Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Steady State Temperature Profile in a Cylinder Heated by Microwaves

A new theory has been developed to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles where computed for- alumina rods of various radii contained in a cavity excite in one of the TM(sub OnO) modes with n = 1, 2 or 3. Calculations where also performed with a concentric outer cylindrical tube surrounding the rod to investigate hybrid heating. The parameters studies of the sample center and surface temperature where performed as a function of the total power transmitted into the cavity. Also, the total hemispherical emissivity was varied at boundaries of the rod, surrounding tube, and cavity walls. The result are discussed in the context of controlling the average rod temperature and the temperature distribution in the rod during microwave processing.

Jackson, H. W.↗

The status of cesium beam frequency standards

There has been a lot of progress in cesium beam frequency standards in the last few years some of which will be reported here. Optical pumping is being pursued actively in a number of laboratories. Optically slowed and cooled beams have been demonstrated as well as traps for cold neutral atoms. The microwave cavity performance with regard to local phase shift at the beam holes was improved by use of carefully designed and built ring structures for the cavity ends. Work is being done on improvements in electronics with some emphasis on use of digital circuitry and microprocessors. The frequency pulling due to microwave Delta M = +/- 1 transitions (Ramsey pulling) was analyzed and shown to be important. Status of cesium beam frequency standards in some of the laboratories as well as some of the commercial work is discussed. Optical pumping and detection are discussed.

Cutler, Leonard S.↗

Steady State Temperature Profile in a Cylinder Heated by Microwaves

We have developed a new theory to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii contained in a cavity excited in one of the TM0n0 modes with n = 1, 2, or 3. Sample surface and center temperatures will be presented as a function of total sample absorbed power or electric field strength at the sample surface. An approach for attaining more uniform heating within the sample by reducing the magnitude of the inverted temperature profile using a concentric outer cylindrical tube will be discussed. Also, parametric studies will be reported for model calculations in which the total hemispherical emissivity was varied at boundaries of the sample and surrounding tube and at the cavity wall. The results will be discussed in the context of controlling both the average sample temperature and the temperature distribution in the sample during microwave processing.

steady-state↗

Microwave bonding of MEMS component

Bonding of MEMs materials is carried out using microwave. High microwave absorbing films are placed within a microwave cavity, and excited to cause selective heating in the skin of the material. This causes heating in one place more than another. Thereby minimizing the effects of the bonding microwave energy.

Barmatz, Martin B.↗

Decoherence Noise on the Superconducting Qubits Training Program

Quantum computing is a growing field with promising applications in a variety of fields such as healthcare, energy consumption, and cryptography. Quantum computing leverages the principles of quantum mechanics - superposition and entanglement. Yet, in the Noisy Intermediate Scale Quantum (NISQ) Era - quantum systems face the major challenge of decoherence due to noise. This era is characterized by low amounts of qubits and high gate error. Decoherence leads to the loss of the quantum information stored in the qubit. Noise occurs with any quantum system that is exposed to the environment. It should also be noted that quantum information can be stored in the cavity - Fermilab specializes in coupling transmons to ultrahigh-Q SRF cavities. The Superconducting Qubits Training Program (SQTP) provides a visualization for beginners in quantum computing. The open quantum system simulated is a superconducting qubit (two-level atom) coupled to a microwave cavity whose excitations are photons. The Rotating Wave Approximation of the Jaynes-Cumming Hamiltonian is used. SQTP utilizes open-source Python-based libraries scQubits, NumPy, and QuTiP alongside the Master Lindblad equation. In this project, we study the different decay behaviors of qubits and cavities with collapse operators.

Lopez, Sara↗

Dual-rail encoding with superconducting cavities

The design of quantum hardware that reduces and mitigates errors is essential for practical quantum error correction (QEC) and useful quantum computation. To this end, we introduce the circuit-Quantum Electrodynamics (QED) dual-rail qubit in which our physical qubit is encoded in the single-photon subspace, { | 01 〉 , | 10 〉 } , of two superconducting microwave cavities. The dominant photon loss errors can be detected and converted into erasure errors, which are in general much easier to correct. In contrast to linear optics, a circuit-QED implementation of the dual-rail code offers unique capabilities. Using just one additional transmon ancilla per dual-rail qubit, we describe how to perform a gate-based set of universal operations that includes state preparation, logical readout, and parametrizable single and two-qubit gates. Moreover, first-order hardware errors in the cavities and the transmon can be detected and converted to erasure errors in all operations, leaving background Pauli errors that are orders of magnitude smaller. Hence, the dual-rail cavity qubit exhibits a favorable hierarchy of error rates and is expected to perform well below the relevant QEC thresholds with today’s coherence times.

97 MATHEMATICS AND COMPUTING↗

Cosmic Axion Background detection using resonant cavity arrays

The axion is a well-motivated and generic extension of the Standard Model. If produced in the early universe, axions may still be relativistic today, forming a Cosmic Axion Background (CaB) potentially detectable in direct detection experiments. Although CaB is expected to be broadband, which makes it challenging to be detected, a high-quality-factor microwave cavity acts as a narrowband filter with response peaked at its resonant frequency. We propose a new strategy using multi-cavity arrays to distinguish signal from background noise by exploiting spatial correlations of the axion-induced electric field which are set by the cavity quality factor. We compute the two-point correlation function for electric fields in spatially separated cavities sourced by an isotropic CaB. Analyzing various cavity geometries, we find that stacked, wide-base cavity arrays offer coherent enhancement of the axion signal. We apply our formalism to prospective upgrades of the ADMX experiment, including configurations with four and eighteen coupled cavities. Although these arrays do not achieve a coherent enhancement, optimizing the geometry could potentially yield an $\mathcal{O}(1)$ improvement in the sensitivity to the CaB.

Axions and ALPs↗

New Dielectric Measurement Data to Determine the Permittivity of Seawater at 1.4313 Hz

This paper describes the new measurements - made in 2010-2011 - of the dielectric constant of seawater at 1.413 GHz using a resonant cavity technique. The purpose of these measurements is to develop an accurate relationship concerning the dependence of the dielectric constant of seawater on temperature and salinity for use by the Aquarius inversion algorithm. Aquarius is a NASA/CONAE satellite mission launched in June of 2011 with the primary mission of measuring global sea surface salinity with a 1.413 GHz radiometer to an accuracy of 0.2 psu. A brass microwave cavity resonant at 1.413 GHz has been used to measure the dielectric constant of seawater. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The change of resonant frequency and the cavity Q value are used to determine the real and imaginary parts of the dielectric constant of seawater. Measurements are automated with Visual Basic software developed at the George Washington University. In this paper, new results from measurements made since September 2010 will be presented for salinities of 30, 35 and 38 psu with a temperature range of 0 C to 35 C in intervals of 5 C. These measurements are more accurate than earlier measurements made in 2008. The new results will be compared to the Klein-Swift (KS) and Meissner-Wentz (MW) model functions. The importance of an accurate model function will be illustrated by using these model functions to invert the Aquarius brightness temperature to retrieve the salinity values. The salinity values will be compared to co-located in situ data collected by Argo buoys.

Lang, R.↗

Universal Jaynes-Cummings Control of an Oscillator

The Jaynes-Cummings (JC) interaction-the coherent exchange of excitations between a two-level system and a harmonic oscillator-is one of the fundamental interactions of quantum optics, realized across platforms such as cavity quantum electrodynamics, trapped ions, mechanical resonators, and superconducting circuits. Although JC interactions and qubit rotations form a universal gate set for oscillator control, practical implementations have not been demonstrated. Here we develop and experimentally demonstrate universal JC-based oscillator control by compiling arbitrary unitary gates into sequences of JC interactions and qubit rotations. In our experiment, the oscillator is realized using a mode of a high quality factor microwave cavity and the ancilla qubit using a superconducting transmon circuit, with the JC interaction implemented by a sideband interaction enabled by the Josephson nonlinearity. The native gates are constructed to be closed below a chosen cutoff photon number, encoding a qudit with suppressed leakage errors, while ancilla relaxation errors are detectable. We further find that the dispersive shift serves as a compilation resource that reduces circuit depths. We demonstrate universal qudit control and implement a single-qutrit gate set with a mean post-selected process fidelity of 96%, as well as ququart and ququint shift gates. These results establish Jaynes-Cummings control as a practical route to universal oscillator control, enabling programmable bosonic processors across a variety of quantum platforms.

Huang, Jordan [Rutgers U., Piscataway]↗

Recent work on a microwave ion source

The performance of a microwave (2.45 GHz) plasma-disk ion source using a cylindrical microwave cavity is described. The operating characteristics in argon and xenon gases with 50-200 W of input power and gas flow rates from 10-80 sccm are presented. In particular, extracted beam current versus accelerating voltage, and specific energy vs. mass utilization efficiency and extracted beam current are presented. Double Langmuir probe measurements indicate that electron densities in excess of 10 to the 12th per cu cm can be readily achieved in the microwave generated plasma.

Asmussen, J.↗

A review of microwave-assisted process intensified multiphase reactors

Microwaves provide alternative heating and allow process intensification due to their rapid, volumetric, and selective nature. Recognizing the central role of multiphase reactors in chemical industry, a recent surge in employing microwaves is observed. We review the recent experimental and modeling investigations of microwave heating of multiphase reactors with emphasis on chemical engineering applications. Here we demonstrate that there is accumulated evidence for improved performance via microwave heating and a clear opportunity for further process intensification. In most of the cases, this improved performance stems from a temperature gradient between two phases. We discuss the ongoing debate on the mechanism by which microwaves affect chemical processes exacerbated by the inability of measuring the temperature distribution in a microwave cavity. We outline recent progress in this direction in monolith reactors and needs for future work. We underscore the lack of detailed modeling and simulation tools even for single-phase systems and emphasize the imperative for multiscale predictive modeling to bridge the experimental-modeling gap. Promising results are shown by a few recently published modeling studies that can predict the experimental measurements in complex multiphase reactors. A combination of experimental and modeling tools can provide a comprehensive picture of the microwave multiphase reactors as well as a means toward scale-up and optimization.

42 ENGINEERING↗

Three point lead screw positioning apparatus for a cavity tuning plate

Three lead screws are provided for adjusting the position of a traversing plate. Each of the three lead screws is threaded through a collar that is press fitted through the center of one of three pinion gears. A sun gear meshes with all three pinion gears and transversely moves the three lead screws upon actuation of a drive gear. The drive gear meshes with the sun gear and is driven by a handle or servomotor. When the handle or servomotor rotates the drive gear, the sun gear rotates causing the three pinion gears to rotate, thus, causing transverse movement of the three lead screws and, accordingly, transverse movement of the transversing plate. When the drive gear rotates, the traversing plate is driven in and out of a microwave cavity. Thus, the length or size of the cavity can be tuned while maintaining the traversing plate in an exact parallel relationship with an opposing plate on another end of the cavity.

Calco, Frank S.↗

A review of research and development on the microwave-plasma electrothermal rocket

The microwave-plasma electrothermal rocket (MWPETR) shows promise for spacecraft propulsion and maneuvering, without some of the drawbacks of competitive electric propulsion systems. In the MWPETR, the electric power is first converted to microwave-frequency radiation. In a specially-designed microwave cavity system, the electromagnetic energy of the radiation is transferred to the electrons in a plasma sustained in the working fluid. The resulting high-energy electrons transfer their energy to the atoms and molecules of the working fluid by collisions. The working fluid, thus heated, expands through a nozzle to generate thrust. In the MWPETR, no electrodes are in contact with the working fluid, the energy is transferred into the working fluid by nonthermal mechanisms, and the main requirement for the materials of construction is that the walls of the plasma chamber be insulating and transparent to microwave radiation at operating conditions. In this survey of work on the MWPETR, several experimental configurations are described and compared. Diagnostic methods used in the study are described and compared, including titration, spectroscopy, calorimetry, electric field measurements, gas-dynamic methods, and thrust measurements. Measured and estimated performance efficiencies are reported. Results of computer modeling of the plasma and of the gas flowing from the plasma are summarized.

Hawley, Martin C.↗

Temperature Homogeneity under Selective and Localized Microwave Heating in Structured Flow Reactors

Selective heating of different phases of multiphase systems via microwaves can result in energy savings and suppression of side reactions. However, materials properties and operating conditions that maximize temperature gradients are poorly understood. Here we utilize computational fluid dynamics (CFD) computations and temperature measurements in structured flow reactors (monoliths) in a monomodal microwave cavity to assess the temperature difference between the walls and the fluid and develop a simple lumped model to estimate when temperature gradients exist. We also explore the material’s thermal and electrical properties of structured reactors for isothermal catalyst conditions. We propose that CFD simulations can be used as a nonintrusive, predictive tool of temperature homogeneity. Importantly, we demonstrate that localized heating in the bed under several conditions rather than selective heating is responsible for the selectivity enhancement. Furthermore, our results indicate that structured beds made of high thermal conductivity materials avoid arcing and enable temperature homogeneity and low electrical conductivity materials allow microwaves to penetrate the domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increased Accuracy in the Measurement of the Dielectric Constant of Seawater at 1.413 GHz

This paper describes the latest results for the measurements of the dielectric constant at 1.413 GHz by using a resonant cavity technique. The purpose of these measurements is to develop an accurate relationship for the dependence of the dielectric constant of sea water on temperature and salinity which is needed by the Aquarius inversion algorithm to retrieve salinity. Aquarius is the major instrument on the Aquarius/SAC-D observatory, a NASA/CONAE satellite mission launched in June of20ll with the primary mission of measuring global sea surface salinity to an accuracy of 0.2 psu. Aquarius measures salinity with a 1.413 GHz radiometer and uses a scatterometer to compensate for the effects of surface roughness. The core part of the seawater dielectric constant measurement system is a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The change of resonance frequency and the cavity Q value are used to determine the real and imaginary parts of the dielectric constant of seawater introduced into the thin tube. Measurements are automated with the help of software developed at the George Washington University. In this talk, new results from measurements made since September 2010 will be presented for salinities 30, 35 and 38 psu with a temperature range of O C to 350 C in intervals of 5 C. These measurements are more accurate than earlier measurements made in 2008 because of a new method for measuring the calibration constant using methanol. In addition, the variance of repeated seawater measurements has been reduced by letting the system stabilize overnight between temperature changes. The new results are compared to the Kline Swift and Meissner Wentz model functions. The importance of an accurate model function will be illustrated by using these model functions to invert the Aquarius brightness temperature to get the salinity values. The salinity values will be compared to co-located in situ data collected by Argo buoys.

Zhou, Y.↗

(abstract) Steady State Temperature Profile in a Cylinder Heated by Microwaves

We have developed a new theory to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii excited by one of the TM0n0 modes with n = 1, 2, or 3. Sample surface and center temperatures will be presented as a function of total sample absorbed power or electric field strength at the sample surface. An approach for attaining more uniform heating within the sample by reducing the magnitude of the inverted temperature profile using a concentric outer cylindrical tube will be discussed.

microwave↗

Additively-manufactured monocrystalline YBCO superconductor

Abstract Single-crystal microstructures enable high-performance YBa 2 Cu 3 O 7-x superconductors which are however limited to simple shapes due to their brittleness. Additive manufacturing can fabricate YBa 2 Cu 3 O 7-x superconductor with complex shapes, albeit with a polycrystalline microstructure. Here, we demonstrate a route to grow single-crystals from 3D-ink-printed, polycrystalline, sintered superconducting YBa 2 Cu 3 O 7-x (YBCO or Y123) + Y 2 BaCuO 5 (Y211), manufacturing objects with complex architectures displaying both high critical current density (J c =2.1 × 10 4 A . cm –2 , 77 K) and high critical temperature (T c = 88-89.5 K). An ink containing precursor powders (Y 2 O 3 , BaCO 3 , and CuO) is 3D-extruded into complex geometries and then reaction-sintered to obtain polycrystalline Y123 + Y211. A seed is then utilized to transform these 3D-printed parts from polycrystal to monocrystal via the melt growth method. The geometric details of 3D-printed parts survive the process without slumping, sagging or collapse, despite the long-term presence of liquid above the peritectic temperature. Origami structures can be created by sheet folding after 3D-printing. This additive approach enables the facile fabrication of superconducting devices with complex shapes and architectures, such as advanced undulator magnets to generate synchrotron radiation and microwave cavities for dark-matter axion search. This work highlights the potential of additive manufacturing for producing monocrystalline cuprate superconductors and opens the door to additive manufacturing of other monocrystalline functional ceramic or semiconductor materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗