Limb Correction of Individual Infrared Channels Used in RGB Composite Products

This study demonstrates that limb-cooling can be removed from infrared imagery using latitudinally and seasonally dependent limb correction coefficients, which account for an increasing optical path length as scan angle increases. Furthermore, limb-corrected RGB composites provide multiple advantages over uncorrected RGB composites, including increased confidence in the interpretation of RGB features, improved situation awareness for operational forecasters, seamless transition between overlaid RGB composites, easy comparison of RGB products from different sensors, and the availability of high quality proxy products for the GOES-R era, as demonstrated by the case examples presented in Section 3. This limb correction methodology can also be applied to additional infrared channels used to create other RGB products, including those created from other satellite sensors, such as Suomi NPP Visible Infrared Imaging Radiometer Suite (VIIRS).

RGB↗

The LEMUR 3 Limbed Climbing Robot

This paper introduces a new four-limbed robot, LEMUR 3, that has demonstrated climbing on cliff faces and smooth glass. Each limb on the robot consists of seven identical actuators in a serial chain. Each limb terminates in a single axis force sensor that allows various end effectors to be mounted and connected to the robot’s power and communication system. Microspine grippers were used for climbing the rocky surface and gecko adhesive grippers were used for the glass solar panels. All other hardware and much of the software was common for the two demonstrations. The robot’s mechanical, electrical, and software systems, various gripping devices, and field demonstrations are described. Limbed mobility is of interest to JPL and NASA because of its potential to access extreme terrain, including that on Mars and in microgravity environments.

Kennedy, Brett↗

Intensity-modulated radiation therapy to bilateral lower limb extremities concurrently: a planning case study

Non-melanomatous skin cancers represent 80% of all newly diagnosed cancers in Australia with basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) being the most common. A previously healthy 71-year-old woman presented with widespread and tender superficial skin cancers on the lower bilateral limbs. External beam radiation therapy through the use of intensity-modulated radiation therapy (IMRT) was employed as the treatment modality of choice as this technique provides conformal dose distribution to a three-dimensional treatment volume while reducing toxicity to surrounding tissues. The patient was prescribed a dose of 60 Gy to the planning target volume (PTV) with 1.0 cm bolus over the ventral surface of each limb. The beam arrangement consisted of six treatment fields that avoided entry and exit through the contralateral limb. The treatment plans met the International Commission on Radiation Units and Measurements (ICRU) guidelines and produced highly conformal dosimetric results. Skin toxicity was measured against the National Cancer Institute: Common Terminology Criteria for Adverse Events (NCI: CTCAE) version 3. A well-tolerated treatment was delivered with excellent results given the initial extent of the disease. This case study has demonstrated the feasibility and effectiveness of IMRT for skin cancers as an alternative to surgery and traditional superficial radiation therapy, utilising a complex PTV of the extremities for patients with similar presentations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Alternative Techniques for Treatment of Complex Below-the Knee Arterial Occlusions in Diabetic Patients With Critical Limb Ischemia

The purpose of this study was to describe alternative endovascular (EV) techniques and assess their feasibility and efficacy in minimizing failure rates in limb salvage for the treatment of complex below-the knee (BTK) occlusions that could not be crossed with a conventional antegrade access. Between December 2007 and November 2010, 1,035 patients (557 male) underwent EV treatment for critical limb ischemia in our institution. In 124 (12% [83 male], mean age 68.2 {+-} 0.5 years) patients, transfemoral antegrade revascularization attempt failed, and an alternative approach was used. Follow-up was performed at 1 and 6 months. Results were compared with 56 patients treated between November 2002 and November 2007, in whom conventional technique was unsuccessful and unconventional techniques were not adopted. Technical success was achieved in 119 (96%) patients. The limb-salvage rates were 96.8% and 83% at 1- and 6-month follow-up, respectively. Sixteen (12.9%) and 33 (26.6%) patients underwent reintervention at 1- and 6-month follow-up, respectively. Transcutaneous oxygen tension increased at 1 month (44.7 {+-} 1.1 vs. 15.7 {+-} 0.8 mmHg; p < 0.001) and remained stable at follow-up. Twenty (16.1%) patients required major amputation. Thirteen (10.4%) patients died during follow-up. In our previous experience, percutaneous transluminal angioplasty failure, amputation, and death rates were 10.9, 39.2, and 23.2%, respectively. Alternative techniques allowed a significant decrease of major amputation and death rates (p = 0.0001 and p = 0.02, respectively). The use of alternative techniques seems feasible in case of a failed antegrade BTK revascularization attempt and could minimize failure rates in the treatment of complex occlusions while providing satisfying clinical success rates at 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Incompetent Pelvic Veins for the Treatment of Recurrent Varicose Veins in Lower Limbs and Pelvic Congestion Syndrome

We present our experience with embolization of incompetent pelvic veins (IPV) in women with recurrence of varicose veins (VV) in lower limbs, as well as symptoms of pelvic congestion syndrome (PCS), after first surgery. In addition, we evaluated the effects of embolization in decreasing the symptoms of VV before surgery as well as its effects on PCS symptoms. We included 10 women who had consulted a vascular surgeon because of recurrent VV in lower limbs after surgery. All of these patients were included in the study because they also had symptoms of PCS, probably due to IPV. In patients who had confirmed IPV, we performed embolization before a second surgery. VV and PCS were assessed before and at 3 months after embolization (before the second surgery) using a venous clinical severity score (VCSS) and a visual analog pain scale (VAS), respectively. Patients were controlled between 3 and 6 months after embolization. Paired Student t test analysis was used for comparing data before and after embolization. Fifteen vein segments in 10 women were suitable for embolization. There was a significant (p < 0.001) decrease of VCSS after embolization, and recurrence of VV was not detected within a period of 6 months. There was also significant (p < 0.01) relief of chronic pelvic pain related to PCS evaluated using VAS at 3 months after embolization. Embolization decreases the risk of VV recurrence after surgery and also improves PCS symptoms in women with VV in lower limbs and IPV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra-arterial Autologous Bone Marrow Cell Transplantation in a Patient with Upper-extremity Critical Limb Ischemia

Induction of therapeutic angiogenesis by autologous bone marrow mononuclear cell transplantation has been identified as a potential new option in patients with advanced lower-limb ischemia. There is little evidence of the benefit of intra-arterial cell application in upper-limb critical ischemia. We describe a patient with upper-extremity critical limb ischemia with digital gangrene resulting from hypothenar hammer syndrome successfully treated by intra-arterial autologous bone marrow mononuclear cell transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data extending to average depths of 2.5 mm, 3.4 mm, and 10 mm for the 1-mm, 2-mm, and 5-mm dimension calculation matrices, respectively. These results emphasize the importance of selecting as small a treatment planning software calculation matrix dimension as is practically possible and of taking a conservative approach for skin treatment planning objectives. One suggested conservative approach is accomplished by defining the skin organ as the outermost 2-3 mm of the body such that the high dose tail of the skin organ dose-volume histogram curve represents dose on the deep side of the skin where the algorithm is more accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Genetic evidence that SOST inhibits WNT signaling in the limb

SOST is a negative regulator of bone formation, and mutations in human SOST are responsible for sclerosteosis. In addition to high bone mass, sclerosteosis patients occasionally display hand defects, suggesting that SOST may function embryonically. Here we report that overexpression of SOST leads to loss of posterior structures of the zeugopod and autopod by perturbing anterior–posterior and proximal–distal signaling centers in the developing limb. Mutant mice that overexpress SOST in combination with Grem1 and Lrp6 mutations display more severe limb defects than single mutants alone, while Sost -/- significantly rescues the Lrp6 -/- skeletal phenotype, signifying that SOST gain-of-function impairs limb patterning by inhibiting the WNT signaling through LRP5/6.

Biological and medical sciences↗

PHOTOMETRIC TRENDS IN THE VISIBLE SOLAR CONTINUUM AND THEIR SENSITIVITY TO THE CENTER-TO-LIMB PROFILE

Solar irradiance variations over solar rotational timescales are largely determined by the passage of magnetic structures across the visible solar disk. Variations on solar cycle timescales are thought to be similarly due to changes in surface magnetism with activity. Understanding the contribution of magnetic structures to total solar irradiance and solar spectral irradiance requires assessing their contributions as a function of disk position. Since only relative photometry is possible from the ground, the contrasts of image pixels are measured with respect to a center-to-limb intensity profile. Using nine years of full-disk red and blue continuum images from the Precision Solar Photometric Telescope at the Mauna Loa Solar Observatory, we examine the sensitivity of continuum contrast measurements to the center-to-limb profile definition. Profiles which differ only by the amount of magnetic activity allowed in the pixels used to determine them yield oppositely signed solar cycle length continuum contrast trends, either agreeing with previous results and showing negative correlation with solar cycle or disagreeing and showing positive correlation with solar cycle. Changes in the center-to-limb profile shape over the solar cycle are responsible for the contradictory contrast results, and we demonstrate that the lowest contrast structures, internetwork and network, are most sensitive to these. Thus the strengths of the full-disk, internetwork, and network photometric trends depend critically on the magnetic flux density used in the quiet-Sun definition. We conclude that the contributions of low contrast magnetic structures to variations in the solar continuum output, particularly to long-term variations, are difficult, if not impossible, to determine without the use of radiometric imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic Evidence of Alfvén Wave Damping in the Off-limb Solar Corona

We investigate the off-limb active-region and quiet-Sun corona using spectroscopic data. The active region is clearly visible in several spectral lines formed in the temperature range of 1.1–2.8 MK. We derive the electron number density using the line ratio method, and the nonthermal velocity in the off-limb region up to the distance of 140 Mm. We compare density scale heights derived from several spectral line pairs with expected scale heights per the hydrostatic equilibrium model. Using several isolated and unblended spectral line profiles, we estimate nonthermal velocities in the active region and quiet Sun. Nonthermal velocities obtained from warm lines in the active region first show an increase and then later either a decrease or remain almost constant with height in the far off-limb region, whereas nonthermal velocities obtained from hot lines show consistent decrease. However, in the quiet-Sun region, nonthermal velocities obtained from various spectral lines show either a gradual decrease or remain almost constant with height. Using these obtained parameters, we further calculate Alfvén wave energy flux in both active and quiet-Sun regions. We find a significant decrease in wave energy fluxes with height, and hence provide evidence of Alfvén wave damping. Furthermore, we derive damping lengths of Alfvén waves in the both regions and find them to be in the range of 25–170 Mm. Different damping lengths obtained at different temperatures may be explained as either possible temperature-dependent damping or by measurements obtained in different coronal structures formed at different temperatures along the line of sight. Temperature-dependent damping may suggest some role of thermal conduction in the damping of Alfvén waves in the lower corona.

79 ASTRONOMY AND ASTROPHYSICS↗

The Earth Observing System Microwave Limb Sounder (EOS MLS) on the Aura Satellite

The Earth Observing System Microwave Limb Sounder measures several atmospheric chemical species (OH, HO2, H2O, O3, HCl, ClO, HOCl, BrO, HNO3, N2O, CO, HCN, CH3CN, volcanic SO2), cloud ice, temperature, and geopotential height to improve our understanding of stratospheric ozone chemistry, the interaction of composition and climate, and pollution in the upper troposphere. All measurements are made simultaneously and continuously, during both day and night. The instrument uses heterodyne radiometers that observe thermal emission from the atmospheric limb in broad spectral regions centered near 118, 190, 240, and 640 GHz, and 2.5 THz. It was launched July 15, 2004 on the National Aeronautics and Space Administration's Aura satellite and started full-up science operations on August 13, 2004. An atmospheric limb scan and radiometric calibration for all bands are performed routinely every 25 s. Vertical profiles are retrieved every 165 km along the suborbital track, covering 82 S to 82 N latitudes on each orbit. Instrument performance to date has been excellent; data have been made publicly available; and initial science results have been obtained.

submillimeter wave↗

A Wheel-On-Limb Rover for Lunar Operations

The All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) is a new mobility platform developed for potential lunar operations. This six limbed rover is designed to traverse quickly over benign terrain by rolling, traverse rough and steep terrain by walking, as well as perform general manipulation of tools and payloads. This flexible robotic platform will provide a mobile base for pressurized lunar habitats allowing for long range surface exploration and crew transport. It will also enable in-situ construction of lunar assets providing astronauts with the ability to assemble, maintain, and service a wide range of cargo. This paper presents the design details and capabilities of this wheel-on-limb platform.

ATHLETE↗

Modification and Development of a Control Mechanism for the Scanning Microwave Limb Sounder

The scanning microwave limb sounder (SMLS) is the latest instrument to probe the Earth's atmosphere to come out of the Microwave Limb Sounder (MLS) team. Once deployed to the upper stratosphere, it will use microwave detection to measure geo-atmospheric variables such as temperature, pressure, and chemical composition. In addition to previous missions that used vertical limb scans to observe altitudinal variations, the SMLS will rotate laterally allowing it to establish two-dimensional variable dependencies with a single run. A program was originated by a previous intern that will automatically control the movement of the two rotational axes along with a switching mirror and chopper once the instrument is in flight. However, it lacked the code essential to control system's ability to function fully and reliably. By modifying and rewriting parts of the code I sought to have a finished ready-for-flight control system that would be easy to navigate. Three of the major alterations I made including instituting a gyroscope, implementing a restart button, and instigating the automatic creation of a file log with each run to record the position and orientation of the SMLS.

Scanning Microwave Limb Sounder (SMLS)↗

Below-the-ankle Angioplasty and Stenting for Limb Salvage: Anatomical Considerations and Long-term Outcomes

PurposeTo report the long-term angiographic and clinical results in a series of below-the-ankle (BTA) angioplasty procedures and to present some biomechanical issues related to the unique anatomical geometry of the ankle.MethodsWe performed a retrospective analysis of BTA angioplasty procedures. Clinical end points included technical success, patient mortality, salvage of the treated foot, and repeat target lesion revascularization. Imaging end points included primary patency, binary restenosis of the target lesion at the 50 % threshold, and stent integrity (stent fracture, deformation, or collapse). Univariate subgroup analysis was performed.ResultsIn total, 40 limbs in 37 patients (age 73.5 {+-} 8.2 years) with critical limb ischemia were included and 42 inframalleolar lesions (4.2 {+-} 1.4 cm) were analyzed. Technical success was achieved in 95.2 % (40 of 42). Provisional stent placement was performed in 45.2 % (19 of 42). Two patients died, and two major amputations occurred up to 3 years. At 1 year, overall primary vessel patency was 50.4 {+-} 9.1 %, lesion binary restenosis rate was 64.1 {+-} 8.3 %, and repeat intervention-free survival was 93.6 {+-} 4.3 % according to life table analysis of all treated lesions. Pairwise subgroup analysis showed that BTA self-expanding stents were associated with significantly higher restenosis and poorer primary patency compared to plain balloon angioplasty or sirolimus-eluting balloon-expandable stents. Significant deformation and/or fracture of balloon-expandable stents placed BTA were identified in five of 11. Dynamic imaging showed that the dorsalis pedis artery is kinked during foot dorsiflexion, whereas the distal posterior tibial artery is kinked during plantar flexion of the foot.ConclusionBTA angioplasty for critical limb ischemia treatment is safe and feasible with satisfactory long-term results. BTA stent placement must be reserved for bailout indications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recanalisation of Chronically Occluded Remote Superficial Femoral Artery Endarterectomy Through Angioplasty for Limb Salvage

We report a novel application of balloon angioplasty to recanalise a chronically occluded remote endarterectomy superficial femoral artery. This patient previously had two occluded surgical bypass grafts in an attempt to revascularise the limb and presented with critical limb ischaemia and necrotic foot ulcerations. Following the angioplasty, the patient showed significant improvement in rest pain and healing of the ulcerations. This technique may be useful for limb salvage in patients where surgical options have been exhausted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Drug-Coated Balloon Angioplasty of Infrapopliteal Lesions in Patients with Critical Limb Ischaemia: 1-Year Results of the APOLLO Trial

Purpose: This study intended to assess effectiveness and safety of the drug-coated balloon (DCB) angioplasty of infrapopliteal atherosclerotic lesions in patients with critical limb ischaemia (CLI) in a real-world setting. Methods: Consecutive patients with critical limb ischaemia who underwent infrapopliteal drug-coated balloon angioplasty with the ELUTAX SV DCB were enrolled into the prospective, multicentre, single-arm observational registry. Primary outcome was clinical improvement at 6 and 12 months. Secondary outcomes were change in quality of life, primary patency, freedom from repeat revascularisation, and amputation-free survival at 6 and 12 months. Results: A total of 164 patients (74.7 ± 9.2 years) with CLI were included at nine German sites between November 2015 and September 2017. The majority (79.9%) of patients had diabetes mellitus, 57.3% had renal insufficiency, and 35.3% had coronary artery disease. Mean lesion length was 71.2 ± 76.5 mm. The Rutherford category improved by 3.0 ± 2.0 (p < 0.0001) within 12 months, resulting in a clinical improvement by at least one Rutherford category in 80.2% of the patients. Walking impairment questionnaire score, European Quality of Life index, and patient-reported pain improved significantly from baseline to 6 and 12 months. Primary patency was 68.5%, freedom from target lesion revascularisation 90.6%, and amputation-free survival 83.5% at 12 months. Conclusion: Infrapopliteal drug-coated balloon angioplasty with the ELUTAX SV DCB in patients with critical limb ischaemia was efficacious and safe over the medium term. The study is registered with Clinical.Trials.gov (Identifier: NCT02539940).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensory stimulation for upper limb amputations modulates adaptability of cortical large-scale systems and combination of somatosensory and visual inputs

Abstract Touch-like phantom limb sensations can be elicited through targeted transcutaneous electrical nerve stimulation (tTENS) in individuals with upper limb amputation. The corresponding impact of sensory stimulation on cortical activity remains an open question. Brain network research shows that sensorimotor cortical activity is supported by dynamic changes in functional connections between relevant brain regions. These groups of interconnected regions are functional modules whose architecture enables specialized function and related neural processing supporting individual task needs. Using electroencephalographic (EEG) signals to analyze modular functional connectivity, we investigated changes in the modular architecture of cortical large-scale systems when participants with upper limb amputations performed phantom hand movements before, during, and after they received tTENS. We discovered that tTENS substantially decreased the flexibility of the default mode network (DMN). Furthermore, we found increased interconnectivity (measured by a graph theoretic integration metric) between the DMN, the somatomotor network (SMN) and the visual network (VN) in the individual with extensive tTENS experience. While for individuals with less tTENS experience, we found increased integration between DMN and the attention network. Our results provide insights into how sensory stimulation promotes cortical processing of combined somatosensory and visual inputs and help develop future tools to evaluate sensory combination for individuals with amputations.

60 APPLIED LIFE SCIENCES↗

ON THE SOLAR CHROMOSPHERE OBSERVED AT THE LIMB WITH HINODE

Broadband images in the Ca II H line, from the Broadband Filter Imager (BFI) instrument on the Hinode spacecraft, show emission from spicules emerging from and visible right down to the observed limb. Surprisingly, little absorption of spicule light is seen along their lengths. We present formal solutions to the transfer equation for given (ad hoc) source functions, including a stratified chromosphere from which spicules emanate. The model parameters are broadly compatible with earlier studies of spicules. The visibility of Ca II spicules down to the limb in Hinode data seems to require that spicule emission be Doppler shifted relative to the stratified atmosphere, either by supersonic turbulent or organized spicular motion. The non-spicule component of the chromosphere is almost invisible in the broadband BFI data, but we predict that it will be clearly visible in high spectral resolution data. Broadband Ca II H limb images give the false impression that the chromosphere is dominated by spicules. Our analysis serves as a reminder that the absence of a signature can be as significant as its presence.

79 ASTRONOMY AND ASTROPHYSICS↗