Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lynx”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Searching the SOHO online catalogs

The SOHO on-line catalogs will contain information about the observations from several made or planned campaigns, that must be available to scientists who wish to use SOHO data. The World Wide Web (WWW) was chosen as the interface to the SOHO on-line catalogs, because it is easy to use, well suited to a geographically distributed user community, and freely available. Through the use of a forms-capable WWW client such as Mosaic or Lynx, a scientist will be able to browse through the catalogs of observations in a very simple, self explanatory way. Data files can then be selected from the returned lists for either immediate transferring or sending on tape by mail, with appropriate checks for whether data is in the public domain or not.

Thompson, William↗

Optical Measurement Center Status

Beginning in 2005, an optical measurement center (OMC) was created to measure the photometric signatures of debris pieces. Initially, the OMC was equipped with a 300 W xenon arc lamp, a SBIG 512 x 512 ST8X MEI CCD camera with standard Johnson filters, and a Lynx 6 robotic arm with five degrees of freedom. As research progressed, modifications were made to the equipment. A customized rotary table was built to overcome the robot s limitation of 180 degree wrist rotation and provide complete 360 degree rotation with little human interaction. This change allowed an initial phase angle (source-object-camera angle) of roughly 5 degrees to be adjusted to 7, 10, 15, 18, 20, 25, or 28 degrees. Additionally, the Johnson R and I CCD filters were replaced with the standard astronomical filters suite (Bessell R,I). In an effort to reduce object saturation, the two generic aperture stops were replaced with neutral density filters. Initially data were taken with aluminum debris pieces from the European Space Operations Centre ESOC2 ground test and more recently with samples from a thermal multi-layered insulation (MLI) commonly used on rocket bodies and satellites. The ESOC2 data provided light curve analysis for one type of material but many different shapes, including flat, bent, curled, folded, and torn. The MLI samples are roughly the same size and shape, but have different surfaces that give rise to interesting photometric light curves. In addition, filter photometry was conducted on the MLI pieces, a process that also will be used on the ESOC2 samples. While obtaining light curve data an anomalous drop in intensity was observed when the table revolved through the second 180 degree rotation. Investigation revealed that the robot s wrist rotation is not reliable past 80 degrees, thus the object may be at slightly different angles at the 180 degree transition. To limit this effect, the initial rotation position begins with the object s minimal surface area facing the camera.

Rodriguez, H.↗

Sensors Locate Radio Interference

After receiving a NASA Small Business Innovation Research (SBIR) contract from Kennedy Space Center, Soneticom Inc., based in West Melbourne, Florida, created algorithms for time difference of arrival and radio interferometry, which it used in its Lynx Location System (LLS) to locate electromagnetic interference that can disrupt radio communications. Soneticom is collaborating with the Federal Aviation Administration (FAA) to install and test the LLS at its field test center in New Jersey in preparation for deploying the LLS at commercial airports. The software collects data from each sensor in order to compute the location of the interfering emitter.

Source record↗

Design and Optimization of Multi-Pixel Transition-Edge Sensors for X-Ray Astronomy Applications

Multi-pixel transition-edge sensors (TESs), commonly referred to as 'hydras', are a type of position sensitive micro-calorimeter that enables very large format arrays to be designed without commensurate increase in the number of readout channels and associated wiring. In the hydra design, a single TES is coupled to discrete absorbers via varied thermal links. The links act as low pass thermal filters that are tuned to give a different characteristic pulse shape for x-ray photons absorbed in each of the hydra sub pixels. In this contribution we report on the experimental results from hydras consisting of up to 20 pixels per TES. We discuss the design trade-offs between energy resolution, position discrimination and number of pixels and investigate future design optimizations specifically targeted at meeting the readout technology considered for Lynx.

Smith, Stephen J.↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

NASA Develops Technology Today to Enable Breakthrough Observations Tomorrow

The COR and PCOS Programs, along with the Exoplanet Exploration Program (ExEP), work with four Science and Technology Definition Teams (STDTs), each studying a large-mission concept for the 2030s and beyond to inform the next astrophysics Decadal Survey. Lynx operates at X-ray wavelengths. The Origins Space Telescope (OST) is a far-IR mission. The Large UV/optical/IR Surveyor (LUVOIR) has a joint focus on general astrophysics and exoplanet science. As indicated by its name, the priority science goal of the Habitable Exoplanet Observatory (HabEx) is exoplanet science using visual and IR wavelengths. In addition to these four, NASA is participating in the Laser Interferometer Space Antenna (LISA), a European Space Agency (ESA) gravitational-wave mission.

Pham, Thai↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Integration of Multilevel Superconducting Buried Wiring Layers with Transition-Edge Sensor Detectors for Large Scale Arrays

Lynx, one of the four mission concepts under consideration for the next Astrophysics DecadalReview, will include a microcalorimeter array consisting of more than 100,000 pixels in a compact arrangement with absorber pitch as small as 25 microns. In order to realize the desired array scale, fine-pitch multi-level superconducting wiring with high yield, compatible with rapid expansion of our hydra absorber designs, is essential. We have demonstrated a method of integrating transition edge sensor (TES) microcalorimeters with suitable multilevel buried wiring, fabricated at MIT Lincoln Laboratory using advanced tools dedicated to superconducting circuit fabrication. The TES Mo/Au bilayer is deposited on a high-quality oxide surface created by chemical-mechanical polishing, allowing tight specifications on the TES superconducting transition and link conductivity to be achieved even though the process order has been inverted. The TESs contact the top-level niobium wiring through vias etched through silicon dioxide down to the topmost wiring layer. The article discusses the overall fabrication process, as wellas the behavior of sensors with different via designs, proximity structures, and lateral sizes. An initial iteration of the integrated fabrication process indicates that microcalorimeters fabricated in this way should meet mission specifications using a Mo/Au bilayer with a reasonable critical temperature below 100 mK.

Detector↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Study Update

In preparation for the 2020 Decadal Survey in Astronomy and Astrophysics, NASA commissioned the study of four large mission concepts: the Large UV/Optical/Infrared Surveyor (LUVOIR), the Habitable Exoplanet Imager (HabEx), the far-infrared surveyor Origins Space Telescope (OST), and the X-ray surveyor Lynx. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. The LUVOIR Study Office, located at NASA's Goddard Space Flight Center (GSFC), is developing two mission concepts to achieve the science objectives. LUVOIR-A is a 15-meter segmented-aperture observatory that would be launched in an 8.4-m extended fairing on the Space Launch System (SLS) Block 2 configuration. LUVOIR-B is an 8-meter unobscured segmented aperture telescope that fits in a smaller, conventional 5-meter fairing, but still requires the lift capacity of the SLS Block 1B Cargo vehicle. Both concepts include a suite of serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical/near-infrared coronagraph capable of delivering 10 (sup minus10) contrast at inner working angles as small as 2 lambda divided by D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100-400 nanometer) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager. LUVOIR-A also has a fourth instrument, Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d'Etudes Spatiales (CNES). This paper provides an overview of the LUVIOR science objectives, design drivers, and mission concepts.

Decadal Study↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Study Update

In preparation for the 2020 Decadal Survey in Astronomy and Astrophysics, NASA commissioned the study of four large mission concepts: the Large UV/Optical/Infrared Surveyor (LUVOIR), the Habitable Exoplanet Imager (HabEx), the far-infrared surveyor Origins Space Telescope (OST), and the X-ray surveyor Lynx. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. The LUVOIR Study Office, located at NASA's Goddard Space Flight Center (GSFC), is developing two mission concepts to achieve the science objectives. LUVOIR-A is a 15-meter segmented-aperture observatory that would be launched in an 8.4-meter extended fairing on the Space Launch System (SLS) Block 2 configuration. LUVOIR-B is an 8-meter unobscured segmented aperture telescope that fits in a smaller, conventional 5-meter fairing, but still requires the lift capacity of the SLS Block 1B Cargo vehicle. Both concepts include a suite of serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical/near-infrared coronagraph capable of delivering 10 (sup minus 10) contrast at inner working angles as small as 2 lambda divided by D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100-400 nanometer) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager. LUVOIR-A also has a fourth instrument, Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d'Etudes Spatiales (CNES). This paper provides an overview of the LUVIOR science objectives, design drivers, and mission concepts.

Decadal Study↗

Magnetic Calorimeter Arrays with High Sensor Inductance and Dense Wiring

We describe prototype arrays of magnetically coupled microcalorimeters fabricated with an approach scalable to very large format arrays. The superconducting interconnections and sensor coils have sufficiently low inductance in the wiring and sufficiently high inductance in the coils in each pixel, to enable arrays containing greater than 4000 sensors and 100,000 X-ray absorbers to be used in future astrophysics missions such as Lynx. We have used projection lithography to create submicron patterns (e.g., 400-nanometer-lines and spaces) in our niobium sensor coils and wiring, integrated with gold-erbium sensor films and gold X-ray absorbers. Our prototype devices will explore the device physics of metallic magnetic calorimeters as feature sizes are reduced to nanoscale.

Magnetism↗

Astronomical X-Ray Optics Using Mono-Crystalline Silicon: High Resolution, Light Weight, and Low Cost

X-ray astronomy critically depends on X-ray optics. The capability of an X-ray telescope is largelydetermined by the point-spread function (PSF) and the photon-collection area of its mirrors, the same astelescopes in other wavelength bands. Since an X-ray telescope must be operated above the atmosphere inspace and that X-rays reflect only at grazing incidence, X-ray mirrors must be both lightweight and thin, bothof which add significant technical and engineering challenge to making an X-ray telescope. In this paper wereport our effort at NASA Goddard Space Flight Center (GSFC) of developing an approach to making an Xraymirror assembly that can be significantly better than the mirror assembly currently flying on the ChandraX-ray Observatory in each of the three aspects: PSF, effective area per unit mass, and production cost per uniteffective area. Our approach is based on the precision polishing of mono-crystalline silicon to fabricate thinand lightweight X-ray mirrors of the highest figure quality and micro-roughness, therefore, having thepotential of achieving diffraction-limited X-ray optics. When successfully developed, this approach will makeimplementable in the 2020s and 2030s many X-ray astronomical missions that are currently on the drawingboard, including sounding rocket flights such as OGRE, Explorer class missions such as STAR-X andFORCE, Probe class missions such as AXIS, TAP, and HEX-P, as well as large missions such as Lynx.

Zhang, William W.↗

Calibration and Testing of Small High-Resolution Transition Edge Sensor Microcalorimeters With Optical Photons

Pulses of narrow line-width optical photons can be used to calibrate and test sub-2 eV full-width at half-maximum (FWHM) energy resolution transition-edge sensor (TES) microcalorimeters at low energies (<1 keV),where it is very challenging to obtain X-ray calibration lines comparable to (or narrower than) the detector resolution. This scheme depends on the ability to resolve the number of 3 eV photons in each pulse, which we have recently demonstrated up to photon numbers of about 300. AtLTD-18 we showed preliminary results obtained with this technique on a 0.25 eV baseline resolution TES microcalorimeter designed for the ultra-high-resolution sub-array of the Lynx mission. The line-shape was well described by a simple Gaussian. However, the difficulty of delivering photons to the small 46 μm square absorbers resulted in a large thermal crosstalk signal, whose random nature is expected to rapidly degrade the observed energy resolution towards higher photon numbers/energies. We have since improved the coupling between the optical fiber and the TES absorber and report here our current results.

Felix T Jaeckel↗

Initial Findings in Full-Shell Active Optics

The realization of active full-shell x-ray optics will provide ground-breaking capability for future missions. Future X-ray missions, such as Lynx, require high angular-resolution, large effective area, and as wide a field of view(FOV) as possible. It is currently not possible to perform high-resolution imaging of both wide and narrow FOVs with a single X-ray telescope. In this paper, we discuss the use of actuators to switch the optical surface of full-shell x-ray optics between prescriptions optimized for narrow-field and wide-field viewing, as well as correct for low-spatial-frequency errors in the optics. Previously, a pathfinder was developed using finite-element modeling(FEM). Using a combination of the model’s influence functions, the capacity of active full-shell optics was shown to switch between prescriptions with 92% accuracy. Another benefit of the analytical pathfinder was its ability to correct low-spatial frequency errors, which comprise a large percentage of the MSFC full-shell x-ray optics root-mean-square (RMS) slope error. In order to verify the pathfinder, a surface-parallel actuator was bonded to a nickel-replicated coupon. After the actuator was bonded to the coupon, the slope of the surface was measured while the actuator was activated. The proof-of-concept demonstrator development, the influence function data, and the resulting implications on the analytical pathfinder are reported and discussed.

X-ray optics↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Achieving Large-Scale, High-Resolution, Full Shell Replicated X-Ray Optics: Budgeting for Sources of Spatial Resolution Errors

Technology for a large-area, high-angular resolution mirror module for a future Great Observatory x-ray mission is progressing along different paths. To date, none of these are fully developed. Work at the Marshall Space Flight Center (MSFC) seeks to leverage the benefits of full shell optics while exploring the limits of using shell replication technology for optics production. Here, we provide an updated accounting of spatial-resolution-constraining error terms to give context to recent improvements in MSFC replicated optics, as well as guidance and justification for current and future directions of research. Content includes strawman error allocations for an optical system that is parametrically Lynx-like, where the replicated-optics technology stands relative to these allocations, and methodology for mapping development plans to efficiently identify the limiting factors and approaches to overcoming these.

error budget↗