Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A 94 GHz RF Electronics Subsystem for the CloudSat Cloud Profiling Radar

The CloudSat spacecraft, scheduled for launch in 2004, will carry the 94 GHz Cloud Profiling Radar (CPR) instrument. The design, assembly and test of the flight Radio Frequency Electronics Subsystem (RFES) for this instrument has been completed and is presented here. The RFES consists of an Upconverter (which includes an Exciter and two Drive Amplifiers (DA's)), a Receiver, and a Transmitter Calibrator assembly. Some key performance parameters of the RFES are as follows: dual 100 mW pulse-modulated drive outputs at 94 GHz, overall Receiver noise figure < 5.0 dB, a highly stable W-band noise source to provide knowledge accuracy of Receiver gain of < 0.4 dB over the 2 year mission life, and a W-band peak power detector to monitor the transmitter output power to within 0.5 dB over life. Some recent monolithic microwave integrated circuit (MMIC) designs were utilized which implement the DA's in 0.1 micron GaAs high electron-mobility transistor (HEMT) technology and the Receiver low-noise amplifier (LNA) in 0.1 micron InP HEMT technology.

radio frequency electronics subsystem (RFES)↗

Results from the CUORE-0 experiment

The CUORE-0 experiment searched for neutrinoless double beta decay in 130 Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130 Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Physics Based Thermo-Well Fatigue Design Tool

In this study, mathematical-based models for fatigue life were developed for Resistance Temperature Detectors (RTDs)/thermo-wells in high-pressure, cryogenic flow environments. A literature review that identified bench-scale stainless steel fatigue data at cryogenic temperatures that can be used to validate fatigue life mathematical models was pursued. Developing the ability to predict the fatigue life of RTDs/thermo-wells in high-pressure, cryogenic flow environments, especially liquid oxygen (LOX), will lead to a lower incidence of RTD damage and failure during propulsion test activities. During this performance period, the project was transitioned to a computational RTD/thermos-well fatigue modeling effort rather than the previously proposed experimental fatigue testing in FY19 since the computational modeling approach will provide a better fundamental understanding of fatigue behavior at cryogenic temperatures prior to pursuing potentially costly experimental tests. Due to COVID-19 issues impairing access to some needed university partnerships, tools and lab facilities, FY20efforts are continuing into FY21 and will be reported upon in greater detail in the FY21 report

Harry Ryan↗

Conversion of experimental half-life to effective electron neutrino mass in 0nubetabeta decay

The Germanium Detector Array (GERDA) collaboration will be searching for neutrinoless double beta decay of {sup 76}Ge. As a result it will measure the half-life T{sub 1/2} of this rare process; or at least a new value for the lower limit for T{sub 1/2} will be derived. The sensitivity of the GERDA experiment on the effective electron neutrino mass <m{sub b}eta{sub b}eta> depends on the theoretical value for the nuclear matrix element M and the kinematical phase space factor G.In this Brief Report we focus on existing difficulties in applying the dimensionless values of M calculated by various theoretical groups, which use different methods and parametrizations. The implicit radius dependencies in M and G are discussed. Resulting values of the neutrino mass are tabulated for various representative half-lives T{sub 1/2} representing the sensitivity of the various phases of the GERDA experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HgZnTe-based detectors for LWIR NASA applications

The initial goal was to grow and characterize HgZnTe and determine if it indeed had the advantageous properties that were predicted. Researchers grew both bulk and liquid phase epitaxial HgZnTe. It was determined that HgZnTe had the following properties: (1) microhardness at least 50 percent greater than HgCdTe of equivalent bandgap; (2) Hg annealing rates of at least 2 to 4 times longer than HgCdTe; and (3) higher Hg vacancy formation energies. This early work did not focus on one specific composition (x-value) of HgZnTe since NASA was interested in HgZnTe's potential for a variety of applications. Since the beginning of 1989, researchers have been concentrating, however, on the liquid phase growth of very long wavelength infrared (VLWIR) HgZnTe (cutoff approx. equals 17 microns at 65K) to address the requirements of the Earth Observing System (EOS). Since there are no device models to predict the advantages in reliability one can gain with increased microhardness, surface stability, etc., one must fabricate HgZnTe detectors and assess their relative bake stability (accelerated life test behavior) compared with HgCdTe devices fabricated in the same manner. Researchers chose to fabricate HIT detectors as a development vehicle for this program because high performance in the VLWIR has been demonstrated with HgCdTe HIT detectors and the HgCdTe HIT process should be applicable to HgZnTe. HIT detectors have a significant advantage for satellite applications since these devices dissipate much less power than conventional photoconductors to achieve the same responsivity.

Patten, Elizabeth A.↗

Long-wave infrared (LWIR) detectors based on III-V materials

Future NASA missions for earth observation and planetary science require large photovoltaic detector arrays with high performance in the long wavelength region to 18 microns and at operating temperatures above 65 K where single-cycle long-life cryocoolers are being developed. Since these detector array requirements exceed the state of current HgCdTe technology, alternative detector materials are being investigated as a possible option for future missions. Advanced growth techniques (e.g., MBE and MOCVD) of column III-V semiconductors have opened opportunities for engineering new detector materials and device structures. The technical approaches under investigation at JPL (with university and industry participation) include: quantum well infrared photodetectors, heterojunction internal photoemission (HIP) photodetectors, type-II strained layer superlattices, and nipi doping superlattices. Each of these options are briefly described with some of their pros and cons. A more detailed description is given for the HIP approach being pioneered at JPL.

Maserjian, Joseph↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Fluorescence decay-time constants in organic liquid scintillators

The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector Low Energy Neutrino Astronomy (LENA). In particular, the impact of the measured values to the search for proton decay via p{yields}K{sup +}{nu} is evaluated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect Measurements of CdZnTe Detectors Using I-DLTS, TCT, I-V and Gamma-ray Spectroscopy

In this work we measured the crystal defect levels and tested the performance of CdZnTe detectors by diverse methodologies, viz., Current Deep Level Transient Spectroscopy (I-DLTS), Transient Current Technique (TCT), Current and Capacitance versus Voltage measurements (I-V and C-V), and gamma-ray spectroscopy. Two important characteristics of I-DLTS technique for advancing this research are (1) it is applicable for high-resistivity materials (>10{sup 6} {Omega}-cm), and, (2) the minimum temperature for measurements can be as low as 10 K. Such low-temperature capability is excellent for obtaining measurements at shallow levels. We acquired CdZnTe crystals grown by different techniques from two different vendors and characterized them for point defects and their response to photons. I-DLTS studies encompassed measuring the parameters of the defects, such as the energy levels in the band gap, the carrier capture cross-sections and their densities. The current induced by the laser-generated carriers and the charge collected (or number of electrons collected) were obtained using TCT that also provides the transport properties, such as the carrier life time and mobility of the detectors under study. The detector's electrical characteristics were explored, and its performance tested using I-V, C-V and gamma-ray spectroscopy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Year PIDDP Report on gamma-ray and x-ray spectroscopy: X-ray remote sensing and in situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. In addition, it is important to characterize a detector system at uneven portions of its life cycle, for example after exposure to different amounts of radiation. A calibration and response characterization facility has been constructed at Schlumberger-Doll Research for all types of gamma- and x-ray detectors that may be used for planetary measurement. This facility is currently being tested. Initial use is expected for the MARS 94 detectors. The facility will then also be available for calibrating other detectors as well as arrays of detectors such as the NEAR detector with its central Nal(TI) crystal surrounded with a large BGO crystal. Cadmium telluride detectors are investigated for applications in space explorations. These detectors show an energy resolution of 5 keV for the 122 keV 57Co line. Earlier reported polarization effects are not observed. The detectors can be used at temperatures up to 100 C, although with reduced energy resolution. The thickness of standard detectors is limited to 2 mm. These detectors become fully efficient at bias voltages above 200 V. Initial results for a 1 cm thick detector show that the quality of the material is inferior to the thinner standard detectors and hole trapping affects the pulse height. A detailed characterization of the detector is in progress. Prototypes of photomultipliers based on a Channel Electron Multiplier (CEM) are being built to study their performance. Such photomultipliers promise better timing characteristics and a higher dynamic range while being more compact and of lower in weight.

Mahdavi, M.↗

A Simple Search for Sterile Neutrino Dark Matter

We have tested the feasibility of an experiment to search for keV sterile neutrino dark matter with superconducting radiation detectors. For this, we have implanted radioactive 7 Be nuclei into our detectors, which decay by electron capture with a half-life of 53 days. The electron neutrino produced in this decay escapes from the detector, and we can measure the recoil energy of the 7 Li daughter nucleus with high accuracy. The recoil spectrum consists of four peaks, two due to capture of a 1s electron (“K-capture”) and two due to capture of a 2s electron (“L-capture”) for decay into the 7 Li ground state and the 7 Li* excited state. If the electron neutrino contains some admixture of a keV sterile neutrino, the 7 Li recoil energy will be shifted and produce an additional peak in the spectrum whose energy depends on the sterile neutrino mass and whose amplitude depends on the neutrino admixture.

42 ENGINEERING↗

New isomers and medium-spin structure of the {sup 95}Y nucleus

Excited states in {sup 95}Y, populated following the spontaneous fission of {sup 248}Cm and {sup 252}Cf and following fission of {sup 235}U induced by thermal neutrons, were studied by means of {gamma} spectroscopy using the EUROGAM2 and GAMMASPHERE multidetector Ge arrays and the LOHENGRIN fission-fragment separator, respectively. We have found a new (17/2{sup -}) isomer in {sup 95}Y at 3142.2 keV with a half-life of T{sub 1/2}=14.9(5) ns. Another isomer was identified in {sup 95}Y at 5022.1 keV and it was assigned a spin-parity (27/2{sup -}). For this isomer a half-life of T{sub 1/2}=65(4) ns was determined and four decay branches were found, including an E3 decay. A new E3 decay branch was also found for the known, 1087.5-keV isomer in {sup 95}Y, for which we measured a half-life of 51.2(9) {mu}s. The B(E3) and B(E1) transition rates, of 2.0 and 3.8x10{sup -7} W.u., respectively, observed in {sup 95}Y are significantly lower than in the neighboring {sup 96}Zr core, suggesting that octupole correlations in this region are mainly due to the coupling of proton {delta}j=3 orbitals. Shell-model calculations indicate that the (27/2{sup -}) isomer in {sup 95}Y corresponds to the {pi}g{sub 9/2}{nu}(g{sub 7/2}h{sub 11/2}) maximally aligned configuration and that all three isomers in {sup 95}Y decay, primarily, by M2 transitions between proton g{sub 9/2} and f{sub 5/2} orbitals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutrino-less Double Beta Decay of {sup 48}Ca-CANDLES

Neutrino-less double beta decay (0{nu}{beta}{beta}) is currently known to be an only experiment to verify whether lepton number is conserved or not. The lepton number non-conservation is the key to create matter dominated universe with CP violation. The so-called leptogenesys scenario presents a way to create the matter dominated universe by these violations. If neutrinos have Majorana mass, transition from a particle to an anti-particle is possible and the left-handed and right-handed neutrinos could have different masses. It is highly likely that the neutrinos are Majorana particles. We have been studying double beta decay of {sup 48}Ca. Our first stage experiment using the ELEGANT VI detector system gave the best lower limit of the half life of 0{nu}{beta}{beta} of {sup 48}Ca. We have been working on CANDLES detector system to sense much longer lifetime region. We have developed techniques to reduce backgrounds. The CADLES detector system was installed at Kamioka underground laboratory. Here I describe a schematic view of the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beta Decay Study of the T{sub z}=−2{sup 56}Zn Nucleus and the Determination of the Half-Lives of a Few fp-shell Nuclei

This paper concerns the experimental study of the β decay properties of few proton-rich fp-shell nuclei. The nuclei were produced at GANIL in fragmentation reactions, separated with the LISE spectrometer and stopped in an implantation detector surrounded by Ge detectors. The β-delayed gammas, β-delayed protons and the exotic β-delayed gamma-proton emission have been studied. Preliminary results are presented. The decay of the T{sub z}=−2 nucleus {sup 56}Zn has been studied in detail. Information from the β-delayed protons and β-delayed gammas has been used to deduce the decay scheme. The exotic beta-delayed gamma-proton decay has been observed for the first time in the fp-shell. The interpretation of the data was made possible thanks to the detailed knowledge of the mirror Charge Exchange (CE) process and the gamma de-excitation of the states in {sup 56}Co, the mirror nucleus of {sup 56}Cu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of rain age via {gamma} rays from accreted radon progeny

The relative {gamma} ray activities from {sup 214}Pb and {sup 214}Bi condensed from precipitation are used to determine its 'age', the average time the accreted activity has been removed from secular equilibrium. A verifiable assumption that radon progeny on/in the surface/volume of droplets mostly remains in secular equilibrium until they begin their descent, enables estimates of their transit times to ground of typically a few tens of minutes. This agrees well with the time expected for the activity on the surface of droplets to reach the ground from heights of a few kilometers. The half lives of {gamma} activities from {sup 214}Bi and {sup 214}Pb, 19.7 and 26.9 min, respectively, are on the same scale as transit time to ground and close enough to each other to measure ratios of activities from secular equilibrium (1.00) to transient equilibrium (3.88) within a few hundreds of minutes. The ratio of {gamma} count rates is independent of knowledge of either initial activity or any systematic errors and thus limited only by the uncertainty from counting statistics, which from condensates of 5-30 l of rain viewed with 2{pi} solid angle by a 50% efficient, high-resolution Ge detector is only a few percent. These ratios fit extremely well to known theoretical curves, which cannot only be used to date rain but can also be extrapolated backward to determine radon progeny activities in rain prior to its descent, knowledge of which may facilitate further studies using radon progeny as tracers.

54 ENVIRONMENTAL SCIENCES↗

Investigation of {beta} decay of {sup 113}Cd

{beta} decay of {sup 113}Cd was studied with the help of a low background CdWO{sub 4} crystal scintillator (mass of 434 g) in an experiment at the Gran Sasso National Laboratories of the INFN for a period of 2758 h. The shape of the spectrum of the non-unique fourth-forbidden decay of {sup 113}Cd was measured, and the half-life of {sup 113}Cd was determined as T{sub 1/2}=(8.04{+-}0.05)x10{sup 15} yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A radon progeny deposition model

The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly {sup 222}Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of {sup 210}Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experiment TGV II - results of Phases I and II

Currently, the TGV collaboration is investigating the two-neutrino double electron capture (2vEC/EC) of {sup 106}Cd at the Modane underground laboratory. The study is performed with low-background multi-HPGe detector TGV II, which has been constructed for measurements of the rare processes. The half-life limits of T{sub 1/2}>2.6x10{sup 20} years(for Phase I, 8687 hours) and T{sub 1/2}>3.6x10{sup 20} years(for Phase II, 9003 hours) were obtained for the ground state to ground state 2vEC/EC of {sup 106}Cd. The results already allow to rule out some of the previous nuclear structure calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗