Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIBS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗

Laser Ablation Surface Treatment of Structural Aerospace Composites and Metal Alloys for Adhesive Bonding

NASA Langley Research Center (LaRC) has been involved over the past decade in the development of laser ablation as a method to surface treat aerospace structural fiber reinforced composites (CFRPs) and metal alloys. [1- 18] Laser surface treatment has been shown to be a rapid, high precision, and reproducible method for surface treatment of these materials, and is amenable to automation. The laser ablation process removes surface contamination such as silicones, creates surface roughness, and chemically activates a surface for bonding. The degree of ablation is controllable by adjusting laser parameters. In the case of CFRPs, ablation can be performed without damage to any underlying carbon fibers. In the case of metal alloys, ablation is possible without surface embrittlement, heat damage or creation of undesirable grain structures or morphologies. The optimum laser treatment conditions are substrate dependent and generally are influenced by laser wavelength and pulse duration (typically fixed for a laser system), and laser power. In the case of metal alloys such as Ti-6Al-4V, the laser ablation process eliminates the need for several steps of the conventional processes, including hydrofluoric (HF) acid and caustic treatment. These steps are often conducted in dip tanks and require costly facilities and environmentally unfriendly liquids. In addition, the laser can create nano-porosity on the Ti-6Al-4V alloy surface allowing for sol-gel penetration and thereby creating a gradient interface with improved temperature and mechanical performance. NASA LaRC has also been involved with the development of in-line characterization methods compatible with the laser treatment process to rapidly determine the presence of key contaminates such as silicones that, even at very low concentrations, are a threat to adhesive bonding. A spectroscopic technique called micro-laser induced breakdown spectroscopy (u-LIBS) has been developed to rapidly detect silicones at concentrations below those known to cause bonding problems. This technique requires no sample preparation, vacuum or inert atmosphere, has no practical size limitations, and provides nearly instantaneous feedback to the operator. This presentation will give an overview and update of these developments with specific examples highlighted.

Connell, John W.↗

Design and Development of Advanced Air-Cathodes for Li-Air Battery

NASA's future missions demand high energy density batteries. Current state-of-the-art lithium-ion batteries (LIBs) reach the specific energy capacity limits (<250 Wh/kg), thus new electrochemical storage technologies are needed to meet NASA's future mission requirement of >400 Wh/kg. Battery chemistries with higher theoretical energy densities in particular, Li-metal based battery chemistries such as Li-air, are being actively pursued, but there remains a number of issues to be solved. Development of advanced and optimized air cathodes will be crucial for improving capacity retention and cycle life of Li-air battery. The microstructure of carbon substrates and the catalytic oxygen reduction of the air-cathode play critical roles in the electrochemical performance in Li-air batteries. With the development and proper design of air cathodes, the energy efficiency and energy density can be enhanced significantly. In this presentation, the results of advanced permeable air cathodes design with different substrates such as 2D carbon paper or carbon cloth, vs 3D graphene or metal foam, different high surface area carbon materials and incorporation with catalysts on oxygen reduction reactions, different porosity controlling of air cathode as well the additives in electrolyte will be presented. The cycling and rate capability performance of these air-cathodes in the Li-air cells will be discussed as well.

Wu, James J.↗

Using Mineralchemistry in Gale Crater Sedimentary Rocks to Constrain Ancient Igneous Processes on Mars

Over the last decade, various datasets have shown evidence for unexpected Noachian felsic materials at the surface of Mars. The Martian meteorite NWA 7034, also well-known as Black Beauty, has been identified as a regolith breccia containing mafic clasts along with remarkable felsic igneous clasts dated at 4.43 Gyr and classified as monzonitic [1-2]. In addition, the Curiosity rover has been analyzing felsic materials within Gale crater since its landing in 2012 [3-4]. The X-ray diffractometer (XRD) in the CheMin instrument and the laser induced breakdown spectrometer (LIBS) ChemCam onboard Curiosity identified plagioclase and K-spar along with augite and pigeonite [3-5]. In sedimentary rocks, those minerals are detrital, coming from a magmatic source of Noachian age that was sufficiently evolved to form K-spar [1,6]. Several igneous materials analyzed by Chem- Cam have been classified as part of the alkaline trend including Harrison, a trachy-andesite [7].

Payre, V.↗

Development of Solid State Electrolytes for Li-Metal Based High Capacity Battery

NASA future missions demand safe, high specific energy (>400 Wh/kg) batteries. Current state-of-the-art (SOA) lithium-ion batteries (LIBs) can only provide ~150-200 Wh/kg in energy capacity, which is unable to meet NASA's future energy goals, and also pose safety issues due to the use of liquid flammable electrolyte. There are intense on-going development activities to increase battery energy density. The use of Li metal as an anode material has emerged as one highly attractive option for achieving high-energy, next generation batteries. This is because Li has many advantages. It is the lightest metal, but also has the highest theoretical capacity. It also has the lowest potential, which boosts whole cell voltage, and Li metal is 100% active material and requires no binder. Thus, Li metal is an ideal anode material for high energy battery chemistries. Lithium metal based advanced battery chemistries are envisioned to be mission enhancing and, in many cases, mission enabling for future space and aeronautic applications. However, the reliable use of this exceptionally high capacity anode in a commercial rechargeable battery has not been achieved due to safety and reliability concerns resulting from thermal runaway and short-circuit issues due to dendritic growth on the Li metal anode from lithium plating during charge-discharge cycles. A solid state electrolyte, such as garnet/ceramic or solid polymer nanocomposite electrolyte, is a promising approach to make Li metal safely cycling. The solid state electrolyte is non-flammable and eliminates leakage and fire hazard by replacing the liquid flammable electrolyte. However, the low-ionic conductivity and high interfacial impedance are the key issues to be overcome. In this presentation, the research activities on solid state electrolyte development funded by the NASA Advanced Energy Storage System program and by the NASA Center Innovative Fund will be presented, and the progress and results will be also discussed.

Wu, James J.↗

Characterisation of Float Rocks at Ireson Hill, Gale Crater

Float rocks discovered by surface missions on Mars have given unique insights into the sedimentary, diagenetic and igneous processes that have operated throughout the planet’s history. In addition, Gale sedimentary rocks, both float and in situ, record a combination of source compositions and diagenetic overprints. We examine a group of float rocks that were identified by the Mars Science Laboratory mission’s Curiosity rover at the Ireson Hill site, circa. sol 1600 using ChemCam LIBS, APXS and images from the MastCam, Mars Hand Lens Imager (MAHLI) and ChemCam Remote Micro-Imager (RMI) cameras. Geochemical data provided by the APXS and ChemCam instruments allow us to compare the compositions of these rocks to known rock types from Gale crater, as well as elsewhere on Mars. Ireson Hill is a 15 m long butte in the Murray formation with a dark cap-ping unit with chemical and stratigraphic consistency with the Stimson formation. A total of 6 float rocks have been studied on the butte.

Bowden, D. L.↗

Apatites in Gale Crater

ChemCam is an active remote sensing instrument suite that has operated successfully on MSL since landing Aug. 6th, 2012. It uses laser pulses to remove dust and to analyze rocks up to 7 m away. Laser-induced breakdown spectroscopy (LIBS) obtains emission spectra of materials ablated from the samples in electronically excited states. The intensities of the emission lines scale with the abundances of the related element. ChemCam is sensitive to most major rock-forming elements as well as to a set of minor and trace elements such as F, Cl, Li, P, Sr, Ba, and Rb. The measured chemical composition can then be used to infer the mineralogical composition of the ablated material. Here, we report a summary of inferred apatite detections along the MSL traverse at Gale Crater. We present the geologic settings of these findings and derive some interpretations about the formation conditions of apatite in time and space.

Forni, O.↗

Optimization of Picosecond Laser Parameters for Surface Treatment of Composites Using a Design of Experiments (DOE) Approach

Based on guidelines from the Federal Aviation Administration, research supported by the NASA Advanced Composites Project is investigating methods to improve process control for surface preparation and pre-bond surface characterization on aerospace composite structures. The overall goal is to identify high fidelity, rapid, and reproducible surface treatments and surface characterization methods to reduce the uncertainty associated with the bonding process. The desired outcome is a more reliable bonded airframe structure, and to reduce time to achieve certification. In this work, a design of experiments (DoE) approach was conducted to determine optimum laser ablation conditions using a pulsed laser source with a nominal pulse width of 10 picoseconds. The laser power, frequency, scan speed, and number of passes (1 or 2) were varied within the laser system operating boundaries. Aerospace structural carbon fiber reinforced composites (Torayca® 3900-2/T800H) were laser treated, then characterized for contamination, and finally bonded for mechanical testing. Pre-bond characterization included water contact angle (WCA) using a handheld device, ablation depth measurement using scanning electron microscopy (SEM), and silicone contamination measurement using laser induced breakdown spectroscopy (LIBS). In order to accommodate the large number of specimens in the DoE, a rapid-screening, double cantilever beam (DCB) test specimen configuration was devised based on modifications to ASTM D5528. Specimens were tested to assess the failure modes observed under the various laser surface treatment parameters. The models obtained from this DoE indicated that results were most sensitive to variation in the average laser power. Excellent bond performance was observed with nearly 100% cohesive failure for a wide range of laser parameters. Below about 200 mW, adhesive failure was observed because contamination was left on the surface. For laser powers greater than about 600 mW, large amounts of fiber were exposed, and the failure mode was predominately fiber tear.

Palmieri, Frank L.↗

Dating Igneous Rocks Using the Potassium–Argon Laser Experiment (KArLE) Instrument: A Case Study for ~380 Ma Basaltic Rocks

We report new K–Ar isochron data for two ~380 Ma basaltic rocks, using an updated version of the Potassium–Argon Laser Experiment (KArLE), which is being developed for future in situ dating of planetary materials. These basalts have K contents comparable with those of lunar KREEP basalts or igneous lithologies found by Mars rovers, whereas previous proof‐of‐concept studies focused primarily on more K‐rich rocks. We aim to measure these analogous samples to show the advancing capability of in situ K–Ar geochronology. Combining laser‐induced breakdown spectroscopy (LIBS), mass spectrometry (MS), and microscopic analyses, we measured the abundance of K and 40Ar from 23 spots on the basalt samples. We then constructed K–Ar isochron plots from these rocks. The breadboard instrument consists of flight‐equivalent devices including a 30‐mJ Nd:YAG laser and a quadrupole mass spectrometer. Despite much lower K abundances than in previous studies, the isochron slopes yielded 380 ± 44 Ma and 398 ± 50 Ma for 380.7‐Ma and 373.5‐Ma rocks, respectively, indicating that accuracy better than 25 Ma (<7%) is achievable with our instrument. The isochron intercepts both yielded trapped 40Ar approximately 1 × 10−6 cm3 STP/g. Our experimental results demonstrate that accurate and precise measurements are possible using the KArLE approach on basaltic rocks, which are ubiquitous on planetary surfaces, and are useful in addressing a wide range of questions in planetary science.

Yuichiro Cho↗

Composition and Density Stratification Observed by SuperCam in the First 300 Sols in Jezero Crater

The Perseverance rover has traveled > 2.5 km since leaving its Octavia Butler landing site in Jezero crater ~300 sols ago. The SuperCam remote sensing instrument suite has made > 1000 observations of bedrock along the traverse to provide a comprehensive picture of Jezero crater floor’s chemistry and mineralogy. SuperCam combines high resolution imaging, visible and near-infrared (VISIR) reflectance spectroscopy (0.4-0.85, 1.3-2.6 µm), remote time-resolved green-laser Raman and fluorescence spectroscopy, laser-induced breakdown spectroscopy (LIBS), and acoustic sensing into a single co-boresighted package [1, 2]. Derivation of the major element abundances as oxide wt% for this part of the mission is presented in [3], while calibration of the VIS and IR spectrometers are given in [4-7].

R.C. Wiens↗

Using the Potassium-Argon Laser Experiment (KArLE) to Date Ancient, Low-K Chondritic Meteorites

Several laboratories have been investigating the feasibility of in situ K-Ar dating for use in future landing planetary missions. One drawback of these laboratory demonstrations is the insufficient analogy of the analyzed analog samples with expected future targets. We present the results obtained using the K-Ar laser experiment (KArLE) on two old and K-poor chondritic samples, Pułtusk and Hvittis, as better lunar analogs. The KArLE instrument uses laser ablation to vaporize rock samples and quantifies K content by laser-induced breakdown spectroscopy (LIBS), Ar by quadrupole mass spectrometry (QMS), and ablated mass by laser profilometry. We performed 64 laser ablations on the chondrites to measure spots with a range of K 2 O and Ar content and used the data to construct isochrons to determine the chondrite formation age. The KArLE isochron ages on Pułtusk and Hvittis are 5059 ± 892 Ma and 4721 ± 793 Ma, respectively, which is within the uncertainty of published reference ages, and interpreted as the age of their formation. The uncertainty (2σ) on the KArLE ages obtained in this study is better than 20% (18% for Pułtusk and 17% for Hvittis). The precision, which compares our obtained ages to the reference ages, is also better than 20% (11% for Pułtusk and 4% for Hvittis). These results are encouraging for understanding the limits of this technique to measure ancient planetary samples and for guiding future improvements to the instrument.

Fanny Cattani↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele [1] is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations (Figure 1). The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow [1] (single-body sample capture system), DAVINCI [2] and Venera-D [3] (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

The Center for Isotope Cosmochemistry and Geochronology (CICG) at the NASA Johnson Space Center, led by Justin Simon, applies novel elemental and isotopic analytical techniques to understand solar system formation, from processes occurring during the earliest Solar Nebula, to the evolution of planetary bodies during planet formation and differentiation. CICG consists of an integrated suite of labs including dedicated spaces for specialized handling and preparation of meteorites and planetary return samples, metal-free clean chemistry, and mass spectrometry. In addition to a Thermo-Scientific Triton thermal ionization mass spectrometer (TIMS) for high precision isotopic analyses in processed samples, CICG houses two additional mass spectrometry instruments with added laser ablation capabilities for high spatial resolution in-situ measurements: (1) a Thermo-Scientific Element-XR inductively coupled mass spectrometer (ICP-MS) with a Teledyne Photon Machines Analyte Excite+ laser ablation system, and (2) a Nu Sapphire 1700 multi-collector ICP-MS, a large geometry instrument with a multi-pole collision cell for interference removal, with an Applied Spectra J200 tandem laser induced breakdown spectroscopy (LIBS) femto-second laser ablation system. We detail the analytical capabilities of CICG in the context of current and future research projects related to the studies of protoplanetary disk evolution via early-formed Solar System solids, volatile abundances and distribution within the inner solar system, and geochemical and temporal investigations related to planet formation and differentiation. We also highlight opportunities through the relationship with the Center of the Advancement of Space Safety and Mission Assurance Research (CASSMAR) at the University of Texas at El Paso. CICG is open to collaborations and participates in the NASA Facility for Astromaterials Research (NFAR) program, which accepts research proposals for access to the unique facility capabilities.

Jacob B. Setera↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations. The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow (single-body sample capture system), DAVINCI and Venera-D (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Mineral composition of Al-rich float rocks in Jezero crater as seen by Super-Cam

During its traverse across the Jezero crater floor and western fan, the Perseverance rover encountered > 4000 float rocks – of variable size (up to ~ 50 cm) scattered on the ground without apparent connection to the surrounding stratigraphy [1]. Analysis performed using the SuperCam instrument’s [2,3,4], Laser Induced Breakdown Spectroscopy (LIBS) revealed a high concentration of Al 2 O 3 , Cr, Ti and Ni [5], and very low of Fe, Mg, Ca and Na [5, 1]. SuperCam’s infrared reflectance spectroscopy (IRS, between 1.3 and 2.6 μm) showed the presence of Al-rich aqueous alteration minerals (characteristic absorption bands of kaolinite and Al-smectites at 1.4 and 2.2 μm) as well as some (likely Cr-) spinels, identified uthrough their broad asymmetric 2 μm band, responsible for the concavity of IR spectra. These mineral species alone do not fully account for the spectral shapes; hence, the objective is to further investigate spectral modeling to determine the most probable mineral assemblages. Here, we present the results of modeling 17 light-toned float rocks, up to Sol 924, complementary to [1].

C. Royer↗

Viscosity and Flow Properties of the Seitah Olivine-Rich Lithology

One of the most surprising findings of the Perseverance rover was the discovery of olivine cumulate in the Séítah region [1]. The rover landed and traversed to the Séítah region and collected measurements at three workspaces: Bastide, Brac and Issole (Fig 1). Here we use the SuperCam VISIR and LIBS to investigate the properties of the lithology insitu and determine two things: 1) the olivine-clay-carbonate regional lithology is low in Al3+, which allows us to eliminate the possibility of clays which are high in Al3+, 2) the viscosity of the Séítah formation is extremely low, which is a reasonable explanation for the Séítah unit to both cumulate and thin-layered (Fig 1b).

Mars 2020↗

Optical Spectroscopy of Venus Aerosol Analogs and Substrate Survivability

Aerosol Rapid Analysis Combined Entry Probe/Sonde Technology (AERACEPT) is a dual descent probe and in-situ sampler of cloud and aerosol particles, used as part of the Nephele mission concept to study Venus cloud layers. Various optical spectroscopic characterization methods, including Raman spectroscopy and Surface Enhanced Raman Spectroscopy (SERS), Laser induced Breakdown Spectroscopy (LIBS), and absorbance and fluorescence spectroscopy are being assessed for viability for compatibility with AERACEPT. Specifically, the detection limits, sensitivity, specificity, and analysis cadence of these techniques for a set of Venus aerosol analogs and their mixtures are tested. We report on preliminary optical spectroscopy results of the Venus aerosol analogs, as well as optical substrate survivability in heated and acidic conditions, substrate physical robustness, and analyte wettability on substrates.

Venus↗

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology: Enabling In Situ Aerosol Science for Small Spacecraft Missions

AERACEPT is an early-stage technology combining an entry vehicle and descent probe in a single aeroshell instrumented for aerosol particle sampling.This approach combines previous technology demonstrations of sampling through an aeroshell body and well-established particle sampling techniques from airborne science with modern advances in thermal protection materials such as 3D woven carbon-carbon and HEEET. It is designed to be compatible with robust, fast cadence, low power, small footprint analysis instruments such as LIBS, SERS, and UV fluorescence. It is particularly well suited to a Venus mission, as the particles of interest will be in the subsonic regime of a passive descent, and is included as part of the Nephele Venus small spacecraft mission concept.

aerosol↗