Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Novel comparison of microscopy and diffraction techniques on the structure of iron oxide nanoparticle monolayers transferred by Langmuir-Schaefer method

Iron oxide nanoparticles undergo self-assembly into well-ordered monolayer films of macroscopic size at the air-water interface. This self-assembly process is the result of the van der Waals forces between the constituent particles. For roughly spherical particles, this monolayer is a 2D hexagonal close packed lattice. With Grazing Incidence X-Ray Diffraction (GID), one can obtain global statistical information about the film’s spacing and correlation length. Herein, we demonstrate that comparable structural information can be obtained by a novel Fourier transform analysis method applied to Scanning Electron Microscopy (SEM) images taken of the film after it has been transferred to a silicon substrate. This consists of using numerical methods to isolate the lattice structure of the monolayer in the SEM image to which a 2D discrete Fourier Transform is applied and the result integrated. This results in Bragg peak information akin to that obtained from GID, whose structure shows the same hexagonal close packed lattice with similar spacing and of greater peak contrast. Furthermore, this analysis technique may prove to be a suitable alternative or compliment to GID for many applications.

36 MATERIALS SCIENCE↗

Self-consistent modelling of electrochemical strain microscopy in mixed ionic-electronic conductors: Nonlinear and dynamic regimes

The frequency dependent Electrochemical Strain Microscopy (ESM) response of mixed ionic-electronic conductors is analyzed within the framework of Fermi-Dirac statistics and the Vegard law, accounting for steric effects from mobile donors. The emergence of dynamic charge waves and nonlinear deformation of the surface in response to bias applied to the tip-surface junction is numerically explored. The 2D maps of the strain and concentration distributions across the mixed ionic-electronic conductor and bias-induced surface displacements are calculated. The obtained numerical results can be applied to quantify the ESM response of Li-based solid electrolytes, materials with resistive switching, and electroactive ferroelectric polymers, which are of potential interest for flexible and high-density non-volatile memory devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave soft x-ray microscopy for nanoscale magnetization dynamics in the 5–10 GHz frequency range

We present a scanning transmission x-ray microscopy setup combined with a novel microwave synchronization scheme for studying high frequency magnetization dynamics at synchrotron light sources. The sensitivity necessary to detect small changes in the magnetization on short time scales and nanometer spatial dimensions is achieved by combining the excitation mechanism with single photon counting electronics that is locked to the synchrotron operation frequency. Our instrument is capable of creating direct images of dynamical phenomena in the 5-10 GHz range, with high spatial resolution. When used together with circularly polarized x-rays, the above capabilities can be combined to study magnetic phenomena at microwave frequencies, such as ferromagnetic resonance (FMR) and spin waves. We demonstrate the capabilities of our technique by presenting phase resolved images of a ∼6 GHz nanoscale spin wave generated by a spin torque oscillator, as well as the uniform ferromagnetic precession with ∼0.1° amplitude at ∼9 GHz in a micrometer-sized cobalt strip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The equation of state of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one determined via in-situ optical microscopy and interferometry measurements

Quasi-hydrostatic high-pressure equations of state (EOS) are typically determined, for crystalline solids, by measuring unit-cell volumes using x-ray diffraction (XRD) techniques. However, when characterizing low-symmetry materials with large unit cells, conventional XRD approaches may become problematic. To overcome this issue, we examined the utility of a “direct” approach toward determining high pressure material volume by measuring surface area and sample thickness using optical microscopy and interferometry (OMI), respectively. We have validated this experimental approach by comparing results obtained for 2,4,6-triamino-1,3,5-trinitrobenzene TATB with an EOS determined from synchrotron XRD measurements; and, a good match is observed. We have measured the high pressure EOS of 5-nitro-2,4-dihydro-1,2,4,-triazol-3-one (α-NTO) up to 28 GPa. No high-pressure XRD EOS data have been published on α-NTO, probably due to its complex crystal structure. The results of this study suggest that OMI is a reliable and versatile alternative for determining EOSs, especially when conventional methodologies are impractical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Repulsive tip tilting as the dominant mechanism for hydrogen bond-like features in atomic force microscopy imaging

Experimental atomic force microscopy (AFM) studies have reported distinct features in regions with little electron density for various organic systems. These unexpected features have been proposed to be a direct visualization of intermolecular hydrogen bonding. Here, we apply a computational method using ab initio real-space pseudopotentials along with a scheme to account for tip tilting to simulate AFM images of the 8-hydroxyquinoline dimer and related systems to develop an understanding of the imaging mechanism for hydrogen bonds. We find that contrast for the observed “hydrogen bond” feature comes not from the electrostatic character of the bonds themselves but rather from repulsive tip tilting induced by neighboring electron-rich atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-section imaging and p-type doping assessment of ZnO/ZnO:Sb core-shell nanowires by scanning capacitance microscopy and scanning spreading resistance microscopy

ZnO/ZnO:Sb core-shell structured nanowires (NWs) were grown by the metal organic chemical vapor deposition method where the shell was doped with antimony (Sb) in an attempt to achieve ZnO p-type conduction. To directly investigate the Sb doping effect in ZnO, scanning capacitance microscopy (SCM) and scanning spreading resistance microscopy (SSRM) were performed on the NWs' cross-sections mapping their two dimensional (2D) local electrical properties. Although no direct p-type inversion in ZnO was revealed, a lower net electron concentration was pointed out for the Sb-doped ZnO shell layer with respect to the non-intentionally doped ZnO core, indicating an evident compensating effect as a result of the Sb incorporation, which can be ascribed to the formation of Sb-related acceptors. The results demonstrate SCM/SSRM investigation being a direct and effective approach for characterizing radial semiconductor one-dimensional (1D) structures and, particularly, for the doping study on the ZnO nanomaterial towards its p-type realization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The future of electron microscopy

Modern transmission electron microscopes can image individual atoms and molecules. But to unlock new science, the next generation of instruments must look beyond just higher spatial resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae

Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolution beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub-30-nm resolution structural images and similar to 90-nm-resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.

Deng, Junjing↗

Intermittent contact mode piezoresponse force microscopy in a liquid environment

Probing electromechanical coupling in biological systems and electroactive molecules requires high resolution functional imaging. Here, we investigate the feasibility of intermittent contact mode piezoresponse force microscopy based on simultaneous mechanical and electrical probe modulation. It is shown that imaging at frequencies corresponding to the first contact resonance in liquid allows contrast consistent with the electromechanical signal to be obtained for model ferroelectric systems and piezoelectric tooth dentin

Rodriguez, Brian↗

Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens

Abstract Grain boundaries are critical in determining the properties of materials, including mechanical stability, conductivity, and corrosion resistance. The specific properties of materials depend not only on the misorientation of the crystals, the three most commonly characterized parameters, but also on the angle of the grain boundary plane between the two crystals, the final two parameters in the five-parameter macroscopic description of the grain boundary. The method presented here allows for the direct measurement of all five parameters of the grain boundary in a transmission electron microscopy specimen of various morphologies. This is especially applicable to atom probe specimens, where only a single-tilt axis is generally available, allowing the crystallographic description to be matched to the detailed chemical data available in the atom probe tomography. This method provides a platform for efficient grain boundary analysis in unique samples, saving operator time and allowing for ease of acquisition and interpretation in comparison with traditional electron diffraction methods.

Materials Science↗

Soft X-Ray Diffraction Microscopy of a Frozen Hydrated Yeast Cell

We report the first image of an intact, frozen hydrated eukaryotic cell using x-ray diffraction microscopy, or coherent x-ray diffraction imaging. By plunge freezing the specimen in liquid ethane and maintaining it below -170 deg. C, artifacts due to dehydration, ice crystallization, and radiation damage are greatly reduced. In this example, coherent diffraction data using 520 eV x rays were recorded and reconstructed to reveal a budding yeast cell at a resolution better than 25 nm. This demonstration represents an important step towards high resolution imaging of cells in their natural, hydrated state, without limitations imposed by x-ray optics.

60 APPLIED LIFE SCIENCES↗

Combined near- and far-field high-energy diffraction microscopy dataset for Ti-7Al tensile specimen elastically loaded in situ

High-energy diffraction microscopy (HEDM) constitutes a suite of combined X-ray characterization methods, which hold the unique advantage of illuminating the microstructure and micromechanical state of a material during concurrent in situ mechanical deformation. The data generated from HEDM experiments provides a heretofore unrealized opportunity to validate meso-scale modeling techniques, such as crystal plasticity finite element modeling (CPFEM), by explicitly testing the accuracy of these models at the length scales where the models predict their response. Combining HEDM methods with in situ loading under known and controlled boundary conditions represents a significant challenge, inspiring the recent development of a new high-precision rotation and axial motion system for simultaneously rotating and axially loading a sample. In this paper, we describe the initial HEDM dataset collected using this hardware on an alpha-titanium alloy (Ti-7Al) under in situ tensile deformation at the Advanced Photon Source, Argonne National Laboratory. We present both near-field HEDM data that maps out the grain morphology and intragranular crystallographic orientations and far-field HEDM data that provides the grain centroid, grain average crystallographic orientation, and grain average elastic strain tensor for each grain. Finally, we provide a finite element mesh that can be utilized to simulate deformation in the volume of this Ti-7Al specimen.

36 MATERIALS SCIENCE↗

Microstructure Evolution in Ion-Irradiated Oxidized Zircaloy-4 Studied with Synchrotron Radiation Microdiffraction and Transmission Electron Microscopy

The corrosion process (oxidation and hydriding) of zirconium alloy fuel cladding is one of the limiting factors on fuel rod lifetime, particularly for Zircaloy-4. The corrosion rate of this alloy shows indeed a great acceleration at high burnup in light water reactors (LWRs). Understanding the corrosion behavior under irradiation for this alloy is an important technological issue for the safety and efficiency of LWRs. In particular, understanding the effect of irradiation on the metal and oxide layers is a key parameter in the study of corrosion behavior of zirconium alloys. In this study, Zircaloy-4 samples underwent helium and proton ion irradiation up to 0.3 dpa, forming a uniform defect distribution up to 1 pm deep. Both as-received and precorroded samples were irradiated to compare the effect of metal irradiation to that of oxide layer irradiation. After irradiation, samples were corroded to study the impact of irradiation defects in the metal and in preexisting oxide layers on the formation of new oxide layers. Synchrotron X-ray microdiffraction and microfluorescence were used to follow the evolution of oxide crystallographic phases, texture, and stoichiometry both in the metal and in the oxide. In particular, the tetragonal oxide phase fraction, which has been known to play an important role in corrosion behavior, was mapped in both unirradiated and irradiated metals at the submicron scale and appeared to be significantly affected by irradiation. These observations, complemented with electron microscopy analyses on samples in carefully chosen areas of interest, were combined to fully characterize changes caused by irradiation in metal and oxide phases of both alloys.

ion-irradiation↗

Atomic force microscopy and scanning electron microscopy characterization of the controlling of surface morphology of epoxy‐amine‐cured spin‐coated films

Abstract Atomic force microscopy (AFM) was successfully used to study spin‐coated, amine‐cured epoxy film microstructure and morphology. The air‐epoxy and epoxy‐substrate interfaces were examined using tapping‐mode height and phase imaging AFM. The impact of relative humidity on the morphology and microstructure of the surfaces was determined. AFM was able to elucidate the changes on the surface as relative humidity during processing increased. It was observed that large nodular formations formed on the epoxy surface expose to the air but not epoxy surface formed on the substrate in addition to varying regions of more or less compliant structures, which was attributed to carbamate formation caused by the amine curing agent reaction with atmospheric CO 2 . Scanning electron microscopy (SEM) was used to further elucidate interface and interphase morphology of spin‐coated epoxies. Experimentation also demonstrated that post‐curing above the glass transition did not change the morphology structure, suggesting surface structures are “locked‐in.” SEM was used to further elucidate how the interface and interphase change with changing environmental conditions at both the air‐epoxy and epoxy‐substrate interface/interphases, including the impact of atmospheric CO 2 on Marangoni cell formation.

Shenk, Timothy M.↗

Infrared Microscopy as a Probe of Composition within a Model Biofuel Cell Electrode Prepared from Trametes versicolor Laccase

Abstract Infrared microscopy was applied in the study of laccase biofuel cell electrodes that demonstrated high current and power densities traceable to the use of a low equivalent weight (EW), short side chain (Aquivion) ionomer in the catalyst layer. The electrodes were prepared from a biocatalyst ink composed of orientation‐directing anthracene‐modified multi‐walled carbon nanotubes (An‐MWCNTs) in a dispersion of ionomer exchanged by hydrophobic cations. The ink was applied to an electronically conductive carbon felt support that was hot‐pressed to a Nafion‐NRE 212 (51 μm thickness) membrane, forming the framework for an air‐breathing biofuel cell cathode. Infrared microscopy sampling was performed with the use of a micro‐attenuated total reflection probe that enabled spectra to be recorded from ∼32 μm diameter circular spatial regions on the materials investigated. Sensitivity to deformation of the soft polymer membrane‐based materials was assessed through trial experiments on pure membrane samples before approaching the compositionally more complex biofuel cell electrodes. In studies of laccase cathodes, infrared spectral features of enzyme, buffer anions and surrounding An‐MWCNTs were identified. Heterogeneity in the spatial distribution of components and unexpected bands traceable to insoluble copper salts were detected. The results suggest directions for improving electrode activity and bring to light needs for advancing quantitative interpretations.

Liang, Ying↗

Cation ratio fluctuations in Cu 2 ZnSnS 4 at the 20 nm length scale investigated by analytical electron microscopy

Kesterite Cu 2 ZnSn(S,Se) 4 (CZTSSe) is a sustainable material for thin‐film photovoltaics with device efficiencies greater than 12% have been demonstrated. Despite similar crystal structure and polycrystalline film microstructures, there is widespread evidence for larger‐amplitude potential and bandgap fluctuations in CZTS than in the analogous Cu(In,Ga)Se 2 (CIGSe) chalcopyrite material. This disorder is believed to account for a sizable part of the larger open‐circuit voltage ( V OC ) deficit in CZTS devices, yet the detailed origins and length scales of these fluctuations have not been fully elucidated. Herein, we present a transmission electron microscopy study focusing on composition variation within bulk multicrystals of CZTS grown by the travelling heater method (THM). In these slow‐cooled, solution grown crystals we find direct evidence for spatial composition fluctuations of amplitude <1 at.% (∼5 × 10 20 cm −3 ) and thus, explainable by point defects. However, rather than being homogeneously‐distributed we find a characteristic 20 nm length scale for these fluctuations, which sets a definite length scale for band gap and potential fluctuations. At Σ3 grain boundaries, we find no evidence of composition variation compared to the bulk. The finding highlights such variations reported at grain boundaries in polycrystalline thin‐films are direct consequences of processing methods and not intrinsic properties of CZTS itself.

Aguiar, Jeffery A.↗