Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics

Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.

Maisto, Pietro M. F.↗

Self-Calibration and Laser Energy Monitor Validations for a Double-Pulsed 2-Micron CO2 Integrated Path Differential Absorption Lidar Application

Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

Refaat, Tamer F.↗

In situ measurements of the NO2/NO ratio for testing atmospheric photochemical models

Simultaneous in situ measurements of NO2, NO, O3, ClO, pressure and temperature have been made for the first time, presenting a unique opportunity to test our current understanding of the photochemistry of the lower stratospere. Data were collected from several flights of the ER-2 aircraft at mid-latitudes in May 1993 during NASA's Stratospheric Photochemistry, Aerosols and Dynamics Expedition (SPADE). The daytime ratio of NO2/NO remains fairly constant at 19 km with a typical value of 0.68 and standard deviation of +/- 17. The ratio observations are compared with simple steady-state calculations based on laboratory-measured reaction rates and modeled NO2 photolysis rates. At each measurement point the daytime NO2/NO with its measurements uncertainty overlap the results of steady-state caculations and associated uncertainty. Possible sources of error are examined in both model and measurements. It is shown that more accurate laboratory determinations of the NO + 03 reaction rate and of the NO2 cross-sections in the 200-220 K temperature range characteristic of the lower stratosphere would allow for a more robust test of our knowledge of NO(X) phtochemistry by reducing significant sources if uncertainties in the interpretation of statospheric measurements.

Jaegle, L.↗

Observing the earth radiation budget from satellites - Past, present, and a look to the future

Satellite measurements of the radiative exchange between the planet earth and space have been the objective of many experiments since the beginning of the space age in the late 1950's. The on-going mission of the Earth Radiation Budget (ERB) experiments has been and will be to consider flight hardware, data handling and scientific analysis methods in a single design strategy. Research and development on observational data has produced an analysis model of errors associated with ERB measurement systems on polar satellites. Results show that the variability of reflected solar radiation from changing meteorology dominates measurement uncertainties. As an application, model calculations demonstrate that measurement requirements for the verification of climate models may be satisfied with observations from one polar satellite, provided there is information on diurnal variations of the radiation budget from the ERBE mission.

House, F. B.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

PLIF Temperature and Velocity Distributions in Laminar Hypersonic Flat-plate Flow

Rotational temperature and velocity distributions have been measured across a hypersonic laminar flat-plate boundary layer, using planar laser-induced fluorescence. The measurements are compared to a finite-volume computation and a first-order boundary layer computation, assuming local similarity. Both computations produced similar temperature distributions and nearly identical velocity distributions. The disagreement between calculations is ascribed to the similarity solution not accounting for leading-edge displacement effects. The velocity measurements agreed to within the measurement uncertainty of 2 % with both calculated distributions. The peak measured temperature was 200 K lower than the computed values. This discrepancy is tentatively ascribed to vibrational relaxation in the boundary layer.

OByrne, S.↗

Optimizing and comparing laser anemometers

Comparisons can be made only if some single valued measure of the quality of each system can be defined. This concept is illustrated here by specifying the quality variable to be the measurement uncertainty in the mean velocity of a turbulent flow in the presence of a large background noise. The Fisher number is used as a figure of merit for some parts of the system. It is noted that in many cases of practical interest, the reciprocal Fisher number gives the actual variance of an estimator. Its principal advantage here is that it can be computed without detailed assumptions about the statistics of the estimated quantities. The concept of a Fisher number is related to the concept of information gain in a measurement. The variance of the measured mean velocity is expressed in terms of the uncertainty for the individual measurements, the measurement rate, and the velocity correlation time. Conditions are given under which the fringe and the two-spot anemometer are optimized.

Edwards, R. V.↗

Trend Detection of Atmospheric Time Series: Incorporating Appropriate Uncertainty Estimates and Handling Extreme Events

This paper is aimed at atmospheric scientists without formal training in statistical theory. Its goal is to, 1) provide a critical review of the rationale for trend analysis of the time series typically encountered in the field of atmospheric chemistry; 2) describe a range of trend-detection methods; and 3) demonstrate effective means of conveying the results to a general audience. Trend detections in atmospheric chemical composition data are often challenged by a variety of sources of uncertainty, which often behave differently to other environmental phenomena such as temperature, precipitation rate, or stream flow, and may require specific methods depending on the science questions to be addressed. Some sources of uncertainty can be explicitly included in the model specification, such as autocorrelation and seasonality, but some inherent uncertainties are difficult to quantify, such as data heterogeneity and measurement uncertainty due to the combined effect of short- and long-term natural variability, instrumental stability, and aggregation of data from sparse sampling frequency. Failure to account for these uncertainties might result in an inappropriate inference of the trends and their estimation errors. On the other hand, the variation in extreme events might be interesting for different scientific questions, for example, the frequency of extremely high surface ozone events and their relevance to human health. In this study we aim to, 1) review trend detection methods for addressing different levels of data complexity in different chemical species; 2) demonstrate that the incorporation of scientifically interpretable covariates can outperform pure numerical curve fitting techniques in terms of uncertainty reduction and improved predictability; 3) illustrate the study of trends based on extreme quantiles that can provide insight beyond standard mean or median based trend estimates; and 4) present an advanced method of quantifying regional trends based on the inter-site correlations of multi-site data. All demonstrations are based on time series of observed trace gases relevant to atmospheric chemistry, but the methods can be applied to other environmental data sets.

Trace gas↗

Measuring Segmented Primary Mirror WFE in the Presence of Vibration and Thermal Drift on the Light-Weighted JWST

The light-weighted design of the Optical Telescope Element (OTE) of the James Webb Telescope (JWST) leads to additional sensitivity to vibration from the ground - an important consideration to the measurement uncertainty of the wavefront error (WFE) in the primary mirror. Furthermore, segmentation of the primary mirror leads to rigid-body movements of segment areas in the WFE. The ground vibrations are minimized with modifications to the test facility, and by the architecture of the equipment supporting the load. Additional special test equipment (including strategically placed isolators, tunable mass dampers, and cryogenic magnetic dampers) mitigates the vibration and the response sensitivity before reaching the telescope. A multi-wavelength interferometer is designed and operated to accommodate the predicted residual vibration. Thermal drift also adds to the measurement variation. Test results of test equipment components, measurement theory, and finite element analysis combine to predict the test uncertainty in the future measurement of the primary mirror. The vibration input to the finite element model comes from accelerometer measurements of the facility with the environmental control pumps operating. One of the isolators have been built and tested to validate the dynamic performance. A preliminary model of the load support equipment and the OTE with the Integrated Science Instrument Module (ISIM) is complete. The performance of the add-on dampers have been established in previous applications. And operation of the multi-wavelength interferometer was demonstrated on a scaled hardware version of the JWST in an environment with vibration and thermal drift.

Whitman, Tony L.↗

AMSD Alignment Sensitivity Analysis

A review of the optical layout for AMSD testing is presented. This includes all optical components from the point source to the mirror under test. The independent sources of error and uncertainty are discussed, and the approach to determining and reducing the measurement uncertainties is presented.

Reardon, Patrick↗

NASA Rotor 37 CFD Code Validation: Glenn-HT Code

In order to advance the goals of NASA aeronautics programs, it is necessary to continuously evaluate and improve the computational tools used for research and design at NASA. One such code is the Glenn-HT code which is used at NASA Glenn Research Center (GRC) for turbomachinery computations. Although the code has been thoroughly validated for turbine heat transfer computations, it has not been utilized for compressors. In this work, Glenn-HT was used to compute the flow in a transonic compressor and comparisons were made to experimental data. The results presented here are in good agreement with this data. Most of the measures of performance are well within the measurement uncertainties and the exit profiles of interest agree with the experimental measurements.

Ameri, Ali A.↗

High Ice Water Content at Low Radar Reflectivity near Deep Convection: Consistency of In Situ and Remote-Sensing Observations with Stratiform Rain Column Simulations - Part I

Occurrences of jet engine power loss and damage have been associated with flight through fully glaciated deep convection at -10 to -50 degrees Centigrade. Power loss events commonly occur during flight through radar reflectivity (Zeta (sub e)) less than 20-30 decibels relative to Zeta (dBZ - radar returns) and no more than moderate turbulence, often overlying moderate to heavy rain near the surface. During 2010-2012, Airbus carried out flight tests seeking to characterize the highest ice water content (IWC) in such low-radar-reflectivity regions of large, cold-topped storm systems in the vicinity of Cayenne, Darwin, and Santiago. Within the highest IWC regions encountered, at typical sampling elevations (circa 11 kilometers), the measured ice size distributions exhibit a notably narrow concentration of mass over area-equivalent diameters of 100-500 micrometers. Given substantial and poorly quantified measurement uncertainties, here we evaluate the consistency of the Airbus in situ measurements with ground-based profiling radar observations obtained under quasi-steady, heavy stratiform rain conditions in one of the Airbus-sampled locations. We find that profiler-observed radar reflectivities and mean Doppler velocities at Airbus sampling temperatures are generally consistent with those calculated from in situ size-distribution measurements. We also find that column simulations using the in situ size distributions as an upper boundary condition are generally consistent with observed profiles of radar reflectivity (Ze), mean Doppler velocity (MDV), and retrieved rain rate. The results of these consistency checks motivate an examination of the microphysical pathways that could be responsible for the observed size-distribution features in Ackerman et al. (2015).

Rain↗

Uncertainty Analysis of the NASA Glenn 8- by 6-Foot Supersonic Wind Tunnel 2019 Characterization Test 14-Foot, 5.8 Percent Test Section Porosity

This paper presents methods and results of a measurement uncertainty analysis that was performed for the 8- by 6-foot Supersonic Wind Tunnel located at the NASA Glenn Research Center. The uncertainty analysis is based on data collected during a characterization test following major structural modifications to the facility and upgrades to the facility’s data and control systems. The statistical methods and engineering judgments used to estimate elemental uncertainties are described in this report. The Monte Carlo method of propagating uncertainty was selected to determine the uncertainty of calculated variables of interest. A description of the Monte Carlo method as applied for this analysis is provided. The primary variable of interest (VOI) for this facility is free stream Mach number. In addition to determining the uncertainty in Mach number, the uncertainty in free stream values of static pressure, total pressure, dynamic pressure, total temperature, static temperature, Reynolds number, and air speed were also calculated. Uncertainty results are presented as random (unpredictable variation in repeated measurements), systematic (potential offset between observed and true value), and total (random and systematic combined) uncertainty for Mach number. Systematic uncertainty results are presented for the other VOIs. Individual uncertainty sources are presented both dimensionally and as percent contributions to uncertainty in all VOIs, to aid in the identification of primary uncertainty sources.

Uncertainty Analysis↗

Fuzzy geometry, entropy, and image information

Presented here are various uncertainty measures arising from grayness ambiguity and spatial ambiguity in an image, and their possible applications as image information measures. Definitions are given of an image in the light of fuzzy set theory, and of information measures and tools relevant for processing/analysis e.g., fuzzy geometrical properties, correlation, bound functions and entropy measures. Also given is a formulation of algorithms along with management of uncertainties for segmentation and object extraction, and edge detection. The output obtained here is both fuzzy and nonfuzzy. Ambiguity in evaluation and assessment of membership function are also described.

Pal, Sankar K.↗

Assessing Uncertainties of a Geophysical Approach to Estimate Surface Fine Particulate Matter Distributions from Satellite-Observed Aerosol Optical Depth

Health impact analyses are increasingly tapping the broad spatial coverage of satellite aerosol optical depth (AOD) products to estimate human exposure to fine particulate matter (PM2.5). We use a forward geophysical approach to derive ground-level PM2.5 distributions from satellite AOD at 1 km2(exp) resolution for 2011 over the northeastern US by applying relationships between surface PM2.5 and column AOD (calculated offline from speciated mass distributions) from a regional air quality model (CMAQ; 12×12 km2(exp) horizontal resolution). Seasonal average satellite-derived PM2.5 reveals more spatial detail and best captures observed surface PM2.5 levels during summer. At the daily scale, however, satellite-derived PM2.5 is not only subject to measurement uncertainties from satellite instruments, but more importantly to uncertainties in the relationship between surface PM2.5 and column AOD. Using 11 ground-based AOD measurements within 10 km of surface PM2.5 monitors, we show that uncertainties in modeled PM2.5∕AOD can explain more than 70 % of the spatial and temporal variance in the total uncertainty in daily satellite-derived PM2.5 evaluated at PM2.5 monitors. This finding implies that a successful geophysical approach to deriving daily PM2.5 from satellite AOD requires model skill at capturing day-to-day variations in PM2.5∕AOD relationships. Overall, we estimate that uncertainties in the modeled PM2.5∕AOD lead to an error of 11 µg m−3(exp) in daily satellite-derived PM2.5, and uncertainties in satellite AOD lead to an error of 8 µg m−3(exp). Using multi-platform ground, airborne, and radiosonde measurements, we show that uncertainties of modeled PM2.5∕AOD are mainly driven by model uncertainties in aerosol column mass and speciation, while model representation of relative humidity and aerosol vertical profile shape contributes some systematic biases. The parameterization of aerosol optical properties, which determines the mass extinction efficiency, also contributes to random uncertainty, with the size distribution being the largest source of uncertainty and hygroscopicity of inorganic salt the second largest. Future efforts to reduce uncertainty in geophysical approaches to derive surface PM2.5 from satellite AOD would thus benefit from improving model representation of aerosol vertical distribution and aerosol optical properties, to narrow uncertainty in satellite-derived PM2.5.

aerosol optical depth↗

In Situ Measurements of the NO2/NO Ratio for Testing Atmospheric Photochemical Models

Simultaneous in situ measurements of NO2, NO, O3, ClO, pressure and temperature have been made for the first time, presenting a unique opportunity to test our current understanding of the photochemistry of the lower stratosphere. Data were collected from several flights of the ER-2 aircraft at mid-latitudes in May 1993 during NASA's Stratospheric Photochemistry, Aerosols and Dynamics Expedition (SPADE). The daytime ratio of NO2/NO remains fairly constant at 19 km with a typical value of 0.68 and standard deviation of +/- 0.17. The ratio observations are compared with simple steady-state calculations based on laboratory-measured reaction rates and modeled NO2 photolysis rates. At each measurement point the daytime NO2/NO with its measurement uncertainty overlap the results of steady-state calculations and associated uncertainty. However, over all the ER-2 flights examined, the model systematically overestimates the ratio by 40% on average. Possible sources of error are examined in both model and measurements. It is shown that more accurate laboratory determinations of the NO + O3 reaction rate and of the NO2 cross-sections in the 200-220 K temperature range characteristic of the lower stratosphere would allow for a more robust test of our knowledge of NO(x) photochemistry by reducing significant sources of uncertainties in the interpretation of stratospheric measurements. The present measurements are compared with earlier observations of the ratio at higher altitudes.

Jaegle, L.↗

Status of knowledge of the extraterrestrial solar 'constant' and spectral distribution

Current knowledge of the total solar flux (the solar constant) and its spectral distribution at the top of the earth's atmosphere is reviewed. The development of pyrheliometers and radiation scales is traced, noting that active cavity pyrheliometers have been developed to reduce measurement uncertainty to within 0.1/%. The weighted mean solar constant from ground-based, aircraft, balloon, spacecraft and sounding rocket observations has been calculated to be 1369 W/sq m. Future observations are planned in order to reduce uncertainty to the 0.1% level required for climatological studies. A comparison of the measurement and models of solar spectral irradiance obtained by Thekaekara (1969, 1974), Arvesen (1969) and Labs and Neckel (1968, 1975) shows that the spectrum of Labs and Neckel is most accurate in the 0.4 to 1.25 micron range, that of Arvesen is best in the 0.3 to 0.4 abd 1.25 to 2.5 micron ranges and the model of Labs and Neckel is best at wavelengths greater than 2.5 microns.

Willson, R. C.↗