Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Metastability bounds on flavor-violating trilinear soft terms in the MSSM

The vacuum stability bounds on flavor-violating trilinear soft terms are revisited from the viewpoint that one should not ban a standard-model-like false vacuum as long as it is long-lived on a cosmological time scale. The vacuum transition rate is evaluated numerically by searching for the bounce configuration. Like stability, a metastability bound does not decouple even if sfermion masses grow. Apart from being more generous than stability, the new bounds are largely independent of Yukawa couplings except for the stop trilinears. With vacuum longevity imposed on otherwise arbitrary LR insertions, it is found that a super flavor factory has the potential to probe sparticle masses up to a few TeV through B and {tau} physics whereas the MEG experiment might cover a far wider range. In the stop sector, metastability is more restrictive than any existing experimental constraint such as from electroweak precision data. Also discussed are dependency on other parameters and reliability under radiative corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs quadruplet for the type III seesaw model and implications for {mu}{yields}e{gamma} and {mu}-e conversion

In the type III seesaw model, the heavy neutrinos are contained in leptonic triplet representations. The Yukawa couplings of the triplet fermion and the left-handed neutrinos with the doublet Higgs field produce the Dirac mass terms. Together with the Majorana masses for the leptonic triplets, the light neutrinos obtain nonzero seesaw masses. We point out that it is also possible to have a quadruplet Higgs field to produce the Dirac mass terms to facilitate the seesaw mechanism. The vacuum expectation value of the quadruplet Higgs is constrained to be small by electroweak precision data. Therefore, the Yukawa couplings of a quadruplet can be much larger than those for a doublet. We also find that unlike the usual type III seesaw model where at least two copies of leptonic triplets are needed, with both doublet and quadruplet Higgs representations, just one leptonic triplet is possible to have a phenomenologically acceptable model because light neutrino masses can receive sizable contributions at both tree and one-loop levels. Large Yukawa couplings of the quadruplet can induce observable effects for lepton flavor violating processes {mu}{yields}e{gamma} and {mu}-e conversion. Implications of the recent {mu}{yields}e{gamma} limit from MEG and the limit on {mu}-e conversion on Au are also given. Some interesting collider signatures for the doubly charged Higgs boson in the quadruplet are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid xenon detectors for particle physics and astrophysics

This article reviews the progress made over the last 20 years in the development and applications of liquid xenon detectors in particle physics, astrophysics, and medical imaging experiments. A summary of the fundamental properties of liquid xenon as radiation detection medium, in light of the most current theoretical and experimental information is first provided. After an introduction of the different type of liquid xenon detectors, a review of past, current, and future experiments using liquid xenon to search for rare processes and to image radiation in space and in medicine is given. Each application is introduced with a survey of the underlying scientific motivation and experimental requirements before reviewing the basic characteristics and expected performance of each experiment. Within this decade it appears likely that large volume liquid xenon detectors operated in different modes will contribute to answering some of the most fundamental questions in particle physics, astrophysics, and cosmology, fulfilling the most demanding detection challenges. From detectors based solely on liquid xenon (LXe) scintillation, such as in the MEG experiment for the search of the rare ''{mu}{yields}e{gamma}'' decay, currently the largest liquid xenon detector in operation, and in the XMASS experiment for dark matter detection, to the class of time projection chambers which exploit both scintillation and ionization of LXe, such as in the XENON dark matter search experiment and in the Enriched Xenon Observatory for neutrinoless double beta decay, unrivaled performance and important contributions to physics in the next few years are anticipated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Energy Output Marx Generator Design

High Energy Output Marx Generator Design a design of a six stage Marx generator that has a unipolar pulse waveform of 200 kA in a 50×500 microsecond waveform is presented. The difficulties encountered in designing the components to withstand the temperatures and pressures generated during the output pulse are discussed. The unique methods and materials used to successfully overcome these problems are given. The steps necessary to increase the current output of this Marx generator design to the meg-ampere region or higher are specified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A mobile test facility based on a magnetic cumulative generator to study the stability of the power plants under impact of lightning currents

The report presents the results of the development and field testing of a mobile test facility based on a helical magnetic cumulative generator (MCGTF). The system is designed for full-scale modeling of lightning currents to study the safety of power plants of any type, including nuclear power plants. Advanced technologies of high-energy physics for solving both engineering and applied problems underlie this pilot project. The energy from the magnetic cumulative generator (MCG) is transferred to a high-impedance load with high efficiency of more than 50% using pulse transformer coupling. Modeling of the dynamics of the MEG that operates in a circuit with lumped parameters allows one to apply the law of inductance output during operation of the MCG, thus providing the required front of the current pulse in the load without using any switches. The results of field testing of the MCGTF are presented for both the ground loop and the model load. The ground loop generates a load resistance of 2–4 Ω. In the tests, the ohmic resistance of the model load is 10 Ω. It is shown that the current pulse parameters recorded in the resistive-inductive load are close to the calculated values.

42 ENGINEERING↗

The Mu2e experiment at Fermilab: Design and status

The Mu2e experiment at Fermilab will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus. The dynamics of such charged lepton flavour violating (CLFV) process is a twobody decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates Rμe of ≤ 6 × 10 -17 (@90% C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for μ → eγ decay at MEG as well as the direct searches for new physics at the LHC. Indeed, such a CLFV process probes new physics at a scale inaccessible to direct searches at either present or planned high energy colliders. Observation of a signal will be a clear evidence for new physics beyond the Standard Model. To search for the muon conversion process, a very intense pulsed beam of negative muons (~ 10 10 μ/s) is stopped on an aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and an electromagnetic calorimeter consisting of arrays of CsI crystals. An external veto for cosmic rays is surrounding the detector solenoid. In 2016, Mu2e has passed the final approval stage from DOE and has started its construction phase. Data collection is planned for the end of 2021. Lastly, an overview of the physics motivations for Mu2e, the current status of the experiment and design of the muon beam-line and the detector is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e experiment

Mu2e will search for coherent, neutrinoless conversion of muons into electrons in the nucleus field of aluminum with a sensitivity improvement of a factor of 10,000 over existing limits. Probing the charged lepton flavor-violating reaction at such sensitivity may uncover new physics at a scale unreachable by direct searches at current or planned high-energy colliders. The experiment complements and extends the current studies at MEG-II and the LHC. I will present the physics motivation for Mu2e, as well as the design and construction status of the experiment.

Gaponenko, Andrei↗

The Mu2e Experiment and Progress in the Year 2024

The Mu2e Experiment is a search for Charged Lepton Flavor Violation (CLFV) in the process of a coherent neutrinoless mu- N -> e- N transition. This process is allowed under the Standard Model in the presence of neutrino mixing; albeit, at unobservable rates (branching ratio below 10-50). The sensitivity of the Mu2e experiment is a factor of 104 improvement over the current limit. This search both compliments and extends current searches for muon to electron+gamma at MEG and new physics searches at the LHC. Another interesting process that Mu2e will search for is the neutrionless conversion of stopped negative muons into positrons: mu- N -> e+ N'. This process violates both lepton flavor and lepton number (LNV) and would provide proof that neutrinos are Majorana particles. Progress has been made in many areas in preparation for beam. A description of the Mu2e Experiment and a synopsis of this experiment s progress in the year 2024 towards data collection will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Ultrafast Charge Transfer Dynamics in Heterostructured Nanomaterials

The increasing demand for renewable and low‐cost energy has triggered a vast amount of research aimed at developing, characterizing and optimizing materials that can efficiently convert sun light into useful chemical energy in the form of electricity or chemical fuels. So‐ called quantum dot sensitized solar cell (QDSC) materials have gained much attention in recent years based on the advantageous physicochemical properties of semiconducting quantum dots (QDs) as sensitizers, as well as their promising potential to increase the conversion efficiency beyond the Shockley‐Queisser limit of ∼33% by making use of hot‐electron transfer (HET) routes and multiple exciton generation (MEG). By finely tuning the size of the QDs, the band gap can be carefully aligned to the metal oxide (MO) conduction band such that charge transfer from the photoexcited QD is thermodynamically favorable.

14 SOLAR ENERGY↗

The Mu2e crystal calorimeter

The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $\mu^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021. The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates %\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{\mu e} = \frac{\mu^- + A(Z,N) \to e^- +A(Z,N)}{\mu^- + A(Z,N) \to \nu_{\mu} ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for $\mu \to e \gamma$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} \mu/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e: A Search for Charged Lepton Flavor Violation in $μN → eN$ Conversion with a Sensitivity $< 10^{-16}$

Mu2e will search for coherent, neutrino-less conversion of muons into electrons in the field of a nucleus with a sensitivity improvement of a factor of 10,000 over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable with direct searches at either present or planned high energy colliders. The experiment both complements and extends the current studies at MEG and at the LHC.We present the physics motivation for Mu2e, as well as the design of the muon beamline, tracking spectrometer, and calorimeter. The Mu2e experiment is under design and construction at the Muon Campus of Fermilab. The experiment will begin near the end of 2020 with 3 years of running from 2021 to 2024.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and perspectives of cLFV at Mu2e

Flavor physics offers a promising way to explore fundamental aspects of the standard model, such asthe mass hierarchy and electroweak symmetry breaking. Within this field, Charged Lepton FlavorViolation (CLFV) stands out as a phenomenon that is strongly suppressed in the Standard Model,making it an excellent probe for potential new physics. Ongoing CLFV experiments, includingMu2e, COMET, MEG, and Mu3e, are preparing for data collection in the coming decade. Amongthe possible searches in the muon sector (𝜇 → 𝑒𝛾, mu3e and muon conversion), two muonconversion experiments will start taking data in few years: Mu2e at Fermilab and COMET atJPArk. Both of them aim to improve the current sensitivity by several orders of magnitude. Thisviolation of charged lepton flavor presents an opportunity to explore novel physics on a scale notcurrently accessible through direct searches at contemporary or planned high-energy colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

A high-sensitivity tunable two-beam fiber-coupled high-density magnetometer with laser heating

Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz 1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. Here, this magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the application of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz 1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged Lepton Flavor Violating Experiments with Muons

We report on the status of charged lepton flavor violating (CLFV) experiments with muons. We focus on the three "golden channels": $\mu^{+} \rightarrow e^{+} \gamma$, $\mu^{+} \rightarrow e^{+} e^{-} e^{+}$ and $\mu^{-} N \rightarrow e^{-} N$. The collection of upcoming experiments aim for sensitivity improvements up to $10^{4}$ with respect to previous searches. The MEG II experiment, searching for $\mu^{+} \rightarrow e^{+} \gamma$, is currently in its 4th year of physics data-taking with a published result from its first year of data. The Mu3e experiment is an upcoming experiment searching for $\mu^{+} \rightarrow e^{+} e^{-} e^{+}$ with plans of physics data-taking as soon as 2025. The Mu2e and COMET experiments are upcoming searches for $\mu^{-} N \rightarrow e^{-} N$ with the goal of physics data-taking starting in 2027 and 2026 respectively. This proceeding summarizes the signal signature, expected background, resolutions, and timelines for the mentioned searches.

Palo, Dylan [Fermilab]↗

Acid rain monitoring in East-Central Florida from 1977 to present

Rainfall has been collected on the University of Central Florida campus and at the Kennedy Space Center over a 12 year period. The chemical composition has been determined and summarized by monthly, annual periods, and for the entire 12 year period at both locations. The weighted average pH at each site is 4.58; however, annual weighted average pH has been equal to or above the 12 year average during six of the past eight years. Nitrate concentrations have increased slightly during recent years while excess sulfate concentrations have remained below the 12 year weighted average during six of the past seven years. Stepwise regression suggests that sulfate, nitrate, ammonium ion and calcium play major roles in the description of rainwater acidity. Annual acid deposition and annual rainfall have varied from 20 to 50 meg/(m(exp 2) year) and 100 to 180 cm/year, respectively. Sea salt comprises at least 25 percent of the total ionic composition.

Madsen, B. C.↗

Analysis and visualization of single-trial event-related potentials

In this study, a linear decomposition technique, independent component analysis (ICA), is applied to single-trial multichannel EEG data from event-related potential (ERP) experiments. Spatial filters derived by ICA blindly separate the input data into a sum of temporally independent and spatially fixed components arising from distinct or overlapping brain or extra-brain sources. Both the data and their decomposition are displayed using a new visualization tool, the "ERP image," that can clearly characterize single-trial variations in the amplitudes and latencies of evoked responses, particularly when sorted by a relevant behavioral or physiological variable. These tools were used to analyze data from a visual selective attention experiment on 28 control subjects plus 22 neurological patients whose EEG records were heavily contaminated with blink and other eye-movement artifacts. Results show that ICA can separate artifactual, stimulus-locked, response-locked, and non-event-related background EEG activities into separate components, a taxonomy not obtained from conventional signal averaging approaches. This method allows: (1) removal of pervasive artifacts of all types from single-trial EEG records, (2) identification and segregation of stimulus- and response-locked EEG components, (3) examination of differences in single-trial responses, and (4) separation of temporally distinct but spatially overlapping EEG oscillatory activities with distinct relationships to task events. The proposed methods also allow the interaction between ERPs and the ongoing EEG to be investigated directly. We studied the between-subject component stability of ICA decomposition of single-trial EEG epochs by clustering components with similar scalp maps and activation power spectra. Components accounting for blinks, eye movements, temporal muscle activity, event-related potentials, and event-modulated alpha activities were largely replicated across subjects. Applying ICA and ERP image visualization to the analysis of sets of single trials from event-related EEG (or MEG) experiments can increase the information available from ERP (or ERF) data. Copyright 2001 Wiley-Liss, Inc.

Non-NASA Center↗