Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Volumetric imaging of the 3D orientation of cellular structures with a polarized fluorescence light-sheet microscope

Polarized fluorescence microscopy is a valuable tool for measuring molecular orientations in biological samples, but techniques for recovering three-dimensional orientations and positions of fluorescent ensembles are limited. We report a polarized dual-view light-sheet system for determining the diffraction-limited three-dimensional distribution of the orientations and positions of ensembles of fluorescent dipoles that label biological structures. We share a set of visualization, histogram, and profiling tools for interpreting these positions and orientations. We model the distributions based on the polarization-dependent efficiency of excitation and detection of emitted fluorescence, using coarse-grained representations we call orientation distribution functions (ODFs). We apply ODFs to create physics-informed models of image formation with spatio-angular point-spread and transfer functions. We use theory and experiment to conclude that light-sheet tilting is a necessary part of our design for recovering all three-dimensional orientations. We use our system to extend known two-dimensional results to three dimensions in FM1-43-labeled giant unilamellar vesicles, fast-scarlet-labeled cellulose in xylem cells, and phalloidin-labeled actin in U2OS cells. Additionally, we observe phalloidin-labeled actin in mouse fibroblasts grown on grids of labeled nanowires and identify correlations between local actin alignment and global cell-scale orientation, indicating cellular coordination across length scales.

Science & Technology - Other Topics↗

Nanoscale Subsurface Imaging of Nanocomposites via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. The method employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope engages the sample top surface. The cantilever is driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave at the sample surface generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create amplitude and phase-generated images of nanoscale near-surface and subsurface features. RDF-AFUM phase images of LaRC-CP2 polyimide polymer containing embedded nanostructures are presented. A RDF-AFUM micrograph of a 12.7 micrometer thick film of LaRC-CP2 containing a monolayer of gold nanoparticles embedded 7 micrometers below the specimen surface reveals the occurrence of contiguous amorphous and crystalline phases within the bulk of the polymer and a preferential growth of the crystalline phase in the vicinity of the gold nanoparticles. A RDF-AFUM micrograph of LaRC-CP2 film containing randomly dispersed carbon nanotubes reveals the growth of an interphase region at certain nanotube-polymer interfaces.

Cantrell, Sean A.↗

Effect of substrates on microstructure and mechanical properties of nano-eutectic 1080 steel produced by aluminothermic reaction

Nano-eutectic bulk 1080 carbon steel was prepared on glass and copper substrates by an aluminothermic reaction casting. The microstructure of the steel was analyzed by an optical microscope, transmission electron microscopy, an electron probe micro-analyzer, a scanning electron microscope and X-ray diffraction. Results show that the microstructure of the steel consisted of a little cementite and lamellar eutectic pearlite. Average lamellar spacing of the pearlite prepared on copper and glass substrates was about 230 nm and 219 nm, respectively. Volume fraction of the pearlite of the two steels was about 95%. Hardness of the steel was about 229 and 270 HV. Tensile strength was about 610 and 641 MPa and tensile elongation was about 15% and 8%. Compressive strength was about 1043 and 1144 MPa. Compared with the steel prepared on copper substrate, the steel prepared on glass substrate had smaller lamellar spacing of the pearlite phase and higher strength, and low ductility due to the smaller spacing. - Highlights: • 1080-carbon steels were successfully prepared by an aluminothermic reaction casting. • Lamellar spacing of the nanoeutetic pearlite is less than 250 nm. • The compressive strength of the steel is about 1144 MPa. • The tensile ductility of the steel is about 15%.

36 MATERIALS SCIENCE↗

Commissioning of the PRIOR proton microscope

Recently, a new high energy proton microscopy facility PRIOR (Proton Microscope for FAIR Facility for Anti-proton and Ion Research) has been designed, constructed, and successfully commissioned at GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany). As a result of the experiments with 3.5–4.5 GeV proton beams delivered by the heavy ion synchrotron SIS-18 of GSI, 30 μm spatial and 10 ns temporal resolutions of the proton microscope have been demonstrated. A new pulsed power setup for studying properties of matter under extremes has been developed for the dynamic commissioning of the PRIOR facility. This study describes the PRIOR setup as well as the results of the first static and dynamic protonradiography experiments performed at GSI.

36 MATERIALS SCIENCE↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Spectroscopic imaging in electron microscopy

In the scanning transmission electron microscope, multiple signals can be simultaneously collected, including the transmitted and scattered electron signals (bright field and annular dark field or Z-contrast images), along with spectroscopic signals such as inelastically scattered electrons and emitted photons. In the last few years, the successful development of aberration correctors for the electron microscope has transformed the field of electron microscopy, opening up new possibilities for correlating structure to functionality. Aberration correction not only allows for enhanced structural resolution with incident probes into the sub-angstrom range, but can also provide greater probe currents to facilitate mapping of intrinsically weak spectroscopic signals at the nanoscale or even the atomic level. In this issue of MRS Bulletin, we illustrate the power of the new generation of electron microscopes with a combination of imaging and spectroscopy. We show the mapping of elemental distributions at atomic resolution and also the mapping of electronic and optical properties at unprecedented spatial resolution, with applications ranging from graphene to plasmonic nanostructures, and oxide interfaces to biology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Effects of Neutron Irradiation on the Micro/Nano Scale Structure and Fission Product Distribution of TRISO Coated Particle Fuel Kernels from AGR Experiments

The Advanced Reactor Technologies (ART) Program at Idaho National Laboratory (INL) includes the Advanced Gas Reactor (AGR) fuel development and qualification program that consists of fuel fabrication, experiment irradiations, post-irradiation examination (PIE) and safety testing to assess tristructural isotropic (TRISO) fuel performance during normal irradiation and under potential accident conditions. Advanced microscopy work on selected AGR-1 and AGR-2 unirradiated and irradiated fuel specimens is performed as part of the PIE effort. PIE work on fuel from the first experiment irradiation, AGR-1, began at INL in April 2010, and AGR-2 PIE began at INL in July 2014. This work scope includes University of Florida (UF) performing advanced electron microscopy examination and analysis using facilities at the Center for Advanced Energy Studies (CAES), INL or UF’s electron microscopy facilities. Electron microscopic examination and analysis may include scanning transmission electron microscopy (STEM), transmission electron microscopy (TEM), selected area diffraction (SAD), electron energy loss spectroscopy (EELS), electron dispersive spectroscopy (EDS) and atom probe tomography (APT) on the fuel kernels of TRISO-coated fuel particles. The electron microscopy lamellae will be provided by INL and will be available at CAES or Irradiated Materials Characterization Laboratory (IMCL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The solubility of Co in TiO{sub 2} anatase and rutile and its effect on the magnetic properties

Co-doped anatase and rutile bulk-samples prepared by the sol-gel technique are found to be paramagnetic at room-temperature. Only further annealing in Ar/H{sub 2} gas results in a ferromagnetic behavior. X-ray diffraction and electron-microscope studies reveal for low doping levels <4% the formation of Co-doped rutile samples and the formation of CoTiO{sub 3} as a new phase. Co{sub 3}O{sub 4} can be detected in anatase samples with Co doping levels >=4%. The observed Co oxides are reduced by Ar/H{sub 2} to Co metal. The room-temperature ferromagnetism can therefore be traced back to a segregation of metallic Co. - Graphical abstract: Co-doped anatase and rutile bulk-samples prepared by the sol-gel technique are paramagnetic at room-temperature. Further annealing in Ar/H{sub 2} gas results in a ferromagnetic behavior. X-ray diffraction and electron-microscope (SEM, BSE) studies reveal for low doping levels <4% the formation of Co-doped rutile samples and of CoTiO{sub 3} as a new phase. Co{sub 3}O{sub 4} is found in anatase samples with Co doping levels >=4%. The observed Co oxides are reduced by Ar/H{sub 2} to Co metal. The room-temperature ferromagnetism can be traced back to a segregation of metallic Co

36 MATERIALS SCIENCE↗

Hard x-ray micro(spectro)scopy : a powerful tool for the geomicrobiologist.

During the past few decades, the use of electron microscopy approaches - many developed by Terry Beveridge - to probe the physiology of microorganisms has become a mainstay in fields including microbiology, human health, and geomicrobiology. Recent developments of third-generation synchrotron X-ray sources and X-ray-based microscopy approaches for studying microbial systems have proved their utility as complements to the very powerful approaches regularly employed by electron microscopists. In addition, in recent geomicrobiological studies, researchers have begun to take advantage of the strengths of each technique by using the superior spatial resolution of the electron microscope (relative to the X-ray microscope) and the superior elemental sensitivity of the X-ray microscope (relative to the electron microscope), along with the ability of the X-ray microscope to spatially probe the chemical speciation of elements. The benefits of integrating these two nanoprobes for investigating the same microenvironments within a geomicrobial system are far superior to those of independent studies separately employing each probe.

43 PARTICLE ACCELERATORS↗

Indium-bump-free antimonide superlattice membrane detectors on silicon substrates

We present an approach to realize antimonide superlattices on silicon substrates without using conventional Indium-bump hybridization. In this approach, PIN superlattices are grown on top of a 60 nm Al0.6Ga0.4Sb sacrificial layer on a GaSb host substrate. Following the growth, the individual pixels are transferred using our epitaxial-lift off technique, which consists of a wet-etch to undercut the pixels followed by a dry-stamp process to transfer the pixels to a silicon substrate prepared with a gold layer. Structural and optical characterization of the transferred pixels was done using an optical microscope, scanning electron microscopy, and photoluminescence. The interface between the transferred pixels and the new substrate was abrupt, and no significant degradation in the optical quality was observed. An Indium-bump-free membrane detector was then fabricated using this approach. Spectral response measurements provided a 100% cut-off wavelength of 4.3 μm at 77 K. The performance of the membrane detector was compared to a control detector on the as-grown substrate. The membrane detector was limited by surface leakage current. The proposed approach could pave the way for wafer-level integration of photonic detectors on silicon substrates, which could dramatically reduce the cost of these detectors.

Zamiri, M. (ORCID:000000020042735X)↗

Hard x-ray scanning microscopy with coherent radiation: Beyond the resolution of conventional x-ray microscopes

We demonstrate x-ray scanning coherent diffraction microscopy (ptychography) with 10 nm spatial resolution, clearly exceeding the resolution limits of conventional hard x-ray microscopy. The spatial resolution in a ptychogram is shown to depend on the shape (structure factor) of a feature and can vary for different features in the object. In addition, the resolution and contrast are shown to increase with increasing coherent fluence. For an optimal ptychographic x-ray microscope, this implies a source with highest possible brilliance and an x-ray optic with a large numerical aperture to generate the optimal probe beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanopore fabrication and characterization by helium ion microscopy

The Helium Ion Microscope (HIM) has the capability to image small features with a resolution down to 0.35 nm due to its highly focused gas field ionization source and its small beam-sample interaction volume. In this work, the focused helium ion beam of a HIM is utilized to create nanopores with diameters down to 1.3 nm. It will be demonstrated that nanopores can be milled into silicon nitride, carbon nanomembranes, and graphene with well-defined aspect ratio. To image and characterize the produced nanopores, helium ion microscopy and high resolution scanning transmission electron microscopy were used. The analysis of the nanopores' growth behavior allows inferring on the profile of the helium ion beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic infrared analysis by X-ray or electron radiation

An infrared (IR) emission spectroscopy and microscopy apparatus with X-ray excitation or electron excitation and an improved process for extending spatial relation of infrared (IR) microscopy and performing microscopic infrared (IR) analysis by X-ray or electron radiation are provided. By utilizing nanometer sized X-ray beams or electron beams to produce IR emission, the spatial resolution of IR microscopy is extended. Simultaneously performing X-ray or electron-based spectroscopy as well as structural studies are enabled.

42 ENGINEERING↗

Atmospheric pressure scanning transmission electron microscopy

Scanning transmission electron microscope (STEM) images of gold nanoparticles (2.1 nm average diameter) at atmospheric pressure have been recorded through a 0.36 mm thick mixture of CO, O2 and He. This was accomplished using a reaction cell consisting of two electron-transparent silicon nitride membranes mounted on a specially designed specimen rod. Gas flow occurred through plastic tubing from the outside of the microscope to the specimen region and back. Gold nanoparticles of a full width half maximum diameter of 1.0 nm were visible above the background noise and the achieved resolution was 0.5 nm in accordance with calculations of the beam broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved crystalline properties of laser molecular beam epitaxy grown SrTiO{sub 3} by rutile TiO{sub 2} layer on hexagonal GaN

Epitaxial SrTiO{sub 3} films were fabricated by laser molecular beam epitaxy on bare and TiO{sub 2} buffered GaN(0002), respectively. The whole deposition processes were in situ monitored by reflection high energy electron diffraction (RHEED). X-ray diffraction (XRD) was carried out to study the growth orientation and crystalline quality of STO films. The interfacial characters and epitaxial relationships were also investigated by high revolution transition electron microscope and selected area electron diffraction (SAED). According to the RHEED observation, the lowest epitaxy temperature of STO on TiO{sub 2} buffered GaN was decreased compared with the direct deposited one. The epitaxial relationship was (111)[110]STO//(0002)[1120]GaN in both cases as confirmed by RHEED, XRD, and SAED. The full width at half maximum of omega-scan and PHI-scan of STO on TiO{sub 2} buffered GaN was reduced compared with that deposited on bare GaN, indicating that epitaxial quality of STO film is improved by inserting TiO{sub 2} layer. In summary, the lattice mismatch was reduced by inserting rutile TiO{sub 2}. As a result, the crystalline temperature was reduced and enhanced epitaxial quality of STO thin film was obtained.

36 MATERIALS SCIENCE↗

Characterization Of An EBL System: The Influence Of Process Parameters On Thickness Resist And Engraving Shapes

In LIGA process, the low flexibility due to the use of masks might be overcome using the electron beam of a scansion electron microscope (SEM) instead of the synchrotron radiation. In this way, through the vector control of the beam, it is possible to irradiate a specific path on the resist without using any mask. Anyway, it is important to remark that the Electron Beam Lithography (EBL) can not include all the applications of the X-ray LIGA technique but it could be a valid alternative only for some specific uses. In particular, some limits concerning the impression of high thickness resists are expected. An EBL system based on a SEM was recently implemented by the authors and some tests were carried out to characterize the device performances. Aim of this work is to asses the system performances in terms of maximum impressible thickness resist and shape of the engraved entities. Several tests were carried out by varying the resist thickness and the process parameters.

07 ISOTOPE AND RADIATION SOURCES↗