Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LiF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Laser-Induced Fluorescence (LIF) from plant foliage

The fluorescence spectra and fluorescence induction kinetics of green plants excited at 337 nm by a laser were studied. They correlate with plant type, as well as with changes in the physiology of the plant as the result of stress. The plant types studied include herbaceous dicots, monocots, hardwoods, conifers, and algae. These plant types could be identified on the basis of differences in either the number of fluorescent bands or the relative intensity of the bands. Differences in fluorescent spectra which could be related to vigor status are observed in conifers located in an area of high atmospheric deposition. Changes in the fluorescence spectra and induction kinetics are also seen in plants grown under conditions of nutrient deficiency and drought stress.

Chappelle, E. W.↗

Laser-Induced Fluorescence (LIF) from plant foliage

The fluorescence spectra and fluorescence induction kinetics of green plants excited at 337 nm by a laser were studied. They correlate with plant type, as well as with changes in the physiology of the plant as the result of stress. The plant types studied include herbaceous dicots, monocots, hardwoods, conifers, and algae. These plant types could be identified on the basis of differences in either the number of fluorescent bands or the relative intensity of the bands. Differences in fluorescent spectra which could be related to vigor status are observed in conifers located in an area of high atmospheric deposition. Changes in the fluorescence spectra and induction kinetics are also seen in plants grown under conditions of nutrient deficiency and drought stress.

Chappelle, Emmett W.↗

Velocity measurements in a hydrogen arcjet using LIF

A new diagnostic developed to measure the axial velocity of atomic hydrogen in a 1-kW hydrogen-fueled arcjet thruster is reported. The technique is based on laser-induced fluorescence of the Balmer alpha transition (656 nm) in atomic hydrogen. A narrow-band CW ring dye laser scans the excitation spectrum permitting accurate determination of the absorption line shape and position. The velocity is derived from the Doppler-shifted line position. A spatially resolved velocity profile is presented with a peak velocity of 12.8 km/s at the arcjet centerline near the exit plane.

Liebeskind, John G.↗

High-resolution OH LIF velocity measurement technique for high-speed reacting flows

A nonintrusive optical technique was developed for the quantitative study of velocity fields in steady, high-speed, reacting flows. A narrow-linewidth laser source was tuned through an isolated OH absorption line to measure the Doppler-shifted linecenter frequency relative to an iodine reference line. A counterpropagating beam approach was used to eliminate collisional impact shift effects. Pointwise measurements of velocity were made in a unique reacting underexpanded jet facility as an extensive calibration of the technique over a wide range of flow conditions. The extension of the technique to planar measurements is also discussed.

Klavuhn, K. G.↗

Measurement Of Thermal Conductivity Of Molten LiF

Report discusses experimental study of thermal conductivity of molten lithium fluoride. Study motivated by consideration of material for use as energy-storage medium in solar power systems.

Jaworske, Donald A.↗

LIF measurements of scalar mixing in turbulent shear layers

The structure of shear layer flows at high Reynolds numbers remains a very interesting problem. Straight mixing layers have been studied and yielded information on the probability density function (pdf) of a passive scalar across the layer. Konrad and Koochesfahani & Dimotakis measured the pdf of the mixture fraction for mixing layers of moderate Reynolds numbers, each about 25,000 (Re based on velocity difference and visual thickness). Their measurements showed a 'non-marching' pdf (central hump which is invariant from edge to edge across the layer), a result which is linked to the visualizations of the spanwise Kelvin-Helmholtz (K-H) instability mode, which is the primary instability for plane shear layer flows. A secondary instability mode, the Taylor-Gortler (T-G) instability, which is associated with streamwise vortical structures, has also been observed in shear layers. Image reconstruction by Jimenez et al. and volume renderings by Karasso & Mungal at low Re numbers have demonstrated that the K-H and the T-G instability modes occur simultaneously in a non-mutually destructive way, evidence that supports the quasi two-dimensional aspect of these flows and the non-marching character of the pdf at low Reynolds numbers. At higher Re numbers though, the interaction of these two instability modes is still unclear and may affect the mixing process. In this study, we perform measurements of the concentration pdf of plane mixing layers for different operating conditions. At a speed ratio of r = U(sub 1)/U(sub 2) = 4:1, we examine three Reynolds number cases: Re = 14,000, Re = 31,000, and Re = 62,000. Some other Re number cases' results, not presented in detail, are invoked to explain the behavior of the pdf of the concentration field. A case of r = 2.6:1 at Re = 20,000 is also considered. The planar laser-induced fluorescence technique is used to yield quantitative measurements. The different Re are obtained by changing the velocity magnitudes of the two streams. The question of resolution of these measurements is addressed. In order to investigate the effects of the initial conditions on the development and the structure of the mixing layer, the boundary layer on the high-speed side of the splitter plate is tripped. The average concentration and the average mixed fluid concentration are also calculated to further understand the changes in the shear layer for the different cases examined.

Karasso, Paris S.↗

Proton calibration of low energy neutron detectors containing (6)LiF

The purpose of the present calibrations is to measure the proton response of the detectors with accelerated beams having energies within the region of maximum intensities in the trapped proton spectrum encountered in near-Earth orbit. This response is compared with the responses of the spaceflight detectors when related to proton exposures. All of the spaceflight neutron measurements have been accompanied by TLD absorbed doses measurements in close proximity within the spacecraft. For purposes of comparison, the spaceflight TLD doses are assumed to be proton doses.

Benton, E. V.↗

A LiF silicon sandwich counter to measure water content of planetary surfaces

The neutron counter proposed here has a long history and was commercially available in a somewhat different form. This counter would be suitable for a rover or lander since it requires a rather long measuring time for each placement. It consists of two silicon wafer charged-particle counters with a layer of Li-6F deposited on the inner surface of one. The neutron detecting reaction is Li-6(n,H-3)He-4 in which the alpha particle and the triton are emitted from the Li-6 deposit back to back. If one of the detectors sees the alpha particle, the other will see the triton. This allows one to use a coincidence technique that virtually eliminates all background. The signals from each detector can be added together so that the total energy of the reaction, Q=4.6 MeV and the kinetic energy of the neutron, can be recorded.

Drake, D. M.↗

Laser Induced Fluorescence (LIF) as a Remote Sensing Tool: A Review

Vegetational changes are primary indicators of the present and future ecological status of the globe. These are changes which not only impact upon the primary productivity, but the total of the biogeochemical processes occurring on the planet. The impacts of global climatic and other environmental changes on vegetation must be monitored by some means in order to develop models which will allow us to predict long term effects. Large scale monitoring is now possible only with remote sensing systems, primarily passive reflectance, obtained by the use of satellite and aircraft platforms. However, passive reflectance techniques at this time are limited in their ability to detect subtle changes in the concentration and oxidation states of the many compounds involved in the light reactions of photosynthesis. Knowledge of these changes we consider to be fundamental in the remote assessment of both the rate and efficiency of photosynthesis and also the early detection of stress damage. The above factors pointed to the desirability of a sensing technique with the sensitivity and specificity necessary for detecting and quantifying those biological entities involved in photosynthesis. Another optical technique for vegetation monitoring is fluorescence. Previously, the lack of adequate excitation light sources and detector technologies have limited the use of fluorescence on intact plant leaves in the field. It is only recently with the advent of lasers with short pulse duration and advanced detector technologies that fluorescence measurements in the remote mode have become possible in the presence of ambient light.

Chappelle, E. W.↗

Simultaneous Laser Raman-rayleigh-lif Measurements and Numerical Modeling Results of a Lifted Turbulent H2/N2 Jet Flame in a Vitiated Coflow

An experiment and numerical investigation is presented of a lifted turbulent H2/N2 jet flame in a coflow of hot, vitiated gases. The vitiated coflow burner emulates the coupling of turbulent mixing and chemical kinetics exemplary of the reacting flow in the recirculation region of advanced combustors. It also simplifies numerical investigation of this coupled problem by removing the complexity of recirculating flow. Scalar measurements are reported for a lifted turbulent jet flame of H2/N2 (Re = 23,600, H/d = 10) in a coflow of hot combustion products from a lean H2/Air flame ((empty set) = 0.25, T = 1,045 K). The combination of Rayleigh scattering, Raman scattering, and laser-induced fluorescence is used to obtain simultaneous measurements of temperature and concentrations of the major species, OH, and NO. The data attest to the success of the experimental design in providing a uniform vitiated coflow throughout the entire test region. Two combustion models (PDF: joint scalar Probability Density Function and EDC: Eddy Dissipation Concept) are used in conjunction with various turbulence models to predict the lift-off height (H(sub PDF)/d = 7,H(sub EDC)/d = 8.5). Kalghatgi's classic phenomenological theory, which is based on scaling arguments, yields a reasonably accurate prediction (H(sub K)/d = 11.4) of the lift-off height for the present flame. The vitiated coflow admits the possibility of auto-ignition of mixed fluid, and the success of the present parabolic implementation of the PDF model in predicting a stable lifted flame is attributable to such ignition. The measurements indicate a thickened turbulent reaction zone at the flame base. Experimental results and numerical investigations support the plausibility of turbulent premixed flame propagation by small scale (on the order of the flame thickness) recirculation and mixing of hot products into reactants and subsequent rapid ignition of the mixture.

Cabra, R.↗

Simultaneous Raman-Rayleigh-LIF Measurements and Numerical Modeling Results of a Lifted H2/N2 Turbulent Jet Flame in a Vitiated Coflow

An experimental and numerical investigation is presented of a H2/N2 turbulent jet flame burner that has a novel vitiated coflow. The vitiated coflow emulates the recirculation region of most combustors, such as gas turbines or furnaces. Additionally, since the vitiated gases are coflowing, the burner allows for exploration of recirculation chemistry without the corresponding fluid mechanics of recirculation. Thus the vitiated coflow burner design facilitates the development of chemical kinetic combustion models without the added complexity of recirculation fluid mechanics. Scalar measurements are reported for a turbulent jet flame of H2/N2 in a coflow of combustion products from a lean ((empty set) = 0.25) H2/Air flame. The combination of laser-induced fluorescence, Rayleigh scattering, and Raman scattering is used to obtain simultaneous measurements of the temperature, major species, as well as OH and NO. Laminar flame calculation with equal diffusivity do agree when the premixing and preheating that occurs prior to flame stabilization is accounted for in the boundary conditions. Also presented is an exploratory pdf model that predicts the flame's axial profiles fairly well, but does not accurately predict the lift-off height.

Cabra, R.↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive for Low-Temperature Operation of Li-(CF)n Cells

Some progress has been reported in continuing research on the use of anion-receptor compounds as electrolyte additives to increase the sustainable rates of discharge and, hence, the discharge capacities, of lithium-poly(carbon monofluoride) [Li-(CF)n, where n >1] primary electrochemical power cells. Some results of this research at a prior stage were summarized in Increasing Discharge Capacities of Li(CF)n Cells (NPO-42346), NASA Tech Briefs, Vol. 32, No. 2 (February 2008), page 37. A major difference between the present and previously reported results is that now there is some additional focus on improving performance at temperatures from ambient down to as low as 40 C. To recapitulate from the cited prior article: During the discharge of a Li-(CF)n cell, one of the electrochemical reactions causes LiF to precipitate at the cathode. LiF is almost completely insoluble in most non-aqueous solvents, including those used in the electrolyte solutions of Li- (CF)n cells. LiF is electrochemically inactive and can block the desired transport of electrons at the cathode, and, hence, the precipitation of LiF can form an ever-thickening film on the cathode that limits the rate of discharge. An anion-receptor electrolyte additive helps to increase the discharge capacity in two ways: It renders LiF somewhat soluble in the non-aqueous electrolyte solution, thereby delaying precipitation until a high concentration of LiF in solution has been reached. When precipitation occurs, it promotes the formation of large LiF grains that do not conformally coat the cathode. The net effect is to reduce the blockage caused by precipitation of LiF, thereby maintaining a greater degree of access of electrolyte to the cathode and greater electronic conductivity.

West, William↗

Enhanced Far Ultra-Violet Optical Properties of Physical Vapor Deposited Aluminum Mirrors Through Fluorination

Astronomical instrumentation for measurements in the Far Ultra-Violet (FUV, 90-200 nm) typically use aluminum (Al) thin films due to their high reflectance over this wavelength range. However, the native aluminum oxide layer that forms on Al upon exposure to the atmosphere is strongly absorbing in this wavelength range, requiring that the films be protected with a dielectric that inhibits oxidation. Typically, magnesium fluoride (MgF 2 ) or lithium fluoride (LiF) coatings are used as protective layers, but each has shortcomings. For example, MgF 2 has an absorption cutoff at 115 nm reducing performance in a critical part of the FUV spectrum of observational interest. A viable option to access these lower wavelengths could be the use of the LiF overcoat as it has a lower absorption cutoff at 102.5 nm, but it is hygroscopic and thus susceptible to degradation in humid conditions. An approach to reduce the hygroscopic nature of LiF would be to implement a passivation process during the deposition of both Al+LiF coatings. Our team at GSFC has developed a new reactive Physical Vapor Deposition (rPVD) process that consists of a fluorination process with XeF 2 gas combined with our traditional PVD process. We have found that this new rPVD coating process offers a protected version of Al+LiF with a more environmentally stable and more transparent LiF layer, along with unprecedent reflectivity. The process starts with a bare optically smooth substrate that is coated with Al in an ultra-high vacuum (UHV) chamber by the conventional PVD process. Then, the bare Al mirror is immediately exposed to a reactive XeF 2 gas before and after the application of the flash PVD evaporated LiF layer. We have also been investigating the use of this rPVD coating process for potential efficiency enhancements of Si-based gratings. Since it is known that the XeF 2 vapor is a strong Si etchant, we are investigating if the native SiO 2 layer on Si is sufficient to protect the groove profile of e-beam-ruled Si gratings from degradation. We will report on the characterization of various Al+LiF witness mirror coatings (both on borosilicate and Si) performed under various deposition conditions using the XeF 2 passivation process. These tests include XPS to determine film stoichiometry and AFM/SEM to measure surface roughness and any etching on the Si substrate. We will also report on FUV reflectance and spectroscopic ellipsometry to characterize optical constants of these passivated films in the UV/Visible/NIR spectral ranges.

Engineering (General)↗

Enhanced Far Ultra-Violet Optical Properties of Physical Vapor Deposited Aluminum Mirrors Through Fluorination

Astronomical instrumentation for measurements in the Far Ultra-Violet (FUV, 90-200 nm) typically use aluminum (Al) thin films due to their high reflectance over this wavelength range. However, the native aluminum oxide layer that forms on Al upon exposure to the atmosphere is strongly absorbing in this wavelength range, requiring that the films be protected with a dielectric that inhibits oxidation. Typically, magnesium fluoride (MgF 2 ) or lithium fluoride (LiF) coatings are used as protective layers, but each has shortcomings. For example, MgF 2 has an absorption cutoff at 115 nm reducing performance in a critical part of the FUV spectrum of observational interest. A viable option to access these lower wavelengths could be the use of the LiF overcoat as it has a lower absorption cutoff at 102.5 nm, but it is hygroscopic and thus susceptible to degradation in humid conditions. An approach to reduce the hygroscopic nature of LiF would be to implement a passivation process during the deposition of both Al+LiF coatings. Our team at GSFC has developed a new reactive Physical Vapor Deposition (rPVD) process that consists of a fluorination process with XeF 2 gas combined with our traditional PVD process. We have found that this new rPVD coating process offers a protected version of Al+LiF with a more environmentally stable and more transparent LiF layer, along with unprecedent reflectivity. The process starts with a bare optically smooth substrate that is coated with Al in an ultra-high vacuum (UHV) chamber by the conventional PVD process. Then, the bare Al mirror is immediately exposed to a reactive XeF 2 gas before and after the application of the flash PVD evaporated LiF layer. We have also been investigating the use of this rPVD coating process for potential efficiency enhancements of Si-based gratings. Since it is known that the XeF 2 vapor is a strong Si etchant, we are investigating if the native SiO 2 layer on Si is sufficient to protect the groove profile of e-beam-ruled Si gratings from degradation. We will report on the characterization of various Al+LiF witness mirror coatings (both on borosilicate and Si) performed under various deposition conditions using the XeF 2 passivation process. These tests include XPS to determine film stoichiometry and AFM/SEM to measure surface roughness and any etching on the Si substrate. We will also report on FUV reflectance and spectroscopic ellipsometry to characterize optical constants of these passivated films in the UV/Visible/NIR spectral ranges.

Engineering (General)↗

Enhanced Far Ultra-Violet Optical Properties of Physical Vapor Deposited Aluminum Mirrors Through Fluorination

Astronomical instrumentation for measurements in the Far Ultra-Violet (FUV, 90-200 nm) typically use aluminum (Al) thin films due to their high reflectance over this wavelength range. However, the native aluminum oxide layer that forms on Al upon exposure to the atmosphere is strongly absorbing in this wavelength range, requiring that the films be protected with a dielectric that inhibits oxidation. Typically, magnesium fluoride (MgF 2 ) or lithium fluoride (LiF) coatings are used as protective layers, but each has shortcomings. For example, MgF 2 has an absorption cutoff at 115 nm reducing performance in a critical part of the FUV spectrum of observational interest. A viable option to access these lower wavelengths could be the use of the LiF overcoat as it has a lower absorption cutoff at 102.5 nm, but it is hygroscopic and thus susceptible to degradation in humid conditions. An approach to reduce the hygroscopic nature of LiF would be to implement a passivation process during the deposition of both Al+LiF coatings. Our team at GSFC has developed a new reactive Physical Vapor Deposition (rPVD) process that consists of a fluorination process with XeF 2 gas combined with our traditional PVD process. We have found that this new rPVD coating process offers a protected version of Al+LiF with a more environmentally stable and more transparent LiF layer, along with unprecedent reflectivity. The process starts with a bare optically smooth substrate that is coated with Al in an ultra-high vacuum (UHV) chamber by the conventional PVD process. Then, the bare Al mirror is immediately exposed to a reactive XeF 2 gas before and after the application of the flash PVD evaporated LiF layer. We have also been investigating the use of this rPVD coating process for potential efficiency enhancements of Si-based gratings. Since it is known that the XeF 2 vapor is a strong Si etchant, we are investigating if the native SiO 2 layer on Si is sufficient to protect the groove profile of e-beam-ruled Si gratings from degradation. We will report on the characterization of various Al+LiF witness mirror coatings (both on borosilicate and Si) performed under various deposition conditions using the XeF 2 passivation process. These tests include XPS to determine film stoichiometry and AFM/SEM to measure surface roughness and any etching on the Si substrate. We will also report on FUV reflectance and spectroscopic ellipsometry to characterize optical constants of these passivated films in the UV/Visible/NIR spectral ranges.

Engineering (General)↗