Shielding Design of Gantry 3 - Paper 104

The proton therapy complex at PSI will be extended with a third irradiation facility, Gantry 3. This new Gantry is being built in the south-west area of the experimental hall of the High Intensity Proton Accelerator (HIPA) complex at PSI. Originally, it was planned to restrict the operation of Gantry 3 to 180 deg. by hardware means, but due to new considerations, the Gantry will be able to be moved in the full 360 deg. field. This change requires the redesign and reinforcement of the too weak shielding in the north and east directions. Additionally, the isocenter has been fixed, thus allowing for the exact calculation of distances, angles and effective shielding thicknesses in order to determine the dose rates more accurately. For these calculations a fast and simple semi-empirical analytical formula and the more time consuming, but also more sophisticated best estimate code MCNPX 2.7.0 have been used. The two methods used for the calculations of the dose rates are in good agreement. Generally, the analytical method provides the results instantaneously, but predicts higher dose rate values of a factor 2-3 larger than the Monte-Carlo particle transport code MCNPX. Thus, MCNPX should be used to verify the final design of the shielding, including additional details in the simulation model (e.g. ventilation shafts) which have weakening effect on the shielding. Such influences are hard to quantify analytically. The analytical method fails when the geometry becomes complex, i.e. when it is difficult to determine the effective length of the shielding; in the case of position 10 the shielding effect of the inner wall is difficult to quantify. Due to the change of the specification of the Gantry, the shielding was reinforced at the north and east sides, and the HC-layer was extended in front of the control room. The dose rates are acceptable with the new shielding layout. A detailed dose rate mapping is planned in the commissioning phase of Gantry 3 to verify the simulation results and to identify any remaining weak spots of the shielding. (authors)

43 PARTICLE ACCELERATORS↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Angular-resolution and material-characterization measurements for a dual-particle imaging system with mixed-oxide fuel

A dual-particle imaging (DPI) system, capable of simultaneously imaging fast neutrons and gamma rays, has been operated in the presence of mixed-oxide (MOX) fuel to assess the system's angular resolution and material-characterization capabilities. The detection principle is based on the scattering physics of neutrons (elastic scattering) and gamma rays (Compton scattering) in organic and inorganic scintillators. The detection system is designed as a combination of a two-plane Compton camera and a neutron-scatter camera. The front plane consists of EJ-309 liquid scintillators and the back plane consists of interleaved EJ-309 and NaI(Tl) scintillators. MCNPX-PoliMi was used to optimize the geometry of the system and the resulting prototype was built and tested using a Cf-252 source as an SNM surrogate. A software package was developed to acquire and process data in real time. The software was used for a measurement campaign to assess the angular resolution of the imaging system with MOX samples. Measurements of two MOX canisters of similar isotopics and intensity were performed for 6 different canister separations (from 5° to 30°, corresponding to distances of 21 cm and 131 cm, respectively). The measurements yielded a minimum separation of 20° at 2.5 m (86-cm separation) required to see 2 separate hot spots. Additionally, the results displayed good agreement with MCNPX-PoliMi simulations. These results indicate an angular resolution between 15° and 20°, given the 5° step. Coupled with its large field of view, and its capability to differentiate between spontaneous fission and (α,n) sources, the DPI system shows its potential for nuclear-nonproliferation applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a mixed high-energy spallation neutron–proton field using monoisotopic activation detectors

In this paper, we used monoisotopic Co, Au, and Bi threshold activation detectors to characterize the high-energy ( > 5 MeV) portion of a mixed spallation neutron–proton (n/p) field. The field was produced by irradiating the natural uranium target–blanket subcritical assembly Quinta with 660-MeV protons from Phasotron accelerator at the Joint Institute for Nuclear Research (JINR) in Dubna. Experimental yields of the (n,x) and (p,x) reactions were compared to the calculated reaction rates, which represent the convolution of particle flux and reaction cross section. The flux was simulated using the radiation transport code MCNPX 2.7.0, and the cross sections were extracted from the following three sources: the intranuclear cascade model INCL4.2, the phenomenological spherical optical model from TALYS-1.8, and the evaluated nuclear data file TENDL-2015. We show that, in most cases, the evaluated data provide a closer agreement with the experimental data in comparison with INCL4.2 model, which is an integral part of MCNPX. Finally, our results bring a contribution to those fields of physics research that utilize computer prediction of neutron generation in the energy range of tens to hundreds MeV, such as the medical radioisotope production, radiation shielding of spallation neutron sources, and nuclear transmutation in accelerator-driven systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗

Nuclear Resonance Fluorescence for Materials Assay

This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX's photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Resonance Fluorescence for Materials Assay

This paper discusses the use of nuclear resonance fluorescence (NRF) techniques for the isotopic and quantitative assaying of radioactive material. Potential applications include age-dating of an unknown radioactive source, pre- and post-detonation nuclear forensics, and safeguards for nuclear fuel cycles Examples of age-dating a strong radioactive source and assaying a spent fuel pin are discussed. The modeling work has ben performed with the Monte Carlo radiation transport computer code MCNPX, and the capability to simulate NRF has bee added to the code. Discussed are the limitations in MCNPX?s photon transport physics for accurately describing photon scattering processes that are important contributions to the background and impact the applicability of the NRF assay technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pile-up rejection for plutonium experiments with solution-grown stilbene

A solution-grown stilbene detector was used in several experiments with plutonium samples including plutonium oxide, mixed oxide, and plutonium metal samples. Neutrons from different reactions and plutonium isotopes are accompanied by numerous gamma rays especially by the 59-keV gamma ray of 241Am. Identifying neutrons correctly is important for nuclear nonproliferation applications and makes neutron/gamma discrimination and pile-up rejection necessary. Each experimental dataset is presented with and without pile-up filtering using a previously developed algorithm. The experiments were simulated using MCNPX-PoliMi, a Monte Carlo code designed to accurately model scintillation detector response. Collision output from MCNPX-PoliMi was processed using the specialized MPPost post-processing code to convert neutron energy depositions event-by-event into light pulses. The model was compared to experimental data after pulse-shape discrimination identified waveforms as gamma ray or neutron interactions. We show that the use of the digital pile-up rejection algorithm allows for accurate neutron counting with stilbene to within 2% even when not using lead shielding

Bourne, M. M.↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance upgrades to the MCNP6 burnup capability for large scale depletion calculations

The first MCNP based inline Monte Carlo depletion capability was officially released from the Radiation Safety Information and Computational Center as MCNPX 2.6.0. With the merger of MCNPX and MCNP5, MCNP6 combined the capability of both simulation tools, as well as providing new advanced technology, in a single radiation transport code. The new MCNP6 depletion capability was first showcased at the International Congress for Advancements in Nuclear Power Plants (ICAPP) meeting in 2012. At that conference the new capabilities addressed included the combined distributive and shared memory parallel architecture for the burnup capability, improved memory management, physics enhancements, and new predictability as compared to the H.B Robinson Benchmark. At Los Alamos National Laboratory, a special purpose cluster named “tebow,” was constructed such to maximize available RAM per CPU, as well as leveraging swap space with solid state hard drives, to allow larger scale depletion calculations (allowing for significantly more burnable regions than previously examined). As the MCNP6 burnup capability was scaled to larger numbers of burnable regions, a noticeable slowdown was realized.This paper details two specific computational performance strategies for improving calculation speedup: (1) retrieving cross sections during transport; and (2) tallying mechanisms specific to burnup in MCNP. To combat this slowdown new performance upgrades were developed and integrated into MCNP6 1.2.

42 ENGINEERING↗

Proton Therapy At Siteman Cancer Center: The State Of The Art

Barnes-Jewish Hospital is on the verge of offering proton radiation therapy to its patients. Those treatments will be delivered from the first Monarch 250, a state-of-the-art cyclotron produced by Still River Systems, Inc., Littleton, MA. The accelerator is the world's first superconducting synchrocyclotron, with a field-strength of 10 tesla, providing the smallest accelerator for high-energy protons currently available. On May 14, 2010 it was announced that the first production unit had successfully extracted 250 MeV protons. That unit is scheduled for delivery to the Siteman Cancer Center, an NCI-designated Comprehensive Cancer Center at Washington University School of Medicine. At a weight of 20 tons and with a diameter of less than 2 meters the compact cyclotron will be mounted on a gantry, another first for proton therapy systems. The single-energy system includes 3 contoured scatterers and 14 different range modulators to provide 24 distinct beam delivery configurations. This allows proton fields up to 25 cm in diameter, with a maximum range from 5.5 to 32 cm and spread-out-Bragg-peak extent up to 20 cm. Monte Carlo simulations have been run using MCNPX to simulate the clinical beam properties. Those calculations have been used to commission a commercial treatment planning system prior to final clinical measurements. MCNPX was also used to calculate the neutron background generated by protons in the scattering system and patient. Additional details of the facility and current status will be presented.

43 PARTICLE ACCELERATORS↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of the Neutron Irradiation Facilities of the PSI Calibration Laboratory

The neutron radiation fields of the Calibration Laboratory at Paul Scherrer Institute (PSI) are traceable to the national standards of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. A Berthold LB6411 neutron dose rate meter for neutron radiation is used as a secondary standard. Recently, a thorough characterization of the neutron irradiation fields of the {sup 241}Am-Be and {sup 252}Cf sources by means of reference measurements and a detailed MCNPX simulation of the irradiation facility has been initiated. In this work, the characteristics of the neutron radiation fields are summarized and presented together with model equations and an uncertainty analysis. MCNPX results are shown for the {sup 241}Am-Be source. A comparison of measured and simulated data shows an excellent agreement. From the simulation, valuable information about the neutron fields like the contribution of scattered neutrons in the fields and the energy spectra could be obtained.

07 ISOTOPE AND RADIATION SOURCES↗

High and low energy gamma beam dump designs for the gamma beam delivery system at ELI-NP

The Extreme Light Infrastructure - Nuclear Physics (ELI-NP) is under construction in Magurele, Bucharest, Romania. The facility will use two 10 PW lasers and a high intensity, narrow bandwidth gamma beam for stand-alone and combined laser-gamma experiments. The accurate estimation of particle doses and their restriction within the limits for both personel and general public is very important in the design phase of any nuclear facility. In the present work, Monte Carlo simulations are performed using FLUKA and MCNPX to design 19.4 and 4 MeV gamma beam dumps along with shielding of experimental areas. Dose rate contour plots from both FLUKA and MCNPX along with numerical values of doses in experimental area E8 of the facility are performed. The calculated doses are within the permissible limits. Furthermore, a reasonable agreement between both codes enhances our confidence in using one or both of them for future calculations in beam dump designs, radiation shielding, radioactive inventory, and other calculations releated to radiation protection. Residual dose rates and residual activity calculations are also performed for high-energy beam dump and their effect is negligible in comparison to contributions from prompt radiation.

43 PARTICLE ACCELERATORS↗

Conceptual moderator studies for the Spallation Neutron Source short-pulse second target station

Candidate moderator configurations for a short-pulse second target station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) have been identified using a global optimizer framework built around the MCNPX particle transport code. Neutron brightness metrics were selected as the figure-of-merit. We assumed that STS would use one out of six proton pulses produced by an SNS accelerator upgraded to operate at 1.3 GeV proton energy, 2.8 MW power and 60 Hz repetition rate. The simulations indicate that the peak brightness can be increased by a factor of 5 and 2.5 on a per proton pulse basis compared to the SNS first target station for both coupled and decoupled para-hydrogen moderators, respectively. Additional increases by factors of 3 and 2 were demonstrated for coupled and decoupled moderators, respectively, by reducing the area of neutron emission from 100 × 100 mm{sup 2} to 20 × 20 mm{sup 2}. This increase in brightness has the potential to translate to an increase of beam intensity at the instruments’ sample positions even though the total neutron emission of the smaller moderator is less than that of the larger. This is especially true for instruments with small samples (beam dimensions). The increased fluxes in the STS moderators come at accelerated poison and de-coupler burnout and higher radiation-induced material damage rates per unit power, which overall translate into lower moderator lifetimes. A first effort was undertaken to group decoupled moderators into a cluster collectively positioning them at the peak neutron production zone in the target and having a three-port neutron emission scheme that complements that of a cylindrical coupled moderator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic Scintillator for Real-Time Neutron Dosimetry

We have developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with 137 Cs and 252 Cf, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV–0 MeV range using MCNPX-PoliMi. The measured unfolded 252 Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling study of a proposed field calibration source using K-40 and high-Z targets for sodium iodide detectors

Calibration sources based on the primordial isotope potassium-40 ( 40 K) have reduced controls on the source’s activity due to its terrestrial ubiquity and very low specific activity. Potassium–40’s beta emissions and 1,460.8 keV gamma ray can be used to induce K-shell fluorescence x rays in high-Z metals between 60 and 80 keV. A gamma ray calibration source that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument is thus proposed. The calibration source was designed in collaboration with the Sandia National Laboratory using the Monte Carlo N-Particle eXtended (MCNPX) transport code. Two methods of x-ray production were explored. First, a thin high-Z layer (HZL) was interposed between the detector and the potassium chloride-urethane source matrix. Second, bismuth metal powder was homogeneously mixed with a urethane binding agent to form a potassium chloride-bismuth matrix (KBM). The bismuth-based source was selected as the development model because it is inexpensive, nontoxic, and outperforms the high-Z layer method in simulation. As a result, based on the MCNPX studies, sealing a mixture of bismuth powder and potassium chloride into a thin plastic case could provide a light, inexpensive field calibration source.

40K↗