Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MODULE ENCAPSULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A candidate low-cost processing sequence for terrestrial silicon solar cell panel

Manufacturing sequence for silicon solar cells using Czochralsky crystal growing techniques in order to produce at a rate of 20 MW per year on a 24-hour per day basis is discussed. Cost analysis of the manufacturing is presented and consideration is given to the following processing decision categories of the manufacturing of an unencapsulated solar cell from a silicon wafer: (1) treatment of the optical surface; (2) formation of the junction(s); and (3) metallization of electrical collectors. The manufacturing of encapsulated solar modules from solar cells, using two glass plates, a low iron front surface, and a standard float glass back plate, is described. Totaling the three major activities of wafer making, cell manufacturing, and module fabrication, the resulting contribution to module price will be 1.945 $/watt.

Bickler, D. B.↗

Encapsulant free-surfaces and interfaces: Critical parameters in controlling cell corrosion

Results are reported of studying the interaction of moisture with photovoltaic (PV) modules and custom-built test coupons in both laboratory and outdoor ambient environments. Characteristics measured included module cell-to-frame leakage currents, encapsulant bulk and surface currents, glass surface currents, and encapsulant/glass interface currents as functions of temperature and humidity. Using a computer model of interelectrode conduction, preferential conduction paths in PVB- and EVA-encapsulated modules are identified. In comparing the results of field and laboratory test environments on identical samples, comments are made about the greater severity of the outdoor environment. Several aspects of water-module interaction, including design strategies and continuing research, are discussed.

Mon, G.↗

Block 2 solar cell module environmental test program

Environmental tests were performed of on 76 solar cell modules produced by four different manufacturers. The following tests were performed: (1) 28 day temperature and humidity; (2) rain and icing; (3) salt fog; (4) sand and dust; (5) vacuum/steam/pressure; (6) fungus; (7) temperature/altitude; and (8) thermal shock. Environmental testing of the solar cell modules produced cracked cells, cracked encapsulant and encapsulant delaminations on various modules. In addition, there was some minor cell and frame corrosion.

Holloway, K. L.↗

Comprehensive study of performance degradation of field‐mounted photovoltaic modules in India

Abstract The All India Survey of Photovoltaic Module Reliability 2014 is an enhanced version of the survey conducted in the previous year, with detailed characterization of PV modules including current‐voltage, infrared and electroluminescence imaging, visual inspection, insulation resistance test and interconnect breakage test. More than a thousand modules were inspected in the field and the main results of the survey are presented in this paper. The average P max degradation rate for the so‐called ‘good’ modules (Group X) is 1.33%/year which is higher than that commonly projected by manufacturers, and widely employed in financial calculations. Modules falling in the ‘not‐so‐good’ category (Group Y) show even higher degradation rates, and it is at least partly due to higher number of micro‐cracks in the modules, and increased degradation of the packaging materials like encapsulant, backsheet, etc. Modules in ‘Hot’ climates degrade faster than modules in the ‘Non‐Hot’ climates. Degradation in fill factor is the primary cause for performance degradation in the young modules (ages <5 years), whereas short‐circuit current degradation is the main contributor to power degradation in the older modules. Small installations (<100 kW p capacity) show higher degradation than large systems, which may be partly due to lack of proper due diligence by the owner at the time of procurement and installation.

Dubey, Rajiv↗

Candidate materials for advanced fire-resistant photovoltaic modules

A cooperative, cost-sharing research effort to develop a technology base required to construct fire-ratable photovoltaic modules has resulted in the identification of several high-temperature, back-surface candidate materials capable of raising the fire-resistance of modules using hydrocarbon encapsulants to Class A and B levels. Advanced experimental module configurations have been developed using back surfaces consisting of Kapton, Tedlar laminates, metal-foils, and fiberglass materials with high-temperature coatings. Test results (October 1984; March 1985; May 1985; and October 1985) indicate that several of these advanced module configurations are capable of achieving Class B fire-resistance levels, while a few configurations can achieve Class A levels. The paper summarizes activities to date, discussing flammability failure mechanisms, time-temperature profiles, and results of Block V environmental exposure tests of a candidate material suitable for both Class B and Class A fire-resistance levels.

Sugimura, R. S.↗

Isolated data processing modules

This disclosure relates to computer systems that isolate data processing modules and methods of operating the same. In one embodiment of a method, a computer system receives a first data processing request for a first data file. The computer system may determine that a first data type of the first data file is supported by an encapsulated data processing module and determine a first communication protocol from a set of communication protocols that can be used to receive the first data file. The computer system can then receive the first data file from the first storage location in accordance with the first communication protocol and the encapsulated data processing module may be executed to convert the first data file in the first data format into second data in a second data format.

Penton, Joshua Michael↗

Encapsulation and backsheet adhesion metrology for photovoltaic modules

Photovoltaic modules are designed to operate for decades in terrestrial environments. However, mechanical stress, moisture, and ultraviolet radiation eventually degrade protective materials in modules, particularly their adhesion properties, eventually leading to reduced solar cell performance. Despite the significance of interfacial adhesion to module durability, currently there is no reliable technique for characterizing module adhesion properties. We present a simple and reproducible metrology for characterizing adhesion in photovoltaic modules that is grounded in fundamental concepts of beam and fracture mechanics. Using width-tapered cantilever beam fracture specimens, interfacial adhesion was evaluated on relevant interfaces of encapsulation and backsheet structures of new and 27-year-old historic modules. The adhesion energy, Gc [J/m 2 ], was calculated from the critical value of the strain energy release rate, G, using G = βP 2 , where β (a mechanical and geometric parameter of the fracture specimen) and P (the experimentally measured critical load) are constants. Under some circumstances where testing may result in cracking of brittle layers in the test specimen, measurement of the delamination length in addition to the critical load was necessary to determine G. Relative to new module materials, backsheet adhesion was 95% and 98% lower for historic modules that were exposed (operated in the field) and unexposed (stored on-site, but out of direct sunlight), respectively. Encapsulation adhesion was 87-94% lower in the exposed modules and 31% lower in the unexposed module. As a result, the metrology presented here can be used to improve module materials and assess long-term reliability.

14 SOLAR ENERGY↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

In-situ determination of moisture- and temperature-driven deflection of an encapsulated Si photovoltaic cell

Module reliability and service lifetime are critical factors in improving photovoltaic system performance and reducing the levelized cost of electricity (LCOE). Soldering and lamination of the cell impart residual stresses that persist over time and superimpose additional loads during operation. This paper demonstrates the use of X-ray Topography (XRT) to image in-situ the dynamic response of a glass/backsheet mini-module upon drying at elevated temperature after saturation at humidity levels compatible with accelerated testing. The local water content in the encapsulant is also determined in-situ over time via Water Reflectometric Detection (WaRD), with diffusion of water in the front (glass side) and rear (backsheet side) resolved. As water diffuses out from the back of the glass/backsheet module, the cell curves towards the backsheet concomitantly. Here we find that the cell edges deflect 40μm out-of-plane with respect to its center while the encapsulant dries, compared to ~100 μm deflection when heating from 25°C to 85°C. The local cell deflections (changes in cell orientation) are correlated with the dynamic loss of water in the backside encapsulant. We conclude that the observed cell deflections are the result of hygroscopic stress induced by the encapsulant upon moisture outdiffusion. Therefore, the cell experiences a continually changing stress state and curvature dependent on local humidity and temperature. Depending on cell architecture and interconnection, this “breathing” mode of the cell may induce wear out and fatigue of the interconnects, affect the electrical connection of cracked pieces or cause failure near the interconnected edges of two cells.

14 SOLAR ENERGY↗

Tests of Solar-Array Encapsulants

Materials tested for degradation by heat and light. Report presents early results of continuing series of photothermal aging tests of some candidate encapsulating materials for solar photovoltaic modules. Objectives of testing program: contribute to development of durable, low-cost encapsulants and predict lifetimes of encapsulated photovoltaic modules placed outdoors. Toward these ends, tests designed to reveal physical and chemical degradation mechanisms that affect encapsulants.

Liang, R. H.↗

Evaluating and predicting molecular mechanisms of adhesive degradation during field and accelerated aging of photovoltaic modules

Extending photovoltaic (PV) module lifetimes beyond 30 years is a goal of significant priority. A challenge that must first be addressed, however, is the development of a predictive reliability model that captures the synergy of terrestrial stressors on module degradation, particularly at encapsulant interfaces. Using a metrology designed specifically for PV modules, a comprehensive study of the widely used ethylene vinyl acetate encapsulant was performed in which encapsulant adhesion was evaluated as a function of environmental stressors (UV exposure, temperature, and humidity) for modules aged both under accelerated lab and internationally located field conditions for months to nearly 3 decades. Mechanical and chemical characterization methods are combined with fundamental polymer reaction engineering to unravel the degradation processes active at the molecular scale that lead to encapsulant delamination. An analytical and modular model framework is put forward enabling the prediction of long-term PV module durability, starting from fundamental principles at the molecular level and explicitly accounting for bond rupture events in the bulk encapsulant and at the encapsulant interfaces. Successful parameter tuning to adhesion data indicates a dominant occurrence of deacetylation, β-scission, and hydrolytic depolymerization, respectively. The model contributes to the longstanding challenge of predicting module lifetimes in any geographic location while minimizing time-consuming and costly aging studies.

14 SOLAR ENERGY↗

Electrical research on solar cells and photovoltaic materials

The flat-plate solar cell array program which increases the service lifetime of the photovoltaic modules used for terrestrial energy applications is discussed. The current-voltage response characteristics of the solar cells encapsulated in the modules degrade with service time and this degradation places a limitation on the useful lifetime of the modules. The most desirable flat-plate array system involves solar cells consisting of highly polarizable materials with similar electrochemical potentials where the cells are encapsulated in polymers in which ionic concentrations and mobilities are negligibly small. Another possible mechanism limiting the service lifetime of the photovoltaic modules is the gradual loss of the electrical insulation characteristics of the polymer pottant due to water absorption or due to polymer degradation from light or heat effects. The mechanical properties of various polymer pottant materials and of electrochemical corrosion mechanisms in solar cell material are as follows: (1) electrical and ionic resistivity; (2) water absorption kinetics and water solubility limits; and (3) corrosion characterization of various metallization systems used in solar cell construction.

Orehotsky, J.↗

An analytical approach to photovoltaic encapsulation system design

This paper describes a set of analytical methods which have been developed to enable quantitative analysis of encapsulation system designs for terrestrial photovoltaic modules. Design factors determined most important include: encapsulant thickness and modules, emissivity of module surface, ribs on substrate modulus, and AR.

Garcia, A., III↗

Flexible, FEP-Teflon covered solar cell module development

Techniques and equipment were developed for the large scale, low-cost fabrication of lightweight, roll-up and fold-up, FEP-Teflon encapsulated solar cell modules. Modules were fabricated by interconnecting solderless single-crystal silicon solar cells and heat laminating them at approximately 300 C between layers of optically clear FEP and to a loadbearing Kapton substrate sheet. Modules were fabricated from both conventional and wraparound contact solar cells. A heat seal technique was developed for mechanically interconnecting modules into an array. The electrical interconnections for both roll-up and fold-up arrays were also developed. The use of parallel-gap resistance welding, ultrasonic bonding, and thermocompression bonding processes for attaching interconnects to solar cells were investigated. Parallel-gap welding was found to be best suited for interconnecting the solderless solar cells into modules. Details of the fabrication equipment, fabrication processes, module and interconnect designs, environmental test equipment, and test results are presented.

Rauschenbach, H. S.↗

Chemical Bonding Technology: Direct Investigation of Interfacial Bonds

This is the third Flat-Plate Solar Array (FSA) Project document reporting on chemical bonding technology for terrestrial photovoltaic (PV) modules. The impetus for this work originated in the late 1970s when PV modules employing silicone encapsulation materials were undergoing delamination during outdoor exposure. At that time, manufacturers were not employing adhesion promoters and, hence, module interfaces in common with the silicone materials were only in physical contact and therefore easily prone to separation if, for example, water were to penetrate to the interfaces. Delamination with silicone materials virtually vanished when adhesion promoters, recommended by silicone manufacturers, were used. The activities related to the direct investigation of chemically bonded interfaces are described.

Koenig, J. L.↗