Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Self-learning Monte Carlo method and cumulative update in fermion systems

In this study, we develop the self-learning Monte Carlo (SLMC) method, a general-purpose numerical method recently introduced to simulate many-body systems, for studying interacting fermion systems. Our method uses a highly efficient update algorithm, which we design and dub “cumulative update”, to generate new candidate configurations in the Markov chain based on a self-learned bosonic effective model. From a general analysis and a numerical study of the double exchange model as an example, we find that the SLMC with cumulative update drastically reduces the computational cost of the simulation, while remaining statistically exact. Remarkably, its computational complexity is far less than the conventional algorithm with local updates.

36 MATERIALS SCIENCE↗

CONTINUOUS-ENERGY MONTE CARLO METHODS FOR CALCULATING GENERALIZED RESPONSE SENSITIVITIES USING TSUNAMI-3D

This work introduces a new approach for calculating sensitivity coefficients for generalized neutronic responses to nuclear data uncertainties using continuous-energy Monte Carlo methods. The approach presented in this paper, known as the GEAR-MC method, allows for the calculation of generalized sensitivity coefficients for multiple responses in a single Monte Carlo calculation with no nuclear data perturbations or knowledge of nuclear covariance data. The theory behind the GEAR-MC method is presented here, and proof of principle is demonstrated by using the GEAR-MC method to calculate sensitivity coefficients for responses in several 3D, continuous-energy Monte Carlo applications.

CLUTCH↗

Shuttle vertical fin flowfield by the direct simulation Monte Carlo method

The flow properties in a model flowfield, simulating the shuttle vertical fin, determined using the Direct Simulation Monte Carlo method. The case analyzed corresponds to an orbit height of 225 km with the freestream velocity vector orthogonal to the fin surface. Contour plots of the flowfield distributions of density, temperature, velocity and flow angle are presented. The results also include mean molecular collision frequency (which reaches 1/60 sec near the surface), collision frequency density (approaches 7 x 10 to the 18/cu m sec at the surface) and the mean free path (19 m at the surface).

Hueser, J. E.↗

Statistical error of reactor calculations by the Monte Carlo method

Algorithms for calculating the statistical error with allowance for intergenerational correlations are described. The algorithms are constructed on the basis of statistical analysis of the results of computations by the Monte Carlo method. As a result, simple rules for choosing the parameters of the computational techniques, such as the number of simulated generations necessary for attaining the required accuracy and the number of first skipped generations, are elaborated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isospin-projected nuclear level densities by the shell model Monte Carlo method

We have developed an efficient isospin projection method in the shell model Monte Carlo approach for isospin-conserving Hamiltonians. For isoscalar observables this method has the advantage of being exact sample by sample. It allows us to take into account the proper isospin dependence of the nuclear interaction, thus avoiding a sign problem that such an interaction introduces in unprojected calculations. We apply the method to calculate the isospin dependence of level densities in the complete pf+g{sub 9/2} shell. We find that isospin-dependent corrections to the total level density are particularly important for N{approx}Z nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lowest-order relativistic corrections of helium computed using Monte Carlo methods

We have calculated the lowest-order relativistic effects for the three lowest states of the helium atom with symmetry {sup 1}S, {sup 1}P, {sup 1}D, {sup 3}S, {sup 3}P, and {sup 3}D using variational Monte Carlo methods and compact, explicitly correlated trial wave functions. Our values are in good agreement with the best results in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of a V{sub 15} magnetic molecular nanocluster by the Monte Carlo method

Exchange interactions in a V{sub 15} magnetic molecular nanocluster are considered, and the process of magnetization reversal for various values of the set of exchange constants is analyzed by the Monte Carlo method. It is shown that the best agreement between the field dependence of susceptibility and experimental results is observed for the following set of exchange interaction constants in a V{sub 15} magnetic molecular nanocluster: J = 500 K, J Prime = 150 K, J Double-Prime = 225 K, J{sub 1} = 50 K, and J{sub 2} = 50 K. It is observed for the first time that, in a strong magnetic field, for each of the three transitions from low-spin to high-spin states, the heat capacity exhibits two closely spaced maxima.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum Monte Carlo method for pairing phenomena: Supercounterfluid of two-species Bose gases in optical lattices

We study the supercounterfluid (SCF) states in the two-component hard-core Bose-Hubbard model on a square lattice, using the quantum Monte Carlo method based on the worm (directed-loop) algorithm. Since the SCF state is a state of a pair condensation characterized by <a{sup {dagger}b}>{ne}0,<a>=0, and <b>=0, where a and b are the order parameters of the two components, it is important to study behaviors of the pair-correlation function <a{sub i}b{sub i}{sup {dagger}a}{sub j}{sup {dagger}b}{sub j}>. For this purpose, we propose a choice of the worm head for calculating the pair-correlation function. From this pair correlation, we confirm the Kosterlitz-Thouless character of the SCF phase. The simulation efficiency is also improved in the SCF phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

60 APPLIED LIFE SCIENCES↗

Introduction to the Monte Carlo Method [Slides]

The goal here is to introduce you to the Monte Carlo (MC) method. MC is a very powerful simulation technique. Very simple examples will be used. Potential MC users have diverse backgrounds, but you should see from the examples how the method could be applied to your field of study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of vibrational-translational energy transfer using the direct simulation Monte Carlo method

A new model is proposed for energy transfer between the vibrational and translational modes for use in the direct simulation Monte Carlo method (DSMC). The model modifies the Landau-Teller theory for a harmonic oscillator and the rate transition is related to an experimental correlation for the vibrational relaxation time. Assessment of the model is made with respect to three different computations: relaxation in a heat bath, a one-dimensional shock wave, and hypersonic flow over a two-dimensional wedge. These studies verify that the model achieves detailed balance, and excellent agreement with experimental data is obtained in the shock wave calculation. The wedge flow computation reveals that the usual phenomenological method for simulating vibrational nonequilibrium in the DSMC technique predicts much higher vibrational temperatures in the wake region.

Boyd, Iain D.↗

Nuclear reactor transient analysis via a quasi-static kinetics Monte Carlo method

The predictor-corrector quasi-static (PCQS) method is applied to the Monte Carlo (MC) calculation for reactor transient analysis. To solve the transient fixed-source problem of the PCQS method, fission source iteration is used and a linear approximation of fission source distributions during a macro-time step is introduced to provide delayed neutron source. The conventional particle-tracking procedure is modified to solve the transient fixed-source problem via MC calculation. The PCQS method with MC calculation is compared with the direct time-dependent method of characteristics (MOC) on a TWIGL two-group problem for verification of the computer code. Then, the results on a continuous-energy problem are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modification of the Monte Carlo method for calculation of the influence of unknown placement of solid radioactive waste on the uncertainty of dose fields at different overall container dimensions

An approach to estimating the uncertainty of initial data in calculations by the Monte Carlo method is considered. The relative geometrical position of parts of the analyzed system is assumed to be unknown. The influence of different approximations in the description of the geometrical shape of system objects is studied. The effect of unknown location and approximate shape description of solid radioactive waste in the container on the magnitude of dose fields is considered for photon transport problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of the Monte Carlo method for spectrometer calibration to determine the surface activity of radionuclides deposited on the ground

The results of efficiency calibration and verification of the in situ method with application of a handheld spectrometer with high-purity germanium detector are presented. The conducted studies show that the calibration of spectrometer efficiency with the use of the Monte Carlo method can be applied for measurement of the surface activity of radionuclides deposited on the ground with an uncertainty of not more than 22%.

07 ISOTOPE AND RADIATION SOURCES↗

A Monte-Carlo method for Coulomb collisions in moderately coupled plasmas

Here, we introduce a new approach for coupling cumulative and single-scattering distributions, extending Monte Carlo methods for Coulomb collisions in weakly coupled plasmas into the moderately coupled regime. Using time steps typical of cumulative-scattering methods, we show that this approach not only recovers leading-order corrections proportional to the inverse Coulomb logarithm but also solves the full Boltzmann collision integral. A key feature of the method is its simplicity: it can be integrated into cumulative-scattering methods for weakly coupled plasmas with only ~ 10 additional lines of code.

Boltzmann collision integral↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-569: Neutron Shielding Calculation Using Analytical and Multi-Monte Carlo Method for Proton Therapy Facility

Purpose: To evaluate the shielding wall design to protect patients, staff and member of the general public for secondary neutron using a simply analytic solution, multi-Monte Carlo code MCNPX, ANISN and FLUKA. Methods: An analytical and multi-Monte Carlo method were calculated for proton facility (Sumitomo Heavy Industry Ltd.) at Samsung Medical Center in Korea. The NCRP-144 analytical evaluation methods, which produced conservative estimates on the dose equivalent values for the shielding, were used for analytical evaluations. Then, the radiation transport was simulated with the multi-Monte Carlo code. The neutron dose at evaluation point is got by the value using the production of the simulation value and the neutron dose coefficient introduced in ICRP-74. Results: The evaluation points of accelerator control room and control room entrance are mainly influenced by the point of the proton beam loss. So the neutron dose equivalent of accelerator control room for evaluation point is 0.651, 1.530, 0.912, 0.943 mSv/yr and the entrance of cyclotron room is 0.465, 0.790, 0.522, 0.453 mSv/yr with calculation by the method of NCRP-144 formalism, ANISN, FLUKA and MCNP, respectively. The most of Result of MCNPX and FLUKA using the complicated geometry showed smaller values than Result of ANISN. Conclusion: The neutron shielding for a proton therapy facility has been evaluated by the analytic model and multi-Monte Carlo methods. We confirmed that the setting of shielding was located in well accessible area to people when the proton facility is operated.

61 RADIATION PROTECTION AND DOSIMETRY↗

A derivation and scalable implementation of the synchronous parallel kinetic Monte Carlo method for simulating long-time dynamics

Kinetic Monte Carlo (KMC) simulations are used to study long-time dynamics of a wide variety of systems. Unfortunately, the conventional KMC algorithm is not scalable to larger systems, since its time scale is inversely proportional to the simulated system size. A promising approach to resolving this issue is the synchronous parallel KMC (SPKMC) algorithm, which makes the time scale size-independent. This paper introduces a formal derivation of the SPKMC algorithm based on local transition-state and time-dependent Hartree approximations, as well as its scalable parallel implementation based on a dual linked-list cell method. The resulting algorithm has achieved a weak-scaling parallel efficiency of 0.935 on 1024 Intel Xeon processors for simulating biological electron transfer dynamics in a 4.2 billion-heme system, as well as decent strong-scaling parallel efficiency. The parallel code has been used to simulate a lattice of cytochrome complexes on a bacterial-membrane nanowire, and it is broadly applicable to other problems such as computational synthesis of new materials.

97 MATHEMATICS AND COMPUTING↗