Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Leakage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development and benchmarking of transient nodal code SIMULATE5-K neutron kinetics solver

SIMULATE5-K is Studsvik's next generation best estimate transient code. The time dependent diffusion equation is solved with a nodal method consistent with that implemented in the licensed core design code SIMULATE5. Arbitrary number of neutron and delayed neutron precursor groups can be used. For the solution of the spatial problem, the coupling coefficients used to relate the node leakages are found by first converting the time dependent diffusion equation to a static diffusion equation with the use of flux and delayed neutron precursor dynamic frequencies. Once the static-like equations are obtained, the multi-group analytical nodal model is used to obtain the coupling coefficients, expressing the node leakage in terms of adjacent node average fluxes. The coupling coefficients are then inserted into the time dependent nodal balance equation. For the time integration, the time dependent neutron balance equation is solved with the frequency transformation method. The treatment of the temporal dependence yields a fixed source problem which can be solved utilizing the existing fixed-source methodology. The primary purpose of this paper is to describe the neutron kinetics methodology implemented in SIMULATE5-K. The accuracy of the method is demonstrated for a series of well-known, neutronic-only benchmark problems. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of fast and thermal neutron irradiation on Ga-polar and N-polar GaN diodes

Studies of the radiation tolerance and electrical behavior of gallium nitride (GaN) based devices are important for the next generation of high-power and high-voltage electronics that may be subjected to harsh environments such as nuclear reactor and fusion facilities, particle accelerators, and post-denotation environments. Here, in this work, we study the behavior of Ga-polar and N-polar GaN Schottky diodes before and after exposure to fast and thermal + fast neutrons. Temperature-dependent current–voltage (I–V) and circular transmission line method (CTLM) measurements were used to study the electrical characteristics. A strong reduction in reverse leakage current and an increase in differential resistance in forward bias were observed after neutron irradiation. Thermionic emission (TE), Frenkel–Poole (FP) emission, and Fowler–Nordheim (FN) tunneling models were used to explain the forward and reverse I–V characteristics pre- and post-irradiation. The study confirms that Ga-polar and N-polar GaN Schottky diodes exhibit different electrical responses to fast and thermal neutron irradiations. The reverse bias characteristics of N-polar diodes are less affected after the fast neutron irradiation compared to Ga-polar diodes, while in the forward bias region, the electrical behavior after fast and thermal neutron irradiations is similar in Ga-polar and N-polar diodes. The results indicate that the role of orientation should be considered in the design of GaN-based radiation-tolerant electronics.

42 ENGINEERING↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitocans induce lipid flip-flop and permeabilize the membrane to signal apoptosis

Pancratistatin (PST) and narciclasine (NRC) are natural therapeutic agents that exhibit specificity toward the mitochondria of cancerous cells and initiate apoptosis. Unlike traditional cancer therapeutic agents, PST and NRC are effective, targeted, and have limited adverse effects on neighboring healthy, noncancerous cells. Currently, the mechanistic pathway of action for PST and NRC remains elusive, which in part inhibits PST and NRC from becoming efficacious therapeutic alternatives. Herein, we use neutron and x-ray scattering in combination with calcein leakage assays to characterize the effects of PST, NRC, and tamoxifen (TAM) on a biomimetic model membrane. We report an increase in lipid flip-flop half-times (t 1/2 ) (≈12.0%, ≈35.1%, and a decrease of ≈45.7%) with 2 mol percent PST, NRC, and TAM respectively. An increase in bilayer thickness (≈6.3%, ≈7.8%, and ≈7.8%) with 2 mol percent PST, NRC, and TAM, respectively, was also observed. Lastly, increases in membrane leakage (≈31.7%, ≈37.0%, and ≈34.4%) with 2 mol percent PST, NRC, and TAM, respectively, were seen. Considering the maintenance of an asymmetric lipid composition across the outer mitochondrial membrane (OMM) is crucial to eukaryotic cellular homeostasis and survival, our results suggest PST and NRC may play a role in disrupting the native distribution of lipids within the OMM. A possible mechanism of action for PST- and NRC-induced mitochondrial apoptosis is proposed via the redistribution of the native OMM lipid organization and through OMM permeabilization.

59 BASIC BIOLOGICAL SCIENCES↗

Response of Integrated Silicon Microwave pin Diodes to X-ray and Fast-Neutron Irradiation

Here, integrated silicon microwave pin diodes are exposed to 10-keV X-rays up to a dose of 2 Mrad(SiO 2 ) and 14-MeV fast neutrons up to a fluence of 2.2×10 13 cm -2 . Changes in both DC leakage current and small-signal circuit components are examined. Degradation in performance due to total-ionizing dose is shown to be suppressed by non-quasi-static effects during RF operation. Tolerance to displacement damage from fast neutrons is also observed, which is explained using TCAD simulations. Overall, the characterized pin diodes are tolerant to cumulative radiation at levels consistent with space applications such as geosynchronous weather satellites.

42 ENGINEERING↗

Fast flavor instability in hypermassive neutron star disk outflows

Here, we examine the effect of neutrino flavor transformation by the fast flavor instability (FFI) on long-term mass ejection from accretion disks formed after neutron star mergers. Neutrino emission and absorption in the disk set the composition of the disk ejecta, which subsequently undergoes r-process nucleosynthesis upon expansion and cooling. Here we perform 28 time-dependent, axisymmetric, viscous-hydrodynamic simulations of accretion disks around hypermassive neutron stars (HMNSs) of variable lifetime, using a 3-species neutrino leakage scheme for emission and an annular-lightbulb scheme for absorption. We include neutrino flavor transformation due the FFI in a parametric way, by modifying the absorbed neutrino fluxes and temperatures, allowing for flavor mixing at various levels of flavor equilibration, and also in a way that aims to respect the lepton-number preserving symmetry of the neutrino self-interaction Hamiltonian. We find that for a promptly-formed black hole (BH), the FFI lowers the average electron fraction of the disk outflow due to a decrease in neutrino absorption, driven primarily by a drop in electron neutrino/antineutrino flux upon flavor mixing. For a long-lived HMNS, the disk emits more heavy lepton neutrinos and reabsorbs more electron neutrinos than for a BH, with a smaller drop in flux compensated by a higher neutrino temperature upon flavor mixing. The resulting outflow has a broader electron fraction distribution, a more proton-rich peak, and undergoes stronger radiative driving. Disks with intermediate HMNS lifetimes show results that fall in between these two limits. In most cases, the impact of the FFI on the outflow is moderate, with changes in mass ejection, average velocity, and average electron fraction of order ~10%, and changes in the lanthanide/actinide mass fraction of up to a factor ~2.

79 ASTRONOMY AND ASTROPHYSICS↗

Energetic neutrons leaking from the top of the atmosphere.

The energy, angular, and latitude distributions of energetic neutrons (up to 2 GeV) leaking from the top of the atmosphere have been calculated. The results agree with the recent measurement of Preszler, Simnett, and White, whose leakage rates were well above the calculation of Lingenfelter. Since the spectrum of Lingenfelter has served for evaluating the cosmic-ray albedo-neutron decay (CRAND) source of energetic protons in Earth's inner radiation belt, it is suggested that the results reported here be used to reevaluate the CRAND contribution.

Merker, M.↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum information approach to the implementation of a neutron cavity

Abstract Using the quantum information model of dynamical diffraction we consider a neutron cavity composed of two perfect crystal silicon blades capable of containing the neutron wavefunction. We show that the internal confinement of the neutrons through Bragg diffraction can be modelled by a quantum random walk. Furthermore, we introduce a toolbox for modelling crystal imperfections such as surface roughness and defects. Good agreement is found between the simulation and the experimental implementation, where leakage beams are present, modelling of which is impractical with the conventional theory of dynamical diffraction. Analysis of the standing neutron waves is presented in regards to the crystal geometry and parameters; and the conditions required for well-defined bounces are derived. The presented results enable new approaches to studying the setups utilizing neutron confinement, such as the experiments to measure neutron magnetic and electric dipole moments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Radiation damage effects by electrons, protons, and neutrons in Si/Li/ detectors.

The degradation in performance of lithium-compensated silicon nuclear particle detectors induced by irradiation at room temperature with 0.6-MeV and 1.5-MeV electrons, 1.9-MeV protons, and fast neutrons from a plutonium-beryllium source has been investigated. With increasing fluence, the irradiations produced an increase of detector leakage current, noise, capacitance, and a degradation in the performance of the detector as a charged-particle energy spectrometer. Following the irradiations, annealing effects were observed when the detectors were reverse-biased at their recommended operating voltages. Upon removal of bias, a continuous degradation of detector performance characteristics occurred. Detectors which had been damaged by electrons and protons exhibited a stabilization in their characteristics within two weeks after irradiation, whereas detectors damaged by neutrons had a continuous degradation of performance over a period of several months.

Liu, Y. M.↗

Imaging electric field with electrically neutral particles

It used to think that is impossible to determine/measure electric field inside a physically isolated volume, especially inside an electrically shielded space, because a conventional electric-field sensor can only measure electric field at the location of the sensor, and when an electric-field source is screened by conductive materials, no leakage electric field can be detected. For first time, we experimentally demonstrated that electrically neutral particles, neutrons, can be used to measure/image electric field behind a physical barrier. This work enables a new measurement capability that can visualize electric-relevant properties inside a studied sample or detection target for scientific research and engineering applications.

42 ENGINEERING↗

239 Pu R -matrix Analysis and Neutron Multiplicities in the Neutron Energy Region up to a few keVs [Abstract]

The evaluation of 239 Pu neutron resonance parameters coupled to neutron multiplicities $\overline{v}_p$ is of particular importance to investigate the ($\mathcal{n, γf}$) reaction in which a $\mathcal{γ}$-ray emission occurs before the scission of the compound nuclear. This reaction has offered one explanation for the fluctuations in the measured values of $\overline{v}_p$ In this regard, the competition between ($\mathcal{n, γf}$) reaction and the direct fission process can be also included in the R matrix analysis of fission and capture measured data. The goal of this work is the coupled evaluation of the $\mathcal{n}$+ 239 Pu resonance parameters and related neutron multiplicities by ensuring the adoption of thermal neutron constants recently evaluated at the International Atomic Nuclear Energy as well as the recommended (thermal-neutron) induced prompt neutron fission spectrum (PFNS). Moreover, this new set of physical evaluated quantities should also guarantee the agreement for high-leakage solution benchmarks while keeping the good performance of large thermal solution assemblies.

07 ISOTOPE AND RADIATION SOURCES↗

Investigating the Effects of Individual Neutron-Induced Defects in Bipolar Junction Transistors

Here, this study investigates neutron-induced displacement damage in Bipolar Junction Transistors (BJTs) using TCAD models informed by Deep-Level-Transient-Spectroscopy (DLTS) data. These models are calibrated and validated against experimental measurements performed at various neutron fluences. Both npn and pnp transistor configurations are studied to analyze the effects of individual traps on carrier recombination and base leakage currents. In npn transistors, deep traps (0.42 eV from the conduction band) dominate at low voltages, while shallow traps (0.17 eV from the conduction band) become prominent at higher voltages. Conversely, pnp transistors have base leakage current predominantly due to deep-level traps. The study observes a notable trend in trap density versus fluence, characterized by a linear relationship on a log-log scale. These insights into defect evolution under radiation conditions are crucial for optimizing semiconductor device reliability and performance in radiation-prone environments.

42 ENGINEERING↗

r -process nucleosynthesis and kilonovae from hypermassive neutron star post-merger remnants

ABSTRACT We investigate r-process nucleosynthesis and kilonova emission resulting from binary neutron star (BNS) mergers based on a three-dimensional (3D) general-relativistic magnetohydrodynamic (GRMHD) simulation of a hypermassive neutron star (HMNS) remnant. The simulation includes a microphysical finite-temperature equation of state (EOS) and neutrino emission and absorption effects via a leakage scheme. We track the thermodynamic properties of the ejecta using Lagrangian tracer particles and determine its composition using the nuclear reaction network SkyNet. We investigate the impact of neutrinos on the nucleosynthetic yields by varying the neutrino luminosities during post-processing. The ejecta show a broad distribution with respect to their electron fraction Ye, peaking between ∼0.25–0.4 depending on the neutrino luminosity employed. We find that the resulting r-process abundance patterns differ from solar, with no significant production of material beyond the second r-process peak when using luminosities recorded by the tracer particles. We also map the HMNS outflows to the radiation hydrodynamics code SNEC and predict the evolution of the bolometric luminosity as well as broadband light curves of the kilonova. The bolometric light curve peaks on the timescale of a day and the brightest emission is seen in the infrared bands. This is the first direct calculation of the r-process yields and kilonova signal expected from HMNS winds based on 3D GRMHD simulations. For longer-lived remnants, these winds may be the dominant ejecta component producing the kilonova emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗