Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Key properties of mixed cerium and zirconium microspheres prepared by the internal gelation process with previously boiled HMTA and urea

The internal gelation process using previously boiled hexamethylenetetramine-urea was used in exploratory study to produce CeO 2 –ZrO 2 microspheres, which can serve as a simulant for ceramic transuranic fuel particles and as a viable three-way catalyst. The calcined CeO 2 and ZrO 2 microspheres with Barrett–Joyner–Halenda (BJH) pore size and volumes of 8–10 nm and 0.19–0.20 mL/g, respectively, had many more surface cracks than their relatively smooth CeO 2 –ZrO 2 counterparts even though the BJH pore sizes and volumes of mixed oxide spheres were lower at 3 nm and 0.11–0.12 mL/g, respectively. The Brunauer–Emmett–Teller (BET) surface areas for the CeO 2 and ZrO 2 microspheres were 74 and 93 m2/g, respectively, and the BET surface areas for the mixed oxides were much greater at 155–158 m 2 /g, which should improve catalytic performance. Overall, the catalytic activity of each microsphere composition was confirmed through the oxidation of carbon monoxide.

36 MATERIALS SCIENCE↗

Current Role of Selective Internal Irradiation With Yttrium-90 Microspheres in the Management of Hepatocellular Carcinoma: A Systematic Review

Purpose: This article reviews the role of selective internal irradiation (SIR) with yttrium-90 ({sup 90}Y) microspheres for hepatocellular carcinoma (HCC). Methods and Materials: Studies were identified by searching Medline and PubMed databases for articles from 1990 to 2009 using the keywords 'selective internal irradiation,' 'hepatocellular carcinoma,' 'therapeutic embolization,' and 'yttrium-90.' Results: {sup 90}Y microspheres are a safe and well-tolerated therapy for unresectable HCC (median survival range, 7 -21.6 months). The evidence was limited to cohort studies and comparative studies with historical control. {sup 90}Y microspheres have been reported to downstage unresectable HCC to allow for salvage treatments with curative intent, act as a bridging therapy before liver transplantation, and treat HCC with curative intent for patients who are not surgical candidates because of comorbidities. Conclusions: {sup 90}Y microsphere is recommended as an option of palliative therapy for large or multifocal HCC without major portal vein invasion or extrahepatic spread. It can also be used for recurrent unresectable HCC, as a bridging therapy before liver transplantation, as a tumor downstaging treatment, and as a curative treatment for patients with associated comorbidities who are not candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-Based Radiation Dose Correction for Yttrium-90 Microsphere Treatment of Liver Tumors With Central Necrosis

Purpose: The objectives of this study were to model and calculate the absorbed fraction {phi} of energy emitted from yttrium-90 ({sup 90}Y) microsphere treatment of necrotic liver tumors. Methods and Materials: The tumor necrosis model was proposed for the calculation of {phi} over the spherical shell region. Two approaches, the semianalytic method and the probabilistic method, were adopted. In the former method, the range--energy relationship and the sampling of electron paths were applied to calculate the energy deposition within the target region, using the straight-ahead and continuous-slowing-down approximation (CSDA) method. In the latter method, the Monte Carlo PENELOPE code was used to verify results from the first method. Results: The fraction of energy, {phi}, absorbed from {sup 90}Y by 1-cm thickness of tumor shell from microsphere distribution by CSDA with complete beta spectrum was 0.832 {+-} 0.001 and 0.833 {+-} 0.001 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors (where r is the radii of the tumor [T] and necrosis [N]). The fraction absorbed depended mainly on the thickness of the tumor necrosis configuration, rather than on tumor necrosis size. The maximal absorbed fraction {phi} that occurred in tumors without central necrosis for each size of tumor was different: 0.950 {+-} 0.000, and 0.975 {+-} 0.000 for smaller (r{sub T} = 5 cm) and larger (r{sub T} = 10 cm) tumors, respectively (p < 0.0001). Conclusions: The tumor necrosis model was developed for dose calculation of {sup 90}Y microsphere treatment of hepatic tumors with central necrosis. With this model, important information is provided regarding the absorbed fraction applicable to clinical {sup 90}Y microsphere treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Pneumopathy in the Rat After Intravenous Application of {sup 188}Re-Labeled Microspheres

Purpose: To determine the dose dependence and kinetics of pneumopathy after systemic administration of rhenium-188 ({sup 188}Re)-labeled microspheres in a rat model. Methods and Materials: {sup 188}Re-microspheres were injected intravenously into adult Wistar rats (n = 54, age, 8 {+-} 2 months). The rats were divided into 6 groups according to the intended absorbed dose in the lung (maximum 60 Gy). Gamma camera scans were used to estimate the individual whole lung doses. One control group (n = 5) received nonlabeled microspheres. The breathing rate was measured before and weekly after the treatment using whole body plethysmography until 24 weeks. An increase in the breathing rate by 20% compared with the individual pretreatment control value was defined as the quantal endpoint for dose-effect analyses. Results: A biphasic increase in the breathing rate was observed. The first impairment of lung function occurred in Weeks 3-6. For late changes, the interval to onset was clearly dose dependent and was 17 weeks (10-30 Gy) and 10 weeks (50-60 Gy), respectively. The incidence of the response was highly dependent on the estimated lung dose. The median effective dose for an early and late response was virtually identical (19.9 {+-} 0.6 Gy and 20.4 {+-} 3.1 Gy, respectively). A significant correlation was found between the occurrence of an early and a late effect in the same rat, suggesting a strong consequential component. Conclusions: The effects of radiolabeled microspheres can be studied longitudinally in a rat model, using changes in the breathing rate as the functional, clinically relevant response. The isoeffective doses from the present study using radionuclide administration and those from published investigations of homogeneous external beam radiotherapy are almost similar.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Techniques to Prevent Cracking of Amorphous Microspheres Made by the Internal Gelation Process

The internal gelation process has been used to make plutonium gel spheres and zirconium gel spheres with stabilized yttrium. However, attempts to convert these amorphous gel spheres into kernels have failed due to cracking during the subsequent heat treatments. The porosity of the amorphous microspheres is typically not sufficient to permit the gases that are formed during subsequent heat treatments to escape. The microspheres will crack when the internal pressure becomes too great. In this study, several treatment techniques were applied to zirconium microspheres stabilized with yttrium in an effort to reduce or eliminate cracking. A combination of water washes, a pressurized water treatment at 473 K for 3 h, and a Dowanol PM treatment was shown to eliminate the cracking problem with the zirconium microspheres, which were heated to 1438 K.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis of U 3 O 8 and UO 2 microspheres using microfluidics

Uranium-bearing microspheres below 50µm with a narrow size distribution allows for a wider variety of fuel forms. To accommodate the smaller size, gel microspheres with a composition of UO 3 ∙nH 2 O∙mNH 3 were synthesized using microfluidics and subsequently converted to U 3 O 8 and UO 2 . To accommodate the slower flow rates required by microfluidics, a more stable broth was established. Additionally, the gelation studies resulted in a broth that was stable for more than two days at 0°C and for close to 3 h at room temperature while still gelling within 25 s. Synthesis of gel microspheres with a narrow size distribution lasted for 5 h and produced ~0.5 g of air-dried material. The gelled microspheres were converted to U 3 O 8 and UO 2 and with sizes of 50 and 40 µm in diameter, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photochemical preparation of CdS hollow microspheres at room temperature and their use in visible-light photocatalysis

CdS hollow microspheres have been successfully prepared by a photochemical preparation technology at room temperature, using polystyrene latex particles as templates, CdSO{sub 4} as cadmium source and Na{sub 2}S{sub 2}O{sub 3} as both sulphur source and photo-initiator. The process involved the deposition of CdS nanoparticles on the surface of polystyrene latex particles under the irradiation of an 8 W UV lamp and the subsequent removal of the latex particles by dispersing in dichloromethane. Photochemical reactions at the sphere/solution interface should be responsible for the formation of hollow spheres. The as-prepared products were characterized by X-ray diffraction, transmission electron microscopy and scanning electron microscopy. Such hollow spheres could be used in photocatalysis and showed high photocatalytic activities in photodegradation of methyl blue (MB) in the presence of H{sub 2}O{sub 2}. The method is green, simple, universal and can be extended to prepare other sulphide and oxide hollow spheres. -- Graphical abstract: Taking polystyrene spheres dispersed in a precursor solution as templates, CdS hollow microspheres composed of nanoparticles were successfully prepared via a new photochemical route at room temperature. Display Omitted Research highlights: {yields} Photochemical method was first employed to prepare hollow microspheres. {yields} CdS hollow spheres were first prepared at room temperature using latex spheres. {yields} The polystyrene spheres used as templates were not modified with special groups. {yields}The CdS hollow microspheres showed high visible-light photocatalytic activities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Photofunctional hybrid silica microspheres covalently functionalized with metalloporphyrins

The entrapment of metalloporphyrins (with Zn{sup 2+} and Yb{sup 3+}) in silica microspheres is achieved by modification of protoporphyrin IX (Pp-IX) molecules with three different organosilane precursors via the sol-gel method. The obtained hybrid materials are characterized by electronic absorption spectra, Fourier-transform infrared (FT-IR), X-ray diffraction (XRD), {sup 29}Si MAS NMR spectrum, scanning electron microscopy (SEM), nitrogen adsorption/desorption isotherms and thermogravimetric analysis (TGA), and their luminescence properties have also been determined. The results reveal that the obtained porphyrins networks are covalently bonded to the inorganic matrix through the bridging action of the functionalized silica microspheres. Furthermore, it has also been observed that porphyrins molecules located in different environments exhibit different photophysical properties in the visible and near-infrared regions. - Graphical abstract: The entrapment of metalloporphyrins (with Zn{sup 2+} and Yb{sup 3+}) in silica microspheres is achieved by modification of protoporphyrin IX (Pp-IX) molecules with three different organosilane precursors via the sol-gel method. Highlights: Black-Right-Pointing-Pointer Novel functionalized silica microsphere is assembled. Black-Right-Pointing-Pointer Metal phorphyrin derivatives are used as a chemical linkage. Black-Right-Pointing-Pointer Luminescence is obtained in the visible and near infrared regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile synthesis of α-Fe{sub 2}O{sub 3}@ porous hollow yeast-based carbonaceous microspheres for fluorescent whitening agent-VBL wastewater treatment

Porous hollow carbonaceous microspheres (PHCMs) fabricated from yeast cells by hydrothermal treatment have stimulated interest because of their outstanding chemical and physical properties. Herein, the functionalizations of PHCMs by further coating of α-Fe{sub 2}O{sub 3} nanoparticles onto the surface were carried out. The structure of resulted α-Fe{sub 2}O{sub 3}@PHCMs products were characterized by field emission scanning electron microscopy (FE-SEM), energy dispersive spectrometry (EDS), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), and BET specific surface area measurements (BET), respectively. Its promising application was evaluated by the Fenton-like degradation of fluorescent whitening agent-VBL from aqueous solutions. - Graphical abstract: In this work, novel α-Fe{sub 2}O{sub 3}@porous hollow carbonaceous microspheres (α-Fe{sub 2}O{sub 3}@PHCMs) were synthesized through a combination of hydrothermal method and calcinations route and achieved excellent removal efficiency for fluorescent whitening Agent-VBL. - Highlights: • The hybrid α-Fe{sub 2}O{sub 3}@ porous hollow microspheres (PHCMs) were firstly fabricated. • The formation mechanism of α-Fe{sub 2}O{sub 3}@PHCMs microspheres was proposed and verified. • Dithizone played a key role in the synthesis of α-Fe{sub 2}O{sub 3}@PHCMs composites. • A favorable removal for the fluorescent whitening agent-VBL were achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly porous ZnS microspheres for superior photoactivity after Au and Pt deposition and thermal treatment

Graphical abstract: Highly porous ZnS microsphere of size 2–5 μm having large surface area ca. 173.14 m{sup 2} g{sup −1} exhibits superior photocatalytic activity for the oxidation of 4-nitrophenol under UV light irradiation. The rate of photooxidation has been significantly improved by Au and Pt deposition and after sintering, respectively, due to rapid electron acceptance by metal from photoexcited ZnS and growth of crystalline ZnS phase. - Highlights: • Photoactive ZnS microsphere of size 2–5 μm was prepared by hydrothermal route. • Highly porous cubic spherical ZnS crystals possess a large surface area, 173 m{sup 2} g{sup −1}. • 1 wt% Au and Pt photodeposition highly quenched the photoluminescence at 437 nm. • Sintering and metal loading notably improve the photooxidation rate of 4-nitrophenol. • Pt co-catalyst always exhibits superior photoactivity of ZnS microsphere than Au. - Abstract: This work highlights the enhanced photocatalytic activity of porous ZnS microspheres after Au and Pt deposition and heat treatment at 500 °C for 2 h. Microporous ZnS particles of size 2–5 μm with large surface area 173.14 m{sup 2} g{sup −1} and pore volume 0.0212 cm{sup 3} g{sup −1} were prepared by refluxing under an alkaline medium. Photoluminescence of ZnS at 437 nm attributed to sulfur or zinc vacancies were quenched to 30% and 49%, respectively, after 1 wt% Au and Pt loading. SEM images revealed that each ZnS microparticle consist of several smaller ZnS spheres of size 2.13 nm as calculated by Scherrer's equation. The rate of photooxidation of 4-nitrophenol (10 μM) under UV (125 W Hg arc–10.4 mW/cm{sup 2}) irradiation has been significantly improved by Au and Pt deposition followed by sintering due to better electron capturing capacity of deposited metals and growth of crystalline ZnS phase with less surface defects.

36 MATERIALS SCIENCE↗

Low-temperature solvothermal synthesis of EuS hollow microspheres

Graphical abstract: Synthesis of EuS hollow microspheres at low-temperature via solvothermal method for the first time. - Highlights: • We adopt an improved method to synthesise the (Phen)Eu(Et{sub 2}CNS{sub 2}){sub 3} in deionized water. • We have successfully synthesised the EuS hollow microsphere at 230 °C in acetonitrile. • The price of acetonitrile is more inexpensive, so the price of preparation was reduced. - Abstract: EuS crystals are synthesized by low-temperature solvothermal decomposition of the single source precursor complex (Phen)Eu(Et{sub 2}CNS{sub 2}){sub 3} in acetonitrile. X-ray powder diffraction, scanning electron microscopy, granulocyte diameter statistical analysis, surface energy-dispersive X-ray spectroscopy analysis, and UV–vis absorption spectroscopy are used to characterize the structure and properties of the obtained EuS crystals. The results show that the formed EuS crystals are uniform hollow microspheres with a typical cubic phase structure of rock salt and the average particle size of 2.01 μm. The mechanisms for the thermal decomposition of the precursor complex and the formation of the EuS hollow microspheres are postulated based on the experimental observations and previous reports.

36 MATERIALS SCIENCE↗

UV light-assisted fabrication of Cu{sub 0.91}In{sub 0.09}S microspheres sensitized TiO{sub 2} nanotube arrays and their photoelectrochemical properties

Highlights: • Cu{sub 0.91}In{sub 0.09}S microspheres were deposited on TiO{sub 2} NTs by a photodeposition method. • The average diameter of Cu{sub 0.91}In{sub 0.09}S microspheres is 600 nm. • The TiO{sub 2} NTs/CIS shows high photocurrents and visible photocatalytic activity. - Abstract: TiO{sub 2} nanotube arrays sensitized with Cu{sub 0.91}In{sub 0.09}S microspheres (TiO{sub 2} NTs/CIS) were successfully fabricated by a two-step process of anodization and followed by an in situ photodeposition method. The structural investigation by scanning electron microscopy and transmission electron microscopy indicated that the Cu{sub 0.91}In{sub 0.09}S microspheres with average diameter of 600 nm grew on the surface of the TiO{sub 2} nanotubes. The TiO{sub 2} NTs/CIS exhibited more excellent photoelectrochemical properties and photocatalytic activities than those of TiO{sub 2} NTs under visible light irradiation, and the corresponding electron transformation was proposed in detail.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characteristics of Co3O4 and cobalt nanostructured microspheres: Morphology, structure, reduction process, and magnetic properties

Highlights: • The metal cobalt samples consist in both α-Co with a hexagonal close-packed lattice and β-Co face-centered cubic crystal at reduction temperatures 220, 240, 300 and 350 °C. • Co{sub 3}O{sub 4} reduction proceeded in successive stages: water removal, residual salt removal, Co{sub 3}O{sub 4} → CoO and CoO → Co transitions. • Inheritance of morphology may have droplet–Co{sub 3}O{sub 4}–Co association. - Abstract: Nanostructured magnetic cobalt microspheres were synthesized using a two-stage method. First, nanostructured cobalt oxide Co{sub 3}O{sub 4} microspheres were produced by ultrasonic spray pyrolysis at different temperatures from 800 to 1100C. Second, the nanostructured powders obtained were reduced to metal cobalt in an hydrogen atmosphere at different temperatures from 220 to 350C. In this study the evolution of the morphology from Co{sub 3}O{sub 4} nanostructured microspheres to nanostructured Co, resulting from the Co{sub 3}O{sub 4} reduction process, and the structure of metal cobalt, were investigated. It was found that the metal cobalt agglomerates have the same shape and mean diameter (∼ 1,5 μm) as those of the cobalt oxide, Co{sub 3}O{sub 4}. The amount of Co microspheres with smaller diameters decreased with increasing reduction temperature. Also, the β-Co content increased with increasing reduction temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vertical coupling of laser glass microspheres to buried silicon nitride ellipses and waveguides

We demonstrate the integration of Nd{sup 3+} doped barium-titanium-silicate microsphere lasers with a silicon nitride photonic platform. Devices with two different geometrical configurations for extracting the laser light to buried waveguides have been fabricated and characterized. The first configuration relies on a standard coupling scheme, where the microspheres are placed over strip waveguides. The second is based on a buried elliptical geometry whose working principle is that of an elliptical mirror. In the latter case, the input of a strip waveguide is placed on one focus of the ellipse, while a lasing microsphere is placed on top of the other focus. The fabricated elliptical geometry (ellipticity = 0.9) presents a light collecting capacity that is 50% greater than that of the standard waveguide coupling configuration and could be further improved by increasing the ellipticity. Moreover, since the dimensions of the spheres are much smaller than those of the ellipses, surface planarization is not required. On the contrary, we show that the absence of a planarization step strongly damages the microsphere lasing performance in the standard configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D inpatient dose reconstruction from the PET-CT imaging of {sup 90}Y microspheres for metastatic cancer to the liver: Feasibility study

Purpose: The introduction of radioembolization with microspheres represents a significant step forward in the treatment of patients with metastatic disease to the liver. This technique uses semiempirical formulae based on body surface area or liver and target volumes to calculate the required total activity for a given patient. However, this treatment modality lacks extremely important information, which is the three-dimensional (3D) dose delivered by microspheres to different organs after their administration. The absence of this information dramatically limits the clinical efficacy of this modality, specifically the predictive power of the treatment. Therefore, the aim of this study is to develop a 3D dose calculation technique that is based on the PET imaging of the infused microspheres.Methods: The Fluka Monte Carlo code was used to calculate the voxel dose kernel for {sup 90}Y source with voxel size equal to that of the PET scan. The measured PET activity distribution was converted to total activity distribution for the subsequent convolution with the voxel dose kernel to obtain the 3D dose distribution. In addition, dose-volume histograms were generated to analyze the dose to the tumor and critical structures.Results: The 3D inpatient dose distribution can be reconstructed from the PET data of a patient scanned after the infusion of microspheres. A total of seven patients have been analyzed so far using the proposed reconstruction method. Four patients underwent treatment with SIR-Spheres for liver metastases from colorectal cancer and three patients were treated with Therasphere for hepatocellular cancer. A total of 14 target tumors were contoured on post-treatment PET-CT scans for dosimetric evaluation. Mean prescription activity was 1.7 GBq (range: 0.58–3.8 GBq). The resulting mean maximum measured dose to targets was 167 Gy (range: 71–311 Gy). Mean minimum dose to 70% of target (D70) was 68 Gy (range: 25–155 Gy). Mean minimum dose to 90% of target (D90) was 53 Gy (range: 13–125 Gy).Conclusions: A three-dimensional inpatient dose reconstruction method has been developed that is based on the PET/CT data of a patient treated with {sup 90}Y microspheres. It allows for a complete description of the absorbed dose by the tumor and critical structures. It represents the first step in building predictive models for treatment outcomes for patients receiving this therapeutic modality as well as it allows for better analysis of patients' dose response and will ultimately improve future treatment administration.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-116: Dose Response in the Treatment of Unresectable Cholangiocarcinoma with Yttrium-90 Microspheres

Purpose: The purpose of this study is to assess the dose response of radioembolization using yttrium-90 (Y-90) microspheres in patients treated for unresectable cholangiocarcinoma. This study utilized partition dosimetry model for the dose calculation. The results show survival benefit with dose escalation. Methods: Between February 2009 and March 2013, ten patients with pathology proven unresectable cholangiocarcinoma were radioembolized with Y-90 microspheres. Patients underwent initial pre-treatment angiographic assessment for blood flow and 99mTc- MAA for lung shunt evaluation. Activity of Y-90 administration was calculated using the Body Surface Area (BSA) and target volumes which were determined by contouring the pre-treatment MRI/CT images using a radiation therapy treatment planning system. Medical Internal Radiation Dose (MIRD) method was used to assess the dosimetric results of Y90. Partition model based on the tumor to-liver activity uptake estimated from pretreatment 99mTc- MAA study was used to calculate the dose delivered to the target. The variables assessed included: administered dose, toxicity based on clinical changes, imaging based tumor response, and survival. Results: Ten patients were radioembolized with Y-90 microspheres to either one hepatic lobe or both left and right lobes. Patients were stratified by dose. Four patients who received dose greater than 140Gy (p < 0.05) all survived. The corresponding activity they received was greater than 35 mCi. Six out of ten patients died of disease with median survival of 18 weeks (range 12–81wks). Conclusion: Given the growing body of data for Y-90 microspheres in the context of cholangiocarcinoma, radioembolization may become an important treatment modality for an appropriately selected group of patients. Our study further substantiates past studies and shows additional evidence of a survival benefit with dose escalation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-402: Y-90 Microspheres (SIR Spheres) for Treatment of Liver Metastasis : Technique

Purpose: The purpose of this presentation is to discuss the radiation safety and dosimetric technique used for the therapeutic procedure using Y-90 microspheres through intra -arterial administration on patients with liver metastasis Methods: The radiation dosimetry, technique and safety aspects of 14 patients with primary and metastatic liver cancer, treated with Y-90 microsphere (SIR spheres) are discussed. The liver and tumor volumes were determined using the CT and MR scans . The images were imported into the treatment planning system and the liver and tumor volumes and the volume of the liver affected were outlined and the volume calculation was performed using the software. The lung shunt fraction (LSF) and tumor to liver uptake ratio (TLR) were determined using the nuclear medicine SPECT imaging with Tc-99m MAA. The absorbed dose to the target volume in liver was calculated using the following equation:Dose ? (Gy) = C x E? x 5.92 x 10-6 (Gy/s) x T(1/2)(days) x 1.44 x 8.64 x 104 (s) The distribution of activity in the tumor bed was confirmed by post Y-90 administration imaging using the Bremsstrahlung peak at 30% window. The patient and the procedure room were surveyed and radiation safety instructions were given to the patient Results: The tumor volume ranged from 77 cc to 700 cc, tumor to liver uptake ranged from 3 to 12. The lung shunt fraction varied from 1.08% to 9.0%. The activity administered ranged from 1.0GBq to 2.5 GBq, . The radiation survey in contact with the patient ranged from 1.8 mR/hr to 2.5 mR/hr and reading at 1 meter was less than 0.2 mR/hr Conclusion: The technique for radiation dosimetry and radiation safety for Y-90 microsphere therapy is established. The post treatment imaging helped to confirm the distribution of Y-90 microspheres inside the tumor bed.

60 APPLIED LIFE SCIENCES↗

Processing and Characterization of Sol-Gel Cerium Oxide Microspheres

Of interest to space exploration and power generation, Radioisotope Thermoelectric Generators (RTGs) can provide long-term power to remote electronic systems without the need for refueling or replacement. Plutonium-238 (Pu-238) remains one of the more promising materials for thermoelectric power generation due to its high power density, long half-life, and low gamma emissions. Traditional methods for processing Pu-238 include ball milling irregular precipitated powders before pressing and sintering into a dense pellet. The resulting submicron particulates of Pu-238 quickly accumulate and contaminate glove boxes. An alternative and dust-free method for Pu-238 processing is internal gelation via sol-gel techniques. Sol-gel methodology creates monodisperse and uniform microspheres that can be packed and pressed into a pellet. For this study cerium oxide microspheres were produced as a surrogate to Pu-238. The similar electronic orbitals between cerium and plutonium make cerium an ideal choice for non-radioactive work. Before the microspheres can be sintered and pressed they must be washed to remove the processing oil and any unreacted substituents. An investigation was performed on the washing step to find an appropriate wash solution that reduced waste and flammable risk. Cerium oxide microspheres were processed, washed, and characterized to determine the effectiveness of the new wash solution.

36 MATERIALS SCIENCE↗