Safety Functions and Features, Events and Processes for the E-Area Performance Assessment

The DOE Technical Standard, “Disposal Authorization Statement and Tank Closure Documentation,” (DOE 2017) recommends the use of safety functions and features, events and processes (FEPs) to support development of conceptual models and identification of scenarios to be considered in a performance assessment (PA). The FEP process provides a means to describe how a PA considers and addresses the factors that could influence the performance of key barriers. Understanding the roles of barriers in terms of limiting migration helps to focus on how changes in the system could lead to a situation where those roles cannot be fulfilled and there is the potential for compromised performance. The FEPs screening and review process was used to identify FEPs that are relevant for the EArea Low-Level Waste Facility (LLWF) and specifically those FEPs that could have a detrimental impact on the effectiveness of a given safety function. For this PA, a default list of FEPs developed at the International Atomic Energy Agency (IAEA 2004) and an approach implemented for PAs at the Hanford and Idaho sites (Mehta et al. 2016, DOE-ID 2019) are used to identify processes and events that could influence the effectiveness of a given safety function for the E-Area LLWF (e.g., subsidence can impact the safety function of the cover system and lead to increased infiltration). The Hanford and Idaho PAs represent two of the most recent applications of this approach. The PA evaluates the potential impacts of changes in performance of different features of the system and demonstrates that the safety functions represent multiple and redundant barriers. Barrier analyses, assuming a safety function is not present, also test the robustness of the system in the event of the loss of one or more safety functions. Such evaluations also support a qualitative illustration of the concept of defense in depth. The safety concept for closure of the E-Area LLWF (generically referred to as “E-Area”) encompasses a variety of different features (i.e., administrative controls, natural site features, and engineered barriers) that reduce the potential impacts on human health and the environment from the residual waste that will remain after closure. These features can be represented as a collection of safety functions acting independently and as a system to provide for overall safety. In some applications, there have been attempts to assign numerical expectations to specific safety functions, but that is not the intent in this case. The concept of safety functions is used more qualitatively in two ways for this PA: 1. To illustrate the robustness of the E-Area design, operational practices and closure approach by documenting features that are and are not credited in different modeling cases. 2. To identify the roles of the different features and potential processes and events that could compromise the performance of safety features and need to be considered when developing the modeling approach. This report addresses both safety functions and FEPs for the E-Area PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comoparison of Slit Trench and Engineered Trench 3D Vadose Zone Conceptual Models

In the next revision of the E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA), radionuclide groundwater transport from slit (ST) and engineered trenches (ET) will be simulated using 3-dimensional PORFLOW models representing the vadose zone. In total, the conceptual framework will aim to model 29 total trenches with a degree of conservatism that provides a high level of confidence in meeting performance objectives. The implementation of generic conceptual models allows for a reasonable number of simulation scenarios, thereby reducing the chances of errors and enabling a better one-to-one comparison between the results, while still capturing the most important features of each trench. The current investigation seeks to understand if a generic trench model based on the general ET footprint can justifiably be used for representing both STs and ETs while maintaining a reasonable degree of conservatism. In this process, the groundwater transport of several key radionuclides was simulated for both ET and ST geometries and the flux-to-the-water-table profiles were compared. For all radionuclides simulated, the ET geometry is shown to be conservative (i.e., produces the highest peak flux to the water table).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Properties Data Package for the E-Area Soils, Cementitious Materials, and Waste Zones–Update

Hydraulic property estimates for the soils, cementitious materials, and waste zones associated with the E-Area low-level radioactive waste disposal units have been provided to support the Performance Assessments (PA) for the E-Area Low-Level Waste Facility (LLWF). Nominal or “best estimate” hydraulic property values for use in the deterministic modeling are provided along with representations of the hydraulic property value uncertainty for use in sensitivity and uncertainty modeling. The hydraulic properties provided for each of the E-Area materials include: porosity ( η ), dry bulk density ( ρ b ), particle density (ρ p ), saturated hydraulic conductivity ( K sat ), characteristic curves (suction head, saturation, and relative permeability), and effective diffusion coefficient ( D e ). A representation of the uncertainty associated with each property, except for the characteristic curves, is provided for each material, except for the E-Area waste zones. These nominal parameter values for each of the E-Area soils, cementitious materials, and waste zones, and, where indicated, parameter uncertainty representations, are based upon the following in order of priority: Site-specific field data, Site-specific laboratory data, Similarity to material with site-specific field or laboratory data, and Literature data. Additionally, a methodology to represent long-term concrete degradation is provided. Finally, because much of the nominal hydraulic property values and uncertainty representations for the E-Area soils, cementitious materials, and waste zones are based on similarity to other materials or literature data, a methodology to prioritize additional work to better define these values and representations is outlined. Prioritization should be based on the importance of the material and/or property to the results of deterministic, sensitivity, and uncertainty modeling. This prioritization should be established through a process of sensitivity modeling. This report supersedes the previous hydraulic properties data package. Revision 1 contains clarifications, updates and corrections to text, figures and tables in a number of places in the report along with some minor editing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GoldSim E-Area Low-Level Waste Lacility Vadose Zone Model Benchmarking

This report documents the development and benchmarking of the E-Area Low-Level Waste Facility (ELLWF) GoldSim Engineered and Slit Trench (ET and ST) vadose zone models. Subsequent activities (beyond the scope of this effort) will couple the GoldSim-based vadose zone models to the GoldSim aquifer model, with the intent of performing stochastic analyses that couple all pertinent fate and transport processes from the ground surface up to the 100-m Point of Assessment (POA). The benchmarking presented within this report focuses on the Slit Trench 06 (ST06) bydrostratigraphic location that resides within the center set of slit trenches. These GoldSim-based vadose zone models are generic models capable of being benchmarked to any of the other trench locations within E-Area.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Installation of Lysimeters Near Engineered Trench 3

Three new lysimeter stations were installed on the north rim of Engineered Trench 3 (Figure ES-1)at the E-Area Low Level Waste Facility (ELLWF). These stations were designated as ET3-VL-3, ET3-VL-4, and ET3-VL-5. The stations were installed in a line with the two existing stations (ET3-VL-1 and ET3-VL-2) and spaced approximately 100 ft apart. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placement was based on borehole lithology and was comparable to the existing lysimeter stations. The deepest lysimeter at each of the three new lysimeter stations was designated as the action-level lysimeter.Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in December 2020 with each lysimeter producing 1000 ml of water for tritium analysis. All lysimeters were below the administrative limit for ET3 (43.7 pCi/ml) with all but ET3-VL-5 (222) at background levels. ET3-VL-5 (222) had a tritium concentration of 27.5 pCi/ml.With the addition of the new lysimeters at ET3, the vadose zone monitoring system is now comprised of 309 active lysimeters at 102 lysimeter stations. There are 93 action-level lysimeters at 102 stations

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updated Estimate of Tritium Permeation from TPBAR Disposal Containers in ILV (U)

A tritium source term analysis was performed for TPBAR disposal in the E-Area Intermediate Level Vaults for the E-Area Low-Level Waste Facility Performance Assessment (PA). This analysis is based on an earlier source term analysis which treated the bulk oft he tritium residual as tightly bound by the TPBAR getter material, with only a small fraction existing as tritiated moisture in the lithium aluminate ceramic pellets. Together with atmospheric moisture trapped in the free volume, the tritiated water vapor is assumed to corrode steel surfaces inside the disposal container, covering them with a magnetite film while generating hydrogen. The carbon steel walls of the disposal container are permeable to hydrogen, providing a path way for tritium to escape containment. The rate of hydrogen generation is assumed to be limited by the rate of corrosion, which is assumed to be governed by parabolic reaction kinetics obtained from the literature. This relies on the further assumption that the water vapor consumed by the corrosion reaction is continually replaced by moisture from the lithium aluminate pellets until all of that moisture is gone. In addition to tritium permeation, the analysis also includes a slow leak through the disposal container walls at the maximum allowable leak rate, 1 x 1CH standard cm3/s. Results were obtained for four different combinations of internal and container wall temperatures, established in an earlier thermal analysis that considered two different vault loadings and two different TPBAR activity levels. Instantaneous release rates for these four cases are plotted in Figure ES-1 below

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Installation of Lysimeters and Monitoring Wells in Support of the Revised Approach to E-Area Performance Monitoring

Savannah River Site (SRS) has developed a revised approach to performance monitoring of the E Area Low Level Waste Facility (ELLWF) that adds a saturated zone component to the existing vadose zone monitoring program (Kubilius, 2019). The revised approach specifies modifications to the vadose zone monitoring program, the addition of new lysimeters at Engineered Trench 3 (ET3), and the installation of water table monitoring wells to complement the existing well network surrounding the ELLWF. This project summary report is intended to provide the final construction details and layout for the new vadose zone lysimeters at ET3 and the water table monitoring wells installed as part of the new saturated zone component of the revised performance monitoring program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Installation of Lysimeters Near Engineered Trench 3, Slit Trench 8, and Slit Trench 9

Nine new lysimeter stations were installed at the E-Area Low Level Waste Facility (ELLWF). Six lysimeter stations were installed near Engineered Trench 3 (ET3), one installed near Slit Trench 8 (ST8), and two installed near Slit Trench 9 (ST9) as shown in Figure ES-1. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placements were based on borehole lithology and were comparable to existing nearby lysimeter stations. The deepest lysimeter at each of the new lysimeter stations was designated as the action-level lysimeter. Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in April 2023. Analytical results from the sampling will be provided in the Spring 2023 Lysimeter Tritium Data technical memo and the 2023 Annual Summary Report. With the addition of the new lysimeters at ET3, ST8, and ST9, the vadose zone monitoring system is now comprised of 327 active lysimeters at 111 lysimeter stations. There are 102 action-level lysimeters at 111 stations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Appendix H

This section provides supporting material for the development of DU-specific final inventory limits for the GW pathways for every generic waste form and SWF parent radionuclide requiring an inventory limit. The final inventory limits are based on nominal PA transport simulations using PORFLOW as reported in Chapter 5. The nominal PA settings represent the compliance case where some modeling parameter settings are defined based on conservative (pessimistically leaning) arguments. In the overall computational approach employed in this PA, a multitiered radionuclide screening process is adopted as discussed in Chapter 2, Section 2.3.7. In the multitiered process, the initial list of 1,252 parent radionuclides is shortened substantially using conservative, but simple, transport models, along with a reasonably low cutoff criterion of 0.1% SOF value. Multidimensional PORFLOW flow and transport modeling is employed for every parent radionuclide that failed the GW screening. The generic waste form limits represent Tier-3 analyses, while Tier-4 analyses are employed for SWF limits, where warranted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 3

This chapter summarizes safety functions and features, events, and processes; conceptual models which apply to all DUs; property data packages; and modeling tools developed and implemented in this PA to analyze ELLWF performance. Conceptual models of GW flow and transport in the VZ, which are specific to type of DU, are presented in Chapter 4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 4

This chapter describes the GW flow and transport conceptual models in the VZ for both generic and special waste forms in STs, ETs, LAWV, ILV, and NRCDAs. The development and implementation of the GoldSim® system model for trenches is also introduced. The Trench System Model is used for sensitivity analysis and uncertainty quantification as reported in Chapter 6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 5

This chapter presents selected GW flow and radionuclide contaminant transport results from PORFLOW for the VZ and aquifer zone for each type of DU (STs, ETs, LAWV, ILV, and NRCDAs). Results for the nominal PA compliance case and various sensitivity cases are given. Results for the VZ include water saturation spatial profiles and radionuclide flux-to-the-water- table time profiles. Aquifer zone results include maximum concentration spatial contours; radionuclide concentration time profiles at the 100-meter POA; and peak concentrations at the 100-meter POA and time of occurrence for each modeled radionuclide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 6

This chapter provides a description of the methods used for the sensitivity and uncertainty quantification analyses and identifies the parameters and assumptions found to be most important in the determination of compliance with PA performance objectives, development of WAC, establishment of individual DU inventory limits, and other regulatory decisions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 8

This chapter, together with Appendix H, provides the necessary CWTS inventory limits and trigger values for every parent radionuclide not screened out in Sections 2.3.6, 2.3.7, and 2.3.8. Also provided are details associated with how generic and special waste forms are handled on a DU-specific basis, and a discussion of the conversion of preliminary inventory limits (via transport runs summarized in Chapter 5) into final inventory limits for use in the CWTS limits system. Using the final inventory limits, a projected 2065 CWTS inventory is generated for use in the PA closure analysis outlined in Chapter 9.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Chapter 9

This chapter summarizes the results of PA compliance against all relevant PA POs and measures. The final inventory limits presented in Chapters 7 and 8, as well as the methodology employed, provide assurance that POs will be met throughout the compliance periods. Deterministic and stochastic closure analyses also demonstrate a minimal likelihood of exceeding POs. Potential peaks post compliance are also addressed where future work is proposed to improve the understanding in actual uncertainties.