Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

The effect of magnetic susceptibility and magnetic field strength on porosity estimates determined from low-field nuclear magnetic resonance

The presence of materials with high magnetic susceptibility are known to have an impact on 1H nuclear magnetic resonance (NMR) measurements and in laboratory data this often results in poor estimates of porosity from NMR data. To quantify and understand the cause of the poor NMR porosity estimations, in this laboratory study, we examine the effect of magnetic susceptibility, NMR measurement parameters, and NMR instrument design on NMR measurements. Data were collected with two instruments, each with a different Larmor frequency (2 MHz and 485 kHz), on water-saturated unconsolidated sediments with magnetic susceptibility values ranging from 3.6 × 10 -6 to 7020 × 10 -6 SI. The results show that for materials with low magnetic susceptibility (<378 × 10 -6 SI), the gravimetric porosity is accurately predicted from the NMR measurements. For the samples with high magnetic susceptibility (>987 × 10 -6 SI) the gravimetric porosity is poorly predicted from the 2 MHz NMR measurements made at all echo times (from 0.2 to 3.0 ms). In contrast, the gravimetric porosity is more accurately predicted at an echo time of 0.2 ms for measurements made using the 485 kHz instrument, although at larger echo times (>1.0 ms), the porosity estimate becomes poor. The 485 kHz NMR instrument has non-zero internal magnetic field gradients, similar to those found in borehole instruments, in contrast to the 2 MHz NMR instrument, which has a homogeneous applied magnetic field. Finally, we conclude that differences is the magnetic field strength and higher magnetic field inhomogeneities in the 485 kHz NMR instrument contribute to a reduction of the impact of inhomogeneities in the magnetic field caused by materials with high magnetic susceptibility, allowing for improved porosity estimation. These results indicate that NMR measurements collected at short echo times in low, inhomogeneous static fields, e.g., borehole instruments, may provide accurate estimates of porosity in water saturated sediments, even in the presence of magnetic minerals.

58 GEOSCIENCES↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New limit on dark photon kinetic mixing in the 0.2 – 1.2 μ eV mass range from the Dark E-field Radio experiment

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24 μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

A high-resolution clock phase shifter circuitry for ALTIROC

Abstract A high-resolution clock phase shifter is implemented to adjust the phase of multiple clocks at 40 MHz, 80 MHz, or 640 MHz in the ALTIROC chip. The phase shifter has a coarse-phase shifter and a fine-phase shifter to achieve a step size of 97.7 ps and an adjustable range of 25 ns. The fine delay unit is based on a Delay Locked Loop (DLL) operating at 640 MHz. The phase shifter is fabricated in a 130 nm CMOS process. The area of the phase shifter is 725 µm × 248 µm. The Differential Non-Linearity (DNL) and the Integral Non-Linearity (INL) are ±0.6 LSB and ±0.75 LSB, respectively. The jitter from −25 °C to 20 °C is less than 15.5 ps (RMS), including the contributions from the FPGA clock source and the PLL. The power consumption is 11.2 mW.

Instruments & Instrumentation↗

10 kV Class 14 MHz Isolated Power Supply

This paper presents a single-switch based isolated power supply, utilizing a PCB based core-less transformer to achieve high inter-winding isolation and low common-mode capacitance. Detailed design procedure, considering the transformer to achieve full range ZVS, minimize voltage stress and minimize RMS currents is presented. The proposed methodology is experimentally validated at 14 MHz, with a load variation of 10:1 in output power and a maximum output power of 4 W. The proposed power supply is useful in applications such as MV gate drives and sensors.

Tessaro Andrade, Elvey [ORNL] (ORCID:0009000225919↗

Tuning the dynamics in Fe 3 O 4 nanoparticles for hyperthermia optimization

The AC magnetic susceptibility (ACS) of Fe 3 O 4 nanoparticles was measured between 10 kHz and 4 MHz at different temperatures and in applied DC fields. In this frequency range, magnetostatic interactions impact magnetization dynamics even for dilute assemblies. The ACS spectrum of relaxation frequencies changes both with temperature and the addition of a small DC field. Because both the relaxation peak frequency and amplitude can be tuned with the DC field, these results could be applied to magnetic hyperthermia applications to optimize heat delivery.

Physics↗

Ion dynamics in hexagonal boron nitride ionogel electrolytes

Ionogel electrolytes incorporating exfoliated hexagonal boron nitride (hBN) nanoplatelets are promising materials for next-generation energy storage systems. However, detailed understanding of their ion transport properties at the molecular level remains limited. This study employs diffusion and relaxation nuclear magnetic resonance (NMR) techniques, including fast-field cycling (FFC) NMR, to investigate the dynamics of ionic species in hBN-ionogels. By spanning a broad frequency range from 30 kHz using FFC NMR to high-field NMR (500–800 MHz), we reveal distinct relaxation mechanisms governing ion dynamics in ionogels with and without lithium salts. Our results highlight the role of hBN in modulating molecular rotation and translational motion, significantly affecting 1 H and 19 F relaxation profiles. The presence of Li + alters the dynamic behavior in ionogels, enhancing anion mobility at the interface. Notably, 7 Li relaxation reveals strong interactions with the hBN surface that cannot be detected by diffusion NMR. Furthermore, these findings underscore the importance of spanning a broad frequency range in NMR studies of ionogels and provide critical insights into optimizing their design as novel electrolytes.

Electrolytes↗

An Automatic Processing Framework for In Situ Determination of Ecohydrological Root Water Content by Ground-Penetrating Radar

This report concerns Root water content (RWC) as a vital component in water flux in soil-plant-atmosphere continuum. Knowledge of RWC helps to better understand the root function and the soil-root interaction and improves water cycle modeling. However, due to the lack of appropriate methods, field monitoring of RWC is seriously constrained. In this study, we used ground-penetrating radar (GPR), a common geophysical technique, to characterize RWC of coarse roots noninvasively. An automatic GPR data processing framework was proposed to (1) identify hyperbolic root reflections and locate roots in GPR images and (2) extract waveform parameters from the reflected wave of identified roots. These waveform parameters were then used to establish an empirical model and a semiempirical model to determine RWC. We validated the developed models using GPR root data at three antenna center frequencies (500 MHz, 900 MHz, and 2 GHz) that were produced from simulation experiments (with RWC ranging from 70% to 150%) and field experiments in sandy soils (with RWC ranging from 66% to 144%). Our results show that both the empirical and the semiempirical models achieved a good performance in estimating RWC with similar accuracy, i.e., the prediction error [root-mean-square error (RMSE)] was less than 8% for the simulation data and 12% for the field data. For both models, the accuracy of RWC estimation was the highest when applied to 2-GHz data. This study renders a new opportunity to determine RWC under field conditions that enhances the application of GPR for root study and the understanding and modeling of ecohydrology in the rhizosphere.

54 ENVIRONMENTAL SCIENCES↗

A Fast Mechanical Tuner for SRF Cavities

There is a particular need for fast tuners and phase shifters for advanced superconducting accelerator RF systems. The tuners based on ferrite, ferroelectric and piezo materials are commonly used. However, those methods suffer from one or another issue of high power loss, slow response, and narrow tuning range. We propose a robust, fast (up to ~5 MHz/sec), high efficient mechanical tuner for SRF cavities operating at the frequency 50 MHz. We develop an external mechanical tuner that is strongly coupled to the cavity. The tuner design represents a trade-off of high efficiency (low RF losses and low heat flux) and frequency tunability range. Our approach solves this trade-off issue. We propose RF design which exploits two coupled resonators so that a main high-field cavity is controlled with a small tunable resonator with a flexible metallic wall operating in a relatively low RF field. Simulations, carried out for a 7.5 MV/m 50 MHz SRF Quarter Wave Resonator (QWR), show that frequency tunability at level 10⁻³ is obtainable.

43 PARTICLE ACCELERATORS↗

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The MeerKAT Galaxy Cluster Legacy Survey I. Survey Overview and Highlights

MeerKAT’s large number (64) of 13.5 m diameter antennas, spanning 8 km with a densely packed 1 km core, create a powerful instrument for wide-area surveys, with high sensitivity over a wide range of angular scales. The MeerKAT Galaxy Cluster Legacy Survey (MGCLS) is a programme of long-track MeerKAT L-band (900–1670 MHz) observations of 115 galaxy clusters, observed for ~6–10 h each in full polarisation. The first legacy product data release (DR1), made available with this paper, includes the MeerKAT visibilities, basic image cubes at ~8" resolution, and enhanced spectral and polarisation image cubes at ~8" and 15" resolutions. Typical sensitivities for the full-resolution MGCLS image products range from ~3–5 μJy beam –1 . The basic cubes are full-field and span 2° × 2°. The enhanced products consist of the inner 1.2° × 1.2° field of view, corrected for the primary beam. The survey is fully sensitive to structures up to ~10' scales, and the wide bandwidth allows spectral and Faraday rotation mapping. Relatively narrow frequency channels (209 kHz) are also used to provide H I mapping in windows of 0 < z < 0.09 and 0.19 < z < 0.48. Here, in this paper, we provide an overview of the survey and the DR1 products, including caveats for usage. We present some initial results from the survey, both for their intrinsic scientific value and to highlight the capabilities for further exploration with these data. These include a primary-beam-corrected compact source catalogue of ~626 000 sources for the full survey and an optical and infrared cross-matched catalogue for compact sources in the primary-beam-corrected areas of Abell 209 and Abell S295. We examine dust unbiased star-formation rates as a function of cluster-centric radius in Abell 209, extending out to 3.5 R 200 . We find no dependence of the star-formation rate on distance from the cluster centre, and we observe a small excess of the radio-to-100 μm flux ratio towards the centre of Abell 209 that may reflect a ram pressure enhancement in the denser environment. We detect diffuse cluster radio emission in 62 of the surveyed systems and present a catalogue of the 99 diffuse cluster emission structures, of which 56 are new. These include mini-halos, halos, relics, and other diffuse structures for which no suitable characterisation currently exists. We highlight some of the radio galaxies that challenge current paradigms, such as trident-shaped structures, jets that remain well collimated far beyond their bending radius, and filamentary features linked to radio galaxies that likely illuminate magnetic flux tubes in the intracluster medium. We also present early results from the H I analysis of four clusters, which show a wide variety of H I mass distributions that reflect both sensitivity and intrinsic cluster effects, and the serendipitous discovery of a group in the foreground of Abell 3365.

79 ASTRONOMY AND ASTROPHYSICS↗