The isolation of Ni/Co double salts can be recovered by fractional precipitation with ammonium sulfate. The elemental analysis of these isolated double salts shows a total metal composition of >99% of Ni, Co, and Mn with negligible impurity metals.
Coal Combustion Residual (CCR) landfills in the U.S. can lead to elevated contaminant concentrations in groundwater and runoff, particularly of arsenic, boron, and selenium. Zeolites can be readily synthesized from materials contained within the coal combustion ash impoundments and can be cation-exchanged to enhance adsorption capacity, selectivity, and reactivity. However, the optimization of zeolites becomes a daunting task when accounting for the variety of Si:Al ratios, the species of extra-framework cations present, and the zeolite pore structure. Molecular simulations provide methods to study and guide the design of zeolites for the sorption of contaminants from aqueous solution. In this work, models that predict the sorption of arsenic, boron, and selenium from water using cation-exchanged zeolites. Because of the lack of experimental adsorption data for these species of contaminants, models were parametrized to reproduce the results of first-principles calculations and then used to predict sorption for zeolites for a dataset containing 6000 combinations of zeolites and sorption conditions. Machine learning was used to train a model to predict sorption for materials in this database based on the results of the molecular simulations. Next, a genetic algorithm was used to optimize zeolites for the removal of each contaminant from aqueous solution for individual impoundment sites based on contaminant concentrations reported by the Electric Power Research Institute.
This talk presents the design of operationally flexible diafiltration membrane systems for Li/Co recovery, and applies robust optimization methodologies using these flexible systems to generate optimal designs immune to membrane manufacturing variability and uncertain process inlet conditions. The results highlight the use of robust optimization to find design strategies and insights that may reduce technical risks arising from model uncertainties.
Explore the source record for details and available documents.
The results of monitoring the chemical composition of rain in east-central Florida have shown that the rain is moderately acid. The measured acidity of rain is less than that observed in other regions of the U. S., however, it does suggest that the level of acidity is substantial. The annual chemical composition of rain at UCF and at KSC has shown moderate variability. Extreme daily and monthly variations are observed, however these variations are not addressed here. The total ionic composition of rain collected at FL99 is greater than that for rain collected at UCF, however this can be accounted for by site proximity to the ocean with the accompanying marine influence. Difference in acidity data collected from the UCF and FL99 sites which are separated by 50 km may be due in part to the differences that have been observed between laboratory and field pH measurements. Trend assessment for precipitation composition requires evaluation of data that covers some minimum time period. In fact, the subdivision of the multi-year UCF record into individual 10 year records as described above can lead to the conclusion that a significant increase, a significant decrease or no trend exists for acidity depending upon the time period chosen for evaluation. Trend evaluation has also been accomplished by linear and nonlinear regression analysis using monthly volume weighted average concentrations and deposition using the UCF data set and some of the Florida NADP data set.
This report discusses the application of a novel polyacrylate-based ion-exchange material (IEM) for the removal of lead (Pb) ions from water. Preliminary testing includes the establishment of the operating pH range, capacity information, and the effect of calcium and anions in the matrix. Batch testing with powder indicates slightly different optimal operational conditions from those used for column testing. The ion exchanger is excellent for removing lead from aqueous solutions.
The present invention concerns a process of selective precipitation for the purpose of recovering rare earth elements from acidic media derived from coal and coal byproducts via two main steps of sequential precipitation and selective precipitation. An intermediary step of re-precipitation can be included to further increase RRE concentrations, as well as improve contaminant metal removal.
46th International Technical Conference on Clean Energy, Clearwater, FL, August 1-4, 2022
Pittsburgh Coal Conference, Pittsburgh, PA, September 19-22, 2022
The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated into the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)
This report is a compilation of the groundwater and waste cell leachate sampling results from the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site, Nye County, Nevada. Groundwater samples from the aquifer immediately below the Area 5 RWMS have been collected and analyzed and static water levels have been measured in this aquifer since 1993. These groundwater data are evaluated for evidence of effects on the aquifer related to the Area 5 RWMS. Leachate from one lined mixed waste cell at the Area 5 RWMS (Cell 18) has been sampled since the cell opened in 2011. These leachate data are analyzed for hazardous contaminants to determine appropriate leachate handling and disposal. A second lined mixed waste cell at the Area 5 RWMS (Cell 25) began receiving waste in August 2018, but no leachate samples were collected or analyzed during 2018. This report includes data from 2014 through 2018 but focuses on the 2018 data. During 2018, groundwater samples were collected and static water levels were measured at three wells surrounding the Area 5 RWMS. Groundwater samples were collected at wells UE5PW-1, UE5PW-2, and UE5PW-3 on March 6 and August 14, 2018. Static water levels were measured at each of these wells on March 5, June 4, August 13, and October 25, 2018. Groundwater monitoring at the Area 5 RWMS complies with Title 40 Code of Federal Regulations (CFR) Part 264.97, General ground-water monitoring requirements , and 40 CFR 264.98, Detection monitoring program. Groundwater samples were analyzed for indicators of contamination (pH, specific conductance [SC], total organic carbon, total organic halides, and tritium) and, beginning in 2017, toxicity characteristic metals (arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver). General water chemistry parameters (calcium, iron, magnesium, manganese, potassium, sodium, sulfate, chloride, fluoride, bicarbonate, and silicate) were also measured. Results from samples collected in 2018 are within the limits for each parameter established by the Nevada Division of Environmental Protection in Resource Conservation and Recovery Act (RCRA) Permit NEV HW0101, Revision 6. Data from the shallow aquifer indicate there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS, and there were no significant changes in measured groundwater parameters compared to previous years. Leachate from lined mixed waste Cell 18 drains into a sump and is pumped into an above ground tank. Samples are collected from the tank when the leachate volume approaches the 3,000-gallon tank capacity. During 2018, leachate samples were collected on March 1, 2018 and August 1, 2018. All leachate analysis results are below the regulatory levels for toxicity characteristic contaminants (40 CFR 261.24) and below the investigation levels for polychlorinated biphenyls (PCBs), tritium, pH, and SC specified in RCRA Permit NEV HW0101, Revision 6. No quantifiable PCB levels were detected in any leachate sample. Based on the leachate analysis results, RCRA Permit NEV HW0101 allowed all leachate collected from Cell 18 to be pumped from the collection tank and used for dust control at Cell 18.
Highlights: ► The isotopic signature of δ{sup 13}C-DIC of leachates is linked to the reactivity of MSW. ► Isotopic signatures of leachates depend on aerobic/anaerobic conditions in landfills. ► In situ aeration of landfills can be monitored by isotope analysis in leachate. ► The isotopic analysis of leachates can be used for assessing the stability of MSW. ► δ{sup 13}C-DIC of leachates helps to define the duration of landfill aftercare. - Abstract: Stable isotopic signatures of landfill leachates are influenced by processes within municipal solid waste (MSW) landfills mainly depending on the aerobic/anaerobic phase of the landfill. We investigated the isotopic signatures of δ{sup 13}C, δ{sup 2}H and δ{sup 18}O of different leachates from lab-scale experiments, lysimeter experiments and a landfill under in situ aeration. In the laboratory, columns filled with MSW of different age and reactivity were percolated under aerobic and anaerobic conditions. In landfill simulation reactors, waste of a 25 year old landfill was kept under aerobic and anaerobic conditions. The lysimeter facility was filled with mechanically shredded fresh waste. After starting of the methane production the waste in the lysimeter containments was aerated in situ. Leachate and gas composition were monitored continuously. In addition the seepage water of an old landfill was collected and analysed periodically before and during an in situ aeration. We found significant differences in the δ{sup 13}C-value of the dissolved inorganic carbon (δ{sup 13}C-DIC) of the leachate between aerobic and anaerobic waste material. During aerobic degradation, the signature of δ{sup 13}C-DIC was mainly dependent on the isotopic composition of the organic matter in the waste, resulting in a δ{sup 13}C-DIC of −20‰ to −25‰. The production of methane under anaerobic conditions caused an increase in δ{sup 13}C-DIC up to values of +10‰ and higher depending on the actual reactivity of the MSW. During aeration of a landfill the aerobic degradation of the remaining organic matter caused a decrease to a δ{sup 13}C-DIC of about −20‰. Therefore carbon isotope analysis in leachates and groundwater can be used for tracing the oxidation–reduction status of MSW landfills. Our results indicate that monitoring of stable isotopic signatures of landfill leachates over a longer time period (e.g. during in situ aeration) is a powerful and cost-effective tool for characterising the biodegradability and stability of the organic matter in landfilled municipal solid waste and can be used for monitoring the progress of in situ aeration.