Optical characterization of a-As{sub 2}S{sub 3} thin films prepared by magnetron sputtering

It is well known that thermally evaporated a-As{sub 2}S{sub 3} thin films are prone to oxidation when exposed to ambient environment. These As{sub 2}O{sub 3} crystals can have a devastating effect on propagating light by introducing a major source of scattering loss in submicron optically integrated circuits. Magnetron sputtering a-As{sub 2}S{sub 3} not only produces films that have optical properties closer to their equilibrium state like their bulk glass counter parts, the as-deposited films also show no detectable signs of As{sub 2}O{sub 3} crystals in them when they are exposed to the ambient environment. These attributes are unique to a magnetron sputtered a-As{sub 2}S{sub 3} film and are probably caused by the ''photoannealing'' effect from the visible light emitted by the argon plasma during the sputtering process. The optical properties of a magnetron sputtered a-As{sub 2}S{sub 3} film and its propagation loss on a Ti diffused LiNbO{sub 3} waveguide are reported here. The thin film results agree closely with published data on As{sub 2}S{sub 3} bulk glass, and the optical properties of the as-deposited film are found to be closer to its bulk glass values than films made by thermal evaporation and pulsed laser deposition. The TM propagation loss at {lambda}=1.5 {mu}m of the as-deposited a-As{sub 2}S{sub 3} waveguide on Ti:LiNbO{sub 3} was 0.20{+-}0.05 dB/cm.

36 MATERIALS SCIENCE↗

Time-resolved investigation of dual high power impulse magnetron sputtering with closed magnetic field during deposition of Ti-Cu thin films

Time-resolved comparative study of dual magnetron sputtering (dual-MS) and dual high power impulse magnetron sputtering (dual-HiPIMS) systems arranged with closed magnetic field is presented. The dual-MS system was operated with a repetition frequency 4.65 kHz (duty cycle {approx_equal}50%). The frequency during dual-HiPIMS is lower as well as its duty cycle (f=100 Hz, duty 1%). Different metallic targets (Ti, Cu) and different cathode voltages were applied to get required stoichiometry of Ti-Cu thin films. The plasma parameters of the interspace between magnetrons in the substrate position were investigated by time-resolved optical emission spectroscopy, Langmuir probe technique, and measurement of ion fluxes to the substrate. It is shown that plasma density as well as ion flux is higher about two orders of magnitude in dual-HiPIMS system. This fact is partially caused by low diffusion of ionized sputtered particles (Ti{sup +},Cu{sup +}) which creates a preionized medium.

36 MATERIALS SCIENCE↗

Ion mass spectrometry investigations of the discharge during reactive high power pulsed and direct current magnetron sputtering of carbon in Ar and Ar/N{sub 2}

Ion mass spectrometry was used to investigate discharges formed during high power impulse magnetron sputtering (HiPIMS) and direct current magnetron sputtering (DCMS) of a graphite target in Ar and Ar/N{sub 2} ambient. Ion energy distribution functions (IEDFs) were recorded in time-averaged and time-resolved mode for Ar{sup +}, C{sup +}, N{sub 2}{sup +}, N{sup +}, and C{sub x}N{sub y}{sup +} ions. An increase of N{sub 2} in the sputter gas (keeping the deposition pressure, pulse width, pulse frequency, and pulse energy constant) results for the HiPIMS discharge in a significant increase in C{sup +}, N{sup +}, and CN{sup +} ion energies. Ar{sup +}, N{sub 2}{sup +}, and C{sub 2}N{sup +} ion energies, in turn, did not considerably vary with the changes in working gas composition. The HiPIMS process showed higher ion energies and fluxes, particularly for C{sup +} ions, compared to DCMS. The time evolution of the plasma species was analyzed for HiPIMS and revealed the sequential arrival of working gas ions, ions ejected from the target, and later during the pulse-on time molecular ions, in particular CN{sup +} and C{sub 2}N{sup +}. The formation of fullerene-like structured CN{sub x} thin films for both modes of magnetron sputtering is explained by ion mass-spectrometry results and demonstrated by transmission electron microscopy as well as diffraction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study on the effect of target on plasma parameters of magnetron sputtering discharge plasma

In this study, the effect of magnetron target on different plasma parameters of Argon/Hydrogen (Ar - H{sub 2}) direct current (DC) magnetron discharge is examined. Here, Copper (Cu) and Chromium (Cr) are used as magnetron targets. The value of plasma parameters such as electron temperature (kT{sub e}), electron density (N{sub e}), ion density (N{sub i}), degree of ionization of Ar, and degree of dissociation of H{sub 2} for both the target are studied as a function of input power and hydrogen content in the discharge. The plasma parameters are determined by using Langmuir probe and Optical emission spectroscopy. On the basis of the different reactions in the gas phase, the variation of plasma parameters and sputtering rate are explained. The obtained results show that electron and ion density decline with gradual addition of Hydrogen in the discharge and increase with rising input power. It brings significant changes on the degree of ionization of Ar and dissociation of H{sub 2}. The enhanced value of electron density (N{sub e}), ion density (N{sub i}), degree of Ionization of Ar, and degree of dissociation of H{sub 2} for Cr compared to Cu target is explained on the basis of it's higher Ion Induced Secondary Electron Emission Coefficient (ISEE) value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision vector control of a superconducting RF cavity driven by an injection locked magnetron

The technique presented in this paper enables the regulation of both radio frequency amplitude and phase in narrow band devices such as a Superconducting RF (SRF) cavity driven by constant power output devices i.e. magnetrons [1]. The ability to use low cost high efficiency magnetrons for accelerator RF power systems, with tight vector regulation, presents a substantial cost savings in both construction and operating costs - compared to current RF power system technology. An operating CW system at 2.45 GHz has been experimentally developed. Vector control of an injection locked magnetron has been extensively tested and characterized with a SRF cavity as the load. Amplitude dynamic range of 30 dB, amplitude stability of 0.3% r.m.s, and phase stability of 0.26 degrees r.m.s. has been demonstrated.

43 PARTICLE ACCELERATORS↗

Effect of magnetic field strength on deposition rate and energy flux in a dc magnetron sputtering system

Variations in the magnetic field strongly affect the plasma parameters in a magnetron sputtering system. This in turn affects the throughput as well as the energy flux to the substrate. The variation in the magnetic field in this study, for a dc magnetron process, is achieved by shifting the magnet assembly slightly away from the target. Measurements of the plasma parameters show that while the electron density at the substrate increases with decrease in magnetic field, the electron temperature decreases. The cooling of the electron temperature is consistent with results reported elsewhere. The deposition rate per input magnetron power is found to increase slightly with the decrease in magnetic field for the process conditions considered in this study. Results suggest that the energy flux to the substrate tends to show a general decrease with the shift in the magnet assembly.

36 MATERIALS SCIENCE↗

Simulation and Experimental Studies of a 2.45GHz Magnetron Source for an SRF Cavity with Field Amplitude and Phase Controls

Phase lock to an SRF cavity by using injection signal through output waveguide of a magnetron has been demonstrated [1, 3]. Amplitude control using magnetic field trimming and anode voltage modulation has been studied using MATLAB/Simulink simulations [2]. Based on these, we are planning to use an FPGA based digital LLRF system, which allows applying various types of control algorithms in order to achieve the required accelerating field stability. Since the 1497 MHz magnetron is still in the design stage, the proof of principle measurements of a commercial 2450 MHz magnetron are carried out to characterize the anode I-V curve, output power (the tube electronic efficiency), frequency dependence on the anode current (frequency pushing) and the Rieke diagram (frequency pulling by the reactive load). Based on early Simulink simulation, experimental data and extension of the Adler equation governing injection phase stability by Chen’s model, the specification of the new LLRF control chassis for both 2450 and 1497MHz systems are presented in this paper.

Wang, Haipeng↗

INJECTION LOCKED 1497 MHZ MAGNETRON

A novel injection-locked 1497 MHz 13 kW AM magnetron design is presented. An anode designed to minimize eddy currents due to the modulated magnetic field is presented. Thermal calculations of two design options are also presented. An extra degree of freedom in the anode construction is made possible by the fact that the magnetron is injection locked; as a result some additional design details that can be utilized in the cooling network for the magnetron anode are presented.

Wang, Haipeng↗

PROGRESS ON MAGNETRON R&DS FOR INDUSTRIAL PARTICLE ACCELERATORS

The magnetron as an efficient RF source for a compact industrial SRF accelerator has been developed. The per-formance of injection phase lock on two independent magnetron transmitters operated at 915MHz, in CW mode with maximum power of 75kW each has been demon-strated to satisfy this application. This industrial type magnetron has AC transformer and the SCR rectifier on the DC anode power supply. Output power spectrum with phase locking can achieve noise reduction of -21.2 dBc at the 1st 60 Hz, -28.0 dBc at 1st 180 Hz with only -22.6 dBc injection power. Further control studies for 2×75 kW, 915 MHz power combing by WR975 magic-tee at Jefferson Lab (JLab) and for 4×1.2 kW, 2.45 GHz power combing by WR340 magic-tee at General Atomics (GA).

Rimmer, R.↗

A 100 kW 1.3 GHz Magnetron System with Amplitude and Phase Control

Calabazas Creek Research, Inc., Fermilab, and Communications & Power Industries, LLC, developed a 100 kW peak, 10 kW average, 1.3 GHz, magnetron-based, RF system for driving accelerators. Efficiency varied between 81% and 87%. Phase locking uses a novel approach that provides fast amplitude and phase control when coupled into a superconducting accelerator cavity [1]. The system was successfully tested at Fermilab and produced 100 kW in 1.5 ms pulses at a repetition rate of 2 pps. A locking bandwidth of 0.9 MHz was achieved with a drive signal of 269 W injected through a 4 port circulator. The phase locking signal was 25 dB below the magnetron output power. The spectrum of the phase locked magnetron was suitable for driving accelerator cavities. Phase modulation was demonstrated to 50 kHz (the limit of the available driver source). The average power was limited by available conditioning time. Scaling indicates 42 kW of average power should be achievable. Estimated cost is less than $1/Watt of delivered RF power, exclusive of power supplies or modulators. System design and performance measurements will be presented.

43 PARTICLE ACCELERATORS↗

Magnetron R&D Progress for High Efficiency CW RF Sources of Industrial Accelerators

After the demonstration of using high efficiency magnetron power to combine and aim to drive a radio frequency accelerator at 2450MHz in CW mode [1], we have used trim coils adding to a water-cooled magnetron and three amplitude modulation methods in an open-loop control to further suppress the 120Hz side-band noise to -46.7dBc level. We have also successfully demonstrated the phase-locking to an industrial grade cooking magnetron transmitter at 915MHz with a 75kW CW power delivered to a water load by using a -26.6dBc injection signal. The sideband noise at 360Hz from the 3-Phase SCRs DC power supply can be reduced to -16.2dBc level. Their power combing scheme and higher power application to industrial accelerators are foreseeing.

Wang, H.↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source [Slides]

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of io n source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

Substrate heating rates for planar and cylindrical-post magnetron sputtering sources

Results are presented for the substrate heating energy/atom required in the planar magnetron sputtering of Al, Cr, Ni, Cu, Mo, In, Ta, W, and Pt in Ar, as well as Al and Cr in O2. Data are also obtained for cylindrical magnetron sputtering of Nb, Ag, Ta, W, and Pb-Sn in Ar, and Mo sputtered in Ne, Ar, Kr, and Xe. Planar and cylindrical magnetron heating rates were comparable. Special experiments were conducted to examine the contributions to substrate heating of plasma species and ion neutralization and reflection at the cathode; the results obtained indicate that charged plasma species do not significantly contribute to the heating, but that neutralized and reflected ions play a significant role in the planar as well as cylindrical cases despite the differences in cathode geometry.

Thornton, J. A.↗

Experimental radiation cooled magnetrons for space

The heat disposal problem that occurs in the microwave generator of the Solar Power Satellite when it converts dc power from solar photovoltaic arrays into microwave power for transmission to earth is examined. A theoretical study is made of the radiation cooling of a magnetron directional amplifier, and some experimental data obtained from the QKH 2244 magnetron are presented. This instrument is an unpackaged microwave oven magnetron to which an anodized aluminum radiator has been attached and whose magnetic field is supplied by special samarium cobalt magnets.

Brown, W. C.↗

Very low pressure high power impulse triggered magnetron sputtering

A method and apparatus are described for very low pressure high powered magnetron sputtering of a coating onto a substrate. By the method of this invention, both substrate and coating target material are placed into an evacuable chamber, and the chamber pumped to vacuum. Thereafter a series of high impulse voltage pulses are applied to the target. Nearly simultaneously with each pulse, in one embodiment, a small cathodic arc source of the same material as the target is pulsed, triggering a plasma plume proximate to the surface of the target to thereby initiate the magnetron sputtering process. In another embodiment the plasma plume is generated using a pulsed laser aimed to strike an ablation target material positioned near the magnetron target surface.

47 OTHER INSTRUMENTATION↗

Method and apparatus for improved high power impulse magnetron sputtering

A high power impulse magnetron sputtering apparatus and method using a vacuum chamber with a magnetron target and a substrate positioned in the vacuum chamber. A field coil being positioned between the magnetron target and substrate, and a pulsed power supply and/or a coil bias power supply connected to the field coil. The pulsed power supply connected to the field coil, and the pulsed power supply outputting power pulse widths of greater that 100 .mu.s.

42 ENGINEERING↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

Improved Magnetron Stability and Reduced Noise in Efficient Transmitters for Superconducting Accelerators

State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.