Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

RadMAP: The Radiological Multi-sensor Analysis Platform

The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. Here we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.

47 OTHER INSTRUMENTATION↗

Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IR Thermographic Analysis of 3D Printed CFRP Reference Samples with Back-Drilled and Embedded Defects

Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.

36 MATERIALS SCIENCE↗

A Multi-Sample Standoff Multimodal Biometric System

Abstract The data captured by existing standoff biometric systems typically has lower biometric recognition performance than their close range counterparts due to imaging challenges, pose challenges, and other factors. To assist in overcoming these limitations systems typically perform in a multi-modal capacity such as Honeywell s Combined Face and Iris (CFAIRS) [21] system. While this improves the systems performance, standoff systems have yet to be proven as accurate as their close range equivalents. We will present a standoff system capable of operating up to 7 meters in range. Unlike many systems such as the CFAIRS our system captures high quality 12 MP video allowing for a multi-sample as well as multi-modal comparison. We found that for standoff systems multi-sample improved performance more than multi-modal. For a small test group of 50 subjects we were able to achieve 100% rank one recognition performance with our system.

Barstow, Del R↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shape-constrained Input Estimation for Efficient Multi-shaker Vibration Testing

Multi-shaker vibration testing is gaining interest from structural dynamics test engineers as it can provide a much more accurate match to complicated field vibration responses than traditional single-axis shaker tests. However, the force capabilities of the small modal shakers typically used in multi-shaker vibration tests has limited the achievable response levels. To date, most multi-shaker vibration tests have been performed using a variety of standard, commercially-available control systems. While these control systems are adequate for a wide range of multiple-input/multiple-output tests, their control algorithms have not been tailored for the specific problem of multi-shaker vibration tests: efficiently coordinating the various shakers to work together to achieve a desired response. Here, a new input estimation algorithm is developed and demonstrated using simulations and actual test data. This algorithm, dubbed shape-constrained input estimation, is shown to effectively coordinate multiple shakers using a set of constraint vectors based on the deflection shapes of the test structure. This is accomplished by using the singular vector shapes of the system frequency response matrix, which allows the constraint vectors to automatically change as a function of frequency. Simulation and test results indicate a significant reduction in the input forces required to achieve a desired response. Finally, the results indicate that shape-constrained input estimation is an effective method to achieve higher response levels from limited shaker forces which will enable higher level multi-shaker vibration tests to be performed.

42 ENGINEERING↗

Audiovisual Fusion: Challenges and New Approaches

In this study, we review recent results on audiovisual (AV) fusion. We also discuss some of the challenges and report on approaches to address them. One important issue in AV fusion is how the modalities interact and influence each other. This review will address this question in the context of AV speech processing, and especially speech recognition, where one of the issues is that the modalities both interact but also sometimes appear to desynchronize from each other. An additional issue that sometimes arises is that one of the modalities may be missing at test time, although it is available at training time; for example, it may be possible to collect AV training data while only having access to audio at test time. We will review approaches to address this issue from the area of multiview learning, where the goal is to learn a model or representation for each of the modalities separately while taking advantage of the rich multimodal training data. In addition to multiview learning, we also discuss the recent application of deep learning (DL) toward AV fusion. We finally draw conclusions and offer our assessment of the future in the area of AV fusion.

47 OTHER INSTRUMENTATION↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

TRIPWIRE – Deployment and Field-Testing Report

TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

General parity-odd CMB bispectrum estimation

We develop a methodology for estimating parity-odd bispectra in the cosmic microwave background (CMB). This is achieved through the extension of the original separable modal methodology to parity-odd bispectrum domains (ℓ{sub 1}+ℓ{sub 2}+ℓ{sub 3} = odd). Through numerical tests of the parity-odd modal decomposition with some theoretical bispectrum templates, we verify that the parity-odd modal methodology can successfully reproduce the CMB bispectrum, without numerical instabilities. We also present simulated non-Gaussian maps produced by modal-decomposed parity-odd bispectra, and show the consistency with the exact results. Our new methodology is applicable to all types of parity-odd temperature and polarization bispectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonintrusive reduced order modeling framework for quasigeostrophic turbulence

In this study, we present a nonintrusive reduced order modeling (ROM) framework for large-scale quasistationary systems. The framework proposed in this work exploits the time series prediction capability of long short-term memory (LSTM) recurrent neural network architecture such that (1) in the training phase, the LSTM model is trained on the modal coefficients extracted from the high-resolution data snapshots using proper orthogonal decomposition (POD) transform, and (2) in the testing phase, the trained model predicts the modal coefficients for the total time recursively based on the initial time history. Hence, no prior information about the underlying governing equations is required to generate the ROM. To illustrate the predictive performance of the proposed framework, the mean flow fields and time series response of the field values are reconstructed from the predicted modal coefficients by using an inverse POD transform. As a representative benchmark test case, we consider a two-dimensional quasigeostrophic ocean circulation model which, in general, displays an enormous range of fluctuating spatial and temporal scales. We first demonstrate that the conventional Galerkin projection-based reduced order modeling of such systems requires a high number of POD modes to obtain a stable flow physics. In addition, ROM-Galerkin projection (ROM-GP) does not seem to capture the intermittent bursts appearing in the dynamics of the first few most energetic modes. However, the proposed nonintrusive ROM framework based on LSTM (ROM-LSTM) yields a stable solution even for a small number of POD modes. We also observe that the ROM-LSTM model is able to capture quasiperiodic intermittent bursts accurately, and yields a stable and accurate mean flow dynamics using the time history of a few previous time states, denoted as the lookback time window in this paper. We show several features of ROM-LSTM framework such as significantly higher accuracy than ROM-GP, and faster performance using larger time step size. Throughout the paper, we demonstrate our findings in terms of time series evolution of the field values and mean flow patterns, which suggest that the proposed fully nonintrusive ROM framework is robust and capable of predicting chaotic nonlinear fluid flows in an extremely efficient way compared to the conventional projection-based ROM framework.

42 ENGINEERING↗

Squeeze Film Damper Experimental and Numerical Correlation: Test Setup Description and Parameter Identification of Dry System

The process of characterizing a damper involves both experimental techniques and model simulation. Experiments characterize dynamic behavior of a system through empirical modal analysis using impact and shaker testing. The layout of the test setup is crucial for a low-mass, nonlinear system. Physical arrangement, orientation of the system, and instrumentation affect the results that are discussed in this paper. These results can be used to validate a numerical simulation of the same system. With a validated model, important physical input parameters and modeling techniques can be determined and implemented in future designs. In other words, this modeling can be used with confidence to design alternative dampers that may be difficult, costly, and time-consuming to characterize experimentally.

Cook, Jason↗

SU-E-T-28: A Treatment Planning Comparison of Volumetric Modulated Arc Therapy Vs. Proton Therapy for Post-Mastectomy Radiotherapy

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) can be challenging for patients with left-sided breast cancer due to the PTV size and proximity to critical organs. This study investigates the use of protons for PMRT in a clinically-representative cohort of patients, and quantitatively compares volumetric modulated arc therapy (VMAT) to proton therapy to have an evidence-based rationale for selecting a treatment modality for these patients. Methods: Eight left-sided PMRT patients previously treated at our clinic with VMAT were identified for the study. PTVs included the chest wall and regional lymph nodes. Passively scattered (PS) and intensity modulated proton therapy (IMPT) plans were constructed using the Eclipse proton planning system. The resulting plans were compared to the original VMAT plan on the basis of PTV coverage; dose homogeneity index (DHI) and conformity index (CI); dose to organs at risk (OAR); tumor control probability (TCP), normal tissue complication probability (NTCP) and secondary cancer complication probability (SCCP). Differences were tested for significance using the paired Student's t-test (p<0.01). Results: All modalities produced clinically acceptable PMRT plans. The comparison demonstrated proton treatment plans provide significantly lower NTCP values for the heart and the lung while maintaining significantly better CI and DHI. At a prescribed dose of 50.4 Gy (RBE) in the PTV, the calculated mean NTCP value for the patients decreased from 1.3% to 0.05% for the whole heart (cardiac mortality) and from 3.8% to 1.1% for the lungs (radiation pneumonitis) for both proton therapy plans from VMAT plans. Both proton modalities showed a significantly lower SCCP for the contralateral breast compared to VMAT. Conclusion: All three plans (VMAT, PS, and IMPT) provide acceptable treatment plans for PMRT. However, proton therapy shows a significant advantage over VMAT with regards to sparing OARs and may be more advantageous for patients with unfavorable anatomy.

60 APPLIED LIFE SCIENCES↗

Spatially weighted mutual information image registration for image guided radiation therapy

Purpose: To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). Methods: It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically ''important'' areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/MVCT image sets. The SWMI registration with a Gaussian weight function (SWMI-GW) was tested between two different imaging modalities: CT and MRI image sets. Results: SWMI-GW converges 10% faster than registration using mutual information with an ROI. SWMI-GW as well as SWMI with SOI-based weight function (SWMI-SOI) shows better compensation of the target organ's deformation and neighboring critical organs' deformation. SWMI-GW was also used to successfully fuse MRI and CT images. Conclusions: Rigid-body image registration using our SWMI-GW and SWMI-SOI as cost functions can achieve better registration results in (a) designated image region(s) as well as faster convergence. With the theoretical foundation established, we believe SWMI could be extended to larger clinical testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-489: Plan Comparisons of Re-Irradiation Treatment of Three Intensity Modulated Techniques

Purpose: There have been controversial reports on the comparison of dosimetric quality of TomoTherapy (Tomo), VMAT and IMRT. One of the main reasons is the sampled cases are often not dosimetrically challenging enough to test the limit of optimization/delivery modalities. We chose difficult re-irradiation cases when certain organ at risk (OAR) requires extremely low dose to examine the ability of OAR sparing of three main intensity modulated techniques. Methods: Three previous treated patients with disease site on head and neck (HN), brain and lung are planned for reirradiation treatment. The Tomo planning used jaw 2.5cm and pitch 0.3. VMAT and IMRT were planned on Pinnacle for a Varian 21iX Linac with MLC leaf width 5mm. VMAT plan used 2 Arcs and IMRT plan had beams 11–13. The dosimetric endpoints and treatment time were compared for each technique of each patient. Results: Plans of three techniques cover PTV similarly. The HN case requires PTV dose 60Gy but to limit dose of cord which is 8mm away <12Gy. The cord dose of Tomo, VMAT and IMRT plan is 11.6Gy, 11.3Gy and 11.0Gy, respectively. The brain case has PTV prescription 50.4 Gy while requiring the dose of brainstem < 28Gy. Tomo, VMAT and IMRT plan generate brainstem dose 27.6Gy, 27.6Gy and 27.1Gy respectively. For the lung case, PTV was prescribed 42.5Gy but cord dose constraint was 22.5Gy. The cord dose is optimized to 22.3Gy, 20.8Gy and 21.4Gy by Tomo, VMAT and IMRT, respectively. The delivery time if normalized to Tomo is 47.0%/145.6% (VMAT/IMRT), 33.3%/106.3% and 74.1%/245.4% for HN, brain and lung case, respectively. Conclusion: Difficult re-irradiation cases were used to test the limit of three intensity modulated techniques. Tomo, VMAT and IMRT show similar dosimetry while VMAT is the most efficient one and IMRT is the least.

60 APPLIED LIFE SCIENCES↗

A semi-local spectral/hp element solver for linear elasticity problems:

We develop an efficient semi-local method for speeding up the solution of linear systems arising in spectral/hp element discretization of the linear elasticity equations. The main idea is to approximate the element-wise residual distribution with a localization operator we introduce in this paper, and subsequently solve the local linear system. Additionally, we decouple the three directions of displacement in the localization operator, hence enabling the use of an efficient low energy preconditioner for the conjugate gradient solver. This approach is effective for both nodal and modal bases in the spectral/hp element method, but here, we focus on the modal hierarchical basis. In numerical tests, we verify that there is no loss of accuracy in the semi-local method, and we obtain good parallel scalability and substantial speed-up compared to the original formulation. In particular, our tests include both structure-only and fluid-structure interaction problems, with the latter modeling a 3D patient-specific brain aneurysm. Copyright © 2014 John Wiley & Sons, Ltd.

Engineering↗

Evaluation of Impedance Measurement Using Spread Spectrum Time Domain Reflectometry

We evaluate the feasibility of spectral time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) as a new modality for impedance measurement to test energized/noisy systems over a very broad frequency spectrum (near dc to gigahertz) as well as multiple channels in parallel. We simulate how the S/SSTDR signal parameters (signal-to-noise ratio (SNR) frequency and length of the pseudo-noise (PN) signals) affect the accuracy and usable frequency band for reflection coefficient and impedance measurement. An initial measurement validation is included. Here, we conclude with a recommendation of what will be required for a viable multichannel impedance (and reflection, transmission coefficient) measurement system for either energized or nonenergized systems, in noisy environments, that can test multiple channels simultaneously.

14 SOLAR ENERGY↗