Magic Angles and Fractional Chern Insulators in Twisted Homobilayer Transition Metal Dichalcogenides

We explain the appearance of magic angles and fractional Chern insulators in twisted K-valley homobilayer transition metal dichalcogenides by mapping their continuum model to a Landau level problem. Here, our approach relies on an adiabatic approximation for the quantum mechanics of valence band holes in a layer-pseudospin field that is valid for sufficiently small twist angles and on a lowest Landau level approximation that is valid for sufficiently large twist angles. It provides a simple qualitative explanation for the nearly ideal quantum geometry of the lowest moir´e miniband at particular twist angles, predicts that topological flat bands occur only when the valley-dependent moir´e potential is sufficiently strong compared to the interlayer tunneling amplitude, and provides a convenient starting point for the study of interactions.

36 MATERIALS SCIENCE↗

Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping

Purpose: The purpose of this work is to demonstrate that multicontrast computed tomography (CT) imaging can be performed using a Talbot-Lau interferometer without phase stepping, thus allowing for an acquisition scheme like that used for standard absorption CT. Methods: Rather than using phase stepping to extract refraction, small-angle scattering (SAS), and absorption signals, the two gratings of a Talbot-Lau interferometer were rotated slightly to generate a moire pattern on the detector. A Fourier analysis of the moire pattern was performed to obtain separate projection images of each of the three contrast signals, all from the same single-shot of x-ray exposure. After the signals were extracted from the detector data for all view angles, image reconstruction was performed to obtain absorption, refraction, and SAS CT images. A physical phantom was scanned to validate the proposed data acquisition method. The results were compared with a phantom scan using the standard phase stepping approach. Results: The reconstruction of each contrast mechanism produced the expected results. Signal levels and contrasts match those obtained using the phase stepping technique. Conclusions: Absorption, refraction, and SAS CT imaging can be achieved using the Talbot-Lau interferometer without the additional overhead of long scan time and phase stepping.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Specific features of the epitaxial growth of narrow-gap InSb quantum dots on an InAs substrate

Arrays of coherent InSb quantum dots (QDs) have been fabricated by liquid-phase epitaxy on InAs substrates in the temperature range T = 420-450{sup o}C. The QDs with a density of (0.9-2) x 10{sup 10} cm{sup -2} were 3 nm high and 13 nm in diameter. A bimodal QD size distribution was observed, which was accounted for by a combined growth mechanism of these nanoobjects. Structural characteristics of a separate InSb QD formed on the InAs surface were studied for the first time by atomic-force and transmission electron microscopies. Moire fringes were observed for the first time for QDs in the InSb/InAs system, with the moire period of 3.5 nm corresponding to InSb QDs without an admixture of arsenic.

39↗

Fatigue crack tip deformation and fatigue crack propagation

The effects of stress ratio, prestress cycling and plate thickness on the fatigue crack propagation rate are studied on 2024-T351 aluminum alloy. Fatigue crack propagation rate increases with the plate thickness and the stress ratio. Prestress cycling below the static yield strength has no noticeable effect on the fatigue crack propagation rate. However, prestress cycling above the static yield strength causes the material to strain harden and increases the fatigue crack propagation rate. Crack tip deformation is used to study the fatigue crack propagation. The crack tip strains and the crack opening displacements were measured from moire fringe patterns. The moire fringe patterns were obtained by a double exposure technique, using a very high density master grille (13,400 lines per inch).

Kang, T. S.↗

A simplified holographic-interferometry technique for real-time flow visualization and analysis

A holographic-interferometry technique for flow visualization and analysis that produces real-time moire fringes is described from both experimental and application considerations. It has three chief advantages: real-time data for continuous observation and photography, ease of optical adjustment, and capability of using ordinary-glass test-section windows without affecting the results. A theoretical discussion is presented describing the formation of the fringes in holographic terms and then comparing this result to that which is obtained from a conventional moire approach. A discussion on obtaining density information from the fringe pattern is also included.

Long, S. A.↗

On the off-axis tensile test for unidirectional composites

The off axis tensile test was examined experimentally to obtain actual displacement fields over the surface of graphite polyimide coupon specimens. The experimental results were compared with approximate analytical solutions and generated finite element results. An optical method of high sensitivity moire interferometry was used to determine the actual displacements to high precision. The approximate analytical solution and the finite element results compare very favorably with the measured centerline displacements in the test section, and the finite element displacement fields provide excellent agreement with the moire displacements throughout the specimen. A 15 degree fiber orientation and coupon aspect ratios of 5 and 15 are presented.

Nemeth, M. P.↗

A study of model deflection measurement techniques applicable within the national transonic facility

Moire contouring, scanning interferometry, and holographic contouring were examined to determine their practicality and potential to meet performance requirements for a model deflection sensor. The system envisioned is to be nonintrusive, and is to be capable of mapping or contouring the surface of a 1-meter by 1-meter model with a resolution of 50 to 100 points. The available literature was surveyed, and computations and analyses were performed to establish specific performance requirements, as well as the capabilities and limitations of such a sensor within the geometry of the NTF section test section. Of the three systems examined, holographic contouring offers the most promise. Unlike Moire, it is not hampered by limited contour spacing and extraneous fringes. Its transverse resolution can far exceed the limited point sampling resolution of scanning heterodyne interferometry. The availability of the ruby laser as a high power, pulsed, multiple wavelength source makes such a system feasible within the NTF.

Hildebrand, B. P.↗

Isopachic contouring of opaque plates

Contour maps of change of thickness of opaque plates subjected to external loads are obtained using holographic interferometry in conjunction with the moire effect. A simple holographic-interferometry arrangement is used first to obtain contour maps of the out-of-plane displacements of the two sides of the object. Carrier patterns of equal magnitude but opposite signs are added to these contours. Superposition of the reconstructed holograms of the two sides produces a pattern of additive-moire fringes, which are contours of change of thickness. Effects of midplane warpage of the loaded specimen are cancelled. Sensitivity is lambda/2 per fringe order, contrast of the isopachic-fringe pattern is excellent, and the process is compatible with a mechanical-testing-machine environment.

Post, D.↗

Real-Time Keratometer

Optical/electronic keratometer system produces contour map of corneal surface illuminated by infrared light pulses. Prevents operator error and eliminates need to apply fluorescent liquids to cornea. Keratometer provides both video display and numerical recording for corneal-transplant and radial-keratotomy surgery and for contact-lens fitting. Optical system of keratometer, circular grating pattern transmitted to corneal surface reflected onto identical circular grating on surface of fiber plate, producing Moire pattern. Data-analysis-and-display mode, laser light pulsed, and Moire pattern converted to digital information in frame grabber. Digital picture information sent to computer for processing and display.

Frazer, Robert E.↗

Compression creep of filamentary composites

Axial and transverse strain fields induced in composite laminates subjected to compressive creep loading were compared for several types of laminate layups. Unidirectional graphite/epoxy as well as multi-directional graphite/epoxy and graphite/PEEK layups were studied. Specimens with and without holes were tested. The specimens were subjected to compressive creep loading for a 10-hour period. In-plane displacements were measured using moire interferometry. A computer based data reduction scheme was developed which reduces the whole-field displacement fields obtained using moire to whole-field strain contour maps. Only slight viscoelastic response was observed in matrix-dominated laminates, except for one test in which catastrophic specimen failure occurred after a 16-hour period. In this case the specimen response was a complex combination of both viscoelastic and fracture mechanisms. No viscoelastic effects were observed for fiber-dominated laminates over the 10-hour creep time used. The experimental results for specimens with holes were compared with results obtained using a finite-element analysis. The comparison between experiment and theory was generally good. Overall strain distributions were very well predicted. The finite element analysis typically predicted slightly higher strain values at the edge of the hole, and slightly lower strain values at positions removed from the hole, than were observed experimentally. It is hypothesized that these discrepancies are due to nonlinear material behavior at the hole edge, which were not accounted for during the finite-element analysis.

Graesser, D. L.↗

Deformations and strains in a thick adherend lap joint

Displacement fields in a thick adherend lap joint were measured by high-sensitivity moire interferometry. Contour maps of in-plane U and V displacements were obtained across adhesive and adherend surfaces. Loads ranged from a modest load to a near-failure load. Quantitative results are given for displacements and strains in the adhesive and along the adhesive/adherend boundary lines. The results show nearly constant shear strain in the adhesive, nonlinear strains as a function of load or average shear stress, and viscoelastic or time-dependent response. Longitudinal normal strains in the adhesive are nearly two orders of magnitude less than the shear strains. With its subwavelength displacement resolution and high spatial resolution, moire interferometry is especially well suited for deformation studies of adhesive joints.

Post, D.↗

A semi-micromechanic interlaminar strain analysis on curved-beam specimens

Experimental analyses were performed for determination of interlaminar strains in circumferentially unidirectional curved beam specimens. Semi-circular and semi-elliptic carbon-epoxy specimens were subjected to opening mode tensile loadings. Whole field measurements were recorded at load levels from about 5 to more than 90 pct of failure loads. Contour maps of displacement fields were obtained by using moire interferometry, using reference gratings of 2400 lines/mm or 60,690 lines/in. Whole field contour maps of circumferential and interlaminar strains were obtained by using moire interferometry in a semi-micromechanic scale. Various anomalous effects were observed in the displacement fields. The zig-zag fringe patterns indicated that the fiber orientation in each layer was not truly circumferential. This deviation from the unidirectionality caused free-edge effects, such as interlaminar shear strains even at the axis of symmetry and the altered normal strains in the thickness direction. In the resin rich zones between layers, the tensile interlaminar strain was excessively large due to the large compliance. As the result of the combined effect of these anomalous behaviors, the values of the interlaminar tensile strains were larger than those predicted analytically. The modulus E sub 3 was actually smaller than the assumed value E sub 2 by 20 pct.

Joh, Duksung↗

Composite material shear property measurement using the Iosipescu specimen

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Finite element analysis and moire interferometry are used to assess the uniformity of the shear stress field in the test section of unidirectional and cross-ply graphite-epoxy composites. The nonuniformity of the strain field and the sensitivity of some fiber orientations to the specimen/fixture contact mechanics are discussed. The shear responses obtained for unidirectional and cross-ply graphite-epoxy composites are discussed and problems associated with anomalous behavior are addressed. An experimental determination of the shear response of a range of material systems using strain gage instrumentation and moire interferometry is performed.

Ho, Henjen↗

A comparison of three shear test methods for composite materials

A graphite-epoxy composite material system is used to evaluate the performance of three popular shear tests - the 10-deg off-axis, the +/-45-deg tension, and the Iosipescu specimen tested in the modified Wyoming fixture. A comparison of the shear stress-strain response for each test method is made using a conventional strain gage instrument and moire interferometry. The uniformity and purity of the strain fields in the test sections of the specimens are discussed, and the shear responses obtained from each test are presented and compared. It is shown that the shear stress-strain responses obtained by instrumenting only one face of the 90-deg Iosipescu specimen could give erroneous results. The +/-45-deg tensile and 0-deg Iosipescu specimens were not affected by front-to-back face shear strain variations. Correction factors could be applied to bring all responses together, within the limits of the material uniformity, which was itself documented in the moire fringe patterns.

Ho, H.↗

Telescope for x ray and gamma ray studies in astrophysics

Imaging of x-rays has been achieved by various methods in astrophysics, nuclear physics, medicine, and material science. A new method for imaging x-ray and gamma-ray sources avoids the limitations of previously used imaging devices. Images are formed in optical wavelengths by using mirrors or lenses to reflect and refract the incoming photons. High energy x-ray and gamma-ray photons cannot be reflected except at grazing angles and pass through lenses without being refracted. Therefore, different methods must be used to image x-ray and gamma-ray sources. Techniques using total absorption, or shadow casting, can provide images in x-rays and gamma-rays. This new method uses a coder made of a pair of Fresnel zone plates and a detector consisting of a matrix of CsI scintillators and photodiodes. The Fresnel zone plates produce Moire patterns when illuminated by an off-axis source. These Moire patterns are deconvolved using a stepped sine wave fitting or an inverse Fourier transform. This type of coder provides the capability of an instantaneous image with sub-arcminute resolution while using a detector with only a coarse position-sensitivity. A matrix of the CsI/photodiode detector elements provides the necessary coarse position-sensitivity. The CsI/photodiode detector also allows good energy resolution. This imaging system provides advantages over previously used imaging devices in both performance and efficiency.

Weaver, W. D.↗

An Evaluation of the Iosipescu Specimen for Composite Materials Shear Property Measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. An experimental investigation using conventional strain gage instrumentation and moire interferometry is performed. A finite element analysis of the Iosipescu shear test for unidirectional and cross-ply composites is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon the strain gage measurements used for the determination of composite shear moduli. From the test results for graphite-epoxy laminates, it is shown that the proximity of the load introduction point to the test section greatly influences the individual gage readings for certain fiber orientations but the effect upon shear modulus measurement is relatively unimportant. A numerical study of the load contact effect shows the sensitivity of some fiber configurations to the specimen/fixture contact mechanism and may account for the variations in the measured shear moduli. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and yielded spurious shear stress-strain curves. In the numerical analysis, it is shown that the Iosipescu specimens for different fiber orientations have to be modeled differently in order to closely approximate the true loading conditions. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors, which are determined for the region occupied by the strain gage rosette, are found to be dependent upon the material orthotropic ratio and the finite element models. Based upon the experimental and numerical results, recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed. Further application of the Iosipescu shear test to woven fabric composites is presented. The limitations of the traditional strain gage instrumentation on the satin weave and high tow plain weave fabrics is discussed. Test results of a epoxy based aluminum particulate composite is also presented. A modification of the Iosipescu specimen is proposed and investigated experimentally and numerically. It is shown that the proposed new specimen design provides a more uniform shear stress field in the test section and greatly reduces the normal and shear stress concentrations in the vicinity of the notches. While the fabrication and the material cost of the proposed specimen is tremendously reduced, it is shown the accuracy of the shear modulus measurement is not sacrificed.

Ho, Henjen↗

Evaluation of a ''CMOS'' Imager for Shadow Mask Hard X-ray Telescope

We have developed a hard x-ray coder that provides high angular resolution imaging capability using a coarse position sensitive image plane detector. The coder consists of two Fresnel zone plates. (FZP) Two such 'FZP's generate Moire fringe patterns whose frequency and orientation define the arrival direction of a beam with respect to telescope axis. The image plane detector needs to resolve the Moire fringe pattern. Pixilated detectors can be used as an image plane detector. The recently available 'CMOS' imager could provide a very low power large area image plane detector for hard x-rays. We have looked into a unit made by Rad-Icon Imaging Corp. The Shadow-Box 1024 x-ray camera is a high resolution 1024xl024 pixel detector of 50x50 mm area. It is a very low power, stand alone camera. We present some preliminary results of our investigation of evaluation of such camera.

Desai, Upendra D.↗

Nucleation and growth of Fe and FeO nanoparticles and films on Au(1 1 1)

We have studied the formation of Fe and FeO nanoparticles and thin films on the reconstructed Au(1 1 1) surface. Scanning tunneling microscopy (STM), X-ray photoelectron spectroscopy (XPS), and ion-scattering spectroscopy (ISS) were used to evaluate the structure and composition of Fe and FeO nanoparticles and films at different growth conditions. Iron grows as one monolayer high triangular particles on the Au(1 1 1) reconstruction. FeO was grown by exposing the Fe nanoparticles to molecular oxygen at 323 K, followed by annealing at 500–700 K. XPS results indicate that FeO is formed after room temperature oxidation. STM images show that well-ordered iron oxide particles form after annealing to 700 K. STM images also show evidence of a overlayer lattice with a short periodicity of 3.3 Å modulated by a larger periodicity of approximately 35 Å. The larger periodicity results from a moiré pattern formed between the iron oxide overlayer and the underlying Au(1 1 1) surface.

36 MATERIALS SCIENCE↗