Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Models, Anatomic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

TEA Modeling to Quantify Economic Implications for Biorefinery Processing of Isolated Anatomical Fractions of Corn Stover

The Feedstock-Conversion Interface Consortium (FCIC; https://www.energy.gov/sites/prod/files/2020/01/f70/beto-fcic-overview-web.pdf), a collaboration of nine national laboratory partners, seeks to understand impacts of feedstock attributes on biorefinery performance. It is hypothesized that different individual anatomical fractions of corn stover vary in composition and recalcitrance, such that processing each fraction on its own through dedicated campaigns may enable better biorefinery economics overall relative to processing the whole stover material. This presentation focuses on techno-economic analysis (TEA) modeling to quantify the yield and cost ramifications for processing isolated anatomical fractions of corn stover through a low-temperature conversion biorefinery, reflecting a biochemical processing pathway consisting of biomass deconstruction through pretreatment and enzymatic hydrolysis, sugar fermentation and upgrading to hydrocarbon fuels, and lignin upgrading to value-added coproducts. Commercial-scale process simulation and economic evaluation leveraged experimental and analytical data from FCIC researchers for conversion of whole corn stover plus three individual anatomical fractions (cobs, husks, and stalks) across key steps of the conversion process. Our assessment found encouraging potential for biorefinery economic gains that may be achieved through this approach. TEA results indicated fuel yields varying from 29-44 gallons gasoline equivalent (GGE)/dry ton for the individual anatomical fractions compared to whole stover at 34 GGE/ton, equating to minimum fuel selling prices (MFSPs) between $6.37-$10.18/GGE for the fractions versus $8.76/GGE for whole stover (when lignin is burned), or $9.15-$15.19/GGE for the fractions versus $13.11/GGE for whole stover (when lignin is upgraded to coproducts, based on current experimental performance levels). Cobs and husks demonstrated the ability to achieve the highest fuel yields and lowest MFSPs, outperforming whole stover, while stalks led to the opposite result, as a composite reflection of compositional differences and process convertibility. Notably, even when taking the weighted average of the results reflecting each anatomical fraction weighted by its corresponding makeup of corn stover, this feasibility TEA screening supports feedstock cost allowances on the order of roughly $22-$29/ton as may reflect accommodating additional biomass fractionation equipment during feedstock pre-processing upstream of the conversion biorefinery gate to separate corn stover into such constituent fractions. Or viewed differently, the weighted average MFSP for the fractions was found to be $0.31-$0.32/GGE lower than the MFSP for the whole stover basis across either lignin scenario, when maintaining a fixed biomass feedstock cost. These findings highlight favorable implications for biorefinery economics as may be achieved by moving to a staged campaign approach for processing different corn stover fractions sequentially. Further opportunities exist for future work to fill in data gaps for remaining anatomical constituents (e.g. leaves) that were not included in the initial experimental studies, though are expected to maintain similar trends.

biochemical processing pathway↗

An Accurate and Dynamic Computer Graphics Muscle Model

A computer based musculo-skeletal model was developed at the University in the departments of Mechanical and Biomedical Engineering. This model accurately represents human shoulder kinematics. The result of this model is the graphical display of bones moving through an appropriate range of motion based on inputs of EMGs and external forces. The need existed to incorporate a geometric muscle model in the larger musculo-skeletal model. Previous muscle models did not accurately represent muscle geometries, nor did they account for the kinematics of tendons. This thesis covers the creation of a new muscle model for use in the above musculo-skeletal model. This muscle model was based on anatomical data from the Visible Human Project (VHP) cadaver study. Two-dimensional digital images from the VHP were analyzed and reconstructed to recreate the three-dimensional muscle geometries. The recreated geometries were smoothed, reduced, and sliced to form data files defining the surfaces of each muscle. The muscle modeling function opened these files during run-time and recreated the muscle surface. The modeling function applied constant volume limitations to the muscle and constant geometry limitations to the tendons.

Levine, David Asher↗

Flow resistance of phloem sieve plates revisited using an experimental model

Sieve plate resistance has been identified as the key to understanding the efficiency of phloem transport of carbohydrates in trees. These plates with small holes connecting sieve tubes are responsible for the largest resistance to flow in the phloem. Their structure determines how fast sugars can be transported through the phloem with certain pressure differences and what the limits for phloem transport in different plants are. Because experiments with the phloem are very challenging, our understanding of sieve plate resistance is mostly based on anatomical studies and hydrodynamic modeling of flow through sieve plates. These models calculate the resistance of the entire sieve tube–sieve plate system using the Hagen–Poiseuille flow resistance for the sieve cell lumen and a combination of the Hagen–Poiseuille resistance and Sampson flow resistance through the sieve pores. The resistance of the entire sieve plate is calculated by summing the Hagen–Poiseuille and Sampson flow resistances of each pore. To test the validity of this model formulation, an experimental model with aspect parameters similar to phloem sieve tubes was built using polyvinyl chloride (PVC) piping and plastic straws of different diameters and lengths. This system was used to measure flow rates and calculate flow resistance at Reynolds numbers 0.5–300. The results suggest that the current models may significantly overestimate the flow resistance caused by sieve plates and that the resistance might be better described by formulations used for perforated plates.

54 ENVIRONMENTAL SCIENCES↗

RSPECT: A PROSPECT-based model incorporating the real structure of rice leaves

Radiative transfer models (RTMs) describe how light is absorbed, scattered, and transmitted within leaves by simulating mechanistic light propagation processes. The PROSPECT model is based on measurable parameters (the leaf biochemical content) and a non-measurable parameter (the leaf anatomical structure represented by the leaf structure parameter (N)). The effect of N on the optical properties of leaves has been investigated through a number of local and global sensitivity analyses. Other studies have directly evaluated the effect of the leaf anatomical structure on spectral reflectance, particularly in the near infrared region. However, the relationship between N and the anatomical structure is unclear. Here, in this study, we leveraged eLeaf, a ray tracing-based 3D rice leaf simulator, to establish relationships between leaf anatomical features and spectral properties, enabling us to replace N in the PROSPECT-4 model with measurable leaf anatomical parameters and develop the RSPECT model. The leaf thickness at minor vein, leaf thickness at bulliform cells, mesophyll thickness at minor vein, and distance between two minor veins could be used to predict N effectively. The RSPECT model achieved spectral simulation accuracy comparable to PROSPECT-4 and was more suitable for parameter inversion of the physical and chemical properties of rice leaves, with relative root mean square errors of 7.4% for chlorophyll content, 5.6% for equivalent water thickness, and 7.5% for dry matter content. In conclusion, RSPECT improves radiative transfer modeling by integrating measurable anatomical features and provides a framework for extending this approach to other vegetation types.

hyperspectral↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

Leaf cell wall properties and stomatal density influence oxygen isotope enrichment of leaf water

Measurements of oxygen isotope enrichment of leaf water above source water (Δ 18 O LW ) can improve our understanding of the interaction between leaf anatomy and physiology on leaf water transport. Models have been developed to predict Δ 18 O LW such as the string-of-lakes model, which describes the mixing of leaf water pools, and the Péclet effect model, which incorporates transpiration rate and the mixing length between unenriched xylem and enriched mesophyll water in the mesophyll (L m ) or veins (L v ). Here, in this work, we compare measurements and models of Δ 18 O LW on two cell wall composition mutants grown under two light intensities and relative humidities to evaluate cell wall properties on leaf water transport. In maize (Zea mays), the compromised ultrastructure of the suberin lamellae in the bundle sheath of the ALIPHATIC SUBERIN FERULOYL TRANSFERASE mutant (Zmasft) reduced barriers to apoplastic water movement, resulting in higher E and, potentially, L v and, consequently, lower Δ 18 O LW . The difference in Δ 18 O LW in cellulose synthase-like F6 (CslF6) mutants and wild-type of rice (Oryza sativa) grown under two light intensities co-varied with stomatal density. These results show that cell wall composition and stomatal density influence Δ 18 O LW and that stable isotopes can facilitate the development of a physiologically and anatomically explicit water transport model.

59 BASIC BIOLOGICAL SCIENCES↗

Mass Transport Limitations and Kinetic Consequences of Corn Stover Deacetylation

Alkaline pretreatment of herbaceous feedstocks such as corn stover prior to mechanical refining and enzymatic saccharification improves downstream sugar yields by removing acetyl moieties from hemicellulose. However, the relationship between transport phenomena and deacetylation kinetics is virtually unknown for such feedstocks and this pretreatment process. Here, we report the development of an experimentally validated reaction–diffusion model for the deacetylation of corn stover. A tissue-specific transport model is used to estimate transport-independent kinetic rate constants for the reactive extraction of acetate, hemicellulose and lignin from corn stover under representative alkaline conditions (5–7 g L -1 NaOH, 10 wt% solids loadings) and at low to mild temperatures (4–70°C) selected to attenuate individual component extraction rates under differential kinetic regimes. The underlying transport model is based on microstructural characteristics of corn stover derived from statistically meaningful geometric particle and pore measurements. These physical descriptors are incorporated into distinct particle models of the three major anatomical fractions (cobs, husks and stalks) alongside an unsorted, aggregate corn stover particle, capturing average Feret lengths of 917–1239 μm and length-to-width aspect ratios of 1.8–2.9 for this highly heterogeneous feedstock. Individual reaction–diffusion models and their resulting particle model ensembles are used to validate and predict anatomically-specific and bulk feedstock performance under kinetic-controlled vs. diffusion-controlled regimes. In general, deacetylation kinetics and mass transfer processes are predicted to compete on similar time and length scales, emphasizing the significance of intraparticle transport phenomena. Critically, we predict that typical corn stover particles as small as ~2.3 mm in length are entirely diffusion-limited for acetate extraction, with experimental effectiveness factors calculated to be 0.50 for such processes. Debilitatingly low effectiveness factors of 0.021–0.054 are uncovered for cobs—implying that intraparticle mass transfer resistances may impair observable kinetic measurements of this anatomical fraction by up to 98%. These first-reported quantitative maps of reaction vs. diffusion control link fundamental insights into corn stover anatomy, biopolymer composition, practical size reduction thresholds and their kinetic consequences. These results offer a guidepost for industrial deacetylation reactor design, scale-up and feedstock selection, further establishing deacetylation as a viable biorefinery pretreatment for the conversion of lignocellulosics into value-added fuels and chemicals.

09 BIOMASS FUELS↗

Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images

Purpose: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. Methods: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose–volume histogram parameters and 3D gamma criteria. Results: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. Conclusions: This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.

60 APPLIED LIFE SCIENCES↗

Neurophysiological model of the normal and abnormal human pupil

Anatomical, experimental, and computer simulation studies were used to determine the structure of the neurophysiological model of the pupil size control system. The computer simulation of this model demonstrates the role played by each of the elements in the neurological pathways influencing the size of the pupil. Simulations of the effect of drugs and common abnormalities in the system help to illustrate the workings of the pathways and processes involved. The simulation program allows the user to select pupil condition (normal or an abnormality), specific site along the neurological pathway (retina, hypothalamus, etc.) drug class input (barbiturate, narcotic, etc.), stimulus/response mode, display mode, stimulus type and input waveform, stimulus or background intensity and frequency, the input and output conditions, and the response at the neuroanatomical site. The model can be used as a teaching aid or as a tool for testing hypotheses regarding the system.

Krenz, W.↗

Biolink Model: A universal schema for knowledge graphs in clinical, biomedical, and translational science

Abstract Within clinical, biomedical, and translational science, an increasing number of projects are adopting graphs for knowledge representation. Graph‐based data models elucidate the interconnectedness among core biomedical concepts, enable data structures to be easily updated, and support intuitive queries, visualizations, and inference algorithms. However, knowledge discovery across these “knowledge graphs” (KGs) has remained difficult. Data set heterogeneity and complexity; the proliferation of ad hoc data formats; poor compliance with guidelines on findability, accessibility, interoperability, and reusability; and, in particular, the lack of a universally accepted, open‐access model for standardization across biomedical KGs has left the task of reconciling data sources to downstream consumers. Biolink Model is an open‐source data model that can be used to formalize the relationships between data structures in translational science. It incorporates object‐oriented classification and graph‐oriented features. The core of the model is a set of hierarchical, interconnected classes (or categories) and relationships between them (or predicates) representing biomedical entities such as gene, disease, chemical, anatomic structure, and phenotype. The model provides class and edge attributes and associations that guide how entities should relate to one another. Here, we highlight the need for a standardized data model for KGs, describe Biolink Model, and compare it with other models. We demonstrate the utility of Biolink Model in various initiatives, including the Biomedical Data Translator Consortium and the Monarch Initiative, and show how it has supported easier integration and interoperability of biomedical KGs, bringing together knowledge from multiple sources and helping to realize the goals of translational science.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-12: Treatment Site and View Recognition in X-Ray Images with Hierarchical Multiclass Recognition Models

Purpose: To investigate an approach of automatically recognizing anatomical sites and imaging views (the orientation of the image acquisition) in 2D X-ray images. Methods: A hierarchical (binary tree) multiclass recognition model was developed to recognize the treatment sites and views in x-ray images. From top to bottom of the tree, the treatment sites are grouped hierarchically from more general to more specific. Each node in the hierarchical model was designed to assign images to one of two categories of anatomical sites. The binary image classification function of each node in the hierarchical model is implemented by using a PCA transformation and a support vector machine (SVM) model. The optimal PCA transformation matrices and SVM models are obtained by learning from a set of sample images. Alternatives of the hierarchical model were developed to support three scenarios of site recognition that may happen in radiotherapy clinics, including two or one X-ray images with or without view information. The performance of the approach was tested with images of 120 patients from six treatment sites – brain, head-neck, breast, lung, abdomen and pelvis – with 20 patients per site and two views (AP and RT) per patient. Results: Given two images in known orthogonal views (AP and RT), the hierarchical model achieved a 99% average F1 score to recognize the six sites. Site specific view recognition models have 100 percent accuracy. The computation time to process a new patient case (preprocessing, site and view recognition) is 0.02 seconds. Conclusion: The proposed hierarchical model of site and view recognition is effective and computationally efficient. It could be useful to automatically and independently confirm the treatment sites and views in daily setup x-ray 2D images. It could also be applied to guide subsequent image processing tasks, e.g. site and view dependent contrast enhancement and image registration. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Discrete element modeling of irregular-shaped soft pine particle flow in an FT4 powder rheometer

Pine residues are a commonly used biomass feedstock that consists of different anatomical fractions, each with distinct particle characteristics. Here, in this work, an experiment-informed discrete element model is developed to investigate the flowability of pine residues in an FT4 rheometer. Multi-sphere particles with distinct particle attributes are created to model each anatomical fraction type. A systematic analysis of specimens with varying particle characteristics (e.g., anatomical fraction type, particle shape, and size) is conducted to elucidate the relationship between particle attributes and flowability. The results show that stems recorded the highest axial force and torque and, correspondingly, the highest flow energy, which is attributed to their high stiffness and interlocking effect. Increasing their percentage in the mixture increases the flow energy while increasing needles tends to decrease flow energy. Knowledge gained in this study on the flow of anatomical fractions is important for the efficient and robust processing of pine residues.

09 BIOMASS FUELS↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-88: Comparison of Two Deformable Image Registration Algorithms for CT-To-CT Contour Propagation

Purpose: To compare the contour propagation accuracy of two deformable image registration (DIR) algorithms in the Raystation treatment planning system – the “Hybrid” algorithm based on image intensities and anatomical information; and the “Biomechanical” algorithm based on linear anatomical elasticity and finite element modeling. Methods: Both DIR algorithms were used for CT-to-CT deformation for 20 lung radiation therapy patients that underwent treatment plan revisions. Deformation accuracy was evaluated using landmark tracking to measure the target registration error (TRE) and inverse consistency error (ICE). The deformed contours were also evaluated against physician drawn contours using Dice similarity coefficients (DSC). Contour propagation was qualitatively assessed using a visual quality score assigned by physicians, and a refinement quality score (0 0.9 for lungs, > 0.85 for heart, > 0.8 for liver) and similar qualitative assessments (VQS < 0.35, RQS > 0.75 for lungs). When anatomical structures were used to control the deformation, the DSC improved more significantly for the biomechanical DIR compared to the hybrid DIR, while the VQS and RQS improved only for the controlling structures. However, while the inclusion of controlling structures improved the TRE for the hybrid DIR, it increased the TRE for the biomechanical DIR. Conclusion: The hybrid DIR was found to perform slightly better than the biomechanical DIR based on lower TRE while the DSC, VQS, and RQS studies yielded comparable results for both. The use of controlling structures showed considerable improvement in the hybrid DIR results and is recommended for clinical use in contour propagation.

60 APPLIED LIFE SCIENCES↗

SIS epidemiological model for adaptive RT: Forecasting the parotid glands shrinkage during tomotherapy treatment

Purpose: A susceptible-infected-susceptible (SIS) epidemic model was applied to radiation therapy (RT) treatments to predict morphological variations in head and neck (H&N) anatomy. Methods: 360 daily MVCT images of 12 H&N patients treated by tomotherapy were analyzed in this retrospective study. Deformable image registration (DIR) algorithms, mesh grids, and structure recontouring, implemented in the RayStation treatment planning system (TPS), were applied to assess the daily organ warping. The parotid’s warping was evaluated using the epidemiological approach considering each vertex as a single subject and its deformed vector field (DVF) as an infection. Dedicated IronPython scripts were developed to export daily coordinates and displacements of the region of interest (ROI) from the TPS. MATLAB tools were implemented to simulate the SIS modeling. Finally, the fully trained model was applied to a new patient. Results: A QUASAR phantom was used to validate the model. The patients’ validation was obtained setting 0.4 cm of vertex displacement as threshold and splitting susceptible (S) and infectious (I) cases. The correlation between the epidemiological model and the parotids’ trend for further optimization of alpha and beta was carried out by Euclidean and dynamic time warping (DTW) distances. The best fit with experimental conditions across all patients (Euclidean distance of 4.09 ± 1.12 and DTW distance of 2.39 ± 0.66) was obtained setting the contact rate at 7.55 ± 0.69 and the recovery rate at 2.45 ± 0.26; birth rate was disregarded in this constant population. Conclusions: Combining an epidemiological model with adaptive RT (ART), the authors’ novel approach could support image-guided radiation therapy (IGRT) to validate daily setup and to forecast anatomical variations. The SIS-ART model developed could support clinical decisions in order to optimize timing of replanning achieving personalized treatments.

60 APPLIED LIFE SCIENCES↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Greater aperture counteracts effects of reduced stomatal density on WUE: a case study on sugarcane and meta-analysis

Stomata regulate CO 2 and water vapor exchange between leaves and the atmosphere. Stomata are a target for engineering to improve crop intrinsic water use efficiency (iWUE). One example is by expressing genes that lower stomatal density (SD) and reduce stomatal conductance (g sw ). However, the quantitative relationship between reduced SD, g sw , and the mechanisms underlying it is poorly understood. We addressed this knowledge gap using low-SD sugarcane (Saccharum spp. hybrid) as a case study alongside a meta-analysis of data from 10 species. Transgenic expression of EPIDERMAL PATTERNING FACTOR 2 from Sorghum bicolor (SbEFP2) in sugarcane reduced SD by 26-38% but did not affect gsw compared to wildtype. Further, no changes occurred in stomatal complex size or proxies for photosynthetic capacity. Measurements of gas exchange at low CO 2 concentrations that promote complete stomatal opening to normalize aperture size between genotypes were combined with modeling of maximum gsw from anatomical data. These data suggest that increased stomatal aperture is the only possible explanation for maintaining gsw when SD is reduced. Meta-analysis across C 3 dicots, C 3 monocots, and C 4 monocots revealed engineered reductions in SD are strongly correlated with lower gsw (r 2 =0.60-0.98), but this response is damped relative to the change in anatomy.

59 BASIC BIOLOGICAL SCIENCES↗