Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

GaN photovoltaic leakage current and correlation to grain size

GaN p-i-n solar PV structures grown by rf plasma assisted molecular beam epitaxy (MBE) produce high performance IV characteristics with a leakage current density of less than 1x10{sup -4} mA cm{sup -2} at 0.1 V forward bias and an on-resistance of 0.039 {Omega} cm{sup 2}. Leakage current measurements taken for different size diodes processed on the same sample containing the solar cells reveal that current density increases with diode area, indicating that leakage is not a large function of surface leakage along the mesa. Nonannealed Pt/Au Ohmic p-contacts produce a contact resistivity of 4.91x10{sup -4} {Omega} cm{sup -2} for thin Mg doped contact layers with sheet resistivity of 62196 {Omega}/{open_square}. Under concentrated sunlight the cells produce an open-circuit voltage of 2.5 V and short circuit currents as high as 30 mA cm{sup -2}. Multiple growths comprised the study and on each wafer the IV curves representing several diodes showed considerable variation in parasitic leakage current density at low voltages on some wafers and practically no variation on others. It appears that a smaller grain size within the GaN thin film accounts for higher levels of dark current.

36 MATERIALS SCIENCE↗

Temperature-dependent analysis of conduction mechanism of leakage current in thermally grown oxide on 4H-SiC

The conduction mechanism of the leakage current of a thermally grown oxide on 4H silicon carbide (4H-SiC) was investigated. The dominant carriers of the leakage current were found to be electrons by the carrier-separation current-voltage method. The current-voltage and capacitance-voltage characteristics, which were measured over a wide temperature range, revealed that the leakage current in SiO{sub 2}/4H-SiC on the Si-face can be explained as the sum of the Fowler-Nordheim (FN) tunneling and Poole-Frenkel (PF) emission leakage currents. A rigorous FN analysis provided the true barrier height for the SiO{sub 2}/4H-SiC interface. On the basis of Arrhenius plots of the PF current separated from the total leakage current, the existence of carbon-related defects and/or oxygen vacancy defects was suggested in thermally grown SiO{sub 2} films on the Si-face of 4H-SiC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comprehensive study of the impact of dislocation loops on leakage currents in Si shallow junction devices

In this work, the electrical properties of dislocation loops and their role in the generation of leakage currents in p-n or Schottky junctions were investigated both experimentally and through simulations. Deep Level Transient Spectroscopy (DLTS) reveals that the implantation of silicon with 2 × 10{sup 15} Ge cm{sup −2} and annealing between 1000 °C and 1100 °C introduced two broad electron levels E{sub C} − 0.38 eV and E{sub C} − 0.29 eV in n-type samples and a single broad hole trap E{sub V} + 0.25 eV in the p-type samples. These trap levels are related to the extended defects (dislocation loops) formed during annealing. Dislocation loops are responsible for the significant increase of leakage currents which are attributed to the same energy levels. The comparison between structural defect parameters and electrical defect concentrations indicates that atoms located on the loop perimeter are the likely sources of the measured DLTS signals. The combined use of defect models and recently developed DLTS simulation allows reducing the number of assumptions and fitting parameters needed for the simulation of leakage currents, therefore improving their predictability. It is found that simulations based on the coupled-defect-levels model reproduce well the measured leakage current values and their field dependence behaviour, indicating that leakage currents can be successfully simulated on the exclusive basis of the experimentally observed energy levels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the neutron leakage from a dedicated intraoperative radiation therapy electron linear accelerator and a conventional linear accelerator for 9, 12, 15(16), and 18(20) MeV electron energies

The issue of neutron leakage has recently been raised in connection with dedicated electron-only linear accelerators used for intraoperative radiation therapy (IORT). In particular, concern has been expressed about the degree of neutron production at energies of 10 MeV and higher due to the need for additional, perhaps permanent, shielding in the room in which the device is operated. In particular, three mobile linear accelerators available commercially offer electron energies at or above the neutron threshold, one at 9 MeV, one at 10 MeV, and the third at 12 MeV. To investigate this problem, neutron leakage has been measured around the head of two types of electron accelerators at a distance of 1 m from the target at azimuthal angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg. The first is a dedicated electron-only (nonmobile) machine with electron energies of 6 (not used here), 9, 12, 15, and 18 MeV and the second a conventional machine with electron energies of 6 (also not used here), 9, 12, 16, and 20 MeV. Measurements were made using neutron bubble detectors and track-etch detectors. For electron beams from a conventional accelerator, the neutron leakage in the forward direction in Sv/Gy is 2.1x10{sup -5} at 12 MeV, 1.3x10{sup -4} at 16 MeV, and 4.2x10{sup -4} at 20 MeV, assuming a quality factor (RBE) of 10. For azimuthal angles >0 deg., the leakage is almost angle independent [2x10{sup -6} at 12 MeV; (0.7-1.6)x10{sup -5} at 16 MeV, and (1.6-2.9)x10{sup -5} at 20 MeV]. For the electron-only machine, the neutron leakage was lower than for the conventional linac, but also independent of azimuthal angle for angles >0 deg. : ([0 deg. : 7.7x10{sup -6} at 12 MeV; 3.0x10{sup -5} at 15 MeV; 1.0x10{sup -4} at 18 MeV]; [other angles: (2.6-5.9)x10{sup -7} at 12 MeV; (1.4-2.2)x10{sup -6} at 15 MeV; (2.7-4.7)x10{sup -6} at 18 MeV]). Using the upper limit of 6x10{sup -7} Sv/Gy at 12 MeV for the IORT machine for azimuthal angles >0 deg. and assuming a workload of 200 Gy/wk and an inverse square factor of 10, the neutron dose equivalent is calculated to be 0.012 mSv/wk. For the primary beam at 12 MeV (0 deg. ), the 10x higher dose would be compensated by the attenuation of a primary beam stopper in a mobile linear accelerator. These neutron radiation levels are below regulatory values (National Council on Radiation Protection and Measurements, 'Limitation of exposure to ionizing radiation', NCRP Report No. 116, NCRP Bethesda, MD, 1993)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

dielectric polarization↗

Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

testing↗

Calculation of Transformer Leakage Inductance by Simplified Flux Path Geometries

Series inductance is a critical energy storage element in isolated power converters. Many have explored methods of estimating the total leakage inductance of transformers as an integrated series inductance without external inductors. However, this poses challenges with medium frequency converters and magnetic ribbon-based cores, e.g., metal amorphous nanocrystalline. The material’s relatively high conductivity allows eddy currents to develop when magnetic flux intersects wide surfaces. These eddy currents result in significant additional losses that increase with increasing power flow. This paper presents a simplified and accurate method of estimating leakage flux while identifying separate leakage flux paths that correlate with the magnetic material surfaces. This enables an understanding the proportion of leakage flux that will contribute to extra losses. The methods presented are applicable to both leakage and fringing (around heterogeneous material interfaces) fluxes. This paper includes detailed FEA studies and 3D flux vector measurements matching the presented analytical models.

transformer↗

A harmonic pulse testing method for leakage detection in deep subsurface storage formations

Abstract Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy‐to‐implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant‐rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT‐based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time‐lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single‐phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT‐based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost‐effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

Sun, Alexander Y.↗

Modeling the potential impacts of CO 2 sequestration on shallow groundwater: The fate of trace metals and organic compounds before and after leakage stops

Large-scale deployment of CO 2 geological sequestration requires understanding and assessing the risks of such an operation. One of these risks is the potential contamination of groundwater by CO 2 /brine leakage into shallow aquifers. Although our understanding of this issue has improved significantly over the last decade, several questions still need to be better addressed, including the fate of organic constituents, the dominant source of trace metals (are they mainly coming from aquifer sediments, or leaking brine), and whether the trace metals released during the leakage phase recover to background levels if the leakage were to be detected and stopped. In this paper, reactive transport simulations that model the behavior of trace metals and organic compounds in response to the leakage of CO 2 and brine into a shallow aquifer are presented to address these questions. Model results show that the metals and organic compounds brought by the leaking brine form a plume at the bottom of the aquifer because the density of the brine is higher than that of groundwater. In contrast, metals are mobilized by CO 2 over a larger vertical extent because of the spreading of gaseous CO 2 by buoyancy. The concentration of organic contaminants is strongly attenuated by adsorption and degradation, with degradation playing the major role in the modeled scenarios. Although the leaking brine is assumed to contain elevated concentrations of As, Pb, Cd, and Ba, it does not contribute significantly to the contamination of the modeled shallow aquifer by these elements. Once the leakage stops, mobilized organic compounds that undergo degradation vanish, while less degradable compounds linger for a longer time; the dissolved concentrations of trace metals decrease significantly, as a result of re-sorption and reversal of processes leading to Ca-driven cation exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detecting inter-aquifer leakage in areas with limited data using hydraulics and multiple environmental tracers, including {sup 4}He, {sup 36}Cl/Cl, {sup 14}C and {sup 87}Sr/{sup 86}Sr

The investigation of regionally extensive groundwater systems in remote areas is hindered by a shortage of data due to a sparse observation network, which limits our understanding of the hydrogeological processes in arid regions. The study used a multidisciplinary approach to determine hydraulic connectivity between the Great Artesian Basin (GAB) and the underlying Arckaringa Basin in the desert region of Central Australia. In order to manage the impacts of groundwater abstraction from the Arckaringa Basin, it is vital to understand its connectivity with the GAB (upper aquifer), as the latter supports local pastoral stations and groundwater-dependent springs with unique endemic flora and fauna. The study is based on the collation of available geological information, a detailed analysis of hydraulic data, and data on environmental tracers. Enhanced inter-aquifer leakage in the centre of the study area was identified, as well as recharge to the GAB from ephemeral rivers and waterholes. Throughout the rest of the study area, inter-aquifer leakage is likely controlled by diffuse inter-aquifer leakage, but the coarse spatial resolution means that the presence of additional enhanced inter-aquifer leakage sites cannot be excluded. This study makes the case that a multi-tracer approach along with groundwater hydraulics and geology provides a tool-set to investigate enhanced inter-aquifer leakage even in a groundwater basin with a paucity of data. A particular problem encountered in this study was the ambiguous interpretation of different age tracers, which is attributed to diffusive transport across flow paths caused by low recharge rates.

58 GEOSCIENCES↗

A collaborative detection approach for internal steam leakage of tyre vulcanization workshop with artificial immune algorithm

In manufacturing industry, internal leakage of steam trap usually results in great steam waste. In particular, internal steam leakage in tyre vulcanization workshop has significant influences on its production safety and energy efficiency. In practice, internal steam leakage problem often is ignored and it tends to be difficult to detect this leakage due to lack of comprehensive flow meter or method. This paper presents a collaborative detection method for this problem in tyre vulcanization workshop with artificial immune algorithm. In the method, internal leakage of steam trap is defined as nonself antigens, and steam pressure differentials between steam pipe and steam rooms (or bladders) are extracted as epitopes of antigens. Furthermore, periodic energy efficiency and steam pressure of vulcanizer as the danger signals are simultaneously detected. Energy efficiency is represented by damaged cells which will be identified firstly for locating the leaking steam straps through antibodies. Furthermore, the self-adaptive danger thresholds for energy efficiency are evaluated through a steam consumption model and the Levenberg–Marquardt back propagation algorithm. An immune-based clustering algorithm aiNet is then adopted to generate antibodies (detectors) for detection on the steam pressure of vulcanizer. Finally, a case study is implemented to validate this method, which shows that collaborative detection method allows locating the specific leaking steam trap and is a feasible tool to reduce steam waste and ensure the safety of steam supply.

42 ENGINEERING↗

Experimental observation of signature changes in bulk soil electrical conductivity in response to engineered surface CO2 leakage

Experimental observations of signature changes of bulk soil electrical conductivity (EC) due to CO{sub 2} leakage were carried out at a field site at Bozeman, Montana, to investigate the change of soil geophysical properties in response to possible leakage of geologically sequestered CO{sub 2}. The dynamic evolution of bulk soil EC was measured during an engineered surface leakage of CO{sub 2} through in situ continuous monitoring of bulk soil EC, soil moisture, soil temperature, rainfall rate, and soil CO{sub 2} concentration to investigate the response of soil bulk EC signature to CO{sub 2} leakage. Observations show that: (1) high soil CO{sub 2} concentration due to CO{sub 2} leakage enhances the dependence of bulk soil EC on soil moisture. The bulk soil EC is a linear multivariate function of soil moisture and soil temperature, the coefficient for soil moisture increased from 2.111 dS for the non-leaking phase to 4.589 dS for the CO{sub 2} leaking phase; and the coefficient for temperature increased from 0.003 dS/C for the non-leaking phase to 0.008 dS/C for the CO{sub 2} leaking phase. The dependence of bulk soil EC on soil temperature is generally weak, but leaked CO{sub 2} enhances the dependence, (2) after the CO{sub 2} release, the relationship between soil bulk EC and soil CO{sub 2} concentration observes three distinct CO{sub 2} decay modes. Rainfall events result in sudden changes of soil moisture and are believed to be the driving forcing for these decay modes, and (3) within each mode, increasing soil CO{sub 2} concentration results in higher bulk soil EC. Comparing the first 2 decay modes, it is found that the dependence of soil EC on soil CO{sub 2} concentration is weaker for the first decay mode than the second decay mode.

54 ENVIRONMENTAL SCIENCES↗

Fast estimation of dense gas dispersion from multiple continuous CO 2 surface leakage sources for risk assessment

Surface leakage of CO 2 , and associated potential impacts on health, safety, and the environment (HSE) are considered hazards of geologic carbon sequestration (GCS). There are two challenges associated with impact assessment of CO 2 surface dispersion. First, the fact that CO 2 is a dense gas makes its dispersion in air a complex process. Rigorous numerical solutions for modeling concentration distributions are relatively time-consuming. Second, impact assessment requires consideration of uncertainty, e.g., quantification of how much uncertainty is propagated through input parameters to model outputs by carrying out large numbers of model runs. In order to assess the potential consequences of surface leakage of CO 2 , it is useful to have a model that executes very quickly for repeated model calculations (e.g., in Monte Carlo mode) of the atmospheric dispersion of CO 2 (concentrations as a function of space and time). In addition, the model should be able to handle multiple surface leakage sources. In this work, we have extended the nomograph approach of Britter and McQuaid (1988) for estimating dense gas plume length from single leakage source to multiple leakage sources. The method is very fast and therefore amenable to general system-level GCS risk assessment including uncertainty quantification within the framework of the National Risk Assessment Partnership (NRAP) Integrated Assessment Model (IAM). The method is conservative in that it assumes the wind could be from any direction, and it handles multiple sources by a simple superposition approach. The method produces results in reasonable agreement with a sophisticated computational fluid dynamics (CFD) code, but runs in a small fraction of the time.

58 GEOSCIENCES↗

Field Demonstration of CO 2 Leakage Detection in Potable Aquifers with a Pulselike CO 2 -Release Test

Here, this study presents two field pulse-like CO 2 -release tests to demonstrate CO 2 leakage detection in a shallow aquifer by monitoring groundwater pH, alkalinity and dissolved inorganic carbon (DIC) using the periodic groundwater sampling method and a fiber-optic CO 2 sensor for real-time in situ monitoring of dissolved CO 2 in groundwater. Measurements of groundwater pH, alkalinity, DIC and dissolved CO 2 clearly deviated from their background values, showing responses to CO 2 leakage. Dissolved CO 2 observed in the tests was highly sensitive in comparison to groundwater pH, DIC, and alkalinity. Comparison of the pulse-like CO 2 -release tests to other field tests suggests that pulse-like CO 2 -release tests can provide reliable assessment of geochemical parameters indicative of CO 2 leakage. Measurements by the fiber-optic CO 2 sensor, showing obvious leakage signals, demonstrated the potential of real-time in situ monitoring of dissolved CO 2 for leakage detection at a GCS site. Results of a two-dimensional reactive transport model reproduced the geochemical measurements and confirmed that the decrease in groundwater pH and the increases in DIC and dissolved CO 2 observed in the pulse-like CO 2 -release tests were caused by dissolution of CO 2 whereas alkalinity was likely affected by carbonate dissolution.

54 ENVIRONMENTAL SCIENCES↗

A 2-D/1-D transverse leakage approximation based on azimuthal, Fourier moments

Here, the MPACT code being developed collaboratively by Oak Ridge National Laboratory and the University of Michigan is the primary deterministic neutron transport solver within the Virtual Environment for Reactor Applications Core Simulator (VERA-CS). In MPACT, the two-dimensional (2-D)/one-dimensional (1-D) scheme is the most commonly used method for solving neutron transport-based three-dimensional nuclear reactor core physics problems. Several axial solvers in this scheme assume isotropic transverse leakages, but work with the axial S N solver has extended these leakages to include both polar and azimuthal dependence. However, explicit angular representation can be burdensome for run-time and memory requirements. The work here alleviates this burden by assuming that the azimuthal dependence of the angular flux and transverse leakages are represented by a Fourier series expansion. At the heart of this is a new axial SN solver that takes in a Fourier expanded radial transverse leakage and generates the angular fluxes used to construct the axial transverse leakages used in the 2-D-Method of Characteristics calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Statistical imprints of CMB B -type polarization leakage in an incomplete sky survey analysis

One of the main goals of modern cosmology is to search for primordial gravitational waves by looking on their imprints in the B -type polarization in the cosmic microwave background radiation. However, this signal is contaminated by various sources, including cosmic weak lensing, foreground radiations, instrumental noises, as well as the E -to- B leakage caused by the partial sky surveys, which should be well understood to avoid the misinterpretation of the observed data. In this paper, we adopt the E / B decomposition method suggested by Smith in 2006, and study the imprints of E -to- B leakage residuals in the constructed B -type polarization maps, B( n-circumflex ), by employing various statistical tools. We find that the effects of E -to- B leakage are negligible for the B-mode power spectrum, as well as the skewness and kurtosis analyses of B-maps. However, if employing the morphological statistical tools, including Minkowski functionals and/or Betti numbers, we find the effect of leakage can be detected at very high confidence level, which shows that in the morphological analysis, the leakage can play a significant role as a contaminant for measuring the primordial B -mode signal and must be taken into account for a correct explanation of the data.

79 ASTRONOMY AND ASTROPHYSICS↗