An Optically Pumped Comagnetometer for High-sensitivity RF Detection without Magnetic Shielding
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. Earlier work described the design alternatives and the geometry selected for a copper prototype. We subsequently have iterated the design to lower the R/Q of the cavity and to increase the diameter of the beam pipe ferrite HOM dampers to reduce the wakefield heating. A niobium cavity and full cryomodule including LN2 shield, magnetic shield and insulating vacuum vessel have been fabricated and installed. A passive SRF 3rd harmonic cavity consisting of two tightly coupled cells has been designed and fabricated for NSLS-II. Initial cold tests of this cavity are very promising. These tests have verified that the cavity frequency and mode separation between the 0 and {pi}-modes can be set at manufacture. Further, the frequency separation can be maintained over wide tuning ranges necessary for operation. Future work includes HOM damper and motorized tuner development.
One solution to the problem of shielding crew from particulate radiation in space is to use active electromagnetic shielding. Practical types of shield include the magnetic shield, in which a strong magnetic field diverts charged particles from the crew region, and the magnetic/electrostatic plasma shield, in which an electrostatic field shields the crew from positively charged particles, while a magnetic field confines electrons from the space plasma to provide charge neutrality. Advances in technology include high-strength composite materials, high-temperature superconductors, numerical computational solutions to particle transport in electromagnetic fields, and a technology base for construction and operation of large superconducting magnets. These advances make electromagnetic shielding a practical alternative for near-term future missions.
The shielding of a charge sheet in a magnetized plasma is investigated by taking account of the diamagnetic drift start-up current in addition to the polarization current. For a charge sheet with an infinitesimal width, the shielding is the same as the conventional Debye shielding if the charge sheet is perpendicular to the magnetic field; the shielding length is {radical}(2) times larger than the conventional one if the charge sheet is parallel to the magnetic field. When the scale length of the charge sheet is comparable or smaller than the ion Larmor radius, the electric field is significantly enhanced within the charge sheet, while far away from the charge sheet, the electric field is shielded to the usual 1/{epsilon}{sub r} level (where {epsilon}{sub r} is the diamagnetic coefficient of the magnetized plasma).
A magnetic shielding material includes a material comprising manganese bismuth (MnBi) and tungsten (W), where a ratio of MnBi:W is in a range of 50:50 to about 70:30. A radiation shielding product includes a part including manganese bismuth (MnBi) and tungsten (W), and a plurality of layers having a defined thickness in a z-direction, wherein each layer extends along an x-y plane perpendicular to the z-direction. At least some of the plurality of layers form a functional gradient in the z-direction and/or along the x-y plane, and the functional gradient is defined by a first layer comprising a ratio of MnBi:W being less than 100:0 and an nth layer above the first layer comprising a ratio of MnBi:W greater than 0:100.
Magnetic radiation shielding with superconducting coils and Mars mission shielding design
Shielding effectiveness and system mass of different magnetic field configurations - Electric properties and magnetic behavior of superconducting coils of niobium-zirconium alloy
Superconducting magnets for active space radiation shielding
Resolving anion configurations in heteroanionic materials is crucial for understanding and controlling their properties. For anion-disordered oxyfluorides, conventional Bragg diffraction cannot fully resolve the anionic structure, necessitating alternative structure determination methods. We have investigated the anionic structure of anion-disordered cubic (ReO 3 -type) TiOF 2 using X-ray pair distribution function (PDF), 19 F MAS NMR analysis, density functional theory (DFT), cluster expansion modeling, and genetic-algorithm structure prediction. Our computational data predict short-range anion ordering in TiOF 2 , characterized by predominant cis-[O 2 F 4 ] titanium coordination, resulting in correlated anion disorder at longer ranges. To validate our predictions, we generated partially disordered supercells using genetic-algorithm structure prediction and computed simulated X-ray PDF data and 19 F MAS NMR spectra, which we compared directly to experimental data. To construct our simulated 19 F NMR spectra, we derived new transformation functions for mapping calculated magnetic shieldings to predicted magnetic chemical shifts in titanium (oxy)fluorides, obtained by fitting DFT-calculated magnetic shieldings to previously published experimental chemical shift data for TiF 4 . We find good agreement between our simulated and experimental data, which supports our computationally predicted structural model and demonstrates the effectiveness of complementary experimental and computational techniques in resolving anionic structure in anion-disordered oxyfluorides. From additional DFT calculations, we predict that increasing anion disorder makes lithium intercalation more favorable by, on average, up to 2 eV, highlighting the significant effect of variations in short-range order on the intercalation properties of anion-disordered materials.
The upcoming and disrupted beams in the interaction region (IR) of a linear collider are focused by doublets consisting of two small-aperture superconducting quadrupoles. These magnets need an effective compact magnetic shielding to minimize magnetic coupling between the two channels and sufficient temperature margin to withstand radiation-induced heat depositions in the coil. This paper presents conceptual designs of IR quadrupoles for linear colliders based on NbTi and Nb{sub 3}Sn Rutherford-type cables.
Under Indian Institutions and Fermilab collaboration, Raja Ramanna Centre for Advanced Technology and Fermi National Accelerator Laboratory are jointly developing 2K Vertical Test Stand (VTS) cryostats for testing SCRF cavities at 2K. The VTS cryostat has been designed for a large testing aperture of 86.36 cm for testing of 325 MHz Spoke resonators, 650 MHz and 1.3 GHz multi-cell SCRF cavities for Fermilab's Project-X. Units will be installed at Fermilab and RRCAT and used to test cavities for Project-X. A VTS cryostat comprises of liquid helium (LHe) vessel with internal magnetic shield, top insert plate equipped with cavity support stand and radiation shield, liquid nitrogen (LN{sub 2}) shield and vacuum vessel with external magnetic shield. The engineering design and analysis of VTS cryostat has been carried out using ASME B&PV Code and Finite Element Analysis. Design of internal and external magnetic shields was performed to limit the magnetic field inside LHe vessel at the cavity surface <1 {micro}T. Thermal analysis for LN{sub 2} shield has been performed to check the effectiveness of LN{sub 2} cooling and for compliance with ASME piping code allowable stresses.
To reduce design risks for future magnetically shielded Hall thrusters, a test was performed on the HERMeS to obtain data for optimizing the effect of magnetic shielding. As a part of this test, laser-induced fluorescence velocimetry was used to characterize the variations in the ion acceleration with different magnetic configurations. Four magnetic configurations representing varying amounts of magnetic shielding between the high-energy discharge plasma and the discharge channel walls were tested. The ion velocity data points to the possibility that different plasma-wall interaction physics applies to a magnetically shielded thruster than a non-shielded thruster. The transition point is very prominent and can potentially be used to test whether a thruster is fully magnetically shielded.
To reduce design risks for future magnetically shielded Hall thrusters, a test was performed on the HERMeS to obtain data for optimizing the effect of magnetic shielding. As a part of this test, laser-induced fluorescence velocimetry was used to characterize the variations in the ion acceleration with different magnetic configurations. Four magnetic configurations representing varying amounts of magnetic shielding between the high-energy discharge plasma and the discharge channel walls were tested. The ion velocity data points to the possibility that different plasma-wall interaction physics applies to a magnetically shielded thruster than a non-shielded thruster. The transition point is very prominent and can potentially be used to test whether a thruster is fully magnetically shielded.
Charged particle motion in magnetic radiation shielding fields
We report on results of a new investigation into the Q0 degradation phenomenon observed in original CEBAF cavities when assembled into cryomodules. As a result, the RF dissipation losses increased by roughly a factor of two. The origin of the degradation, first observed in 1994, has remained unresolved up to current period, despite much effort. Recently, a new investigation has been launched, taking advantage of the latest cryomodule to undergo refurbishment. Systematic measurements are conducted with respect to the magnetic shielding effects of the double-layer shields and the magnetic properties of various components within the inner shield. This resulted in the new discovery of strongly magnetized strut springs as a major source of remnant magnetic flux near a cavity inside of all magnetic shielding. New springs with superior magnetic properties have been found, evaluated and implemented into the current cryomodule. Cryogenic RF testing of this module is expected to complete by end of 2013. In this contribution, we will review the data accumulated so far. Options for complete Q0 preservation of assembled cavities and possible Q0 remediation for those 330 cavities already installed in CEBAF will be presented.
We report on results of a new investigation into the Q0 degradation phenomenon observed in original CEBAF cavities when assembled into cryomodules. As a result, the RF dissipation losses increased by roughly a factor of two. The origin of the degradation, first observed in 1994, has remained unresolved up to current period, despite much effort. Recently, a new investigation has been launched, taking advantage of the latest cryomodule to undergo refurbishment. Systematic measurements are conducted with respect to the magnetic shielding effects of the double-layer shields and the magnetic properties of various components within the inner shield. This resulted in the new discovery of strongly magnetized strut springs as a major source of remnant magnetic flux near a cavity inside of all magnetic shielding. New springs with superior magnetic properties have been found, evaluated and implemented into the current cryomodule. Cryogenic RF testing of this module is expected to complete by end of 2013. In this contribution, we will review the data accumulated so far. Options for complete Q0 preservation of assembled cavities and possible Q0 remediation for those 330 cavities already installed in CEBAF will be presented.
The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.
An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven layers of high permeability materials in combination with highly conductive shields. Proper magnetic equilibration is crucial to obtain such low magnetic fields with small gradients in any MSR. Here, we report on a scheme to magnetically equilibrate MSRs with a 10 times reduced duration of the magnetic equilibration sequence and a significantly lower magnetic field with improved homogeneity. For the search of the neutron's electric dipole moment, our finding corresponds to a 40% improvement of the statistical reach of the measurement. However, this versatile procedure can improve the performance of any MSR for any application.