to produce random neutrons. The singles neutron counting rate is dominated by the {sub 234}U neutrons with a minor contribution from the induced fissions in the {sub 235}U. However, the doubles counting rate comes primarily from the induced fissions (i.e., multiplication) in the {sub 235}U in enriched uranium. The PNEM concept makes use of the passive neutrons that are initially produced from the {sub 234}U reactions that track the {sub 235}U enrichment during the enrichment process. The induced fission reactions from the thermal-neutron albedo are all from the {sub 235}U and provide a measurement of the {sub 235}U. The Cd ratio has the desirable feature that all of the thermal-neutron-induced fissions in {sub 235}U are independent of the original neutron source. Thus, the ratio is independent of the uranium age, purity, and prior reactor history.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distinguishing Research Reactor Fuels Using Neutron Multiplicity - 25615

Neutron measurements are one of the reliable means of interrogation of fissile material. Neutron measurements are used for total counting (pure metal fissile samples) or counting coincidence/multiplicity (for impure fissile samples). Various flavors of neutron measurement are used routinely by the IAEA to determine the fissile mass of an unknown sample. The objective of this work is to design an experiment to distinguish the two different fuel types using neutron multiplicity method. The design of experiment is performed using Monte Carlo N- Particle (MCNP) transport code. General Electric (GE) designed 1-MWt pool-type research reactor at UMass Lowell (UMLRR) uses Materials Testing Reactor (MTR) plate-type fuel consisting of 19 full and 2 partial fuel assemblies, controlled by four boron control blades and one regulating control rod. Two different fuel types are available at the UMLRR facility. In 2008, UMass Lowell obtained slightly burnt fuel assemblies from the decommissioned WPI research reactor. The simulation results discussed in this paper show that within the limits of statistical error, the single and double moments for the WPI and UMLRR fuels can be measured. The two fuels have very similar composition and enrichments resulting in very similar neutron multiplicity moments. This implies that neutron multiplicity measurements alone would not be sufficient to distinguish between the two fuel types at low burnups. The change in the observed single-double ratio between each fuel type is less than 6 % which falls below the uncertainty in the efficiency of the JCC71 slab detectors. The neutron signature from low burnup and low enriched uranium fuel are not strong, however, these can be measured under low background and long measurement times. This would be an important consideration in designing the experiments and parallel gamma measurements will also be planned. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of the NPOD3 Detectors in MCNP5 and MCNP6

Researchers performed a series of measurements in May 2012 to characterize the NPOD3 detector systems. The detectors were placed in varying states of disassembly to determine the effect of individual components on detection efficiency. A 4.5 kg α-phase Pu sphere known as the Los Alamos BeRP Ball was used as the SNM source in both a bare configuration and reflected by varying thicknesses of polyethylene. A set of simulations matching the experimental setups were run and the data were compared to the measured data. The total and leakage multiplication and the inferred k values were determined for both the simulations and the measurements. Table 3 shows a comparison of the results from MCNP6 and MCNP5 with the list-mode patch to the measured results. The count rates for the calculated results were obtained by dividing the total line count in the list-mode file (equivalent to the total number of absorptions in the NPOD detectors) by the total run time. The count rates are identical for both codes, and they both produce the same multiplicity and inferred k values regardless of measurement time as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).