Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design Study of a Superconducting Quadrupole Magnet System Sustainable Under Dark Current Heating in ILC Main Linac

The International Linear Collider (ILC) main linac comprises a series of 12 m-long cryomodules. The cryomodule contains eight 9-cell superconducting (SC) RF (SRF) cavities and an SC quadrupole magnet combined with dipole correctors to focus and steer electron and positron beams. The magnets are installed between the SRF cavity string and at the longitudinal center of a common cryomodule/cryostat. These magnets are conductively cooled by pure aluminum channels thermally connected to a 2 K two-phase helium pipe for cooling the SRF cavities. A recent study shows that field-emitted electrons, so-called “dark current” initiated in the SRF cavities, are transmitted through the SRF cavity string and reach the SC magnet. The energy is inevitably absorbed in the SC coil due to the magnetic field, resulting in risks of a quench caused by the coil heating. We are investigating alternate magnet designs by using Nb $_{3}$ Sn or $\text{MgB}_{2}$ SC and by adding the dark current absorber surrounding the beam-pipe to realize sustainable magnet operation under the dark current heating. We report the design study of the magnet system and interfaces to the cryomodule accommodating it with the SRF cavities.

43 PARTICLE ACCELERATORS↗

A novel scheme for error field correction in permanent magnet stellarators

Stellarators offer a promising path towards fusion reactors, but their design and construction are complicated by stringent tolerance requirements on highly complex 3D coils. A potential way to simplify the engineering requirements for stellarators is to use simple planar toroidal field coils along with permanent magnet arrays to generate shaping fields. In order to ensure sufficient field accuracy while minimizing engineering complexity and system cost, new techniques are required to correct the field produced by the permanent magnet arrays to within requirements set by plasma physics. This work describes a novel correction method developed for this purpose. This analysis is applied to the design of a quasi-axisymmetric stellarator that employs a combination of permanent magnets and planar toroidal field coils to generate its magnetic field. Analysis techniques and initial results using the method for error correction on a proposed permanent magnet stellarator are shown, and it is demonstrated that the method successfully meets the design requirements of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast switching magnet for heavy ion beam separation

This paper presents the design for a switching magnet capable of deflecting 6.5 MeV/u heavy-ion beams with mass-to-charge ratio of 7 by 10 degrees. This magnet can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The magnet has a laminated, iron dominated, H-shaped core. Directly-cooled copper pancake coils energize the magnet. We present the magnet design considerations, including the results of extensive computer modeling. Finally, we also present the conceptual engineering design and the studies of magnet yoke fabrication.

47 OTHER INSTRUMENTATION↗

Improved prescription for winding an electromagnet

We describe an improvement on the magnetic scalar potential approach to design an electromagnet, which incorporates the need to wind the coil as a helix. Any magnetic field that can be described by a magnetic scalar potential is produced with high fidelity within a Target region; all fields are confined within a larger Return. The helical winding only affects the field in the Return.

47 OTHER INSTRUMENTATION↗

TCR Central Shutdown Rod Fine Motion Control

Transformational Challenge Reactor (TCR) is a Helium cooled 3 MWt test reactor that leverages advances in materials and manufacturing, computing, and AI in its design. Classical design of a shutdown rod uses either gravity, pneumatic, or springs to quickly release the Central Shutdown Rod (CSR) containing neutron absorber into the reactor core stopping nuclear reaction. Generally, the motor/actuator resides outside the reactor, but the motion is transmitted through a penetration into the pressure vessel. There are also designs where the control rod drive incorporates magnetic latches with coil residing outside the pressure boundary for precise position control of the rod. We are proposing a magnetic coupling to position the shutdown rod without any penetration into the pressure vessel for the entire drive length of TCR shutdown rod. Electromagnets are currently used in non-power nuclear reactors for shutdown rods, but these electromagnets are resident inside the reactor pressure vessel. This paper will describe the use of an electromagnet outside the pressure vessel to position and release the shutdown rod. A prototype was developed at ORNL to demonstrate the concept, and a design optimization of the ferritic core and material was conducted to maximize the lift force of the electromagnet. An elevated temperature testing was also performed to ensure that the system will perform under the temperature conditions inside an operating reactor.

Fountain, Eliott J.↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

Final design of outer poloidal field coils for COMPASS Upgrade

The paper aims to provide an overview of the final design of the outer poloidal field coils system for COMPASS Upgrade. Due to a relatively unique combination of design features of the new device (placement in high toroidal magnetic field, copper coils sub-cooled to liquid nitrogen temperature, hot vacuum vessel operation), the poloidal field coils design faced several interesting engineering challenges. Most notably high electromagnetic stress in the coil conductor, compatibility of the insulation to thermal and mechanical stress and design of coil supports with given spatial constraints while able to accommodate coil movements and withstand considerable mechanical stress. In conclusion, the paper describes solution to these challenges together with underlying analyses and mechanical tests.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analyses of the NSTX-U PF1A Poloidal Field Coil Support

New poloidal field (PF) coils and supports have been designed for the National Spherical Torus Experiment Upgrade (NSTX-U) Recovery project. The PF1A coil structural requirements demand a large preload to pre-compress the coil insulation. Coil support design accounts for all operational conditions and loads of NSTX-U including bakeout, seismic events, and electromagnetic loads. Background magnetic fields produce coil Lorentz forces that react on the structural supports. These Lorentz forces include interactions from the coil current and all plasma events: normal operations, disruptions, and vertical displacement events. This paper will detail the design and design loads and highlight some of the analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adult head-sized coil-based low-field MRI

An ultra-low field pre-pulse Magnetic Resonance Imaging (PMRI) system for a head includes RF coils defining a bore for head access, a pre-pulse coil outside the RF coils, and a coil assembly including a main magnetic field coil and gradient coils outside the pre-pulse coil. The PMRI system includes a first cylindrical shield concentric with the RF coils and made from conductive materials. The first cylindrical shield partially encloses the RF coils and inside the pre-pulse coil for shielding the RF coils from environmental electromagnetic disturbances.

Schiff, Steven J.↗

Conceptual Design of High Field Central Solenoid for Fusion Nuclear Science Facility

Fusion Nuclear Science Facility (FNSF) is a critical fusion nuclear step in the US beyond ITER before proceeding to a larger and electricity producing fusion power plant. Although FNSF is a steady state machine to be operated at high duty cycle, a high field and high current density central solenoid magnet is needed for plasma startups. Due to space constraints in the FNSF in-board radial build, the magnetic field and coil current density required exceed conventional low temperature superconductor (LTS) performance limits and the design can only be achieved by high temperature superconductors (HTS). The design for the central solenoid, also called the ohmic heating (OH) magnet for FNSF shall meet the 100 Weber double flux swing requirement for plasma startups. Finally, the stresses at such a high field and high current density coil may require a bucked and wedged TF-OH design to accommodate space for coil winding support structures in in-board system radial build for high field FNSF operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Engineering Design of D1/D3 Dipole Magnets for the Electron-Ion Collider (EIC)

Here, the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 10 34 cm −2 s −1 . An electron storage ring (ESR) will be installed in the existing Relativistic Heavy Ion Collider (RHIC) tunnel and will store polarized electron beams from 5 to 18 GeV. The ESR will have 750 dipole magnets with varying field requirements, including 576 super-bend triplets consisting of two magnets D1/D3 and D2. This paper presents on the engineering design of the D1/D3 dipole magnets within the arcs, with special focus on the coil design that allows the magnet to be configured for variable ampere-turns per energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stochastic and a posteriori optimization to mitigate coil manufacturing errors in stellarator design

Abstract It was recently shown in Wechsung et al (2022 Proc. Natl Acad. Sci. USA 119 e2202084119) that there exist electromagnetic coils that generate magnetic fields, which are excellent approximations to quasi-symmetric fields and have very good particle confinement properties. Using a Gaussian process-based model for coil perturbations, we investigate the impact of manufacturing errors on the performance of these coils. We show that even fairly small errors result in noticeable performance degradation. While stochastic optimization yields minor improvements, it is not possible to mitigate these errors significantly. As an alternative to stochastic optimization, we then formulate a new optimization problem for computing optimal adjustments of the coil positions and currents without changing the shapes of the coil. These a-posteriori adjustments are able to reduce the impact of coil errors by an order of magnitude, providing a new perspective for dealing with manufacturing tolerances in stellarator design.

Physics↗

Field quality of the 4.5 m-long MQXFA pre-series magnets for the HL-LHC Upgrade as observed during magnet assembly

We report that the U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) is developing MQXFA magnets, a series of 4.5 m long 150 mm aperture high-field Nb 3 Sn quadrupole magnets for the HL-LHC upgrade at CERN. Five pre-series magnets, MQXFA03 through MQXFA07, have been developed. During the magnet assembly stage, we perform magnetic measurements on the coil-pack sub-assembly and magnets after loading to track the field quality for two purposes. First, it serves as a quality assurance tool to check if the magnetic field quality is on track to meet the acceptance criteria. Magnetic measurements are used to understand if magnetic shims are needed to compensate low-order field errors and to meet the field quality targets. Second, the measurements during the assembly stage can also help understand the field quality, especially the geometric field errors, for Nb 3 Sn accelerator magnets. Here we summarize the measurement results of the pre-series MQXFA magnets, including the magnetic axis and twist angle. The results will provide useful feedback for the series production of Nb 3 Sn magnets and on the optimization of field quality of accelerator magnets based on the wind-and-react Nb 3 Sn technology.

43 PARTICLE ACCELERATORS↗

Conductor Properties and Coil Technology for a Bi2212 Dipole Insert for 20 Tesla Hybrid Accelerator Magnets

A dipole insert based on a 2-layer cos-theta coil with stress management and Bi2212 superconducting strand and cable is being developed at Fermilab as part of the US-MDP effort. The ultimate goal of this task is to develop coil technology and an approach to manage azimuthal and radial strains of high temperature superconductor inserts when integrated within Nb3Sn outserts as a hybrid magnet system. This note reviews conductor properties and possible coil technologies.

43 PARTICLE ACCELERATORS↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

Fabrication and test of a 6-tesla-class high-temperature superconducting dipole magnet at 4.2 K

Superconducting magnets enable energy-frontier accelerators by generating strong magnetic fields to steer and focus the particles. Although high-temperature superconductors such as REBa 2 Cu 3 O x (, RE = rare earth) hold a strong potential for generating a higher magnetic field than Nb-Ti and Nb 3 Sn , the associated magnet and conductor technology for accelerator applications is still in its infancy. The U.S. Magnet Development Program is developing magnet technology in collaboration with industry. Here we report an experiment of making a dipole magnet called C3 using commercial high-temperature superconducting wires. The magnet, following a canted cos θ design, generated a dipole field of 5.99 T at 4.2 K in its clear aperture of 65 mm at 6.795 kA when a resistive voltage of 105 μ V appeared across one of the coils in the magnet. The stored energy was 53 kJ at the peak field. The magnet showed no degradation in the current-carrying capability at 4.2 K after the thermal cycle. We report on the detailed design, fabrication, and performance of the C3 magnet that can be of interest to potential users of this emerging technology. We also discuss issues and research needs to inform future magnet development. The experiment represented another step to addressing if the high-temperature superconducting accelerator magnet technology can increase the discovery capability of future particle accelerators.

Abraimov, Dmytro [National High Magnetic Field Lab↗

Progress in the Development of the Nb 3 Sn MQXFB Quadrupole for the HiLumi Upgrade of the LHC

The high-luminosity upgrade of the Large Hadron Collider (HL-LHC) requires new high field and large-aperture quadrupole magnets for the low-beta inner triplets (MQXF). With a nominal operating gradient of 132.2 T/m in a 150 mm aperture and a conductor peak field of 11.3 T, the new quadrupole magnets are based on Nb 3 Sn superconducting technology. After a series of short models constructed in close collaboration by LARP (LHC Accelerator Research Program) and CERN, the development program is entering in the series production phase with CERN on one side and the US Accelerator Upgrade Project (US-AUP) on the other side assembling and testing full-length magnets. This paper describes the status of the development activities at CERN, in particular on the cold powering test of the first MQFXB prototype and on the construction of the second full scale prototype. Critical operations such as reaction heat treatment, coil impregnation and magnet assembly are discussed. Finally, the plan towards the series production is described.

43 PARTICLE ACCELERATORS↗

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗