Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Natural circulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fuel Behavior Implications of Reactor Design Choices in Pressurized Water SMRs

Small pressurized water reactors (PWRs) can feature boron free operation, natural circulation mode, reduced height assemblies and/or long refueling cycles. This paper attempts to explore core design optimization for each of these design evolutions. In consequence, five core design layouts are developed incorporating boron free operation with continuous control rods insertion, natural circulation with low burnup/low power density design, natural circulation with high burnup/low power density design, forced circulation with standard core power density design, and forced circulation with high power density design. These cores’ performance is compared to a standard 4-loop PWR. The design process aims to improve the fuel cycle cost under safety constraints through core design optimization using CASMO4E/SIMULATE3 reactor physics codes and FRAPCON4.1 fuel performance assessment tool. Core modeling assumes standard 17x17 PWR fuel assemblies loaded with low enriched uranium (LEU) up to 5wt% or LEU+ (i.e., below 10wt% enrichment) pellets with gadolinium oxide (Gd2O3) as the burnable poison. Satisfactory core and fuel performances are obtained for all the designed cores under steady state and considered overpower transients. For low power density operation, long cycle lengths are achieved reaching a 2.5- and a 5-year cycles and peak rod-average burnup is pushed to 83 MWd/kgU. Other cycle lengths are maintained at 18 months. Boron free operation exhibits the ability to achieve longer cycle lengths at the cost of higher peaking factors leading to high local power and fuel temperatures which prevents sizable power uprates and is deemed uneconomical. Fuel assembly height reduction allows coolant velocity retrofit which enables higher core power density without violating structural integrity of the fuel assembly. As a result, a core power density of 123 kW/l is reached where total cladding hoop strain becomes the limiting parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling of thermal stratification in outlet plena of SFRs with gallium as a surrogate fluid

Due to its high thermal diffusivity, liquid sodium can develop thermally stratified regions in the hot and cold pools of SFRs under certain off normal operating conditions. The temperature gradients in the fluid give rise to mixed convection flow in which flow velocities result both from pressure gradients and from volume forces induced by density gradients. High thermal diffusivity and low momentum diffusivity leads to reduced thermal mixing and enhanced stratification. Thermal stratification, if not looked carefully in the design, can lead to severe consequences in normal operation with forced coolant circulation and during off-normal natural circulation. The resulting hydraulic and thermal loads can cause the failure modes in structures and components critical for reactor safety. Thermal stratification in the SFR pools can lead to thermal fatigue, which can lead to structural and material failure, or pose serious concerns for the reactor safety. In addition to thermo-structural issues, the reactivity changes are significantly impacted due to density or temperature driven movement of liquid sodium. Temperature changes or gradients in the Upper Instrumentation Structures (UIS) of SFRs can lead to thermal contraction, a case that can lead to positive reactivity insertion after core shut-down. The motivation of this work is to design a scaled down experimental facility which can generate high fidelity data for thermal stratification physics to validate 3-dimensional (3D) Computational Fluid Dynamics (CFD) models. These validated CFD codes can be used to improve the 1-dimensional (1D) system level codes such as SAS4A/SASSYS-1 which are currently not capable of simulating thermal stratification accurately. These improvements in 1D system level SAS4A/SASSYS-1 codes can significantly improve the safety analyses and design of SFRs. The GaTE facility outlet plenum model is designed based on physics based similarities. Thermal stratification physics is governed primarily by the Richardson numbers (Ri). The expected low flow rates during off-normal conditions can lead to a high degree of thermal stratification in the outlet plenum with a corresponding Ri = 530. Therefore, the inlet flow velocities and inlet hydraulic diameter for the gallium coolant entering the test vessel are required to achieve same Ri. The design of test vessel in GaTE facility is finalized to a 1/20. scale outlet plenum height of the ABTR. This design of the test facility will allow the decoupling of the thermal stratification physics at low flow rates with the transient natural circulation. In other words, it will enable effective control to study thermal stratification at very low flow rates. Numerical studies are conducted with a 3D CFD code to examine the thermal behavior of the selected test design. Simulation results show that thermal gradients are present only in the vertical or axial direction which are similar to the behavior reported in previous studies on full scale SFR models. Future work will involve the experimental studies using the GaTE facility with the high fidelity instrumentation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DRACS thermal performance evaluation for FHR

Direct Reactor Auxiliary Cooling System (DRACS) is a passive decay heat removal system proposed for the Fluoride-salt-cooled High-temperature Reactor (FHR) that combines coated particle fuel and a graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops, relying completely on buoyancy as the driving force. These loops are coupled through two heat exchangers, namely, the DRACS Heat Exchanger and the Natural Draft Heat Exchanger. In addition, a fluidic diode is employed to minimize the parasitic flow into the DRACS primary loop and correspondingly the heat loss to the DRACS during normal operation of the reactor, and to keep the DRACS ready for activation, if needed, during accidents. To help with the design and thermal performance evaluation of the DRACS, a computer code using MATLAB has been developed. This code is based on a one-dimensional formulation and its principle is to solve the energy balance and integral momentum equations. By discretizing the DRACS system in the axial direction, a bulk mean temperature is assumed for each mesh cell. The temperatures of all the cells, as well as the mass flow rates in the DRACS loops, are predicted by solving the governing equations that are obtained by integrating the energy conservation equation over each cell and integrating the momentum conservation equation over each of the DRACS loops. In addition, an intermediate heat transfer loop equipped with a pump has also been modeled in the code. This enables the study of flow reversal phenomenon in the DRACS primary loop, associated with the pump trip process. Experimental data from a High-Temperature DRACS Test Facility (HTDF) are not available yet to benchmark the code. A preliminary code validation is performed by using natural circulation experimental data available in the literature, which are as closely relevant as possible. The code is subsequently applied to the HTDF that is under construction at the Ohio State University.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HI-STORM Overpack and MPC-32 Thermal-Hydraulic Model with MOOSE Framework

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a MOOSE thermal model of the MPC-32 canister and HI-STORM overpack

Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Studies of NGNP Reactor Cavity Cooling System With Water

This project will investigate the flow behavior that can occur in the reactor cavity cooling system (RCCS) with water coolant under the passive cooling-mode of operation. The team will conduct separate-effects tests and develop associated scaling analyses, and provide system-level phenomenological and computational models that describe key flow phenomena during RCCS operation, from forced to natural circulation, single-phase flow and two-phase flow and flashing. The project consists of the following tasks: Task 1. Conduct separate-effects, single-phase flow experiments and develop scaling analyses for comparison to system-level computational modeling for the RCCS standpipe design. A transition from forced to natural convection cooling occurs in the standpipe under accident conditions. These tests will measure global flow behavior and local flow velocities, as well as develop instrumentation for use in larger scale tests, thereby providing proper flow distribution among standpipes for decay heat removal. Task 2. Conduct separate-effects experiments for the RCCS standpipe design as two-phase flashing occurs and flow develops. As natural circulation cooling continues without an ultimate heat sink, water within the system will heat to temperatures approaching saturation , at which point two-phase flashing and flow will begin. The focus is to develop a phenomenological model from these tests that will describe the flashing and flow stability phenomena. In addition, one could determine the efficiency of phase separation in the RCCS storage tank as the two-phase flashing phenomena ensues and the storage tank vents the steam produced. Task 3. Develop a system-level computational model that will describe the overall RCCS behavior as it transitions from forced flow to natural circulation and eventual two-phase flow in the passive cooling-mode of operation. This modeling can then be used to test the phenomenological models developed as a function of scale.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A hybrid porous model for full reactor core scale CFD investigation of a prismatic HTGR

Three-dimensional (3-D) Computational Fluid Dynamics (CFD) analysis of a whole nuclear reactor core is a tremendous challenge due to the large geometric volume and complex structures. Here, this research presents a hybrid porous (HP) model to simplify a prismatic High Temperature Gas-cooled Reactor (HTGR) core, so 3-D CFD investigation can be performed on a full reactor core scale. In the HP model, the prototypic small coolant channels in the nuclear fuel blocks are lumped together to form multiple equivalent large coolant channels, and then the porous medium flow model is applied to each of them. Therefore, heat transfer in fuel blocks is computed by a hybrid combination of solid energy and porous flow energy equations. The similarity between the HP model and prototypic model is achieved by deriving the porous flow permeability, inertial resistance factor, and artificial thermophysical properties. Compared with the widely used whole porous (WP) flow model, the HP model preserves more realistic geometric structures, and therefore more accurate physical processes. The General Atomics' Modular High Temperature Gas-cooled Reactor (MHTGR) design was chosen as a prototype to demonstrate the methodology. Simulations were performed using the prototypic CFD model and HP model at steady-state forced circulation, steady-state natural circulation, and transient conditions that correspond to normal operation, extended period of pressurized cool down, and short-term transients after reactor shutdown, respectively. The comparison shows good agreement between the HP model and prototypic model in the maximum fuel temperature, average solid temperature, and helium flow rate, which demonstrates the potential applicability of the HP model for a full reactor core scale simulation in the future. As a benefit, the HP model reduces the mesh quantity by a factor of 50 from a prototypic model. Correspondingly, the computation time was reduced by a factor of at least 30.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of numerical models were developed in parallel to the experimental work. RELAP5-3D models were developed for the salt-cooled PB-AHTR, and for the simulat fluid CIET natural circulation experimental loop. These models are to be validated by the data collected from CIET. COMSOL finite element models were used to predict the temperature and fluid flow distribution in the annular pebble bed core; they were instrumental for design of SETs, and they can be used for code-to-code comparisons with RELAP5-3D. A number of other small SETs, and numerical models were constructed, as needed, in support of this work. The experiments were designed, constructed and performed to meet CAES quality assurance requirements for test planning, implementation, and documentation; equipment calibration and documentation, procurement document control; training and personnel qualification; analysis/modeling software verification and validation; data acquisition/collection and analysis; and peer review.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ESBWR enhanced flow distribution with optimized orificing and related fuel cycle performance

The Economic Simplified Boiling Water Reactor (ESBWR) is GEH's latest Generation III+ reactor design with natural circulation coolant flow and passive safety features. Reliance on natural circulation as the sole means of core coolant driving force results in increased power-to-flow ratio and places increased importance on the efficient distribution of core flow in order to achieve optimum thermal margins and improved fuel cycle efficiency. In addition, the large core size of the ESBWR, containing 1132 bundles, greatly benefits from a more targeted distribution of flow, directing a higher fraction of flow to high power bundles in the 'ring of fire' region of typical BWR loading patterns and a lower fraction of flow to low power bundles on and near the core periphery. Desirable flow distributions can be achieved by modifying the hydraulic resistance of the inlet orifices to preferentially force flow to the targeted region. The inlet orifice is a feature that is incorporated into the fuel support piece of a typical BWR design. The majority of existing forced circulation BWR's rely on only two orifice types - a peripheral orifice located along the outermost row and a central orifice in all other locations. A more optimum distribution of core flow is achievable with the introduction of multiple inlet orifice types. Multi-zone orifice layouts comprised of two, three and four types have been evaluated for the ESBWR. An efficient radial distribution of flow can have a direct beneficial effect on the Minimum Critical Power Ratio (MCPR). An improved multi-zone orifice layout in the ESBWR has the potential of significantly increasing active flow in high power bundles. On average, this flow increase corresponds to a noteworthy MCPR improvement. Additional MCPR margin may be used to enhance operating flexibility and to achieve reduced fuel cycle costs over the plant lifetime. Combined with GNF's latest high performance fuel design for the ESBWR, GNF2E, and improved loading pattern concepts, fuel cycle costs have been shown to be very competitive. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preservation of FFTF Data Related to Passive Safety Testing

One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety experience to a large-size LMR and obtain data for validating design analysis computer codes, and 3) to develop and test passive safety enhancements that might be used for future LMRs. These tests were designed to provide data sufficient to allow separation of fuel temperature effects from structural temperature effects. The data developed through this testing program were used to verify the predictive capability of passive safety analysis methods as well as provide a data base for calibrating design tools such as the SASSYS/SAS4A codes. These tests were instrumental in improving understanding of reactivity feedback mechanisms in LMRs and demonstrating passive safety margins available in an LMR. Knowledge preservation at the FFTF is focused on the areas of design, construction, startup, and operation of the reactor. This information may be of potential use for international exchanges with other LMR programs around the world. This information provides the basis for creating benchmarks for validating and testing large scale computer programs. All information preserved to date is now being stored and categorized consistent with the IAEA international standardized taxonomy. The test results information exists in several different formats depending upon the final stage of the test evaluation. Over 100 documents relevant to passive safety testing have been identified and are being recovered, scanned, and catalogued. Attempts to recover plant data tapes are also in progress. Documents related to passive safety testing are now being categorized consistent with internationally agreed upon IAEA standards. Documents are being converted to electronic format compatible with a general search engine being developed by INL. The data from the FFTF passive safety tests provides experimental verification of structural reactivity effects that should be very useful to innovative designers seeking to optimize passive safety in the design of new LMRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Buoyancy-driven air flow within plenum-to-plenum facility down-comer channel

Reliable measurements of thermal and velocity fields were experimentally investigated under different natural circulation intensities in a dual channel facility designed and developed with a representative geometry of prismatic modular reactor core. Experiments were conducted under steady state conditions to obtain statistically stationary time series signals of temperature and velocity. Insignificant radial temperature variation was observed along the down-comer channel implying that the majority of supplied heat is removed through the upper plenum. Velocity results obtained emphasize the delicate nature of natural circulation phenomena in terms of flow destabilization, and recirculation penetration length. Observed air velocity distribution reveals that downward velocity is proportional to the extent of cooling applied to the setup. The calculated values of the dimensionless group Froude number ( Fr ) in the range of 2 to 10 indicate that air is dominated by momentum and is exiting the channel as a jet. Quantification of turbulent intensities implies that flow destabilization is noticeable along the down-comer channel particularly for the case of high cooling intensity. For 5 °C cooling water temperature, turbulent intensity ($v$ rms / $v$) peaks at the mid-channel (z/L = 0.5) reaching a value of 0.5. This value of turbulent intensity is much higher than the inlet (z/L = 0.96) and outlet (z/L = 0.04) turbulent intensities of 0.2 and 0.06 respectively. This destabilization is because of the flow reversal and heat conduction effects through stainless steel flanges connecting both channels. In conclusion, current results provide detailed velocity and temperature variation which can be useful for validating computational fluid dynamics codes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal-Hydraulic-Mechanical Modeling and Simulation of Sodium-Potassium–Cooled MARVEL Microreactor Core

The U.S. Department of Energy's Microreactor Program, with Idaho National Laboratory's development of a nuclear microreactor applications test bed named MARVEL, aims to support R&D for the deployment of small, transportable reactors across civilian, industrial, and defense sectors. The MARVEL microreactor, an 85-kWth thermal fission reactor, incorporates TRIGA nuclear fuel and a sodium-potassium eutectic as its primary coolant, designed for safety and efficiency, with natural circulation eliminating the risk of critical heat flux conditions. The reliance on natural circulation for primary cooling means the reactor avoids using fuel spacers to minimize core pressure drop, which could disrupt the primary coolant's natural flow. However, the reactor core’s tight P/D ratio of 1.05, in the absence of fuel spacers, could pose a risk of fuel rod contact and increased peak cladding temperatures. To ensure the reactor safety, this study conducted computational modeling and simulations to investigate the reactor's thermal-hydraulic-mechanical characteristics, including the reactor core heat transfer coefficients, the potential for rod-to-rod contact, and assessed its impact on peak cladding temperature and overall reactor safety. The computational analyses of the MARVEL microreactor core revealed that the thermal deformation of fuel rods under worst-case scenario may lead to the fuel rod contact, but the peak cladding temperatures will remain significantly lower than the safety criteria, ensuring the safety operation reactor without fuel spacers under normal operating conditions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SAM Code Validation using the Compact Integral Effects Test (CIET) Experimental Data

The primary objective of this study is to validate the system analysis code, SAM, using experimental data from the Compact Integral Effects Test (CIET) facility. The System Analysis Module (SAM) is an advanced and modern system analysis tool being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. Originally aiming at supporting sodium fast reactor (SFR) design, it is now extended to cover other non-light water reactor (non-LWR) concepts, such as high-temperature gas-cooled reactor (HTGR) designs, molten salt-fueled, and molten salt-cooled reactor designs. To support SAM code development for the wide range of non-LWR applications, it is of paramount importance to validate the code against experiments relevant to these reactor concepts. The Compact Integral Effects Test (CIET) facility, which was designed to reproduce the thermal-hydraulics response of fluoride salt-cooled high-temperature reactors (FHR) under both forced- and natural-circulation conditions, has been identified and selected as one of benchmark test facilities for SAM code validation. Among available CIET experiments, three sets of them with distinctive characteristics were selected for SAM code validation purpose. The three sets experiments are: 1) Power step change transient tests; 2) DHX-DRACS natural circulation tests; and 3) heater frequency response tests. For all tests, steady-state or transient, SAM-predicted results show very good agreement with experimental data. The successful validation of SAM against these selected CIET experiments demonstrates that the computer code is well suited for thermal-hydraulics analysis of FHR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Code validation of a scaled-down DRACS model in RELAP5/SCDAPSIM/MOD 4.0

Direct Reactor Auxiliary Cooling System (DRACS) is a passive safety system proposed for Fluoride-salt-cooled High-temperature Reactors (FHRs). Additionally, benchmark study of decay heat removal capability of DRACS by natural circulation is critical for FHR safety analysis. Two scaled-down test facilities, a low-temperature DRACS test facility (LTDF) and a high-temperature DRACS test facility (HTDF), were designed following a scaling analysis and constructed to investigate thermal performance and heat removal capability of the DRACS. The LTDF uses water as a surrogate coolant for both the primary and DRACS loops. Two transient scenarios were carried out in the LTDF, namely, DRACS startup and primary coolant pump trip. In both of the scenarios, the experimental results demonstrate sufficient heat removal capabilities of the DRACS with natural circulations established in the system. These two scenarios were simulated using RELAP5/SCDASIM/MOD4.0 code and the code simulation results show good agreement with the LTDF experimental data. For the HTDF, molten salts FLiNaK and KF-ZrF4 are used respectively as the primary coolant and DRACS coolant. Thermodynamic and transport properties of FLiNaK and KF-ZrF4 were implemented into RELAP5/SCDAPSIM/MOD 4.0. Lastly, simulations of transient scenarios in the HTDF were also performed and the code results will be compared with the HTDF experimental data once available

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TRACE Analysis of the STS Target Flow Loop Conceptual Design

This report documents the efforts to model the conceptual design of the STS natural circulation flow loop using TRACE. The results, summarized in Section 2.1, support the conclusion that the conceptual STS natural circulation flow loop design provides sufficient cooling of the tungsten target and exhibits predictable flow behavior, provided that certain design features and/or operating conditions are used. In particular: A sufficient initial liquid volume fraction is required to avoid dryout of the target flow channels; Inclusion of a pressurizer or bellows volume at the top of the loop is recommended and is capable of achieving steady, non-oscillatory flow and temperature conditions at sufficiently high loop pressure. Section 1 provides a detailed description of the geometry and assumptions used in the model, and Section 2 presents the results for the current flow loop design as well as some investigation of potential design modifications with the goal of enhancing the thermal hydraulic stability of the loop.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗